Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled.
XMPie uStore 12.3.7244.0 allows for administrators to generate reports based on raw SQL queries. Since the application ships with default administrative credentials, an attacker may authenticate into the application and exfiltrate sensitive information from the database.
Xerox ColorQube 8580 was discovered to contain an access control issue which allows attackers to print, view the status, and obtain sensitive information.
On Xerox AltaLink B8045/B8055/B8065/B8075/B8090 and C8030/C8035/C8045/C8055/C8070 multifunction printers with software releases before 101.00x.099.28200, portions of the drive containing executable code were not encrypted thus leaving it open to potential cryptographic information disclosure.
Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, and 7970i devices before 073.xxx.086.15410 do not properly escape parameters in the support/remoteUI/configrui.php script, which can allow an unauthenticated attacker to execute OS commands on the device.
An issue was discovered in certain Xerox WorkCentre products. They do not properly encrypt passwords. This affects 3655, 3655i, 58XX, 58XXi 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) did not implement account lockout. Local account credentials may be extracted from the device via brute force guessing attacks.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the Authentication Cookie of the web application that would allow an attacker to execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the attributes parser of the IPP service. This would allow an unauthenticated attacker to cause a Denial of Service (DoS) and potentially execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by one or more stack-based buffer overflow vulnerabilities in the Google Cloud Print implementation that would allow an unauthenticated attacker to execute arbitrary code on the device. This was caused by an insecure handling of the register parameters, because the size used within a memcpy() function, which copied the action value into a local variable, was not checked properly.
Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allows attackers to modify certain configuration settings via unspecified vectors involving the "TFTP/BOOTP auto configuration option."
Unspecified vulnerability in the Scan-to-mailbox feature in Xerox WorkCentre and WorkCentre Pro before 12.060.17.000, 13.x before 13.060.17.000, and 14.x before 14.060.17.000 allows remote attackers to download certain files via unspecified vectors.
Unspecified vulnerability in the Network Controller in Xerox WorkCentre 6400 System Software 060.070.109.11407 through 060.070.109.29510, and Net Controller 060.079.11410 through 060.079.29310, allows remote attackers to access "directory structure" via a crafted PostScript file, aka "Unauthorized Directory Structure Access Vulnerability."
Multiple unspecified vulnerabilities in the Network Controller and Web Server in Xerox WorkCentre 5632, 5638, 5645, 5655, 5665, 5675, and 5687 allow remote attackers to (1) access mailboxes via unknown vectors that bypass Scan to Mailbox authorization or (2) read device configuration information via via unknown vectors that bypass web server authorization.
In Xerox FreeFlow Core version 8.0.4, an attacker can exploit a Path Traversal vulnerability to access unauthorized files on the server. This can lead to Remote Code Execution (RCE), allowing the attacker to run arbitrary commands on the system.
An issue was discovered on Xerox WorkCentre 3655, 3655i, 58XX, 58XXi, 59XX, 59XXi, 6655, 6655i, 72XX, 72XXi, 78XX, 78XXi, 7970, 7970i, EC7836, and EC7856 devices before R18-05 073.xxx.0487.15000. There is a Local File Inclusion vulnerability.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 allows remote attackers to execute arbitrary code through a buffer overflow in Web page parameter handling.
Xerox AltaLink B80xx before 103.008.020.23120, C8030/C8035 before 103.001.020.23120, C8045/C8055 before 103.002.020.23120 and C8070 before 103.003.020.23120 has several SQL injection vulnerabilities.
Xerox AtlaLink B8045/B8055/B8065/B8075/B8090 C8030/C8035/C8045/C8055/C8070 printers with software before 101.00x.089.22600 allow an attacker to gain privileges.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the request parser of the IPP service. This would allow an unauthenticated attacker to cause a Denial of Service (DoS) and potentially execute arbitrary code on the device.
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) were affected by a buffer overflow vulnerability in the Content-Type HTTP Header of the web application that would allow an attacker to execute arbitrary code on the device.
Pre-Auth RCE via Path Traversal
Pre-Auth RCE via Path Traversal
Xerox Phaser 4622 v35.013.01.000 was discovered to contain a buffer overflow in the function sub_3226AC via the TIMEZONE variable. This vulnerability allows attackers to cause a Denial of Service (DoS) via crafted overflow data.
Xerox Phaser 6510 before 64.61.23 and 64.59.11 (Bridge), WorkCentre 6515 before 65.61.23 and 65.59.11 (Bridge), VersaLink B400 before 37.61.23 and 37.59.01 (Bridge), B405 before 38.61.23 and 38.59.01 (Bridge), B600/B610 before 32.61.23 and 32.59.01 (Bridge), B605/B615 before 33.61.23 and 33.59.01 (Bridge), B7025/30/35 before 58.61.23 and 58.59.11 (Bridge), C400 before 67.61.23 and 67.59.01 (Bridge), C405 before 68.61.23 and 68.59.01 (Bridge), C500/C600 before 61.61.23 and 61.59.01 (Bridge), C505/C605 before 62.61.23 and 62.59.11 (Bridge), C7000 before 56.61.23 and 56.59.01 (Bridge), C7020/25/30 before 57.61.23 and 57.59.01 (Bridge), C8000/C9000 before 70.61.23 and 70.59.01 (Bridge), allows remote attackers with "a weaponized clone file" to execute arbitrary commands in the Web User Interface.
