Cross Site Scripting vulnerability in phpcmsv9 v.9.6.3 allows a remote attacker to escalate privileges via the menu interface of the member center of the background administrator.
Multiple cross-site scripting (XSS) vulnerabilities in the Guestbook module for PHPCMS allow remote attackers to inject arbitrary web script or HTML via the (1) list or (2) introduce parameter to index.php.
Cross Site Scripting vulnerabilities in phpcmsv9 v.9.6.3 allows a remote attacker to escalate privileges via a crafted script.
PHPCMS 9.6.x through 9.6.3 has XSS via the mailbox (aka E-mail) field on the personal information screen.
login.php in Adiscon LogAnalyzer before 4.1.7 has XSS via the Login Button Referer field.
Seo Panel 4.8.0 allows reflected XSS via the seo/seopanel/login.php?sec=forgot email parameter.
The "upsell" widget at the portal page could be abused to inject arbitrary script code. Attackers that manage to lure users to a compromised account, or gain temporary access to a legitimate account, could inject script code to gain persistent code execution capabilities under a trusted domain. User input for this widget is now sanitized to avoid malicious content the be processed. No publicly available exploits are known.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Zenitel Norway IP-StationWeb before 4.2.3.9 allows reflected XSS via the goform/ PATH_INFO.
An issue was discovered in GitLab Community and Enterprise Edition 11.x before 11.3.11, 11.4.x before 11.4.8, and 11.5.x before 11.5.1. There is a persistent XSS vulnerability in the environment pages due to a lack of input validation and output encoding.
Uvdesk version 1.1.1 allows an unauthenticated remote attacker to exploit a stored XSS in the application. This is possible because the application does not correctly validate the message sent by the clients in the ticket.
Zenphoto 1.4.14 has multiple cross-site scripting (XSS) vulnerabilities via different URL parameters.
A vulnerability has been reported in Cups Easy (Purchase & Inventory), version 1.0, whereby user-controlled inputs are not sufficiently encoded, resulting in a Cross-Site Scripting (XSS) vulnerability via /cupseasylive/stockissuancelist.php, in the delete parameter. Exploitation of this vulnerability could allow a remote attacker to send a specially crafted URL to an authenticated user and steal their session cookie credentials.
A vulnerability classified as problematic has been found in SourceCodester Vehicle Service Management System 1.0. This affects an unknown part of the file /classes/Users.php. The manipulation of the argument id leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-226107.
Cross-site scripting (XSS) vulnerability in HP Business Availability Center (BAC) 8.06 and earlier allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
A Cross-Site Scripting (XSS) vulnerability exists in the reorder administrator functions in sNews 1.71.
Podcast Generator 2.7 has stored cross-site scripting (XSS) via the URL addcategory parameter.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "PresentSpace.jsp" has reflected XSS via the GroupId and ConnPoolName parameters.
HMS Industrial Networks Netbiter WS100 3.30.5 devices and previous have reflected XSS in the login form.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/Import.jsp" has reflected XSS via the ConnPoolName parameter.
The Simple Buttons Creator WordPress plugin through 1.04 does not have any authorisation as well as CSRF in its add button function, allowing unauthenticated users to call them either directly or via CSRF attacks. Furthermore, due to the lack of sanitisation and escaping, it could also allow them to perform Stored Cross-Site Scripting attacks against logged in admins.
Microweber 1.0.8 has reflected cross-site scripting (XSS) vulnerabilities.
XSS in the Ninja Forms plugin before 3.3.18 for WordPress allows Remote Attackers to execute JavaScript via the includes/Admin/Menus/Submissions.php (aka submissions page) begin_date, end_date, or form_id parameter.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "EditCurrentPresentSpace.jsp" has reflected XSS via the ConnPoolName, GroupId, and ParentId parameters.
Cross-site scripting (XSS) vulnerability in HP SiteScope 9.54, 10.13, 11.01, and 11.1 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/Rights.jsp" has reflected XSS via the ConnPoolName parameter.
Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV016, RV042, RV042G, RV082, RV320, and RV325 Routers could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against a user of the interface. These vulnerabilities are due to insufficient input validation by the web-based management interface. An attacker could exploit these vulnerabilities by sending crafted HTTP requests to an affected device and then persuading a user to visit specific web pages that include malicious payloads. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. Cisco has not released software updates that address these vulnerabilities.
