Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-1000

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-27 Apr, 2024 | 09:00
Updated At-02 Aug, 2024 | 05:32
Rejected At-
Credits

cyanomiko dcnnt-py Notification notifications.py main command injection

A vulnerability was found in cyanomiko dcnnt-py up to 0.9.0. It has been classified as critical. Affected is the function main of the file dcnnt/plugins/notifications.py of the component Notification Handler. The manipulation leads to command injection. It is possible to launch the attack remotely. Upgrading to version 0.9.1 is able to address this issue. The patch is identified as b4021d784a97e25151a5353aa763a741e9a148f5. It is recommended to upgrade the affected component. VDB-262230 is the identifier assigned to this vulnerability.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:27 Apr, 2024 | 09:00
Updated At:02 Aug, 2024 | 05:32
Rejected At:
▼CVE Numbering Authority (CNA)
cyanomiko dcnnt-py Notification notifications.py main command injection

A vulnerability was found in cyanomiko dcnnt-py up to 0.9.0. It has been classified as critical. Affected is the function main of the file dcnnt/plugins/notifications.py of the component Notification Handler. The manipulation leads to command injection. It is possible to launch the attack remotely. Upgrading to version 0.9.1 is able to address this issue. The patch is identified as b4021d784a97e25151a5353aa763a741e9a148f5. It is recommended to upgrade the affected component. VDB-262230 is the identifier assigned to this vulnerability.

Affected Products
Vendor
cyanomiko
Product
dcnnt-py
Modules
  • Notification Handler
Versions
Affected
  • 0.1
  • 0.2
  • 0.3
  • 0.4
  • 0.5
  • 0.6
  • 0.7
  • 0.8
  • 0.9
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Command Injection
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Command Injection
Metrics
VersionBase scoreBase severityVector
3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
3.06.3MEDIUM
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
2.06.5N/A
AV:N/AC:L/Au:S/C:P/I:P/A:P
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Version: 3.0
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Version: 2.0
Base score: 6.5
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

tool
VulDB GitHub Commit Analyzer
Timeline
EventDate
Advisory disclosed2023-08-14 00:00:00
Countermeasure disclosed2023-08-14 00:00:00
VulDB entry created2024-04-27 02:00:00
VulDB entry last update2024-04-27 10:51:27
Event: Advisory disclosed
Date: 2023-08-14 00:00:00
Event: Countermeasure disclosed
Date: 2023-08-14 00:00:00
Event: VulDB entry created
Date: 2024-04-27 02:00:00
Event: VulDB entry last update
Date: 2024-04-27 10:51:27
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.262230
vdb-entry
technical-description
https://vuldb.com/?ctiid.262230
signature
permissions-required
https://github.com/cyanomiko/dcnnt-py/pull/23
issue-tracking
https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5
patch
https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1
patch
Hyperlink: https://vuldb.com/?id.262230
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/?ctiid.262230
Resource:
signature
permissions-required
Hyperlink: https://github.com/cyanomiko/dcnnt-py/pull/23
Resource:
issue-tracking
Hyperlink: https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5
Resource:
patch
Hyperlink: https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1
Resource:
patch
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/?id.262230
vdb-entry
technical-description
x_transferred
https://vuldb.com/?ctiid.262230
signature
permissions-required
x_transferred
https://github.com/cyanomiko/dcnnt-py/pull/23
issue-tracking
x_transferred
https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5
patch
x_transferred
https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1
patch
x_transferred
Hyperlink: https://vuldb.com/?id.262230
Resource:
vdb-entry
technical-description
x_transferred
Hyperlink: https://vuldb.com/?ctiid.262230
Resource:
signature
permissions-required
x_transferred
Hyperlink: https://github.com/cyanomiko/dcnnt-py/pull/23
Resource:
issue-tracking
x_transferred
Hyperlink: https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5
Resource:
patch
x_transferred
Hyperlink: https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1
Resource:
patch
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:27 Apr, 2024 | 09:15
Updated At:04 Jun, 2024 | 19:17

