Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2021-43339

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-03 Nov, 2021 | 19:38
Updated At-04 Aug, 2024 | 03:55
Rejected At-
Credits

In Ericsson Network Location before 2021-07-31, it is possible for an authenticated attacker to inject commands via file_name in the export functionality. For example, a new admin user could be created.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:03 Nov, 2021 | 19:38
Updated At:04 Aug, 2024 | 03:55
Rejected At:
▼CVE Numbering Authority (CNA)

In Ericsson Network Location before 2021-07-31, it is possible for an authenticated attacker to inject commands via file_name in the export functionality. For example, a new admin user could be created.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.exploit-db.com/exploits/50469
x_refsource_MISC
https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.html
x_refsource_MISC
https://www.exploit-db.com/exploits/50468
x_refsource_MISC
Hyperlink: https://www.exploit-db.com/exploits/50469
Resource:
x_refsource_MISC
Hyperlink: https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.html
Resource:
x_refsource_MISC
Hyperlink: https://www.exploit-db.com/exploits/50468
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.exploit-db.com/exploits/50469
x_refsource_MISC
x_transferred
https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.html
x_refsource_MISC
x_transferred
https://www.exploit-db.com/exploits/50468
x_refsource_MISC
x_transferred
Hyperlink: https://www.exploit-db.com/exploits/50469
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.html
Resource:
x_refsource_MISC
x_transferred
Hyperlink: https://www.exploit-db.com/exploits/50468
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:03 Nov, 2021 | 20:15
Updated At:30 Nov, 2021 | 21:30

In Ericsson Network Location before 2021-07-31, it is possible for an authenticated attacker to inject commands via file_name in the export functionality. For example, a new admin user could be created.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Ericsson
ericsson
>>network_location>>Versions before 2021-07-31(exclusive)
cpe:2.3:a:ericsson:network_location:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Primarynvd@nist.gov
CWE ID: CWE-77
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.htmlcve@mitre.org
Exploit
Third Party Advisory
https://www.exploit-db.com/exploits/50468cve@mitre.org
Exploit
Third Party Advisory
VDB Entry
https://www.exploit-db.com/exploits/50469cve@mitre.org
Exploit
Third Party Advisory
VDB Entry
Hyperlink: https://pentest.com.tr/blog/RCE-via-Meow-Variant-along-with-an-Example-0day-PacketHackingVillage-Defcon29.html
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
Hyperlink: https://www.exploit-db.com/exploits/50468
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
VDB Entry
Hyperlink: https://www.exploit-db.com/exploits/50469
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory
VDB Entry

Change History

0
Information is not available yet

Similar CVEs

568Records found

CVE-2025-6898
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.06% / 18.25%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 08:02
Updated-14 Jul, 2025 | 17:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7300G+ in proxy_client.asp os command injection

A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7300g\+_firmwaredi-7300g\+DI-7300G+
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-7614
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.08% / 86.23%
||
7 Day CHG~0.00%
Published-14 Jul, 2025 | 15:02
Updated-15 Jul, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK T6 HTTP POST Request cstecgi.cgi delDevice command injection

A vulnerability classified as critical has been found in TOTOLINK T6 4.1.5cu.748. Affected is the function delDevice of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ipAddr leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-T6
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-7414
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.89% / 74.57%
||
7 Day CHG~0.00%
Published-10 Jul, 2025 | 20:32
Updated-16 Jul, 2025 | 15:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda O3V2 httpd setPingInfo fromNetToolGet os command injection

A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-o3_firmwareo3O3V2
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-45600
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.4||HIGH
EPSS-2.27% / 84.00%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:39
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850cbr750rbs850_firmwarerbr850rbk852rbk852_firmwarecbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5763
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.46% / 63.09%
||
7 Day CHG~0.00%
Published-06 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda CP3 apollo sub_F3C8C command injection

A vulnerability has been found in Tenda CP3 11.10.00.2311090948 and classified as critical. Affected by this vulnerability is the function sub_F3C8C of the file apollo. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-cp3cp3_firmwareCP3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6103
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.22% / 44.43%
||
7 Day CHG-0.03%
Published-16 Jun, 2025 | 03:00
Updated-16 Jun, 2025 | 18:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wifi-soft UniBox Controller test_accesscodelogin.php os command injection

