CODESYS V2 runtime system SP before 2.4.7.55 has a Stack-based Buffer Overflow.
The Package Manager of CODESYS Development System 3 before 3.5.17.0 does not check the validity of packages before installation and may be used to install CODESYS packages with malicious content.
CODESYS V2 Web-Server before 1.1.9.20 has an Out-of-bounds Write.
CODESYS V2 Web-Server before 1.1.9.20 has a Stack-based Buffer Overflow.
CODESYS V2 Web-Server before 1.1.9.20 has an Improperly Implemented Security Check.
CODESYS V2 Web-Server before 1.1.9.20 has Improper Access Control.
In CODESYS Gateway Server V2 for versions prior to V2.3.9.38 only a part of the the specified password is been compared to the real CODESYS Gateway password. An attacker may perform authentication by specifying a small password that matches the corresponding part of the longer real CODESYS Gateway password.
A unsafe deserialization vulnerability exists in the ObjectManager.plugin ProfileInformation.ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
A unsafe deserialization vulnerability exists in the ComponentModel ComponentManager.StartupCultureSettings functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
A unsafe deserialization vulnerability exists in the PackageManagement.plugin ExtensionMethods.Clone() functionality of CODESYS GmbH CODESYS Development System 3.5.16. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow.
An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System.
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
An unsafe deserialization vulnerability exists in the ObjectManager.plugin ObjectStream.ProfileByteArray functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
CODESYS Automation Server before 1.16.0 allows cross-site request forgery (CSRF).
CODESYS V2.3 ENI server up to V3.2.2.24 has a Buffer Overflow.
A unsafe deserialization vulnerability exists in the ComponentModel Profile.FromFile() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
An unsafe deserialization vulnerability exists in the Engine.plugin ProfileInformation ProfileData functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
3S-Smart Software Solutions GmbH CODESYS V3 Library Manager, all versions prior to 3.5.16.0, allows the system to display active library content without checking its validity, which may allow the contents of manipulated libraries to be displayed or executed. The issue also exists for source libraries, but 3S-Smart Software Solutions GmbH strongly recommends distributing compiled libraries only.
An unsafe deserialization vulnerability exists in the ObjectManager.plugin Project.get_MissingTypes() functionality of CODESYS GmbH CODESYS Development System 3.5.16 and 3.5.17. A specially crafted file can lead to arbitrary command execution. An attacker can provide a malicious file to trigger this vulnerability.
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
In multiple products of CODESYS v3 in multiple versions a remote low privileged user could utilize this vulnerability to read and modify system files and OS resources or DoS the device.
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
FUXA is a web-based Process Visualization (SCADA/HMI/Dashboard) software. An insecure default configuration in FUXA allows an unauthenticated, remote attacker to gain administrative access and execute arbitrary code on the server. This affects FUXA through version 1.2.9 when authentication is enabled, but the administrator JWT secret is not configured. This issue has been patched in FUXA version 1.2.10.
Projects using the SUSE Virtualization (Harvester) environment may expose the OS default ssh login password if they are using the 1.5.x or 1.6.x interactive installer to either create a new cluster or add new hosts to an existing cluster. The environment is not affected if the PXE boot mechanism is utilized along with the Harvester configuration setup.
The default configuration of broker.conf in Red Hat OpenShift Enterprise 2.x before 2.1 has a password of "mooo" for a Mongo account, which allows remote attackers to hijack the broker by providing this password, related to the openshift.sh script in Openshift Extras before 20130920. NOTE: this may overlap CVE-2013-4253 and CVE-2013-4281.
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Undocumented Default Cryptographic Key Vulnerability in Cohesity DataPlatform version 6.3 prior 6.3.1g, 6.4 up to 6.4.1c and 6.5.1 through 6.5.1b. The ssh key can provide an attacker access to the linux system in the affected version.
HAXcms with nodejs backend allows users to start the server in any HAXsite or HAXcms instance. In versions 11.0.6 and below, the NodeJS version of HAXcms uses an insecure default configuration designed for local development. The default configuration does not perform authorization or authentication checks. If a user were to deploy haxcms-nodejs without modifying the default settings, ‘HAXCMS_DISABLE_JWT_CHECKS‘ would be set to ‘true‘ and their deployment would lack session authentication. This is fixed in version 11.0.7.
Dell EMC Integrated System for Microsoft Azure Stack Hub, versions 1906 – 2011, contain an undocumented default iDRAC account. A remote unauthenticated attacker, with the knowledge of the default credentials, could potentially exploit this to log in to the system to gain root privileges.
Donetick an open-source app for managing tasks and chores. Prior to version 0.1.44, the application uses JSON Web Tokens (JWT) for authentication, but the signing secret has a weak default value. While the responsibility is left to the system administrator to change it, this approach is inadequate. The vulnerability is proven by existence of the issue in the live version as well. This issue can result in full account takeover of any user. Version 0.1.44 contains a patch.
A vulnerability in the BluStar component of Mitel InAttend 2.6 SP4 through 2.7 and CMG 8.5 SP4 through 8.6 could allow access to sensitive information, changes to the system configuration, or execution of arbitrary commands within the context of the system.
