A command injection vulnerability exists in EdgeSwitch firmware <v1.9.0 that allowed an authenticated read-only user to execute arbitrary shell commands over the HTTP interface, allowing them to escalate privileges.
We have recently released new version of UniFi Protect firmware v1.13.3 and v1.14.10 for Unifi Cloud Key Gen2 Plus and UniFi Dream Machine Pro/UNVR respectively that fixes vulnerabilities found on Protect firmware v1.13.2, v1.14.9 and prior according to the description below:View only users can run certain custom commands which allows them to assign themselves unauthorized roles and escalate their privileges.
In Ubiquiti Networks EdgeSwitch X v1.1.0 and prior, a privileged user can execute arbitrary shell commands over the SSH CLI interface. This allows to execute shell commands under the root user.
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been rated as critical. Affected by this issue is some unknown functionality of the component Web Management Interface. The manipulation of the argument suffix-rate-up leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-227654 is the identifier assigned to this vulnerability.
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. This affects an unknown part of the component Web Management Interface. The manipulation of the argument ecn-up leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227649 was assigned to this vulnerability.
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Web Management Interface. The manipulation of the argument name leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227653 was assigned to this vulnerability.
A vulnerability was found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6. It has been classified as critical. Affected is an unknown function of the component Web Management Interface. The manipulation of the argument dpi leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-227652.
A vulnerability has been found in Ubiquiti EdgeRouter X up to 2.0.9-hotfix.6 and classified as critical. This vulnerability affects unknown code of the component Web Management Interface. The manipulation of the argument ecn-down leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-227650 is the identifier assigned to this vulnerability.
A vulnerability found in UniFi Talk application V1.12.3 and earlier permits a malicious actor who has already gained access to a network to subsequently control Talk device(s) assigned to said network if they are not yet adopted. This vulnerability is fixed in UniFi Talk application V1.12.5 and later.
Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system.
A remote code execution vulnerability in EdgeRouters (Version 2.0.9-hotfix.4 and earlier) allows a malicious actor with an operator account to run arbitrary administrator commands.This vulnerability is fixed in Version 2.0.9-hotfix.5 and later.
Ubiquiti EdgeOS 1.9.1 on EdgeRouter Lite devices allows remote attackers to execute arbitrary code with admin credentials, because /opt/vyatta/share/vyatta-cfg/templates/system/static-host-mapping/host-name/node.def does not sanitize the 'alias' or 'ips' parameter for shell metacharacters.
We have recently released new version of AirMax AirOS firmware v6.3.0 for TI, XW and XM boards that fixes vulnerabilities found on AirMax AirOS v6.2.0 and prior TI, XW and XM boards, according to the description below:There are certain end-points containing functionalities that are vulnerable to command injection. It is possible to craft an input string that passes the filter check but still contains commands, resulting in remote code execution.Mitigation:Update to the latest AirMax AirOS firmware version available at the AirMax download page.
A vulnerability has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6 and classified as critical. Affected by this vulnerability is an unknown functionality of the component OSPF Handler. The manipulation of the argument area leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The associated identifier of this vulnerability is VDB-223303. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
A vulnerability, which was classified as critical, has been found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. This issue affects some unknown processing of the component NAT Configuration Handler. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The identifier VDB-223301 was assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
A Command Injection vulnerability found in a Self-Hosted UniFi Network Servers (Linux) with UniFi Network Application (Version 8.3.32 and earlier) allows a malicious actor with unifi user shell access to escalate privileges to root on the host device.
On certain Ubiquiti devices, Command Injection exists via a GET request to stainfo.cgi (aka Show AP info) because the ifname variable is not sanitized, as demonstrated by shell metacharacters. The fixed version is v4.0.1 for 802.11 ISP products, v5.3.5 for AirMax ISP products, and v5.4.5 for AirSync firmware. For example, Nanostation5 (Air OS) is affected.
Command Injection in EdgeMAX EdgeSwitch prior to 1.8.2 allow an Admin user to execute commands as root.
A privilege escalation exists in UniFi Video Controller =<3.10.6 that would allow an attacker on the local machine to run arbitrary commands.
A command injection vulnerability in the DHCP Client function of all UniFi Access Points and Switches, excluding the Switch Flex Mini, could allow a Remote Code Execution (RCE). Affected Products: All UniFi Access Points (Version 6.5.53 and earlier) All UniFi Switches (Version 6.5.32 and earlier) -USW Flex Mini excluded. Mitigation: Update UniFi Access Points to Version 6.5.62 or later. Update UniFi Switches to Version 6.5.59 or later.