A vulnerability was found in cyanomiko dcnnt-py up to 0.9.0. It has been classified as critical. Affected is the function main of the file dcnnt/plugins/notifications.py of the component Notification Handler. The manipulation leads to command injection. It is possible to launch the attack remotely. Upgrading to version 0.9.1 is able to address this issue. The patch is identified as b4021d784a97e25151a5353aa763a741e9a148f5. It is recommended to upgrade the affected component. VDB-262230 is the identifier assigned to this vulnerability.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.16.3MEDIUM
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Secondary2.06.5MEDIUM
AV:N/AC:L/Au:S/C:P/I:P/A:P
Type: Secondary
Version: 3.1
Base score: 6.3
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
Type: Secondary
Version: 2.0
Base score: 6.5
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:S/C:P/I:P/A:P
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-77Primarycna@vuldb.com
CWE ID: CWE-77
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5cna@vuldb.com
N/A
https://github.com/cyanomiko/dcnnt-py/pull/23cna@vuldb.com
N/A
https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1cna@vuldb.com
N/A
https://vuldb.com/?ctiid.262230cna@vuldb.com
N/A
https://vuldb.com/?id.262230cna@vuldb.com
N/A
Hyperlink: https://github.com/cyanomiko/dcnnt-py/commit/b4021d784a97e25151a5353aa763a741e9a148f5
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://github.com/cyanomiko/dcnnt-py/pull/23
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://github.com/cyanomiko/dcnnt-py/releases/tag/0.9.1
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?ctiid.262230
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/?id.262230
Source: cna@vuldb.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

452Records found

CVE-2024-7440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.49% / 80.87%
||
7 Day CHG~0.00%
Published-03 Aug, 2024 | 16:31
Updated-07 Aug, 2024 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Vivotek CC8160 upload_file.cgi getenv command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. It has been classified as critical. This affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. It is possible to initiate the attack remotely. The identifier VDB-273525 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

Action-Not Available
Vendor-vivotekVivotek
Product-cc8160cc8160_firmwareCC8160
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.57% / 68.21%
||
7 Day CHG~0.00%
Published-03 Aug, 2024 | 18:00
Updated-06 Aug, 2024 | 17:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Vivotek SD9364 upload_file.cgi getenv command injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

Action-Not Available
Vendor-vivotekVivotek
Product-sd9364_firmwaresd9364SD9364
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-7160
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-3.59% / 87.59%
||
7 Day CHG~0.00%
Published-28 Jul, 2024 | 15:00
Updated-08 Aug, 2024 | 11:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3700R cstecgi.cgi setWanCfg command injection

A vulnerability classified as critical has been found in TOTOLINK A3700R 9.1.2u.5822_B20200513. Affected is the function setWanCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument hostName leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-272574 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-a3700ra3700r_firmwareA3700Ra3700r_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2647
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.28% / 84.50%
||
7 Day CHG~0.00%
Published-11 May, 2023 | 07:31
Updated-02 Aug, 2024 | 06:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Weaver E-Office File Upload utility_all.php command injection

A vulnerability was found in Weaver E-Office 9.5 and classified as critical. Affected by this issue is some unknown functionality of the file /webroot/inc/utility_all.php of the component File Upload Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-228776. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-weaverWeaver
Product-e-officeE-Office
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-5355
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.19% / 78.65%
||
7 Day CHG~0.00%
Published-26 May, 2024 | 06:00
Updated-01 Mar, 2025 | 01:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
anji-plus AJ-Report IGroovyHandler command injection

A vulnerability, which was classified as critical, has been found in anji-plus AJ-Report up to 1.4.1. This issue affects the function IGroovyHandler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-266267.

Action-Not Available
Vendor-anji-plusanji-plusanji-plus
Product-aj-reportAJ-Reportreport
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-2378
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.02% / 77.07%
||
7 Day CHG~0.00%
Published-28 Apr, 2023 | 16:00
Updated-02 Aug, 2024 | 06:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Ubiquiti EdgeRouter X Web Management Interface command injection

A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Management Interface. The manipulation of the argument suffix-rate-up leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-227654 is the identifier assigned to this vulnerability.