In Apache CouchDB prior to 3.2.2, an attacker can access an improperly secured default installation without authenticating and gain admin privileges. The CouchDB documentation has always made recommendations for properly securing an installation, including recommending using a firewall in front of all CouchDB installations.
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
MiR robot controllers (central computation unit) makes use of Ubuntu 16.04.2 an operating system, Thought for desktop uses, this operating system presents insecure defaults for robots. These insecurities include a way for users to escalate their access beyond what they were granted via file creation, access race conditions, insecure home directory configurations and defaults that facilitate Denial of Service (DoS) attacks.
GitHub Electron 1.7.15, 1.8.7, 2.0.7, and 3.0.0-beta.6, in certain scenarios involving IFRAME elements and "nativeWindowOpen: true" or "sandbox: true" options, is affected by a WebPreferences vulnerability that can be leveraged to perform remote code execution.
Session Validation attacks in Apache Superset versions up to and including 2.0.1. Installations that have not altered the default configured SECRET_KEY according to installation instructions allow for an attacker to authenticate and access unauthorized resources. This does not affect Superset administrators who have changed the default value for SECRET_KEY config. All superset installations should always set a unique secure random SECRET_KEY. Your SECRET_KEY is used to securely sign all session cookies and encrypting sensitive information on the database. Add a strong SECRET_KEY to your `superset_config.py` file like: SECRET_KEY = <YOUR_OWN_RANDOM_GENERATED_SECRET_KEY> Alternatively you can set it with `SUPERSET_SECRET_KEY` environment variable.
IBM Fusion 2.2.0 through 2.10.1, IBM Fusion HCI 2.2.0 through 2.10.0, and IBM Fusion HCI for watsonx 2.8.2 through 2.10.0 uses insecure default configurations that could expose AMQStreams without client authentication that could allow an attacker to perform unauthorized actions.
EMC Elastic Cloud Storage (ECS) before 3.1 is affected by an undocumented account vulnerability that could potentially be leveraged by malicious users to compromise the affected system.
A vulnerability in Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points running Cisco Mobility Express Software could allow an unauthenticated, remote attacker to take complete control of an affected device. The vulnerability is due to the existence of default credentials for an affected device that is running Cisco Mobility Express Software, regardless of whether the device is configured as a master, subordinate, or standalone access point. An attacker who has layer 3 connectivity to an affected device could use Secure Shell (SSH) to log in to the device with elevated privileges. A successful exploit could allow the attacker to take complete control of the device. This vulnerability affects Cisco Aironet 1830 Series and Cisco Aironet 1850 Series Access Points that are running an 8.2.x release of Cisco Mobility Express Software prior to Release 8.2.111.0, regardless of whether the device is configured as a master, subordinate, or standalone access point. Release 8.2 was the first release of Cisco Mobility Express Software for next generation Cisco Aironet Access Points. Cisco Bug IDs: CSCva50691.
VITEC Exterity IPTV products through 2021-04-30 allow privilege escalation to root.
Raspberry Pi OS through 5.10 has the raspberry default password for the pi account. If not changed, attackers can gain administrator privileges.
The HEIDENHAIN Controller TNC 640 NC software Version 340590 07 SP5, is vulnerable to improper authentication in its DNC communication for CNC machines. Authentication is not enabled by default for DNC communication. This vulnerability may allow an attacker to deny service on the production line, steal sensitive data from the production line, and alter any products created by the production line. Note: CNC machines running the TNC 640 controller require DNC to be enabled for DNC communication to be present.
The Versa Director software exposes a number of services by default and allow attackers an easy foothold due to default credentials and multiple accounts (most with sudo access) that utilize the same default credentials. By default, Versa director exposes ssh and postgres to the internet, alongside a host of other services. Versa Networks is not aware of any reported instance where this vulnerability was exploited. Proof of concept for this vulnerability has been disclosed by third party security researchers. Workarounds or Mitigation: Versa recommends the following security controls: 1) Change default passwords to complex passwords 2) Passwords must be complex with at least 8 characters that comprise of upper case, and lower case alphabets, as well as at at least one digit, and one special character 3) Passwords must be changed at least every 90 days 4) Password change history is checked to ensure that the at least the last 5 passwords must be used when changing password. 5) Review and audit logs for all authentication attempts to check for unauthorized/suspicious login attempts and enforce remediation steps.
Multiple vulnerabilities in the web-based management interface of the Cisco Catalyst Passive Optical Network (PON) Series Switches Optical Network Terminal (ONT) could allow an unauthenticated, remote attacker to perform the following actions: Log in with a default credential if the Telnet protocol is enabled Perform command injection Modify the configuration For more information about these vulnerabilities, see the Details section of this advisory.
The Orca HCM digital learning platform uses a weak factory default administrator password, which is hard-coded in the source code of the webpage in plain text, thus remote attackers can obtain administrator’s privilege without logging in.
A condition exists in FlashArray Purity whereby a local account intended for initial array configuration remains active potentially allowing a malicious actor to gain elevated privileges.
A flaw was found in servicemesh-operator. The NetworkPolicy resources installed for Maistra do not properly specify which ports may be accessed, allowing access to all ports on these resources from any pod. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.