Nagios XI 5.5.6 allows remote authenticated attackers to execute arbitrary commands via a crafted HTTP request.
D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via keys smartqos_express_devices and smartqos_normal_devices in SetSmartQoSSettings.
DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the name parameter in the run_command function.
An issue was discovered in Pacom Unison Client 5.13.1. Authenticated users can inject malicious scripts in the Report Templates which are executed when certain script conditions are fulfilled, leading to Remote Code Execution.
There is a command injection vulnerability that may allow an attacker to inject malicious input on the device's operating system.
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. Prior to version 4.0.0-beta.451, an authenticated command injection vulnerability in the Database Import functionality allows users with application/service management permissions to execute arbitrary commands as root on managed servers. Database names used in import operations are passed directly to shell commands without sanitization, enabling full remote code execution. Version 4.0.0-beta.451 fixes the issue.
DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the value parameter in the filter_string function.
Main_Analysis_Content.asp in ASUS DSL-N12E_C1 1.1.2.3_345 is prone to Authenticated Remote Command Execution, which allows a remote attacker to execute arbitrary OS commands via service parameters, such as shell metacharacters in the destIP parameter of a cmdMethod=ping request.
A low privileged remote attacker can read and write files as root due to improper neutralization of special elements in the variable EMAIL_RELAY_PASSWORD in mGuard devices.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
The Plainview Activity Monitor plugin before 20180826 for WordPress is vulnerable to OS command injection via shell metacharacters in the ip parameter of a wp-admin/admin.php?page=plainview_activity_monitor&tab=activity_tools request.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Microhard Bullet-LTE prior to v1.2.0-r1112. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of the ping parameter provided to tools.sh. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-10595.
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable PROXY_HTTP_PORT in mGuard devices.
Jenkins Azure CLI Plugin 0.9 and earlier does not restrict which commands it executes on the Jenkins controller, allowing attackers with Item/Configure permission to execute arbitrary shell commands.
A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable EMAIL_NOTIFICATION.TO in mGuard devices.
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setWanIeCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setModifyVpnUser. Authenticated Attackers can send malicious packet to execute arbitrary commands.
N-Reporter and N-Cloud, products of the N-Partner, have an OS Command Injection vulnerability. Remote attackers with normal user privilege can execute arbitrary system commands by manipulating user inputs on a specific page.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setUrlFilterRules. Authenticated Attackers can send malicious packet to execute arbitrary commands.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in delBlacklist. Authenticated Attackers can send malicious packet to execute arbitrary commands.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setSyslogCfg . Authenticated Attackers can send malicious packet to execute arbitrary commands.
A Command Injection vulnerability exists in the do_upgrade_post function of the httpd binary in Linksys E1500 v1.0.06.001. As a result, an authenticated attacker can execute OS commands with root privileges.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setAccessDeviceCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
In TOTOLINK X5000r v9.1.0cu.2350_b20230313, the file /cgi-bin/cstecgi.cgi contains an OS command injection vulnerability in setDmzCfg. Authenticated Attackers can send malicious packet to execute arbitrary commands.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the management commands of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device via Telnet.
**UNSUPPORTED WHEN ASSIGNED** A post-authentication command injection vulnerability in the CGI program of the legacy DSL CPE Zyxel VMG4325-B10A firmware version 1.00(AAFR.4)C0_20170615 could allow an authenticated attacker to execute operating system (OS) commands on an affected device by sending a crafted HTTP POST request.
Nagios XI 5.5.6 allows remote authenticated attackers to reset and regenerate the API key of more privileged users. The attacker can then use the new API key to execute API calls at elevated privileges.
An authenticated command injection vulnerability exists in the HPE Aruba Networking EdgeConnect SD-WAN gateways Command Line Interface. Successful exploitation of this vulnerability results in the ability to execute arbitrary commands as a privileged user on the underlying operating system.
A shell escape vulnerability in /webconsole/Controller in Admin Portal of Sophos XG firewall 17.0.8 MR-8 allow remote authenticated attackers to execute arbitrary OS commands via shell metacharacters in the "dbName" POST parameter.
An authenticated command injection vulnerability exists in IPFire Firewall before 2.21 Core Update 124 in backup.cgi. This allows an authenticated user with privileges for the affected page to execute arbitrary commands.
A vulnerability, which was classified as critical, was found in Wifi-soft UniBox Controller up to 20250506. This affects an unknown part of the file /billing/pms_check.php. The manipulation of the argument ipaddress leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
jc21 NGINX Proxy Manager before 2.11.3 allows backend/internal/certificate.js OS command injection by an authenticated user (with certificate management privileges) via untrusted input to the DNS provider configuration. NOTE: this is not part of any NGINX software shipped by F5.
rejetto HFS (aka HTTP File Server) 3 before 0.52.10 on Linux, UNIX, and macOS allows OS command execution by remote authenticated users (if they have Upload permissions). This occurs because a shell is used to execute df (i.e., with execSync instead of spawnSync in child_process in Node.js).
A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in cym1102 nginxWebUI up to 3.9.9. This vulnerability affects unknown code of the file /adminPage/main/upload. The manipulation of the argument file leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260578 is the identifier assigned to this vulnerability.
Coolify is an open-source and self-hostable tool for managing servers, applications, and databases. Prior to version 4.0.0-beta.420.7, the Git Repository field during project creation is vulnerable to command injection. User input is not properly sanitized, allowing attackers to inject arbitrary shell commands that execute on the underlying server during the deployment workflow. A regular member user can exploit this vulnerability. Version 4.0.0-beta.420.7 contains a patch for the issue.
A vulnerability was found in TBK DVR-4104 and DVR-4216 up to 20240412 and classified as critical. This issue affects some unknown processing of the file /device.rsp?opt=sys&cmd=___S_O_S_T_R_E_A_MAX___. The manipulation of the argument mdb/mdc leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260573 was assigned to this vulnerability.
OS Command Injection vulnerability in Ruijie RG-BCR RG-BCR860 allowing attackers to execute arbitrary commands via a crafted POST request to the network_set_wan_conf in file /usr/lib/lua/luci/controller/admin/netport.lua.
OS Command Injection vulnerability in Ruijie RG-BCR RG-BCR600W allowing attackers to execute arbitrary commands via a crafted POST request to the check_changes in file /usr/lib/lua/luci/controller/admin/common.lua.
FutureNet NXR series, VXR series and WXR series provided by Century Systems Co., Ltd. contain an active debug code vulnerability. If a user who knows how to use the debug function logs in to the product, the debug function may be used and an arbitrary OS command may be executed.
A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
1Panel is an open source Linux server operation and maintenance management panel. An OS command injection vulnerability exists in 1Panel firewall functionality. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability. 1Panel firewall functionality `/hosts/firewall/ip` endpoint read user input without validation, the attacker extends the default functionality of the application, which execute system commands. An attacker can execute arbitrary code on the target system, which can lead to a complete compromise of the system. This issue has been addressed in commit `e17b80cff49` which is included in release version `1.4.3`. Users are advised to upgrade. There are no known workarounds for this vulnerability.
This vulnerability exists in ESDS Emagic Data Center Management Suit due to lack of input sanitization in its Ping component. A remote authenticated attacker could exploit this by injecting OS commands on the targeted system. Successful exploitation of this vulnerability could allow the attacker to execute arbitrary code on targeted system.
Synel SYnergy Fingerprint Terminals - CWE-78: 'OS Command Injection'