Action-Not Available
Vendor-Ubiquiti Inc.
Product-er-xer-x_firmwareer-x-sfp_firmwareer-x-sfpEdgeRouter X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5836
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.05% / 83.67%
||
7 Day CHG+0.25%
Published-07 Jun, 2025 | 13:31
Updated-09 Jun, 2025 | 19:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9 POST Request SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC9 15.03.02.13. It has been rated as critical. This issue affects the function formSetIptv of the file /goform/SetIPTVCfg of the component POST Request Handler. The manipulation of the argument list leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac9_firmwareac9AC9
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5515
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.71% / 82.11%
||
7 Day CHG-0.03%
Published-03 Jun, 2025 | 17:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formMapDel command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X2000R 1.0.0-B20230726.1108. Affected by this issue is some unknown functionality of the file /boafrm/formMapDel. The manipulation of the argument devicemac1 leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5606
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.51% / 81.01%
||
7 Day CHG+0.19%
Published-04 Jun, 2025 | 19:00
Updated-10 Jun, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5441
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.46%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5439
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.11% / 77.92%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5446
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.46%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5502
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-4.18% / 88.55%
||
7 Day CHG-0.05%
Published-03 Jun, 2025 | 14:00
Updated-06 Jun, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 formMapReboot command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x15x15_firmwareX15
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-5443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.35%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-20527
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-6||MEDIUM
EPSS-0.23% / 45.45%
||
7 Day CHG~0.00%
Published-19 Apr, 2021 | 16:20
Updated-16 Sep, 2024 | 22:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IBM Resilient SOAR V38.0 could allow a privileged user to create create malicious scripts that could be executed as another user. IBM X-Force ID: 198759.

Action-Not Available
Vendor-IBM Corporation
Product-resilientResilient OnPrem
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5504
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.85% / 82.81%
||
7 Day CHG-0.04%
Published-03 Jun, 2025 | 14:31
Updated-04 Jun, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X2000R formWsc command injection

A vulnerability has been found in TOTOLINK X2000R 1.0.0-B20230726.1108 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWsc. The manipulation of the argument peerRptPin leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-X2000R
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.46%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5492
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 35.79%
||
7 Day CHG+0.02%
Published-03 Jun, 2025 | 10:31
Updated-15 Jul, 2025 | 17:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-500WF-WT /usr/sbin/jhttpd msp_info.htm sub_456DE8 command injection

A vulnerability has been found in D-Link DI-500WF-WT up to 20250511 and classified as critical. Affected by this vulnerability is the function sub_456DE8 of the file /msp_info.htm?flag=cmd of the component /usr/sbin/jhttpd. The manipulation of the argument cmd leads to command injection. The attack can be launched remotely.

Action-Not Available
Vendor-D-Link Corporation
Product-di-500wf-wt_firmwaredi-500wf-wtDI-500WF-WT
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5444
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.35%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.11% / 77.92%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9603
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.31%
||
7 Day CHG~0.00%
Published-29 Aug, 2025 | 01:32
Updated-11 Sep, 2025 | 12:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Telesquare TLR-2005KSH internet.cgi command injection

A vulnerability was determined in Telesquare TLR-2005KSH 1.2.4. The affected element is an unknown function of the file /cgi-bin/internet.cgi?Command=lanCfg. Executing manipulation of the argument Hostname can lead to command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-telesquareTelesquare
Product-tlr-2005kshtlr-2005ksh_firmwareTLR-2005KSH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5145
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.46% / 63.65%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 05:31
Updated-11 Jul, 2025 | 09:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore POWER13 Query String cgi-bin command injection

