AMI SPx contains a vulnerability in the BMC where an Attacker may cause a use of hard-coded cryptographic key by a hard-coded certificate. A successful exploit of this vulnerability may lead to a loss of confidentiality, integrity, and availability.
TeleAdapt RoomCast TA-2400 1.0 through 3.1 suffers from Use of a Hard-coded Password (PIN): 385521, 843646, and 592671.
The Le-yan dental management system contains a hard-coded credentials vulnerability in the web page source code, which allows an unauthenticated remote attacker to acquire administrator’s privilege and control the system or disrupt service.
VinChin Backup & Recovery v5.0.*, v6.0.*, v6.7.*, and v7.0.* was discovered to contain hardcoded credentials.
MXsecurity version 1.0 is vulnearble to hardcoded credential vulnerability. This vulnerability has been reported that can be exploited to craft arbitrary JWT tokens and subsequently bypass authentication for web-based APIs.
Hard coded weak credentials in Barracuda Load Balancer 5.0.0.015.
Draytek Vigor Routers firmware versions below 3.9.6/4.2.4, Access Points firmware versions below v1.4.0, Switches firmware versions below 2.6.7, and Myvigor firmware versions below 2.3.2 were discovered to use hardcoded encryption keys which allows attackers to bind any affected device to their own account. Attackers are then able to create WCF and DrayDDNS licenses and synchronize them from the website.
Connected IO v2.1.0 and prior uses a hard-coded username/password pair embedded in their device's firmware used for device communication using MQTT. An attacker who gained access to these credentials is able to connect to the MQTT broker and send messages on behalf of devices, impersonating them. in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
Control ID IDSecure 4.7.26.0 and prior uses a hardcoded cryptographic key in order to sign and verify JWT session tokens, allowing attackers to sign arbitrary session tokens and bypass authentication.
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 256016.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
A vulnerability classified as critical was found in OTCMS up to 6.62. This vulnerability affects unknown code. The manipulation of the argument username/password with the input admin leads to use of hard-coded password. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-231508.
The Dataprobe iBoot PDU running firmware version 1.43.03312023 or earlier uses hard-coded credentials for all interactions with the internal Postgres database. A malicious agent with the ability to execute operating system commands on the device can leverage this vulnerability to read, modify, or delete arbitrary database records.
Gladinet CentreStack and Triofox prior to version 16.12.10420.56791 used hardcoded values for their implementation of the AES cryptoscheme. This degrades security for public exposed endpoints that may make use of it and may offer arbitrary local file inclusion when provided a specially crafted request without authentication. This opens the door for future exploitation and can be leveraged with previous vulnerabilities to gain a full system compromise.
An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product.
A hardcoded password was set for accounts registered using an OmniAuth provider (e.g. OAuth, LDAP, SAML) in GitLab CE/EE versions 14.7 prior to 14.7.7, 14.8 prior to 14.8.5, and 14.9 prior to 14.9.2 allowing attackers to potentially take over accounts
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
Dromara Sureness before v1.0.8 was discovered to use a hardcoded key.
Use of Hard-coded Cryptographic Key vulnerability in the WebReportsApi.dll of Exago Web Reports, as used in the Device42 Asset Management Appliance, allows an attacker to leak session IDs and elevate privileges. This issue affects: Device42 CMDB versions prior to 18.01.00.
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 has a default account with hard-coded credentials used with the FTP protocol. Baxter asserts no files can be transferred to or from the WBM using this account. Baxter has released a new version of the SIGMA Spectrum Infusion System, Version 8, which incorporates hardware and software changes.
The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.
All versions of the qBittorrent client through 4.5.5 use default credentials when the web user interface is enabled. The administrator is not forced to change the default credentials. As of 4.5.5, this issue has not been fixed. A remote attacker can use the default credentials to authenticate and execute arbitrary operating system commands using the "external program" feature in the web user interface. This was reportedly exploited in the wild in March 2023.