A backup file vulnerability found in UniFi applications (Version 7.3.83 and earlier) running on Linux operating systems allows application administrators to execute malicious commands on the host device being restored.
A vulnerability, which was classified as critical, was found in Ubiquiti EdgeRouter X 2.0.9-hotfix.6. Affected is an unknown function of the component Static Routing Configuration Handler. The manipulation of the argument next-hop-interface leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. VDB-223302 is the identifier assigned to this vulnerability. NOTE: The vendor position is that post-authentication issues are not accepted as vulnerabilities.
A malicious actor in Wi-Fi range of the affected product could leverage a vulnerability in the airMAX Wireless Protocol to achieve a remote code execution (RCE) within the affected product. Affected Products: airMAX AC (Version 8.7.20 and earlier) airMAX M (Version 6.3.22 and earlier) airFiber AF60-XG (Version 1.2.2 and earlier) airFiber AF60 (Version 2.6.7 and earlier) Mitigation: Update your airMAX AC to Version 8.7.21 or later. Update your airMAX M to Version 6.3.24 or later. Update your airFiber AF60-XG to Version 1.2.3 or later. Update your airFiber AF60 to Version 2.6.8 or later.
A malicious actor in Wi-Fi range of the affected product could leverage a vulnerability in the airMAX Wireless Protocol to achieve a remote code execution (RCE) within the affected product. Affected Products: UBB-XG (Version 1.2.2 and earlier) UDB-Pro/UDB-Pro-Sector (Version 1.4.1 and earlier) UBB (Version 3.1.5 and earlier) Mitigation: Update your UBB-XG to Version 1.2.3 or later. Update your UDB-Pro/UDB-Pro-Sector to Version 1.4.2 or later. Update your UBB to Version 3.1.7 or later.
A vulnerability classified as critical was found in Overtek OT-E801G OTE801G65.1.1.0. This vulnerability affects unknown code of the file /diag_ping.cmd?action=test&interface=ppp0.1&ipaddr=8.8.8.8%26%26cat%20/etc/passwd&ipversion=4&sessionKey=test. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in TOTOLINK N150RT 3.4.0-B20190525. It has been rated as critical. This issue affects some unknown processing of the file /boafrm/formWsc. The manipulation of the argument localPin leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0.1). The affected application do not properly validate input parameters in its REST API, resulting in improper handling of unexpected arguments. This could allow an authenticated attacker to execute arbitrary code with limited privileges.
IBM Resilient OnPrem 38.2 could allow a privileged user to inject malicious commands through Python3 scripting. IBM X-Force ID: 185503.
HCL BigFix RunBookAI is affected by a Unvalidated Command Input / Potential Command Smuggling vulnerability. A flaw in a component's input handling was identified that could permit unauthorized command execution.
A vulnerability was found in JFinalCMS 1.0. It has been rated as critical. Affected by this issue is the function update of the file \src\main\java\com\cms\controller\admin\TemplateController.java of the component Template Handler. The manipulation of the argument content leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability, which was classified as critical, has been found in TOTOLINK X18 9.1.0cu.2024_B20220329. Affected by this issue is some unknown functionality of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument enable leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been classified as critical. Affected is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in TRENDnet TEW-815DAP 1.0.2.0. It has been classified as critical. This affects the function do_setNTP of the component POST Request Handler. The manipulation of the argument NtpDstStart/NtpDstEnd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252123. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
An attacker with access to a Management Console user account with the editor role could escalate privileges through a command injection vulnerability in the Management Console. This vulnerability affected all versions of GitHub Enterprise Server and was fixed in versions 3.11.3, 3.10.5, 3.9.8, and 3.8.13 This vulnerability was reported via the GitHub Bug Bounty program.
A vulnerability was found in Totolink LR1200GB 9.1.0u.6619_B20230130. It has been rated as critical. This issue affects the function UploadFirmwareFile of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument FileName leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-249857 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability classified as critical was found in Totolink X2000R 1.0.0-B20221212.1452. Affected by this vulnerability is the function formMapDelDevice of the file /boafrm/formMapDelDevice. The manipulation of the argument macstr leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A condition exists in FlashArray and FlashBlade Purity whereby a malicious user could execute arbitrary commands remotely through a specifically crafted SNMP configuration.