A vulnerability, which was classified as critical, was found in Netcore NBR1005GPEV2, B6V2, COVER5, NAP830, NAP930, NBR100V2, NBR200V2 and POWER13 up to 20250508. This affects an unknown part of the file /www/cgi-bin/ of the component Query String Handler. The manipulation leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-B6V2NAP930NBR100V2NBR1005GPEV2NBR200V2COVER5NAP830POWER13
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5147
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.42%
||
7 Day CHG~0.00%
Published-25 May, 2025 | 11:31
Updated-29 May, 2025 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netcore NBR1005GPEV2/NBR200V2/B6V2 network_tools tools_ping command injection

A vulnerability was found in Netcore NBR1005GPEV2, NBR200V2 and B6V2 up to 20250508 and classified as critical. This issue affects the function tools_ping of the file /usr/bin/network_tools. The manipulation of the argument url leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Netcore
Product-NBR1005GPEV2NBR200V2B6V2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4999
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.49% / 65.39%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-29184
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-5.29% / 89.88%
||
7 Day CHG~0.00%
Published-20 May, 2022 | 19:25
Updated-23 Apr, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection/Argument Injection in GoCD

GoCD is a continuous delivery server. In GoCD versions prior to 22.1.0, it is possible for existing authenticated users who have permissions to edit or create pipeline materials or pipeline configuration repositories to get remote code execution capability on the GoCD server via configuring a malicious branch name which abuses Mercurial hooks/aliases to exploit a command injection weakness. An attacker would require access to an account with existing GoCD administration permissions to either create/edit (`hg`-based) configuration repositories; create/edit pipelines and their (`hg`-based) materials; or, where "pipelines-as-code" configuration repositories are used, to commit malicious configuration to such an external repository which will be automatically parsed into a pipeline configuration and (`hg`) material definition by the GoCD server. This issue is fixed in GoCD 22.1.0. As a workaround, users who do not use/rely upon Mercurial materials can uninstall/remove the `hg`/Mercurial binary from the underlying GoCD Server operating system or Docker image.

Action-Not Available
Vendor-thoughtworksgocd
Product-gocdgocd
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-88
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
CVE-2025-5000
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.49% / 65.39%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi control_panel_sw command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000. It has been classified as critical. This affects the function control_panel_sw of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument filename leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4851
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.16% / 78.44%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 03:31
Updated-24 May, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi setUploadUserData command injection

A vulnerability classified as critical was found in TOTOLINK N300RH 6.1c.1390_B20191101. This vulnerability affects the function setUploadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4849
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.16% / 78.44%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 02:31
Updated-24 May, 2025 | 00:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4850
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.73% / 72.45%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 03:00
Updated-24 May, 2025 | 00:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi setUnloadUserData command injection

A vulnerability classified as critical has been found in TOTOLINK N300RH 6.1c.1390_B20191101. This affects the function setUnloadUserData of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument plugin_name leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4729
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.59% / 68.90%
||
7 Day CHG-0.14%
Published-15 May, 2025 | 23:31
Updated-20 Jun, 2025 | 14:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK A3002R/A3002RU HTTP POST Request formMapDelDevice command injection

