In multiple functions of PasspointXmlUtils.java, there is a possible authentication misconfiguration due to a logic error in the code. This could lead to remote information disclosure with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-13Android ID: A-216854451
An improper implementation logic in Secure Folder prior to SMR Jan-2023 Release 1 allows the Secure Folder container remain unlocked under certain condition.
The S3 buckets and keys in a secure Apache Ozone Cluster must be inaccessible to anonymous access by default. The current security vulnerability allows access to keys and buckets through a curl command or an unauthenticated HTTP request. This enables unauthorized access to buckets and keys thereby exposing data to anonymous clients or users. This affected Apache Ozone prior to the 1.1.0 release.
A flaw was found in the Network Observability plugin for OpenShift console. Unless the Loki authToken configuration is set to FORWARD mode, authentication is no longer enforced, allowing any user who can connect to the OpenShift Console in an OpenShift cluster to retrieve flows without authentication.
An authentication-bypass issue was discovered on D-Link DAP-1522 devices 1.4x before 1.10b04Beta02. There exist a few pages that are directly accessible by any unauthorized user, e.g., logout.php and login.php. This occurs because of checking the value of NO_NEED_AUTH. If the value of NO_NEED_AUTH is 1, the user has direct access to the webpage without any authentication. By appending a query string NO_NEED_AUTH with the value of 1 to any protected URL, any unauthorized user can access the application directly, as demonstrated by bsc_lan.php?NO_NEED_AUTH=1.
Authentication bypass in Netcomm router models NF20MESH, NF20, and NL1902 allows an unauthenticated user to access content. In order to serve static content, the application performs a check for the existence of specific characters in the URL (.css, .png etc). If it exists, it performs a "fake login" to give the request an active session to load the file and not redirect to the login page.
An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.1.5-std devices. The wireless network password is exposed in a QR encoded picture that an unauthenticated adversary can download via the web-management interface.
Customers who had configured their polling to occur via Kerberos did not expect NTLM Traffic on their environment, but since we were querying for data via IP address this prevented us from utilizing Kerberos.
TIANJIE CPE906-3 is vulnerable to password disclosure. This is present on Software Version WEB5.0_LCD_20200513, Firmware Version MV8.003, and Hardware Version CPF906-V5.0_LCD_20200513.
The bundle management module lacks authentication and control mechanisms in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
The WMS module lacks the authentication mechanism in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
The WMS module lacks the authentication mechanism in some APIs. Successful exploitation of this vulnerability may affect data confidentiality.
An issue was discovered in Bezeq Vtech NB403-IL version BZ_2.02.07.09.13.01 and Vtech IAD604-IL versions BZ_2.02.07.09.13.01, BZ_2.02.07.09.13T, and BZ_2.02.07.09.09T, allows remote attackers to gain sensitive information via rootDesc.xml page of the UPnP service.
Vulnerability of missing authentication for critical functions in the Wi-Fi module.Successful exploitation of this vulnerability may affect service confidentiality.
A weak authentication vulnerability [CWE-1390] in FortiNAC-F version 7.2.0, FortiNAC version 9.4.2 and below, 9.2 all versions, 9.1 all versions, 8.8 all versions, 8.7 all versions in device registration page may allow an unauthenticated attacker to perform password spraying attacks with an increased chance of success.
An access control issue in Harbor v1.X.X to v2.5.3 allows attackers to access public and private image repositories without authentication. NOTE: the vendor's position is that this "is clearly described in the documentation as a feature."
An attacker with network access to the affected PLC (CJ-series and CS-series PLCs, all versions) may use a network protocol to read and write files on the PLC internal memory and memory card.
Improper authentication in OpenBlue Enterprise Manager Data Collector versions prior to 3.2.5.75 allow access to an unauthorized user under certain circumstances.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
EBM Technologies RISWEB's specific URL path is not properly controlled by permission, allowing attackers to browse specific pages and query sensitive data without login.
Missing Authentication for Critical Function vulnerability in Honeywell OneWireless allows Authentication Bypass. This issue affects OneWireless version 322.1
ReCrystallize Server 5.10.0.0 uses a authorization mechanism that relies on the value of a cookie, but it does not bind the cookie value to a session ID. Attackers can easily modify the cookie value, within a browser or by implementing client-side code outside of a browser. Attackers can bypass the authentication mechanism by modifying the cookie to contain an expected value.
A vulnerability classified as problematic has been found in SourceCodester Book Store Management System 1.0. This affects an unknown part of the file /bsms_ci/index.php/user/edit_user/. The manipulation of the argument password leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-214587.
A vulnerability in the Simple Network Management Protocol (SNMP) access controls for Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module, Cisco Firepower Management Center (FMC) Software, and Cisco Next-Generation Intrusion Prevention System (NGIPS) Software could allow an unauthenticated, remote attacker to perform an SNMP GET request using a default credential. This vulnerability is due to the presence of a default credential for SNMP version 1 (SNMPv1) and SNMP version 2 (SNMPv2). An attacker could exploit this vulnerability by sending an SNMPv1 or SNMPv2 GET request to an affected device. A successful exploit could allow the attacker to retrieve sensitive information from the device using the default credential. This attack will only be successful if SNMP is configured, and the attacker can only perform SNMP GET requests; write access using SNMP is not allowed.
Grafana 8.4.3 allows unauthenticated access via (for example) a /dashboard/snapshot/*?orgId=0 URI. NOTE: the vendor considers this a UI bug, not a vulnerability
A vulnerability has been identified in Desigo CC (All versions if access from Installed Clients to Desigo CC server is allowed from networks outside of a highly protected zone), Desigo CC (All versions if access from Installed Clients to Desigo CC server is only allowed within highly protected zones). The affected server application fails to authenticate specific client requests. Modification of the client binary could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database via the event port (default: 4998/tcp)
An authentication bypass vulnerability exists in the web component of the Motorola MR2600. An attacker can exploit this vulnerability to access protected URLs and retrieve sensitive information.
