In Artica Pandora FMS <=754 in the File Manager component, there is sensitive information exposed on the client side which attackers can access.
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.
The Portal Store module in Liferay Portal 7.0.0 through 7.3.5, and Liferay DXP 7.0 before fix pack 97, 7.1 before fix pack 21, 7.2 before fix pack 10 and 7.3 before fix pack 1 does not obfuscate the S3 store's proxy password, which allows attackers to steal the proxy password via man-in-the-middle attacks or shoulder surfing.
A man-in-the-middle attacker can inject false responses to the client's first few queries, despite the use of SSL certificate verification and encryption.
GL.iNET GL-AR750S-Ext firmware v3.215 uses an insecure protocol in its communications which allows attackers to eavesdrop via a man-in-the-middle attack.
The Passster WordPress plugin before 3.5.5.5.2 stores the password inside a cookie named "passster" using base64 encoding method which is easy to decode. This puts the password at risk in case the cookies get leaked.
The CraftCMS plugin Two-Factor Authentication in versions 3.3.1, 3.3.2 and 3.3.3 discloses the password hash of the currently authenticated user after submitting a valid TOTP.
The local Vuforia web application does not support HTTPS, and federated credentials are passed via basic authentication.
SAP BusinessObjects Platform - versions 420, 430, Information design tool transmits sensitive information as cleartext in the binaries over the network. This could allow an unauthenticated attacker with deep knowledge to gain sensitive information such as user credentials and domain names, which may have a low impact on confidentiality and no impact on the integrity and availability of the system.
A plaintext storage of a password vulnerability [CWE-256] in FortiSIEM 6.7 all versions, 6.6 all versions, 6.5 all versions, 6.4 all versions, 6.3 all versions, 6.2 all versions, 6.1 all versions, 5.4 all versions, 5.3 all versions may allow an attacker able to access user DB content to impersonate any admin user on the device GUI.
A default engineer password set on the Hozard alarm system (Alarmsysteem) v1.0 allows an attacker to bring the alarm system to a disarmed state.
An issue was discovered on V-SOL V1600D V2.03.69 and V2.03.57, V1600D4L V1.01.49, V1600D-MINI V1.01.48, V1600G1 V2.0.7 and V1.9.7, and V1600G2 V1.1.4 OLT devices. TELNET is offered by default but SSH is not always available. An attacker can intercept passwords sent in cleartext and conduct a man-in-the-middle attack on the management of the appliance.
An information disclosure vulnerability exists in the License registration functionality of Bachmann Visutec GmbH Atvise 3.5.4, 3.6 and 3.7. A plaintext HTTP request can lead to a disclosure of login credentials. An attacker can perform a man-in-the-middle attack to trigger this vulnerability.
MEDIA NAVI Inc SMACom v1.2 was discovered to contain an insecure session validation vulnerability in the session handling of the `password` authentication parameter of the wifi photo transfer module. This vulnerability allows attackers with network access privileges or on public wifi networks to read the authentication credentials and follow-up requests containing the user password via a man in the middle attack.
An issue was discovered in Softwarebuero Zauner ARC 4.2.0.4. There is storage of Passwords in a Recoverable Format.
Devolutions Server before 2021.1.18, and LTS before 2020.3.20, allows attackers to intercept private keys via a man-in-the-middle attack against the connections/partial endpoint (which accepts cleartext).
IBM Aspera Connect 4.2.5 and IBM Aspera Cargo 4.2.5 transmits authentication credentials, but it uses an insecure method that is susceptible to unauthorized interception and/or retrieval.
HCL DRYiCE Optibot Reset Station is impacted by a missing Strict Transport Security Header. This could allow an attacker to intercept or manipulate data during redirection.
The containers/image library used by the container tools Podman, Buildah, and Skopeo in Red Hat Enterprise Linux version 8 and CRI-O in OpenShift Container Platform, does not enforce TLS connections to the container registry authorization service. An attacker could use this vulnerability to launch a MiTM attack and steal login credentials or bearer tokens.