A vulnerability classified as problematic has been found in SourceCodester Online Payroll System 1.0. This affects an unknown part of the file /admin/employee_add.php. The manipulation of the argument of leads to cross site scripting. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-224991.
Persistent XSS exists in XSLT CMS via the create/?action=items.edit&type=Page "body" field.
Cross-site scripting (XSS) vulnerability in admin/walkthrough/walkthrough.php in the Design Approval System plugin before 3.7 for WordPress allows remote attackers to inject arbitrary web script or HTML via the step parameter.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Cimatti Consulting Contact Forms by Cimatti allows Stored XSS.This issue affects Contact Forms by Cimatti: from n/a through 1.7.0.
Maccms through 8.0 allows XSS via the site_keywords field to index.php?m=system-config because of tpl/module/system.php and tpl/html/system_config.html, related to template/paody/html/vod_index.html.
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Yannick Lefebvre Link Library allows Reflected XSS.This issue affects Link Library: from n/a through 7.6.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/GroupCopy.jsp" has reflected XSS via the ConnPoolName, GroupId, or type parameter.
A vulnerability, which was classified as problematic, has been found in code-projects Simple Art Gallery 1.0. Affected by this issue is some unknown functionality of the file adminHome.php. The manipulation of the argument about_info leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-223400.
A vulnerability was found in SourceCodester Gadget Works Online Ordering System 1.0. It has been rated as problematic. This issue affects some unknown processing of the file /admin/products/index.php of the component GET Parameter Handler. The manipulation of the argument view with the input <script>alert(666)</script> leads to cross site scripting. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-224747.
Multiple cross-site scripting (XSS) vulnerabilities in the oraadmin service page in Cisco MediaSense allow remote attackers to inject arbitrary web script or HTML via an unspecified parameter, aka Bug IDs CSCuj23320, CSCuj23324, CSCuj23333, and CSCuj23338.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/Contacts.jsp" has reflected XSS via the ConnPoolName parameter.
A vulnerability in the web-based management interface of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability is due to insufficient validation of user input. An attacker could exploit this vulnerability by persuading a user of an affected interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the browser of the targeted user or access sensitive, browser-based information.
MetInfo 6.x through 6.1.3 has XSS via the /admin/login/login_check.php url_array[] parameter.
Artica Integria IMS 5.0.83 has XSS via the search_string parameter.
Metinfo 6.1.3 has reflected XSS via the admin/column/move.php lang_columnerr4 parameter.
Cross Site Scripting exists in InfoVista VistaPortal SE Version 5.1 (build 51029). The page "/VPortal/mgtconsole/SharedCriteria.jsp" has reflected XSS via the ConnPoolName or GroupId parameter.
Cross-site scripting (XSS) vulnerability in Atmail Webmail Server before 7.2 allows remote attackers to inject arbitrary web script or HTML via the body of an e-mail message, as demonstrated by the SRC attribute of an IFRAME element.
In WordPress before 4.9.9 and 5.x before 5.0.1, crafted URLs could trigger XSS for certain use cases involving plugins.
Cross-site Scripting (XSS) in EasyXDM before 2.4.18 allows remote attackers to inject arbitrary web script or html via the easyxdm.swf file.
The Ebook Store WordPress plugin before 5.8015 does not escape the $_SERVER['REQUEST_URI'] parameter before outputting it back in an attribute, which could lead to Reflected Cross-Site Scripting in old web browsers.
Cross-site scripting (XSS) vulnerability in afa/php/Login.php in AlgoSec Firewall Analyzer 6.1-b86 allows remote attackers to inject arbitrary web script or HTML via the PATH_INFO.
Multiple vulnerabilities in the web-based management interface of Cisco Small Business RV016, RV042, RV042G, RV082, RV320, and RV325 Routers could allow an unauthenticated, remote attacker to conduct cross-site scripting (XSS) attacks against a user of the interface. These vulnerabilities are due to insufficient input validation by the web-based management interface. An attacker could exploit these vulnerabilities by sending crafted HTTP requests to an affected device and then persuading a user to visit specific web pages that include malicious payloads. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information. Cisco has not released software updates that address these vulnerabilities.
A vulnerability in the file upload functionality of Cisco Webex App for Web could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by sending an arbitrary file to a user and persuading that user to browse to a specific URL. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected interface or access sensitive, browser-based information.