A vulnerability was found in anji-plus AJ-Report up to 1.4.1. It has been declared as critical. Affected by this vulnerability is the function getValueFromJs of the component Javascript Handler. The manipulation leads to deserialization. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-266263.
A vulnerability was found in anji-plus AJ-Report up to 1.4.1. It has been rated as critical. Affected by this issue is the function validationRules of the component com.anjiplus.template.gaea.business.modules.datasetparam.controller.DataSetParamController#verification. The manipulation leads to deserialization. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-266264.
Report v0.9.8.6 was discovered to contain a Server-Side Request Forgery (SSRF) vulnerability.
anji-plus AJ-Report is affected by an authentication bypass vulnerability. A remote and unauthenticated attacker can append ";swagger-ui" to HTTP requests to bypass authentication and execute arbitrary Java on the victim server.
A vulnerability, which was classified as critical, was found in anji-plus AJ-Report up to 1.4.1. Affected is an unknown function of the file /dataSet/testTransform;swagger-ui. The manipulation of the argument dynSentence leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-266268.
A vulnerability classified as critical has been found in anji-plus AJ-Report up to 1.4.1. This affects the function decompress of the component ZIP File Handler. The manipulation leads to path traversal. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-266265 was assigned to this vulnerability.
A vulnerability was found in anji-plus AJ-Report up to 1.4.1. It has been classified as critical. Affected is the function pageList of the file /pageList. The manipulation of the argument p leads to sql injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-266262 is the identifier assigned to this vulnerability.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects GC108P before 1.0.8.2, GC108PP before 1.0.8.2, GS108Tv3 before 7.0.7.2, GS110TPv3 before 7.0.7.2, GS110TPP before 7.0.7.2, GS110TUP before 1.0.5.3, GS710TUP before 1.0.5.3, GS308T before 1.0.3.2, GS310TP before 1.0.3.2, GS710TUP before 1.0.5.3, GS716TP before 1.0.4.2, GS716TPP before 1.0.4.2, GS724TPP before 2.0.6.3, GS724TPv2 before 2.0.6.3, GS724TPP before 2.0.6.3, GS728TPPv2 before 6.0.8.2, GS728TPv2 before 6.0.8.2, GS752TPv2 before 6.0.8.2, GS752TPP before 6.0.8.2, GS750E before 1.0.1.10, MS510TXM before 1.0.4.2, and MS510TXUP before 1.0.4.2.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R7800 before 1.0.2.74, R9000 before 1.0.5.2, and XR500 before 2.3.2.66.
TOTOLINK X6000R v9.4.0cu.652_B20230116 was discovered to contain a command execution vulnerability via the sub_415258 function.
NETGEAR RAX5 (AX1600 WiFi Router) V1.0.2.26 was discovered to contain a command injection vulnerability via the ifname parameter in the apcli_cancel_wps function.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function upgrade_filter. This vulnerability allows attackers to execute arbitrary commands via the path and time parameters.
D-Link device DIR_878_FW1.30B08_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
tinyfiledialogs (aka tiny file dialogs) before 3.15.0 allows shell metacharacters (such as a backquote or a dollar sign) in titles, messages, and other input data. NOTE: this issue exists because of an incomplete fix for CVE-2020-36767, which only considered single and double quote characters.
Code Injection vulnerability in EasyVirt DCScope <= 8.6.0 and CO2Scope <= 1.3.0 allows remote unauthenticated attackers to execute arbitrary code to /api/license/sendlicense/.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
A command injection vulnerability in the Command Dispatcher Service of NASA Fprime v3.4.3 allows attackers to execute arbitrary commands.
SeaCMS <=13.0 is vulnerable to command execution in phome.php via the function Ebak_RepPathFiletext().
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, R7000 before 1.0.11.110, R7100LG before 1.0.0.72, R7900 before 1.0.4.30, R8000 before 1.0.4.62, XR300 before 1.0.3.56, R7000P before 1.3.2.132, R8500 before 1.0.2.144, R6900P before 1.3.2.132, and R8300 before 1.0.2.144.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12.
D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the LocalIPAddress parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
An issue was discovered on Securifi Almond, Almond+, and Almond 2015 devices with firmware AL-R096. The device provides a user with the capability of adding new port forwarding rules to the device. It seems that the POST parameters passed in this request to set up routes on the device can be set in such a way that would result in passing commands to a "system" API in the function and thus result in command injection on the device. If the firmware version AL-R096 is dissected using binwalk tool, we obtain a cpio-root archive which contains the filesystem set up on the device that contains all the binaries. The binary "goahead" is the one that has the vulnerable function that recieves the values sent by the POST request. If we open this binary in IDA-pro we will notice that this follows a MIPS little endian format. The function sub_43C280in IDA pro is identified to be receiving the values sent in the POST request and the value set in POST parameter "ip_address" is extracted at address 0x0043C2F0. The POST parameter "ipaddress" is concatenated at address 0x0043C958 and this is passed to a "system" function at address 0x00437284. This allows an attacker to provide the payload of his/her choice and finally take control of the device.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects XR300 before 1.0.3.68, R7000P before 1.3.3.140, and R6900P before 1.3.3.140.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function NTPSyncWithHost. This vulnerability allows attackers to execute arbitrary commands via the parameter host_time.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function uploadPicture. This vulnerability allows attackers to execute arbitrary commands via the pic_name parameter.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7000 before 1.0.11.126, R6900P before 1.3.2.126, and R7000P before 1.3.2.126.
