The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
SolarWinds Access Rights Manager (ARM) was found to contain a hard-coded credential authentication bypass vulnerability. If exploited, this vulnerability would allow access to the RabbitMQ management console. We thank Trend Micro Zero Day Initiative (ZDI) for its ongoing partnership in coordinating with SolarWinds on responsible disclosure of this and other potential vulnerabilities.
An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
An issue was discovered in Percona XtraDB Cluster before 5.7.28-31.41.2. A bundled script inadvertently sets a static transition_key for SST processes in place of the random key expected.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
openITCOCKPIT before 3.7.3 uses the 1fea123e07f730f76e661bced33a94152378611e API key rather than generating a random API Key for WebSocket connections.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials.
Intumit SmartRobot uses a fixed encryption key for authentication. Remote attackers can use this key to encrypt a string composed of the user's name and timestamp to generate an authentication code. With this authentication code, they can obtain administrator privileges and subsequently execute arbitrary code on the remote server using built-in system functionality.
An issue was discovered in Yealink Configuration Encrypt Tool (AES version) and Yealink Configuration Encrypt Tool (RSA version before 1.2). There is a single hardcoded key (used to encrypt provisioning documents) across customers' installations.
D-LINK Go-RT-AC750 GORTAC750_A1_FW_v101b03 has a hardcoded password for the Alphanetworks account, which allows remote attackers to obtain root access via a telnet session.
Hard-coded credentials in FOLIO mod-data-export-spring versions before 1.5.4 and from 2.0.0 to 2.0.2 allows unauthenticated users to access critical APIs, modify user data, modify configurations including single-sign-on, and manipulate fees/fines.
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, the product uses hard-coded credentials, which may allow an attacker to connect to a specific port.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
An issue was discovered on FiberHome HG6245D devices through RP2613. The password for the enable command is gpon.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded gestiontelebucaramanga / t3l3buc4r4m4ng42013 credentials for an ISP.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.
FreePBX is an open source IP PBX. From 15.0.42 to before 16.0.45 and 17.0.7, unauthenticated users may be able to access the User Control Panel (UCP) using hard-coded initial template credentials if these were not immediately changed by the Administrator who enabled UCP. Authenticated access to ACP is required for the initial setup of UCP generic templates, but after that, without further steps by the admin, unauthenticated users may be able to gain access. This vulnerability is fixed in 16.0.45 and 17.0.7.
In ScadaBR version 1.2.0, a Use of Hard-Coded Credentials vulnerability could allow an attacker to access the SCADA system as admin.
Taiko AG1000-01A SMS Alert Gateway Rev 7.3 and Rev 8 contains a hard-coded credential vulnerability in the embedded web configuration interface where authentication is implemented entirely in client-side JavaScript in login.zhtml, exposing static plaintext credentials in the page source. Unauthenticated attackers with network access can recover administrative credentials directly from the client-side validate() function to obtain full administrative access to the device.
ENENSYS IPGuard v2 2.10.0 was discovered to contain hardcoded credentials.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to read, manipulate and create entries in the managed database.
D-Link DPH-400S/SE VoIP Phone v1.01 contains hardcoded provisioning variables, including PROVIS_USER_PASSWORD, which may expose sensitive user credentials. An attacker with access to the firmware image can extract these credentials using static analysis tools such as strings or xxd, potentially leading to unauthorized access to device functions or user accounts. This vulnerability exists due to insecure storage of sensitive information in the firmware binary.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
In ZKT ZKBio CVSecurity 6.4.1_R an unauthenticated attacker can craft JWT token using the hardcoded secret to authenticate to the service console. NOTE: the Supplier disputes the significance of this report because the service console is typically only accessible from a local area network, and because access to the service console does not result in login access or data access in the context of the application software platform.
DoraCMS 2.1.8 is vulnerable to Use of Hard-coded Cryptographic Key.
UNI-NMS-Lite uses hard-coded credentials that could allow an unauthenticated attacker to gain administrative privileges to all UNI-NMS managed devices.
A vulnerability in Cisco Smart Licensing Utility (CSLU) could allow an unauthenticated, remote attacker to log into an affected system by using a static administrative credential. This vulnerability is due to an undocumented static user credential for an administrative account. An attacker could exploit this vulnerability by using the static credentials to login to the affected system. A successful exploit could allow the attacker to login to the affected system with administrative rights over the CSLU application API.
Jinan USR IOT Technology Limited (PUSR) USR-W610 RS232/485 to Wi-Fi/Ethernet Converter device firmware contains plaintext administrative credentials embedded in the firmware image. These credentials can be extracted through firmware analysis and used to authenticate to device services.
By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.
The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.
Yarbo firmware v2.3.9 contains hardcoded administrative credentials embedded in the firmware image. These credentials are identical across all devices running this firmware and cannot be changed or removed by end users, enabling trivial unauthorized access to device management interfaces by anyone who knows them.
The CS5000 Fire Panel is vulnerable due to a hard-coded password that runs on a VNC server and is visible as a string in the binary responsible for running VNC. This password cannot be altered, allowing anyone with knowledge of it to gain remote access to the panel. Such access could enable an attacker to operate the panel remotely, potentially putting the fire panel into a non-functional state and causing serious safety issues.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
D-Link DGS-1100 devices with Rev.B firmware 1.01.018 have a hardcoded SSL private key, which allows man-in-the-middle attackers to spoof devices by hijacking an HTTPS session.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
REINER timeCard 6.05.07 installs a Microsoft SQL Server with an sa password that is hardcoded in the TCServer.jar file.
Hard-coded ASP.NET/IIS machineKey value in Digital Knowledge KnowledgeDeliver deployments prior to February 24, 2026 allows adversaries to circumvent ViewState validation mechanisms and achieve remote code execution via malicious ViewState deserialization attacks
The upload.cgi binary, responsible for processing device backups, contains a hardcoded AES encryption key. This allows an attacker to decrypt, modify, and re-encrypt system backups, facilitating persistent backdoor injection.