mySCADA myPRO uses a hard-coded password which could allow an attacker to remotely execute code on the affected device.
Hardcoded default root credentials exist on the ecobee3 lite 4.5.81.200 device. This allows a threat actor to gain access to the password-protected bootloader environment through the serial console.
Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to an attacker obtaining user login credentials and control the system.
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded trueadmin / admintrue credentials for an ISP.
In TOTOLINK A3002R TOTOLINK-A3002R-He-V1.1.1-B20200824.0128 in the shadow.sample file, root is hardcoded in the firmware.
An issue was discovered on FiberHome HG6245D devices through RP2613. The telnet daemon on port 23/tcp can be abused with the gpon/gpon credentials.
MegaRAC Default Credentials Vulnerability
An issue was discovered on FiberHome HG6245D devices through RP2613. The web daemon contains the hardcoded admin / 888888 credentials for an ISP.
A specific file on the sERP server if Kyungrinara(ERP solution) has a fixed password with the SYSTEM authority. This vulnerability could allow attackers to leak or steal sensitive information or execute malicious commands.
IBM Flexible Service Processor (FSP) FW860.00 through FW860.B3, FW950.00 through FW950.C0, FW1030.00 through FW1030.61, FW1050.00 through FW1050.21, and FW1060.00 through FW1060.10 has static credentials which may allow network users to gain service privileges to the FSP.
Use of hard-coded credentials for the telnet server of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote unauthenticated attacker to execute an arbitrary OS command.
An issue was discovered on FiberHome AN5506-04-FA devices with firmware RP2631. There is a gepon password for the gepon account.
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
A hard-coded cryptographic key is used by Altium Enterprise Server to sign file download URLs in the Vault service. Because the key is identical across all installations, an unauthenticated network attacker who can reach the server can forge valid download signatures and retrieve files from the Vault storage area without any authentication, session, or credentials. A separate path traversal vulnerability in the same download endpoint allows the configured storage root to be escaped, enabling reads of arbitrary files on the server filesystem. Combined, these issues allow an unauthenticated attacker to obtain sensitive server configuration and key material, which can lead to full server compromise. The vulnerability can be chained with CVE-2026-9152 to enumerate and bulk-download stored content. Altium 365 cloud deployments are not impacted in practice, as file storage uses object storage rather than the local filesystem.
PrismX MX100 AP controller developed by BROWAN COMMUNICATIONS has a Use of Hard-coded Credentials vulnerability, allowing unauthenticated remote attackers to log in to the database using hardcoded database credentials stored in the firmware.
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
Novel-Plus v3.6.2 was discovered to contain a hard-coded JWT key located in the project config file. This vulnerability allows attackers to create a custom user session.
Totolink A3600R_Firmware V4.1.2cu.5182_B20201102 contains a hard code password for root in /etc/shadow.sample.
TOTOLINK A3002RU V3.0.0-B20220304.1804 has a hardcoded password for root in /etc/shadow.sample.
An authentication bypass vulnerability exists in FileWave before 14.6.3 and 14.7.x before 14.7.2. Exploitation could allow an unauthenticated actor to gain access to the system with the highest authority possible and gain full control over the FileWave platform.
This vulnerability allows remote attackers to bypass authentication on affected installations of Vinchin Backup and Recovery 6.5.0.17561. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of the MySQL server. The server uses a hard-coded password for the administrator user. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17139.
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
Hardcoded JWT Secret in AgileConfig <1.6.8 Server allows remote attackers to use the generated JWT token to gain administrator access.
The iRM-IEI Remote Management developed by IEI Integration Corp has a Hardcoded Credentials vulnerability, allowing unauthenticated remote attackers to exploit hard-coded credentials to gain administrative privileges on the database.
The Yarbo Android and iOS applications contain hard-coded MQTT broker credentials that are identical for all users and all devices. These credentials are embedded in the application binary and are readily extractable via APK decompilation. The credentials provide access to cloud MQTT brokers carrying real-time telemetry for the entire global Yarbo robot fleet. They allow both wildcard subscription to all robot telemetry topics and publishing to any robot's command topic using only the robot's serial number.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
Prolink router PRS1841 was discovered to contain hardcoded credentials for its Telnet and FTP services.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
Dell EMC SCG Policy Manager, versions from 5.10 to 5.12, contain(s) a contain a Hard-coded Cryptographic Key vulnerability. An attacker with the knowledge of the hard-coded sensitive information, could potentially exploit this vulnerability to login to the system to gain admin privileges.
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
An issue was discovered in TitanFTP (aka Titan FTP) NextGen before 1.2.1050. There is Remote Code Execution due to a hardcoded password for the sa account on the Microsoft SQL Express 2019 instance installed by default during TitanFTP NextGen installation, aka NX-I674 (sub-issue 1). NOTE: as of 2022-06-21, the 1.2.1050 release corrects this vulnerability in a new installation, but not in an upgrade installation.
Certain models of D-Link wireless routers do not properly validate user input in the telnet service, allowing unauthenticated remote attackers to use hard-coded credentials to log into telnet and inject arbitrary OS commands, which can then be executed on the device.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
OMICARD EDM has a hard-coded machine key. An unauthenticated remote attacker can use the machine key to send serialized payload to the server to execute arbitrary code, manipulate system data and disrupt service.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. The binary file /usr/local/sbin/webproject/set_param.cgi contains hardcoded credentials to the web application. Because these accounts cannot be deactivated or have their passwords changed, they are considered to be backdoor accounts.
Bitnami Cassandra container images are affected by a retained default superuser vulnerability. When a custom administrator account is configured via the CASSANDRA_USER environment variable, the container initialization script creates the new superuser account but fails to drop the built-in cassandra account in certain scenarios. This leaves the default cassandra:cassandra superuser active as an unintended access path. Affected versions — Container image: 4.0.x prior to 4.0.20-photon-5-r7; 4.1.x prior to 4.1.11-photon-5-r7; 5.0.x prior to 5.0.8-photon-5-r4 / 5.0.8-debian-12-r3.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
FreePBX is an open source IP PBX. From 15.0.42 to before 16.0.45 and 17.0.7, unauthenticated users may be able to access the User Control Panel (UCP) using hard-coded initial template credentials if these were not immediately changed by the Administrator who enabled UCP. Authenticated access to ACP is required for the initial setup of UCP generic templates, but after that, without further steps by the admin, unauthenticated users may be able to gain access. This vulnerability is fixed in 16.0.45 and 17.0.7.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for the telnet service stored in the component /web_cste/cgi-bin/product.ini.
H3C R3010 v100R002L02 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.