When Xiaomi router firmware is updated in 2020, there is an unauthenticated API that can reveal WIFI password vulnerability. This vulnerability is caused by the lack of access control policies on some API interfaces. Attackers can exploit this vulnerability to enter the background and execute background command injection.
Vulnerability in the Oracle Access Manager product of Oracle Fusion Middleware (component: Admin Console). The supported version that is affected is 12.2.1.4.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Access Manager. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle Access Manager accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A vulnerability classified as critical was found in Click Studios Passwordstate and Passwordstate Browser Extension Chrome. This vulnerability affects unknown code of the component API. The manipulation leads to authentication bypass by assumed-immutable data. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. The identifier of this vulnerability is VDB-216244.
Broken access controls on PDFtron data in M-Files Hubshare before 3.3.11.3 allows unauthenticated attackers to access restricted PDF files via a known URL.
Dapr Dashboard v0.1.0 through v0.10.0 is vulnerable to Incorrect Access Control that allows attackers to obtain sensitive data.
XWiki OIDC has various tools to manipulate OpenID Connect protocol in XWiki. Prior to version 1.29.1, even if a wiki has an OpenID provider configured through its xwiki.properties, it is possible to provide a third party provider its details through request parameters. One can then bypass the XWiki authentication altogether by specifying its own provider through the oidc.endpoint.* request parameters (or by using an XWiki-based OpenID provider with oidc.xwikiprovider. With the same approach, one could also provide a specific group mapping through oidc.groups.mapping that would make his user automatically part of the XWikiAdminGroup. This issue has been patched, please upgrade to 1.29.1. There is no workaround, an upgrade of the authenticator is required.
D-Link GO-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Static Default Credentials via /etc/init0.d/S80telnetd.sh.
XWiki Platform Old Core is a core package for XWiki Platform, a generic wiki platform. Prior to versions 14.2 and 13.10.4, all rights checks that would normally prevent a user from viewing a document on a wiki can be bypassed using the login action and directly specified templates. This exposes title, content and comments of any document and properties of objects, though class and property name must be known. This is also exploitable on private wikis. This has been patched in versions 14.2 and 13.10.4 by properly checking view rights before loading documents and disallowing non-default templates in the login, registration and skin action. As a workaround, it would be possible to protect all templates individually by adding code to check access rights first.
On Linksys E5350 WiFi Router with firmware version 1.0.00.037 and lower, (and potentially other vendors/devices due to code reuse), the /SysInfo.htm URI does not require a session ID. This web page calls a show_sysinfo function which retrieves WPA passwords, SSIDs, MAC Addresses, serial numbers, WPS Pins, and hardware/firmware versions, and prints this information into the web page. This web page is visible when remote management is enabled. A user who has access to the web interface of the device can extract these secrets. If the device has remote management enabled and is connected directly to the internet, this vulnerability is exploitable over the internet without interaction.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
Contract Management System v2.0 contains a weak default password which gives attackers to access database connection information.
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via T3, IIOP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).
A Missing Authentication for Critical Function vulnerability combined with a Generation of Error Message Containing Sensitive Information vulnerability in J-Web of Juniper Networks Junos OS on SRX Series and EX Series allows an unauthenticated, network-based attacker to access sensitive system information. When a user logs in, a temporary file which contains the configuration of the device (as visible to that user) is created in the /cache folder. An unauthenticated attacker can then attempt to access such a file by sending a specific request to the device trying to guess the name of such a file. Successful exploitation will reveal configuration information. This issue affects Juniper Networks Junos OS on SRX Series and EX Series: * All versions earlier than 20.4R3-S9; * 21.2 versions earlier than 21.2R3-S7; * 21.3 versions earlier than 21.3R3-S5; * 21.4 versions earlier than 21.4R3-S6; * 22.1 versions earlier than 22.1R3-S5; * 22.2 versions earlier than 22.2R3-S3; * 22.3 versions earlier than 22.3R3-S2; * 22.4 versions earlier than 22.4R3; * 23.2 versions earlier than 23.2R1-S2, 23.2R2.
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
A vulnerability was found in CodeAstro House Rental Management System 1.0. It has been rated as problematic. Affected by this issue is some unknown functionality of the file booking.php/owner.php/tenant.php. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-255392.
The memory management module has the logic bypass vulnerability. Successful exploitation of this vulnerability may affect data confidentiality.
The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage.
The MinigameCenter module has insufficient restrictions on loading URLs, which may lead to some information leakage.
A vulnerability exists in the Aruba AirWave Management Platform 8.x prior to 8.2 in the management interface of an underlying system component called RabbitMQ, which could let a malicious user obtain sensitive information. This interface listens on TCP port 15672 and 55672
antd-admin 5.5.0 is affected by an incorrect access control vulnerability. Unauthorized access to some interfaces in the foreground leads to leakage of sensitive information.
The health module has insufficient restrictions on loading URLs, which may lead to some information leakage.
Certain NETGEAR devices are affected by mishandling of repeated URL calls. This affects JNR1010v2 before 2017-01-06, WNR614 before 2017-01-06, WNR618 before 2017-01-06, JWNR2000v5 before 2017-01-06, WNR2020 before 2017-01-06, JWNR2010v5 before 2017-01-06, WNR1000v4 before 2017-01-06, WNR2020v2 before 2017-01-06, R6220 before 2017-01-06, and WNDR3700v5 before 2017-01-06.