A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `ssid` and `ssid_hex` configuration parameters, as used within the `testWifiAP` XCMD handler
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `wpapsk` configuration parameter, as used within the `testWifiAP` XCMD handler
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` configuration parameter, as used within the `testWifiAP` XCMD handler
A format string injection vulnerability exists in the ghome_process_control_packet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z and 6.9X. A specially-crafted XCMD can lead to memory corruption, information disclosure and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability.
An OS command injection vulnerability exists in the XCMD setAlexa functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. A specially-crafted XCMD can lead to arbitrary command execution. An attacker can send a malicious XML payload to trigger this vulnerability.
A stack-based buffer overflow vulnerability exists in the XCMD setIPCam functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to remote code execution. An attacker can send a malicious XML payload to trigger this vulnerability.
An OS command injection vulnerability exists in the console_main_loop :sys functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. A specially-crafted XCMD can lead to arbitrary command execution. An attacker can send an XML payload to trigger this vulnerability.
An OS command injection vulnerability exists in the web interface util_set_serial_mac functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can send an HTTP request to trigger this vulnerability.
A format string injection vulnerability exists in the XCMD getVarHA functionality of abode systems, inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to memory corruption, information disclosure, and denial of service. An attacker can send a malicious XML payload to trigger this vulnerability.
An OS command injection vulnerability exists in the XCMD setUPnP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to arbitrary command execution. An attacker can send a malicious XML payload to trigger this vulnerability.
An os command injection vulnerability exists in the web interface util_set_abode_code functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can send an HTTP request to trigger this vulnerability.
An authentication bypass vulnerability exists in the GHOME control functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted network request can lead to arbitrary XCMD execution. An attacker can send a malicious XML payload to trigger this vulnerability.
Four format string injection vulnerabilities exist in the XCMD testWifiAP functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. Specially-crafted configuration values can lead to memory corruption, information disclosure and denial of service. An attacker can modify a configuration value and then execute an XCMD to trigger these vulnerabilities.This vulnerability arises from format string injection via the `default_key_id` and `key` configuration parameters, as used within the `testWifiAP` XCMD handler
An OS command injection vulnerability exists in the XCMD doDebug functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted XCMD can lead to arbitrary command execution. An attacker can send a malicious XML payload to trigger this vulnerability.
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
DataEase is an open source data visualization analysis tool. Prior to 2.10.2, DataEase allows attackers to forge jwt and take over services. The JWT secret is hardcoded in the code, and the UID and OID are hardcoded. The vulnerability has been fixed in v2.10.2.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
Use of Hard-coded Credentials vulnerability in ABB ASPECT-Enterprise, ABB NEXUS Series, ABB MATRIX Series.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*.
SunGrow iSolarCloud Android application V2.1.6.20241017 and prior contains hardcoded credentials. The application (regardless of the user account) and the cloud uses the same MQTT credentials for exchanging the device telemetry.
NUUO v03.11.00 was discovered to contain access control issue.
IBM Security Verify Access Appliance 10.0.0 through 10.0.8 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
Dell RecoverPoint for Virtual Machines 6.0.x contains use of hard-coded credentials vulnerability. A Remote unauthenticated attacker could potentially exploit this vulnerability by gaining access to the source code, easily retrieving these secrets and reusing them to access the system leading to gaining access to unauthorized data.
Hard-coded credentials in AmosConnect 8 allow remote attackers to gain full administrative privileges, including the ability to execute commands on the Microsoft Windows host platform with SYSTEM privileges by abusing AmosConnect Task Manager.
mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.
An authentication bypass issue in FormaLMS <= 2.4.4 allows an attacker to bypass the authentication mechanism and obtain a valid access to the platform.
First Corporation's DVRs use a hard-coded password, which may allow a remote unauthenticated attacker to rewrite or obtain the configuration information of the affected device. Note that updates are provided only for Late model of CFR-4EABC, CFR-4EAB, CFR-8EAB, CFR-16EAB, MD-404AB, and MD-808AB. As for the other products, apply the workaround.
Gradio is an open-source Python library to build machine learning and data science demos and web applications. Versions prior to 3.13.1 contain Use of Hard-coded Credentials. When using Gradio's share links (i.e. creating a Gradio app and then setting `share=True`), a private SSH key is sent to any user that connects to the Gradio machine, which means that a user could access other users' shared Gradio demos. From there, other exploits are possible depending on the level of access/exposure the Gradio app provides. This issue is patched in version 3.13.1, however, users are recommended to update to 3.19.1 or later where the FRP solution has been properly tested.
ECOA BAS controller is vulnerable to hard-coded credentials within its Linux distribution image, thus remote attackers can obtain administrator’s privilege without logging in.
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
The firmware of EDIMAX IC-3140W Version 3.11 is hardcoded with Administrator username and password.
A hard coded password in Super Store Finder v3.6 allows attackers to access the administration panel.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
D-Link DVX-2000MS contains hard-coded credentials for undocumented user accounts in the '/etc/passwd' file. As weak passwords have been used, the plaintext passwords can be recovered from the hash values.
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
A vulnerability in the key-based SSH authentication mechanism of Cisco Policy Suite could allow an unauthenticated, remote attacker to log in to an affected system as the root user. This vulnerability is due to the re-use of static SSH keys across installations. An attacker could exploit this vulnerability by extracting a key from a system under their control. A successful exploit could allow the attacker to log in to an affected system as the root user.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A Hardcoded JWT Secret Key in metadata.py in AdaptiveScale LXDUI through 2.1.3 allows attackers to gain admin access to the host system.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
The web application for ProGauge MAGLINK LX4 CONSOLE contains an administrative-level user account with a password that cannot be changed.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
Multiple MachineSense devices have credentials unable to be changed by the user or administrator.
IBM Security Identity Manager 7.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 171511.
H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.