A vulnerability, which was classified as critical, has been found in Wifi-soft UniBox Controller up to 20250506. Affected by this issue is some unknown functionality of the file /billing/test_accesscodelogin.php. The manipulation of the argument Password leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Wifi-soft
Product-UniBox Controller
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-26297
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.28% / 51.29%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 22:03
Updated-27 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6618
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.57%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE wps.so SetWLanApcliSettings os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been classified as critical. Affected is the function SetWLanApcliSettings of the file wps.so. The manipulation of the argument PIN leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5504
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.26% / 90.54%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formWsc command injection

A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26294
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.20% / 41.87%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 21:54
Updated-27 Mar, 2025 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-26296
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-0.28% / 51.29%
||
7 Day CHG~0.00%
Published-27 Feb, 2024 | 21:57
Updated-27 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. A successful exploit could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)Aruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Managerclearpass_policy_manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.63%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 60.63%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-43469
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-9.40% / 92.47%
||
7 Day CHG~0.00%
Published-06 Dec, 2021 | 11:48
Updated-04 Aug, 2024 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VINGA WR-N300U 77.102.1.4853 is affected by a command execution vulnerability in the goahead component.

Action-Not Available
Vendor-vingan/a
Product-wr-n300u_firmwarewr-n300un/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5492
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.05% / 15.81%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5571
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.21%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 05:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemAdmin os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. Affected is the function setSystemAdmin of the file /setSystemAdmin. The manipulation of the argument AdminID leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-44520
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-6.13% / 90.43%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 23:21
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Citrix XenMobile Server through 10.12 RP9, there is an Authenticated Command Injection vulnerability, leading to remote code execution with root privileges.

Action-Not Available
Vendor-n/aCitrix (Cloud Software Group, Inc.)
Product-xenmobile_servern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.72%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5502
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.65%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:00
Updated-06 Jun, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 formMapReboot command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x15x15_firmwareX15
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2021-43161
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.54% / 84.88%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 00:08
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the doSwitchApi function in /cgi-bin/luci/api/switch.

Action-Not Available
Vendor-n/aRuijie Networks Co., Ltd.
Product-rg-ew300_prorg-ew1200g_prorg-ew1800gx_prorg-ew3200gx_proreyeeosrg-ew1200n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-25955
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.2||HIGH
EPSS-0.42% / 61.24%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 19:05
Updated-27 Jan, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.

Action-Not Available
Vendor-Dell Inc.
Product-solutions_enabler_virtual_appliancepowermax_eemunisphere_for_powermax_virtual_applianceVirtual Appliance (vApp) Managerunisphere_for_powermax_virtual_appliancesolutions_enabler_virtual_applianceunisphere_for_powermax
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.46%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-2736
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-7.2||HIGH
EPSS-1.06% / 76.70%
||
7 Day CHG~0.00%
Published-22 Nov, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

VCM5010 with software versions earlier before V100R002C50SPC100 has a command injection vulnerability. This is due to insufficient validation of user's input. An authenticated attacker could launch a command injection attack.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-vcm5010vcm5010_firmwareVCM5010
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5438
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.53% / 66.39%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 09:00
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 WPS command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. Affected by this vulnerability is the function WPS of the file /goform/WPS. The manipulation of the argument PIN leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-42538
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8||HIGH
EPSS-0.19% / 41.20%
||
7 Day CHG~0.00%
Published-22 Oct, 2021 | 13:23
Updated-17 Sep, 2024 | 00:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Emerson WirelessHART Gateway

The affected product is vulnerable to a parameter injection via passphrase, which enables the attacker to supply uncontrolled input.

