Denbun by NEOJAPAN Inc. (Denbun POP version V3.3P R4.0 and earlier, Denbun IMAP version V3.3I R4.0 and earlier) uses hard-coded credentials, which may allow remote attackers to read/send mail or change the configuration.
A vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which the web service contains a hidden system account with a hardcoded password. An attacker can use this information to log into the system with high-privilege credentials.
The National Payments Corporation of India BHIM application 1.3 for Android relies on three hardcoded strings (AK-NPCIMB, IM-NPCIBM, and VK-NPCIBM) for SMS validation, which makes it easier for attackers to bypass authentication.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The use of password hash instead of password for authentication vulnerability was identified, which could allow a malicious user to bypass authentication without obtaining the actual password.
EMC Data Protection Advisor 6.3.x before patch 67 and 6.4.x before patch 130 contains undocumented accounts with hard-coded passwords and various privileges. Affected accounts are: "Apollo System Test", "emc.dpa.agent.logon" and "emc.dpa.metrics.logon". An attacker with knowledge of the password could potentially use these accounts via REST APIs to gain unauthorized access to EMC Data Protection Advisor (including potentially access with administrative privileges).
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
A hard-coded account named 'upgrade' in Fortinet FortiWLM 8.3.0 and lower versions allows a remote attacker to log-in and execute commands with 'upgrade' account privileges.
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database.
In some circumstances, an F5 BIG-IP version 12.0.0 to 12.1.2 and 13.0.0 Azure cloud instance may contain a default administrative password which could be used to remotely log into the BIG-IP system. The impacted administrative account is the Azure instance administrative user that was created at deployment. The root and admin accounts are not vulnerable. An attacker may be able to remotely access the BIG-IP host via SSH.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
An issue was discovered in Veritas NetBackup Before 8.0 and NetBackup Appliance Before 3.0. NetBackup Cloud Storage Service uses a hardcoded username and password.
The Data Warehouse component in NetApp OnCommand Insight before 7.2.3 allows remote attackers to obtain administrative access by leveraging a default privileged account.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a world-readable axess/opt/axXMPPHandler/config/xmpp_config.py file that stores hardcoded credentials.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axiros password for the root account.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the cloud1234 password for the a1@chopin account default credentials.
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded adminpldt / z6dUABtl270qRxt7a2uGTiw credentials for an ISP.
SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).
EMC ESRS Policy Manager prior to 6.8 contains an undocumented account (OpenDS admin) with a default password. A remote attacker with the knowledge of the default password may login to the system and gain administrator privileges to the local LDAP directory server.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
mcollective has a default password set at install
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
The installation of Microsoft Exchange 2000 before Rev. A creates a user account with a known password, which could allow attackers to gain privileges, aka the "Exchange User Account" vulnerability.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no password allowing an attacker into the system without authentication.
Toshiba Home gateway HEM-GW16A firmware HEM-GW16A-FW-V1.2.0 and earlier, Toshiba Home gateway HEM-GW26A firmware HEM-GW26A-FW-V1.2.0 and earlier uses hard-coded credentials, which may allow attackers to perform operations on device with administrative privileges.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axzyxel password for the livedbuser account.
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the wbboEZ4BN3ssxAfM hardcoded password for the debian-sys-maint account.
Unsafe storage of AD credentials in Ivanti DSM netinst 5.1 due to a static, hard-coded encryption key.
An issue was discovered in heinekingmedia StashCat through 1.7.5 for Android. The keystore is locked with a hard-coded password. Therefore, everyone with access to the keystore can read the content out, for example the private key of the user.
Use of Hard-coded Credentials vulnerability in GoodWe Technologies Co., Ltd. GW1500‑XS allows anyone in physical proximity to the device to fully access the web interface of the inverter via Wi‑Fi.This issue affects GW1500‑XS: 1.1.2.1.
A vulnerability was found in demozx gf_cms 1.0/1.0.1. It has been classified as critical. This affects the function init of the file internal/logic/auth/auth.go of the component JWT Authentication. The manipulation leads to hard-coded credentials. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 1.0.2 is able to address this issue. The patch is named be702ada7cb6fdabc02689d90b38139c827458a5. It is recommended to upgrade the affected component.
Arkeia Network Backup Client 5.x contains hard-coded credentials that effectively serve as a back door, which allows remote attackers to access the file system and possibly execute arbitrary commands.
An issue was discovered in TitanHQ WebTitan before 5.18. It has a hidden support account (with a hard-coded password) in the web administration interface, with administrator privileges. Anybody can log in with this account.
A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been classified as very critical. This affects an unknown part. The manipulation leads to weak authentication. It is possible to initiate the attack remotely.
The ZyXEL P660HN-T1A v2 TCLinux Fw #7.3.37.6 router distributed by TrueOnline has three user accounts with default passwords, including two hardcoded service accounts: one with the username true and password true, and another with the username supervisor and password zyad1234. These accounts can be used to login to the web interface, exploit authenticated command injections, and change router settings for malicious purposes.
admin.php in SmartSiteCMS 1.0 allows remote attackers to bypass authentication and gain administrator privileges by setting the userName cookie.
FreeSWITCH 1.6.10 through 1.10.1 has a default password in event_socket.conf.xml.
D-Link DGS-1500 Ax devices before 2.51B021 have a hardcoded password, which allows remote attackers to obtain shell access.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. The binary file /usr/local/sbin/webproject/set_param.cgi contains hardcoded credentials to the web application. Because these accounts cannot be deactivated or have their passwords changed, they are considered to be backdoor accounts.
An authentication bypass was found in an unknown area of the SiteOmat source code. All SiteOmat BOS versions are affected, prior to the submission of this exploit. Also, the SiteOmat does not force administrators to switch passwords, leaving SSH and HTTP remote authentication open to public.