Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
The secret value used for access to critical UDS services of the MIB3 infotainment is hardcoded in the firmware. Vulnerability discovered on Å koda Superb III (3V3) - 2.0 TDI manufactured in 2022.
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the cloud1234 password for the a1@chopin account default credentials.
Password reset tokens are generated using an insecure source of randomness. Attackers who know the username of the Journyx installation user can bruteforce the password reset and change the administrator password.
PanIndex is a network disk directory index. In Panindex prior to version 3.1.3, a hard-coded JWT key `PanIndex` is used. An attacker can use the hard-coded JWT key to sign JWT token and perform any actions as a user with admin privileges. Version 3.1.3 has a patch for the issue. As a workaround, one may change the JWT key in the source code before compiling the project.
In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI.
An issue was discovered in Foxit Reader and PhantomPDF before 9.7.2. It allows information disclosure of a hardcoded username and password in the DocuSign plugin.
Use of hard-coded MSSQL credentials in PerkinElmer ProcessPlus on Windows allows an attacker to login remove on all prone installations.This issue affects ProcessPlus: through 1.11.6507.0.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Arkeia Network Backup Client 5.x contains hard-coded credentials that effectively serve as a back door, which allows remote attackers to access the file system and possibly execute arbitrary commands.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 3.6.1-std and 4.0.8-std devices. They contain two undocumented administrator accounts. The sftp and mofidev accounts are defined in /etc/passwd and the password is not unique across installations.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Dragonfly is an open source P2P-based file distribution and image acceleration system. It is hosted by the Cloud Native Computing Foundation (CNCF) as an Incubating Level Project. Dragonfly uses JWT to verify user. However, the secret key for JWT, "Secret Key", is hard coded, which leads to authentication bypass. An attacker can perform any action as a user with admin privileges. This issue has been addressed in release version 2.0.9. All users are advised to upgrade. There are no known workarounds for this vulnerability.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A hardcoded password was set for accounts registered using an OmniAuth provider (e.g. OAuth, LDAP, SAML) in GitLab CE/EE versions 14.7 prior to 14.7.7, 14.8 prior to 14.8.5, and 14.9 prior to 14.9.2 allowing attackers to potentially take over accounts
Akkadian Provisioning Manager Engine (PME) ships with a hard-coded credential, akkadianuser:haakkadianpassword. This issue was resolved in Akkadian OVA appliance version 3.0 (and later), Akkadian Provisioning Manager 5.0.2 (and later), and Akkadian Appliance Manager 3.3.0.314-4a349e0 (and later).
SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).
An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Denver SHC-150 Smart Wifi Camera contains a hardcoded telnet credential vulnerability that allows unauthenticated attackers to access a Linux shell. Attackers can connect to port 23 using the default credential to execute arbitrary commands on the camera's operating system.
Use of hard-coded cryptographic key vulnerability in QSAN Storage Manager allows attackers to obtain users’ credentials and related permissions. Suggest contacting with QSAN and refer to recommendations in QSAN Document.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
A use of hard-coded credentials (CWE-798) vulnerability in FortiPortal versions 5.2.5 and below, 5.3.5 and below, 6.0.4 and below, versions 5.1.x and 5.0.x may allow a remote and unauthenticated attacker to execute unauthorized commands as root by uploading and deploying malicious web application archive files using the default hard-coded Tomcat Manager username and password.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
The vulnerability of hard-coded default credentials in QSAN SANOS allows unauthenticated remote attackers to obtain administrator’s permission and execute arbitrary functions. The referred vulnerability has been solved with the updated version of QSAN SANOS v2.1.0.
Barco wePresent WiPG-1600W devices use Hard-coded Credentials (issue 2 of 2). Affected Version(s): 2.5.1.8, 2.5.0.25, 2.5.0.24, 2.4.1.19. The Barco wePresent WiPG-1600W device has a hardcoded root password hash included in the firmware image. Exploiting CVE-2020-28329, CVE-2020-28330 and CVE-2020-28331 could potentially be used in a simple and automated exploit chain to go from unauthenticated remote attacker to root shell.
A Hard Coded Admin Credentials issue in the Web-UI Admin Panel in Propius MachineSelector 6.6.0 and 6.6.1 allows remote attackers to gain access to the admin panel Propiusadmin.php, which allows taking control of the affected system.
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
Certain TP-Link devices have a Hardcoded Encryption Key. This affects NC200 2.1.9 build 200225, N210 1.0.9 build 200304, NC220 1.3.0 build 200304, NC230 1.3.0 build 200304, NC250 1.3.0 build 200304, NC260 1.5.2 build 200304, and NC450 1.5.3 build 200304.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
Advantech R-SeeNet versions 2.4.22 is installed with a hidden root-level user that is not available in the users list. This hidden user has a password that cannot be changed by users.
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which the firmware includes hard-coded credentials, which may lead to elevation of privileges or information disclosure.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
An Authorization Bypass vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to access the OBR host as a non-admin user
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
An issue was discovered in Programi Bilanc build 007 release 014 31.01.2020 and possibly below. During the installation, it sets up administrative access by default with the account admin and password 0000. After the installation, users/admins are not prompted to change this password.
An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. There is a Backdoor root account.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.
A hard-coded telnet credential in the tenda_login binary of Tenda AC15 AC1900 version 15.03.05.19 allows unauthenticated remote attackers to start a telnetd service on the device.
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
An authentication bypass issue in FormaLMS <= 2.4.4 allows an attacker to bypass the authentication mechanism and obtain a valid access to the platform.
Use of Hard-coded Credentials in EntoneWebEngine in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series and Kami7B allows remote attackers to retrieve and modify the device settings.
In the DES implementation, the affected product versions use a default key for encryption. Successful exploitation allows an attacker to obtain sensitive information and gain access to the network elements that are managed by the affected products versions. This issue affects * FOXMAN-UN product: FOXMAN-UN R16A, FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R16A, UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R16A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
The default credentials for the setup HSQL database (HSQLDB) for FileCatalyst Workflow are published in a vendor knowledgebase article. Misuse of these credentials could lead to a compromise of confidentiality, integrity, or availability of the software. The HSQLDB is only included to facilitate installation, has been deprecated, and is not intended for production use per vendor guides. However, users who have not configured FileCatalyst Workflow to use an alternative database per recommendations are vulnerable to attack from any source that can reach the HSQLDB.