Action-Not Available
Vendor-emersonEmerson
Product-wireless_1420_gatewaywireless_1410_gatewaywireless_1410d_gatewaywireless_1410_gateway_firmwarewireless_1420_gateway_firmwarewireless_1410d_gateway_firmwareWirelessHART Gateway
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-1811
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.32%
||
7 Day CHG~0.00%
Published-17 Feb, 2020 | 23:28
Updated-04 Aug, 2024 | 06:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

GaussDB 200 with version of 6.5.1 have a command injection vulnerability. Due to insufficient input validation, remote attackers with low permissions could exploit this vulnerability by sending crafted commands to the affected device. Successful exploit could allow an attacker to execute commands.

Action-Not Available
Vendor-Huawei Technologies Co., Ltd.
Product-gaussdb_200GaussDB 200
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2021-43160
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.54% / 84.88%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 00:08
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the switchFastDhcp function in /cgi-bin/luci/api/diagnose.

Action-Not Available
Vendor-n/aRuijie Networks Co., Ltd.
Product-rg-ew300_prorg-ew1200g_prorg-ew1800gx_prorg-ew3200gx_proreyeeosrg-ew1200n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.23%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 12:31
Updated-10 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkFWByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this issue is the function RP_checkFWByBBS of the file /goform/RP_checkFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-43159
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.54% / 84.88%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 00:08
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the setSessionTime function in /cgi-bin/luci/api/common..

Action-Not Available
Vendor-n/aRuijie Networks Co., Ltd.
Product-rg-ew300_prorg-ew1200g_prorg-ew1800gx_prorg-ew3200gx_proreyeeosrg-ew1200n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43162
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.54% / 84.88%
||
7 Day CHG~0.00%
Published-04 May, 2022 | 00:08
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the runPackDiagnose function in /cgi-bin/luci/api/diagnose.

Action-Not Available
Vendor-n/aRuijie Networks Co., Ltd.
Product-rg-ew300_prorg-ew1200g_prorg-ew1800gx_prorg-ew3200gx_proreyeeosrg-ew1200n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-42559
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-2.99% / 86.01%
||
7 Day CHG~0.00%
Published-12 Jan, 2022 | 19:11
Updated-04 Aug, 2024 | 03:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in CALDERA 2.8.1. It contains multiple startup "requirements" that execute commands when starting the server. Because these commands can be changed via the REST API, an authenticated user can insert arbitrary commands that will execute when the server is restarted.

Action-Not Available
Vendor-mitren/a
Product-calderan/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.39% / 59.12%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5515
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-6.26% / 90.54%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 17:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formMapDel command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X2000R 1.0.0-B20230726.1108. Affected by this issue is some unknown functionality of the file /boafrm/formMapDel. The manipulation of the argument devicemac1 leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-42129
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-51.66% / 97.81%
||
7 Day CHG~0.00%
Published-07 Dec, 2021 | 13:13
Updated-04 Aug, 2024 | 03:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability exists in Ivanti Avalanche before 6.3.3 allows an attacker with access to the Inforail Service to perform arbitrary command execution.

Action-Not Available
Vendor-n/aIvanti Software
Product-avalancheIvanti Avalanche
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-4304
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.53% / 66.33%
||
7 Day CHG~0.00%
Published-05 Jan, 2023 | 09:59
Updated-28 May, 2025 | 13:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
eprintsug ulcc-core toolbox command injection

A vulnerability was found in eprintsug ulcc-core. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file cgi/toolbox/toolbox. The manipulation of the argument password leads to command injection. The attack can be launched remotely. The patch is named 811edaae81eb044891594f00062a828f51b22cb1. It is recommended to apply a patch to fix this issue. The associated identifier of this vulnerability is VDB-217447.

Action-Not Available
Vendor-ulcc-core_projecteprintsug
Product-ulcc-coreulcc-core
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41001
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-8.8||HIGH
EPSS-5.50% / 89.84%
||
7 Day CHG~0.00%
Published-02 Mar, 2022 | 21:38
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authenticated remote code execution vulnerability was discovered in the AOS-CX Network Analytics Engine (NAE) in Aruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series version(s): AOS-CX 10.07.xxxx: 10.07.0050 and below, AOS-CX 10.08.xxxx: 10.08.1030 and below, AOS-CX 10.09.xxxx: 10.09.0002 and below. Aruba has released upgrades for Aruba AOS-CX devices that address this security vulnerability.