Dromara Lamp-Cloud before v3.8.1 was discovered to use a hardcoded cryptographic key when creating and verifying a Json Web Token. This vulnerability allows attackers to authenticate to the application via a crafted JWT token.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
The Felan Framework plugin for WordPress is vulnerable to improper authentication in versions up to, and including, 1.1.4. This is due to the hardcoded password in the 'fb_ajax_login_or_register' function and in the 'google_ajax_login_or_register' function. This makes it possible for unauthenticated attackers to log in as any existing user on the site, if they registered with facebook or google social login and did not change their password. CVE-2025-23504 is likely a duplicate of this issue.
The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
IBM Security Verify Governance 10.0 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 225222.
Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.
GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.
A security flaw has been discovered in Apeman ID71 218.53.203.117. This vulnerability affects unknown code of the file /system/www/system.ini. The manipulation results in hard-coded credentials. The attack may be performed from remote. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.
The rpWLANRedirect.asp ASP page is accessible without authentication on ZyXEL P-660HN-T1 V2 (2.00(AAKK.3)) devices. After accessing the page, the admin user's password can be obtained by viewing the HTML source code, and the interface of the modem can be accessed as admin.
QXIP SIPCAPTURE homer-app before 1.4.28 for HOMER 7.x has the same 167f0db2-f83e-4baa-9736-d56064a5b415 JWT secret key across different customers' installations.
A vulnerability, which was classified as critical, has been found in taoeffect Empress. Affected by this issue is some unknown functionality. The manipulation leads to use of hard-coded password. The patch is identified as 557e177d8a309d6f0f26de46efb38d43e000852d. It is recommended to apply a patch to fix this issue. VDB-217154 is the identifier assigned to this vulnerability.
Rocket Software UniData versions prior to 8.2.4 build 3003 and UniVerse versions prior to 11.3.5 build 1001 or 12.2.1 build 2002 suffer from an authentication bypass vulnerability, where a special username with a deterministic password can be leveraged to bypass authentication checks and execute OS commands as the root user.
An issue was discovered in GitLab Community and Enterprise Edition 12.0 through 12.1.4. It uses Hard-coded Credentials.
Linear eMerge E3-Series devices allow Remote Code Execution (root access over SSH).
mcollective has a default password set at install
Denver SHC-150 Smart Wifi Camera contains a hardcoded telnet credential vulnerability that allows unauthenticated attackers to access a Linux shell. Attackers can connect to port 23 using the default credential to execute arbitrary commands on the camera's operating system.
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
Softing FG-100 PB PROFIBUS firmware version FG-x00-PB_V2.02.0.00 contains a hardcoded password for the root account, which allows remote attackers to obtain administrative access via a TELNET session.
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
Xerox ColorCube and WorkCenter devices in 2013 had hardcoded FTP and shell user accounts.
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
International Datacasting Corporation (IDC) SFX Series SuperFlex SatelliteReceiver contains hardcoded credentials for the `monitor` account. A remote unauthenticated attacker can use these trivial, undocumented credentials to access the system via SSH. While initially dropped into a restricted shell, the attacker can trivially break out to achieve standard shell functionality.
QNAP F_VioCard 2312 and F_VioGate 2308 have hardcoded entries in authorized_keys files. NOTE: 1. All active models are not affected. The last affected model was EOL since 2010. 2. The legacy authorization mechanism is no longer adopted in all active models
The secret value used for access to critical UDS services of the MIB3 infotainment is hardcoded in the firmware. Vulnerability discovered on Škoda Superb III (3V3) - 2.0 TDI manufactured in 2022.
Intellian Aptus Web 1.24 has a hardcoded password of 12345678 for the intellian account.
PrismX MX100 AP controller developed by BROWAN COMMUNICATIONS has a Use of Hard-coded Credentials vulnerability, allowing unauthenticated remote attackers to log in to the database using hardcoded database credentials stored in the firmware.