A vulnerability was found in TOTOLINK A3002R and A3002RU 3.0.0-B20230809.1615. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the file /boafrm/formMapDelDevice of the component HTTP POST Request Handler. The manipulation of the argument macstr leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-a3002rua3002ru_firmwarea3002ra3002r_firmwareA3002RA3002RU
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.48% / 64.90%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44846
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.96% / 92.95%
||
7 Day CHG+5.24%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA600-PoE V5.3c.6665_B20180820 was found to contain a command injection vulnerability in the recvUpgradeNewFw function via the fwUrl parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca600-poeca600-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44864
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.81%
||
7 Day CHG+7.85%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the module parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44837
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.96% / 92.95%
||
7 Day CHG+5.24%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CPE CP900 V6.3c.1144_B20190715 was discovered to contain a command injection vulnerability in the CloudSrvUserdataVersionCheck function via the url or magicid parameters. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 49.57%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4454
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 49.57%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44854
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.96% / 92.95%
||
7 Day CHG+5.24%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CP900 V6.3c.1144_B20190715 was found to contain a command injection vulnerability in the setUpgradeUboot function via the FileName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44867
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.81%
||
7 Day CHG+7.85%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetNetCheckTools function via the hostName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44865
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.81%
||
7 Day CHG+7.85%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the enable parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44847
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.88% / 92.90%
||
7 Day CHG+5.20%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA600-PoE V5.3c.6665_B20180820 was found to contain a command injection vulnerability in the setWebWlanIdx function via the webWlanIdx parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca600-poeca600-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-28935
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.2||HIGH
EPSS-9.66% / 92.80%
||
7 Day CHG~0.00%
Published-06 Jul, 2022 | 12:24
Updated-03 Aug, 2024 | 06:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Totolink A830R V5.9c.4729_B20191112, Totolink A3100R V4.1.2cu.5050_B20200504, Totolink A950RG V4.1.2cu.5161_B20200903, Totolink A800R V4.1.2cu.5137_B20200730, Totolink A3000RU V5.9c.5185_B20201128, Totolink A810R V4.1.2cu.5182_B20201026 were discovered to contain a command injection vulnerability.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a3000rua950rg_firmwarea950rga800r_firmwarea3100ra3000ru_firmwarea830ra800ra830r_firmwarea810ra810r_firmwarea3100r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44835
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-6.38% / 90.88%
||
7 Day CHG+4.42%
Published-01 May, 2025 | 00:00
Updated-28 May, 2025 | 16:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link DIR-816 A2V1.1.0B05 was found to contain a command injection in iptablesWebsFilterRun, which allows remote attackers to execute arbitrary commands via shell.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-816_a2dir-816_a2_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44861
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.96% / 92.95%
||
7 Day CHG+5.24%
Published-01 May, 2025 | 00:00
Updated-21 May, 2025 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CA300-POE V6.2c.884_B20180522 was found to contain a command injection vulnerability in the CloudSrvUserdataVersionCheck function via the url parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ca300-poeca300-poe_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.26% / 49.57%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44866
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-12.49% / 93.81%
||
7 Day CHG+7.85%
Published-01 May, 2025 | 00:00
Updated-27 May, 2025 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W20E V15.11.0.6 was found to contain a command injection vulnerability in the formSetDebugCfg function via the level parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w20ew20e_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44838
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-9.96% / 92.95%
||
7 Day CHG+5.24%
Published-01 May, 2025 | 00:00
Updated-22 May, 2025 | 15:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK CPE CP900 V6.3c.1144_B20190715 was discovered to contain a command injection vulnerability in the setUploadUserData function via the FileName parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTOTOLINK
Product-cp900_firmwarecp900n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4341
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.34% / 79.87%
||
7 Day CHG+0.97%
Published-06 May, 2025 | 08:31
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-880L Request Header ssdpcgi sub_16570 command injection

A vulnerability classified as critical was found in D-Link DIR-880L up to 104WWb01. Affected by this vulnerability is the function sub_16570 of the file /htdocs/ssdpcgi of the component Request Header Handler. The manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-880l_firmwaredir-880lDIR-880L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.45% / 84.99%
||
7 Day CHG+1.92%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4076
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.15% / 78.32%
||
7 Day CHG~0.00%
Published-29 Apr, 2025 | 18:00
Updated-02 May, 2025 | 13:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
LB-LINK BL-AC3600 Password lighttpd.cgi easy_uci_set_option_string_0 command injection

A vulnerability classified as critical has been found in LB-LINK BL-AC3600 up to 1.0.22. This affects the function easy_uci_set_option_string_0 of the file /cgi-bin/lighttpd.cgi of the component Password Handler. The manipulation of the argument routepwd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-LB-LINK
Product-BL-AC3600
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.81% / 82.62%
||
7 Day CHG~0.00%
Published-30 Apr, 2025 | 14:00
Updated-13 May, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 cmd_wireless command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been declared as critical. Affected by this vulnerability is the function cmd_wireless. The manipulation of the argument host leads to command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • ...
  • 9
  • 10
  • Next
Details not found