Action-Not Available
Vendor-n/aHewlett Packard Enterprise (HPE)
Product-aruba_8360-32y4carubaos-cxaruba_cx_6300maruba_8320aruba_8360-16y2caruba_8400xaruba_cx_6200faruba_8325-48y8caruba_8360-24xf2caruba_cx_6300faruba_cx_6405aruba_cx_6410aruba_8325-32-caruba_8360-48xt4caruba_8360-12cAruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-6275
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.01% / 91.09%
||
7 Day CHG~0.00%
Published-19 Mar, 2019 | 19:53
Updated-04 Aug, 2024 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in firmware_cgi in GL.iNet GL-AR300M-Lite devices with firmware 2.27 allows remote attackers to execute arbitrary code.

Action-Not Available
Vendor-gl-inetn/a
Product-gl-ar300m-litegl-ar300m-lite_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45552
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.89% / 74.64%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:51
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.58, R7500v2 before 1.0.3.48, R7800 before 1.0.2.68, R8900 before 1.0.5.2, R9000 before 1.0.5.2, RAX120 before 1.0.1.108, and XR700 before 1.0.1.20.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7500v2d7800_firmwarer7800r8900r9000_firmwarerax120_firmwarer8900_firmwarer7800_firmwarer7500v2_firmwared7800xr700_firmwarerax120r9000xr700n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-40995
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.3||MEDIUM
EPSS-1.52% / 80.50%
||
7 Day CHG~0.00%
Published-15 Oct, 2021 | 14:10
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x prior to 6.10.2 - - ClearPass Policy Manager 6.9.x prior to 6.9.7-HF1 - - ClearPass Policy Manager 6.8.x prior to 6.8.9-HF1. Aruba has released patches for ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-40994
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.3||MEDIUM
EPSS-1.52% / 80.50%
||
7 Day CHG~0.00%
Published-15 Oct, 2021 | 14:07
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote arbitrary command execution vulnerability was discovered in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x prior to 6.10.2 - - ClearPass Policy Manager 6.9.x prior to 6.9.7-HF1 - - ClearPass Policy Manager 6.8.x prior to 6.8.9-HF1. Aruba has released patches for ClearPass Policy Manager that address this security vulnerability.

Action-Not Available
Vendor-n/aAruba Networks
Product-clearpass_policy_managerAruba ClearPass Policy Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41000
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-8.8||HIGH
EPSS-5.50% / 89.84%
||
7 Day CHG~0.00%
Published-02 Mar, 2022 | 21:39
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple authenticated remote code execution vulnerabilities were discovered in the AOS-CX command line interface in Aruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series version(s): AOS-CX 10.06.xxxx: 10.06.0170 and below, AOS-CX 10.07.xxxx: 10.07.0050 and below, AOS-CX 10.08.xxxx: 10.08.1030 and below. Aruba has released upgrades for Aruba AOS-CX devices that address these security vulnerabilities.

Action-Not Available
Vendor-n/aHewlett Packard Enterprise (HPE)
Product-aruba_8360-32y4carubaos-cxaruba_cx_6300maruba_8320aruba_8360-16y2caruba_8400xaruba_cx_6200faruba_8325-48y8caruba_8360-24xf2caruba_cx_6300faruba_cx_6405aruba_cx_6410aruba_8325-32-caruba_8360-48xt4caruba_8360-12cAruba CX 6200F Switch Series, Aruba 6300 Switch Series, Aruba 6400 Switch Series, Aruba 8320 Switch Series, Aruba 8325 Switch Series, Aruba 8400 Switch Series, Aruba CX 8360 Switch Series
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-5424
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-8.8||HIGH
EPSS-1.86% / 82.30%
||
7 Day CHG~0.00%
Published-10 Apr, 2019 | 17:31
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-edgeswitch_xEdgeMAX
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-41599
Matching Score-4
Assigner-GitHub, Inc. (Products Only)
ShareView Details
Matching Score-4
Assigner-GitHub, Inc. (Products Only)
CVSS Score-8.8||HIGH
EPSS-2.50% / 84.71%
||
7 Day CHG~0.00%
Published-17 Feb, 2022 | 23:35
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Improper control flow in GitHub Enterprise Server hosted Pages leads to remote code execution