A vulnerability in the ClearPass Policy Manager web-based management interface allows remote authenticated users to run arbitrary commands on the underlying host. Successful exploit could allow an attacker to execute arbitrary commands as a lower privileged user on the underlying operating system.
D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR1020 before 2.6.3.58, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RBS50Y before 2.7.3.22, WNR2000v5 before 1.0.0.76, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, RAX10 before 1.0.2.88, RAX120 before 1.2.0.16, RAX70 before 1.0.2.88, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, R6700AX before 1.0.2.88, RAX120v2 before 1.2.0.16, RAX78 before 1.0.2.88, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR350 before 4.3.4.7, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS350 before 4.3.4.7, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK352 before 4.3.4.7, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
A Command injection vulnerability exists in Tenda AC10U AC1200 Smart Dual-band Wireless Router AC10U V1.0 Firmware V15.03.06.49_multi via the setUsbUnload functionality. The vulnerability is caused because the client controlled "deviceName" value is passed directly to the "doSystemCmd" function.
Apache kylin checks the legitimacy of the project before executing some commands with the project name passed in by the user. There is a mismatch between what is being checked and what is being used as the shell command argument in DiagnosisService. This may cause an illegal project name to pass the check and perform the following steps, resulting in a command injection vulnerability. This issue affects Apache Kylin 4.0.0.
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function msp_info.htm. This vulnerability allows attackers to execute arbitrary commands via the cmd parameter.
The Screensavercc component in eLux RP before 5.5.0 allows attackers to bypass intended configuration restrictions and execute arbitrary commands with root privileges by inserting commands in a local configuration dialog in the control panel.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.64, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RAX120 before 1.2.0.16, RBS50Y before 1.0.0.56, WNR2000v5 before 1.0.0.76, XR450 before 2.3.2.114, XR500 before 2.3.2.114, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, EX6410 before 1.0.0.134, RBR10 before 2.6.1.44, RBR20 before 2.6.2.104, RBR40 before 2.6.2.104, RBR50 before 2.7.2.102, EX6420 before 1.0.0.134, RBS10 before 2.6.1.44, RBS20 before 2.6.2.104, RBS40 before 2.6.2.104, RBS50 before 2.7.2.102, EX6400v2 before 1.0.0.134, RBK12 before 2.6.1.44, RBK20 before 2.6.2.104, RBK40 before 2.6.2.104, and RBK50 before 2.7.2.102.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D6200 before 1.1.00.40, D7000 before 1.0.1.78, R6020 before 1.0.0.42, R6080 before 1.0.0.42, R6050 before 1.0.1.26, JR6150 before 1.0.1.26, R6120 before 1.0.0.66, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.64, R6800 before 1.2.0.62, R6700v2 before 1.2.0.62, R6900v2 before 1.2.0.62, R7450 before 1.2.0.62, AC2100 before 1.2.0.62, AC2400 before 1.2.0.62, AC2600 before 1.2.0.62, and WNR2020 before 1.1.0.62.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900P before 1.4.2.84, R7960P before 1.4.2.84, and R8000P before 1.4.2.84.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStaticRouteSettings. This vulnerability allows attackers to execute arbitrary commands via the staticroute_list parameter.
NETGEAR D6220 devices before 1.0.0.76 are affected by command injection by an authenticated user.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects AC2100 before 1.2.0.88, AC2400 before 1.2.0.88, AC2600 before 1.2.0.88, D7000 before 1.0.1.82, R6220 before 1.1.0.110, R6230 before 1.1.0.110, R6260 before 1.1.0.84, R6330 before 1.1.0.84, R6350 before 1.1.0.84, R6700v2 before 1.2.0.88, R6800 before 1.2.0.88, R6850 before 1.1.0.84, R6900v2 before 1.2.0.88, R7200 before 1.2.0.88, R7350 before 1.2.0.88, R7400 before 1.2.0.88, and R7450 before 1.2.0.88.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects LBR20 before 2.6.3.50, RBS50Y before 2.7.3.22, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
The Symantec Messaging Gateway before 10.6.3-267 can encounter an issue of remote code execution, which describes a situation whereby an individual may obtain the ability to execute commands remotely on a target machine or in a target process. In this type of occurrence, after gaining access to the system, the attacker may attempt to elevate their privileges.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection').
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects D7800 before 1.0.1.60, DM200 before 1.0.0.66, EX2700 before 1.0.1.56, EX6150v2 before 1.0.1.86, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.128, EX6400 before 1.0.2.144, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6420 before 1.0.0.128, EX7300 before 1.0.2.144, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, R7500v2 before 1.0.3.46, R7800 before 1.0.2.74, R8900 before 1.0.5.26, R9000 before 1.0.5.2, RAX120 before 1.0.1.128, WN3000RPv2 before 1.0.0.78, WN3000RPv3 before 1.0.2.80, WNR2000v5 before 1.0.0.74, XR500 before 2.3.2.66, RBK20 before 2.7.3.22, RBR20 before 2.7.3.22, RBS20 before 2.7.3.22, RBK40 before 2.7.3.22, RBR40 before 2.7.3.22, and RBS40 before 2.7.3.22.