A command injection vulnerability exists in the IOCTL that manages OTA updates. A specially crafted command can lead to command execution as the root user. An attacker can make authenticated requests to trigger this vulnerability.
A vulnerability classified as critical was found in TOTOLINK A6000R 1.0.1-B20201211.2000. Affected by this vulnerability is the function apcli_cancel_wps of the file /usr/lib/lua/luci/controller/mtkwifi.lua. The manipulation leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Bugzilla before 4.0.16, 4.1.x and 4.2.x before 4.2.12, 4.3.x and 4.4.x before 4.4.7, and 5.x before 5.0rc1 allows remote authenticated users to execute arbitrary commands by leveraging the editcomponents privilege and triggering crafted input to a two-argument Perl open call, as demonstrated by shell metacharacters in a product name.
A vulnerability classified as critical has been found in SevOne Network Management System up to 5.7.2.22. This affects the file traceroute.php of the Traceroute Handler. The manipulation leads to privilege escalation with a command injection. It is possible to initiate the attack remotely.
Improper Neutralization of Special Elements used in a Command vulnerability allows OS Command Injection.This issue affects Pandora FMS from 700 to 777.6
A vulnerability classified as critical was found in TOTOLINK EX1800T 9.1.0cu.2112_B20220316. This vulnerability affects the function setRebootScheCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument mode/week/minute/recHour leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was found in WeiYe-Jing datax-web 2.1.1. It has been classified as critical. This affects an unknown part of the file /api/job/add/. The manipulation of the argument glueSource leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
GoCD is a continuous delivery server. In GoCD versions prior to 22.1.0, it is possible for existing authenticated users who have permissions to edit or create pipeline materials or pipeline configuration repositories to get remote code execution capability on the GoCD server via configuring a malicious branch name which abuses Mercurial hooks/aliases to exploit a command injection weakness. An attacker would require access to an account with existing GoCD administration permissions to either create/edit (`hg`-based) configuration repositories; create/edit pipelines and their (`hg`-based) materials; or, where "pipelines-as-code" configuration repositories are used, to commit malicious configuration to such an external repository which will be automatically parsed into a pipeline configuration and (`hg`) material definition by the GoCD server. This issue is fixed in GoCD 22.1.0. As a workaround, users who do not use/rely upon Mercurial materials can uninstall/remove the `hg`/Mercurial binary from the underlying GoCD Server operating system or Docker image.
Realtek rtl819x-SDK before v3.6.1 allows command injection over the web interface.
A vulnerability was found in didi Super-Jacoco 1.0. It has been declared as critical. This vulnerability affects unknown code of the file /cov/triggerEnvCov. The manipulation of the argument uuid leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
A vulnerability has been found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this vulnerability is the function formWriteFacMac of the file /goform/WriteFacMac of the component API Endpoint. The manipulation of the argument mac leads to command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
The [`tj-actions/verify-changed-files`](https://github.com/tj-actions/verify-changed-files) action allows for command injection in changed filenames, allowing an attacker to execute arbitrary code and potentially leak secrets. The [`verify-changed-files`](https://github.com/tj-actions/verify-changed-files) workflow returns the list of files changed within a workflow execution. This could potentially allow filenames that contain special characters such as `;` which can be used by an attacker to take over the [GitHub Runner](https://docs.github.com/en/actions/using-github-hosted-runners/about-github-hosted-runners) if the output value is used in a raw fashion (thus being directly replaced before execution) inside a `run` block. By running custom commands, an attacker may be able to steal secrets such as `GITHUB_TOKEN` if triggered on other events than `pull_request`. This has been patched in versions [17](https://github.com/tj-actions/verify-changed-files/releases/tag/v17) and [17.0.0](https://github.com/tj-actions/verify-changed-files/releases/tag/v17.0.0) by enabling `safe_output` by default and returning filename paths escaping special characters for bash environments.
Totolink A830R V5.9c.4729_B20191112, Totolink A3100R V4.1.2cu.5050_B20200504, Totolink A950RG V4.1.2cu.5161_B20200903, Totolink A800R V4.1.2cu.5137_B20200730, Totolink A3000RU V5.9c.5185_B20201128, Totolink A810R V4.1.2cu.5182_B20201026 were discovered to contain a command injection vulnerability.