A remote code execution vulnerability was identified in GitHub Enterprise Server that could be exploited when building a GitHub Pages site. To exploit this vulnerability, an attacker would need permission to create and build a GitHub Pages site on the GitHub Enterprise Server instance. This vulnerability affected all versions of GitHub Enterprise Server prior to 3.3 and was fixed in versions 3.0.21, 3.1.13, 3.2.5. This vulnerability was reported via the GitHub Bug Bounty program.

Action-Not Available
Vendor-GitHub, Inc.
Product-enterprise_serverGitHub Enterprise Server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5145
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.61%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 05:31
Updated-11 Jul, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore POWER13 Query String cgi-bin command injection

A vulnerability, which was classified as critical, was found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2, NBR200V2 and POWER13 up to 20250508. This affects an unknown part of the file /www/cgi-bin/ of the component Query String Handler. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-B6V2NAP930NBR100V2NBR1005GPEV2NBR200V2COVER5NAP830POWER13
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-5323
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-1.12% / 77.30%
||
7 Day CHG~0.00%
Published-27 Feb, 2020 | 16:20
Updated-04 Aug, 2024 | 19:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There are command injection vulnerabilities present in the AirWave application. Certain input fields controlled by an administrative user are not properly sanitized before being parsed by AirWave. If conditions are met, an attacker can obtain command execution on the host.

Action-Not Available
Vendor-n/aAruba Networks
Product-airwaveAirWave Management Platform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-6272
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-7.01% / 91.09%
||
7 Day CHG~0.00%
Published-19 Mar, 2019 | 18:44
Updated-04 Aug, 2024 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command injection vulnerability in login_cgi in GL.iNet GL-AR300M-Lite devices with firmware 2.27 allows remote attackers to execute arbitrary code.

Action-Not Available
Vendor-gl-inetn/a
Product-gl-ar300m-litegl-ar300m-lite_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5146
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 80.46%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 07:00
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR200V2 HTTP Header routerd passwd_set command injection

A vulnerability has been found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2 and NBR200V2 up to 20250508 and classified as critical. This vulnerability affects the function passwd_set of the file /usr/bin/routerd of the component HTTP Header Handler. The manipulation of the argument pwd leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NAP930NBR1005GPEV2B6V2COVER5NBR100V2NAP830NBR200V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4999
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.23% / 46.13%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5126
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.59% / 68.27%
||
7 Day CHG~0.00%
Published-24 May, 2025 | 15:00
Updated-16 Jun, 2025 | 18:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
FLIR AX8 settingsregional.php setDataTime command injection

A vulnerability classified as critical was found in FLIR AX8 up to 1.46.16. This vulnerability affects the function setDataTime of the file \usr\www\application\models\settingsregional.php. The manipulation of the argument year/month/day/hour/minute leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-flirFLIR
Product-flir_ax8flir_ax8_firmwareAX8
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45556
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.50% / 64.98%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:50
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GS108Tv2 before 5.4.2.36, GS110TPP before 7.0.7.2, GS110TPv2 before 5.4.2.36., GS110TPv3 before 7.0.7.2, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS752TPv2 before 6.0.8.2, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-gs728tppv2gs308tgs310tp_firmwaregs308t_firmwaregs110tpv3_firmwaregs110tppgs108tv2_firmwaregs724tpp_firmwaregs728tpv2_firmwaregs752tpv2_firmwarems510txup_firmwaregs110tpv2_firmwaregs752tppms510txupgs108tv2gs752tpv2gs752tpp_firmwarems510txm_firmwaregs724tpv2ms510txmgs724tpv2_firmwaregs110tpv2gs110tpp_firmwaregs110tpv3gs728tppv2_firmwaregs724tppgs728tpv2gs310tpn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 11
  • 12
  • Next
Details not found