Xerox Phaser 6510 before 64.65.51 and 64.59.11 (Bridge), WorkCentre 6515 before 65.65.51 and 65.59.11 (Bridge), VersaLink B400 before 37.65.51 and 37.59.01 (Bridge), B405 before 38.65.51 and 38.59.01 (Bridge), B600/B610 before 32.65.51 and 32.59.01 (Bridge), B605/B615 before 33.65.51 and 33.59.01 (Bridge), B7025/30/35 before 58.65.51 and 58.59.11 (Bridge), C400 before 67.65.51 and 67.59.01 (Bridge), C405 before 68.65.51 and 68.59.01 (Bridge), C500/C600 before 61.65.51 and 61.59.01 (Bridge), C505/C605 before 62.65.51 and 62.59.01 (Bridge), C7000 before 56.65.51 and 56.59.01 (Bridge), C7020/25/30 before 57.65.51 and 57.59.01 (Bridge), C8000/C9000 before 70.65.51 and 70.59.01 (Bridge), C8000W before 72.65.51 have a remote Command Execution vulnerability in the Web User Interface that allows remote attackers with "a weaponized clone file" to execute arbitrary commands.
luci-app-lucky v2.8.3 was discovered to contain hardcoded credentials.
DragonWave Horizon 1.01.03 wireless radios have hardcoded login credentials (such as the username of energetic and password of wireless) meant to allow the vendor to access the devices. These credentials can be used in the web interface or by connecting to the device via TELNET. This is fixed in recent versions including 1.4.8.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default panger123 password for the suma123 account for certain old firmware.
On the TP-Link TL-SG108E 1.0, there is a hard-coded ciphering key (a long string beginning with Ei2HNryt). This affects the 1.1.2 Build 20141017 Rel.50749 firmware.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer supported.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. The firmware image contains encrypted passwords that are used to authenticate users wishing to access a diagnostics or password-recovery menu. Using the hardcoded cryptographic key found elsewhere in the firmware, these passwords can be decrypted. This is related to fds_sys_passDebugPasswd_ret() and fds_sys_passRecoveryPasswd_ret() in libfds.so.0.0.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
Tenda i29V1.0 V1.0.0.5 was discovered to contain a hardcoded password for root.
TOTOLINK CP900L v4.1.5cu.798_B20221228 was discovered to contain a hardcoded password for telnet in /web_cste/cgi-bin/product.ini, which allows attackers to log in as root.
A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device.
NUUO v03.11.00 was discovered to contain access control issue.
The Relish (Verve Connect) VH510 device with firmware before 1.0.1.6L0516 contains undocumented default admin credentials for the web management interface. A remote attacker could exploit this vulnerability to login and execute commands on the device, as well as upgrade the firmware image to a malicious version.
man-group/dtale version 3.10.0 is vulnerable to an authentication bypass and remote code execution (RCE) due to improper input validation. The vulnerability arises from a hardcoded `SECRET_KEY` in the flask configuration, allowing attackers to forge a session cookie if authentication is enabled. Additionally, the application fails to properly restrict custom filter queries, enabling attackers to execute arbitrary code on the server by bypassing the restriction on the `/update-settings` endpoint, even when `enable_custom_filters` is not enabled. This vulnerability allows attackers to bypass authentication mechanisms and execute remote code on the server.
REINER timeCard 6.05.07 installs a Microsoft SQL Server with an sa password that is hardcoded in the TCServer.jar file.
A Use of Hard-Coded Cryptographic Key issue was discovered in Hyundai Motor America Blue Link 3.9.5 and 3.9.4. The application uses a hard-coded decryption password to protect sensitive user information.
iball Baton 150M iB-WRA150N v1 00000001 1.2.6 build 110401 Rel.47776n devices are prone to an authentication bypass vulnerability that allows remote attackers to view and modify administrative router settings by reading the HTML source code of the password.cgi file.
Hard-coded credentials are used by the CyberPower PowerPanel platform to authenticate to the database, other services, and the cloud. This could result in an attacker gaining access to services with the privileges of a Powerpanel business application.
An issue was discovered on Geeni GNC-CW013 doorbell 1.8.1 devices. A vulnerability exists in the Telnet service that allows a remote attacker to take full control of the device with a high-privileged account. The vulnerability exists because a system account has a default and static password.
Moxa EDR-G903 series routers with firmware before 2.11 have a hardcoded account, which allows remote attackers to obtain unspecified device access via unknown vectors.
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default debug124 password for the debug account.
An issue was discovered on CDATA 72408A, 9008A, 9016A, 92408A, 92416A, 9288, 97016, 97024P, 97028P, 97042P, 97084P, 97168P, FD1002S, FD1104, FD1104B, FD1104S, FD1104SN, FD1108S, FD1204S-R2, FD1204SN, FD1204SN-R2, FD1208S-R2, FD1216S-R1, FD1608GS, FD1608SN, FD1616GS, FD1616SN, and FD8000 devices. There is a default blank password for the guest account.