A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 7061/tcp. This vulnerability is independent from CVE-2019-18310. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges.
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.
The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation.
There are some web interfaces without authentication requirements on D-Link DIR-412 A1-1.14WW routers. An attacker can clear the router's log file via act=clear&logtype=sysact to log_clear.php, which could be used to erase attack traces.
An issue discovered on D-Link DIR-615 devices with firmware version 20.05 and 20.07. wan.htm can be accessed directly without authentication, which can lead to disclosure of information about the WAN, and can also be leveraged by an attacker to modify the data fields of the page.
IBM Planning Analytics Local 2.0 and 2.1 connects to a MongoDB server. MongoDB, a document-oriented database system, is listening on the remote port, and it is configured to allow connections without password authentication. A remote attacker can gain unauthorized access to the database. IBM X-Force ID: 292420.
A vulnerability in the REST API endpoint of Cisco Vision Dynamic Signage Director could allow an unauthenticated, remote attacker to bypass authentication on an affected device. The vulnerability is due to missing authentication on some of the API calls. An attacker could exploit this vulnerability by sending a request to one of the affected calls. A successful exploit could allow the attacker to interact with some parts of the API.
In versions of Couchbase Server prior to 5.0, the bucket named "default" was a special bucket that allowed read and write access without authentication. As part of 5.0, the behavior of all buckets including "default" were changed to only allow access by authenticated users with sufficient authorization. However, users were allowed unauthenticated and unauthorized access to the "default" bucket if the properties of this bucket were edited. This has been fixed in versions 5.1.0 and 5.5.0.
An issue was discovered in LibreNMS through 1.47. A number of scripts import the Authentication libraries, but do not enforce an actual authentication check. Several of these scripts disclose information or expose functions that are of a sensitive nature and are not expected to be publicly accessible.
An issue was discovered in Simmeth Lieferantenmanager before 5.6. An attacker can make various API calls without authentication because the password in a Credential Object is not checked.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
Broken Access Control in User Authentication in Avaya Scopia Pathfinder 10 and 20 PTS version 8.3.7.0.4 allows remote unauthenticated attackers to bypass the login page, access sensitive information, and reset user passwords via URL modification.
PraisonAI is a multi-agent teams system. In versions below 4.5.139 of PraisonAI and 1.5.140 of praisonaiagents, the browser bridge (praisonai browser start) is vulnerable to unauthenticated remote session hijacking due to missing authentication and a bypassable origin check on its /ws WebSocket endpoint. The server binds to 0.0.0.0 by default and only validates the Origin header when one is present, meaning any non-browser client that omits the header is accepted without restriction. An unauthenticated network attacker can connect, send a start_session message, and the server will route it to the first idle browser-extension WebSocket (effectively hijacking that session) and then broadcast all resulting automation actions and outputs back to the attacker. This enables unauthorized remote control of connected browser automation sessions, leakage of sensitive page context and automation results, and misuse of model-backed browser actions in any environment where the bridge is network-reachable. This issue has been fixed in versions 4.5.139 of PraisonAI and 1.5.140 of praisonaiagents.
An issue was discovered in SquareBox CatDV Server through 9.2. An attacker can invoke sensitive RMI methods such as getConnections without authentication, the results of which can be used to generate valid authentication tokens. These tokens can then be used to invoke administrative tasks within the application, such as disclosing password hashes.
A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.
Unauthenticated functionality in CoolerControl/coolercontrold <4.0.0 allows unauthenticated attackers to view and modify potentially sensitive data via HTTP requests
PraisonAI is a multi-agent teams system. Prior to version 4.5.97, the PraisonAI Gateway server accepts WebSocket connections at /ws and serves agent topology at /info with no authentication. Any network client can connect, enumerate registered agents, and send arbitrary messages to agents and their tool sets. This issue has been patched in version 4.5.97.
Multiple vulnerabilities in Cisco Application Services Engine could allow an unauthenticated, remote attacker to gain privileged access to host-level operations or to learn device-specific information, create diagnostic files, and make limited configuration changes. For more information about these vulnerabilities, see the Details section of this advisory.
OneUptime is an open-source monitoring and observability platform. Prior to version 10.0.42, unauthenticated access to Notification test and Phone Number management endpoints allows SMS/Call/Email/WhatsApp abuse and phone number purchase. This issue has been patched in version 10.0.42.
LoLLMs WEBUI provides the Web user interface for Lord of Large Language and Multi modal Systems. A critical Server-Side Request Forgery (SSRF) vulnerability has been identified in all known existing versions of `lollms-webui`. The `@router.post("/api/proxy")` endpoint allows unauthenticated attackers to force the server into making arbitrary GET requests. This can be exploited to access internal services, scan local networks, or exfiltrate sensitive cloud metadata (e.g., AWS/GCP IAM tokens). As of time of publication, no known patched versions are available.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause access to manipulate and read specific files in the IGSS project report directory, potentially leading to a denial-of-service condition when an attacker sends specific messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)
IBM FlashSystem (IBM Storage Virtualize (8.5.0.0 through 8.5.0.13, 8.5.1.0, 8.5.2.0 through 8.5.2.3, 8.5.3.0 through 8.5.3.1, 8.5.4.0, 8.6.0.0 through 8.6.0.5, 8.6.1.0, 8.6.2.0 through 8.6.2.1, 8.6.3.0, 8.7.0.0 through 8.7.0.2, 8.7.1.0, 8.7.2.0 through 8.7.2.1) could allow a remote attacker to bypass RPCAdapter endpoint authentication by sending a specifically crafted HTTP request.
An authentication bypass in the Palo Alto Networks PAN-OS software enables an unauthenticated attacker with network access to the management web interface to bypass the authentication otherwise required by the PAN-OS management web interface and invoke certain PHP scripts. While invoking these PHP scripts does not enable remote code execution, it can negatively impact integrity and confidentiality of PAN-OS. You can greatly reduce the risk of this issue by restricting access to the management web interface to only trusted internal IP addresses according to our recommended best practices deployment guidelines https://live.paloaltonetworks.com/t5/community-blogs/tips-amp-tricks-how-to-secure-the-management-access-of-your-palo/ba-p/464431 . This issue does not affect Cloud NGFW or Prisma Access software.
Envoy is a cloud-native high-performance proxy. In versions prior to 1.22.1 the OAuth filter implementation does not include a mechanism for validating access tokens, so by design when the HMAC signed cookie is missing a full authentication flow should be triggered. However, the current implementation assumes that access tokens are always validated thus allowing access in the presence of any access token attached to the request. Users are advised to upgrade. There is no known workaround for this issue.
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
Missing authentication for critical function vulnerability in iSCSI management functionality in Synology DiskStation Manager (DSM) before 7.1-42661 allows remote attackers to read or write arbitrary files via unspecified vectors.
OpenClaw versions prior to 2026.2.21 sandbox browser entrypoint launches x11vnc without authentication for noVNC observer sessions, allowing unauthenticated access to the VNC interface. Remote attackers on the host loopback interface can connect to the exposed noVNC port to observe or interact with the sandbox browser without credentials.
Incorrect Authorization vulnerability in the protocol communication between the WatchGuard Authentication Gateway (aka Single Sign-On Agent) on Windows and the WatchGuard Single Sign-On Client on Windows and MacOS allows Authentication Bypass.This issue affects the Authentication Gateway: through 12.10.2; Windows Single Sign-On Client: through 12.7; MacOS Single Sign-On Client: through 12.5.4.
User can access /plugin api without authentication. This issue affected Apache ShenYu 2.4.0 and 2.4.1.
Missing Authentication for Critical Function in temi Robox OS prior to 120, temi Android app up to 1.3.7931 allows remote attackers to receive and answer calls intended for another temi user. Answering the call this way grants motor control of the temi in addition to audio/video via unspecified vectors.
Missing authentication for critical function in Azure MCP Server allows an unauthorized attacker to disclose information over a network.
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data.
Xvfb of SAP Business Objects Business Intelligence Platform, versions - 4.2, 4.3, platform on Unix does not perform any authentication checks for functionalities that require user identity.
Saho’s attendance devices ADM100 and ADM-100FP have insufficient authentication. An unauthenticated remote attacker can exploit this vulnerability to bypass authentication to read system information and operate user's data, but can’t control system or disrupt service.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by incorrect access control. Lack of access control on the web manger pages allows any user to view and modify information.
Tad Web is vulnerable to authorization bypass, thus remote attackers can exploit the vulnerability to use the original function of viewing bulletin boards and uploading files in the system.
ERP is a free and open source Enterprise Resource Planning tool. In versions up to 15.98.0 and 16.0.0-rc.1 and through 16.6.0, certain endpoints lacked access validation which allowed for unauthorized document access. This issue has been fixed in versions 15.98.1 and 16.6.1.
In JetBrains Hub before 2025.3.119807 authentication bypass allowing administrative actions was possible