Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2023-36386

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-11 Jul, 2023 | 09:07
Updated At-21 Oct, 2024 | 21:10
Rejected At-
Credits

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the get_elements parameters.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:11 Jul, 2023 | 09:07
Updated At:21 Oct, 2024 | 21:10
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the get_elements parameters.

Affected Products
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX MX5000
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX MX5000RE
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1400
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1500
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1501
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1510
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1511
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1512
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1524
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX1536
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Vendor
Siemens AGSiemens
Product
RUGGEDCOM ROX RX5000
Default Status
unknown
Versions
Affected
  • All versions < V2.16.0
Problem Types
TypeCWE IDDescription
CWECWE-79CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Type: CWE
CWE ID: CWE-79
Description: CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf
Resource:
x_transferred
2. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:11 Jul, 2023 | 10:15
Updated At:18 Jul, 2023 | 15:45

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the get_elements parameters.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.16.1MEDIUM
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 6.1
Base severity: MEDIUM
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>ruggedcom_rox_mx5000_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_mx5000>>-
cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_mx5000re_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_mx5000re_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_mx5000re>>-
cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1400_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1400>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1500_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1500>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1501_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1501>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1510_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1510>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1511_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1511>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1512_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1512>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1524_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1524>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1536_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx1536>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx5000_firmware>>Versions before 2.16.0(exclusive)
cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>ruggedcom_rox_rx5000>>-
cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-79Primarynvd@nist.gov
CWE-79Secondaryproductcert@siemens.com
CWE ID: CWE-79
Type: Primary
Source: nvd@nist.gov
CWE ID: CWE-79
Type: Secondary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdfproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-146325.pdf
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

10687Records found

CVE-2023-36390
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.77% / 73.99%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-01 Aug, 2025 | 02:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an “invalid params element name” error on the action parameters.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1400_firmwareruggedcom_rox_mx5000reruggedcom_rox_rx1536_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_mx5000ruggedcom_rox_rx1500ruggedcom_rox_rx1536ruggedcom_rox_rx1512_firmwareruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1501ruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx1512ruggedcom_rox_rx1524ruggedcom_rox_rx1511ruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-33710
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.29% / 52.33%
||
7 Day CHG~0.00%
Published-13 Jul, 2021 | 11:03
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V4 (All versions < V4.3.9), Teamcenter Active Workspace V5.0 (All versions < V5.0.7), Teamcenter Active Workspace V5.1 (All versions < V5.1.4). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that could allow an attacker to execute malicious JavaScript code by tricking users into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V4Teamcenter Active Workspace V5.0Teamcenter Active Workspace V5.1
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-13943
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.35% / 57.67%
||
7 Day CHG~0.00%
Published-12 Dec, 2019 | 19:08
Updated-05 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. Successful exploitation does not require for an attacker to be authenticated to the web interface. This could allow the attacker to read or modify contents of the web application. At the time of advisory publication no public exploitation of this security. vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-en100_ethernet_module_with_firmware_variant_profinet_ioen100_ethernet_module_with_firmware_variant_modbus_tcpen100_ethernet_module_with_firmware_variant_iec_61850en100_ethernet_module_with_firmware_variant_dnp3_tcpen100_ethernet_module_with_firmware_variant_iec104en100_ethernet_moduleEN100 Ethernet module PROFINET IO variantEN100 Ethernet module DNP3 variantEN100 Ethernet module IEC104 variantEN100 Ethernet module Modbus TCP variantEN100 Ethernet module IEC 61850 variant
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-40631
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.67% / 71.77%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 12:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.

Action-Not Available
Vendor-Siemens AG
Product-scalance_xf206-1_firmwarescalance_xf201-3p_irtscalance_x212-2ldscalance_x201-3p_irtscalance_x204-2ldscalance_xf208scalance_x201-3p_irt_firmwarescalance_x202-2p_irt_pro_firmwarescalance_xf204irtscalance_xf204-2ba_irt_firmwarescalance_x206-1scalance_x204-2ld_ts_firmwarescalance_x204irtscalance_x201-3p_irt_prosiplus_net_scalance_x202-2p_irtscalance_x204-2fmscalance_x204-2ld_tsscalance_x208scalance_x200-4p_irtscalance_x204irt_pro_firmwarescalance_x202-2irtscalance_x202-2p_irtscalance_x204-2scalance_x224scalance_x206-1_firmwarescalance_x204-2_firmwarescalance_xf204-2scalance_xf206-1scalance_x202-2p_irt_firmwarescalance_x206-1ld_firmwarescalance_x212-2ld_firmwarescalance_x212-2scalance_xf204_firmwarescalance_x204-2ts_firmwarescalance_x208proscalance_xf204-2ba_irtscalance_x216_firmwarescalance_x204-2ld_firmwarescalance_x212-2_firmwarescalance_xf202-2p_irt_firmwarescalance_xf208_firmwarescalance_x208_firmwarescalance_xf204-2_firmwarescalance_x202-2p_irt_proscalance_x202-2irt_firmwarescalance_xf202-2p_irtscalance_x200-4p_irt_firmwarescalance_x204irt_proscalance_x216scalance_xf201-3p_irt_firmwarescalance_x204-2fm_firmwarescalance_x204-2tssiplus_net_scalance_x202-2p_irt_firmwarescalance_xf204irt_firmwarescalance_x201-3p_irt_pro_firmwarescalance_x204irt_firmwarescalance_xf204scalance_x206-1ldscalance_x208pro_firmwarescalance_x224_firmwareSCALANCE XF208SCALANCE X206-1LDSIPLUS NET SCALANCE X202-2P IRTSCALANCE X204IRTSCALANCE X202-2P IRT PROSCALANCE X204-2LDSCALANCE X201-3P IRTSCALANCE XF204-2BA IRTSCALANCE X208SCALANCE X204-2FMSCALANCE X204-2TSSCALANCE X212-2SCALANCE X204-2LD TSSCALANCE X206-1SCALANCE XF204SCALANCE XF204IRTSCALANCE X224SCALANCE XF204-2SCALANCE X208PROSCALANCE X216SCALANCE X212-2LDSCALANCE X204IRT PROSCALANCE X201-3P IRT PROSCALANCE X200-4P IRTSCALANCE X204-2SCALANCE XF206-1SCALANCE XF201-3P IRTSCALANCE X202-2P IRTSCALANCE XF202-2P IRTSCALANCE X202-2IRT
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-40772
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7||HIGH
EPSS-0.01% / 1.72%
||
7 Day CHG~0.00%
Published-14 Oct, 2025 | 09:15
Updated-10 Feb, 2026 | 09:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications are vulnerable to stored Cross-Site Scripting (XSS), allowing an attacker to inject malicious code that can be executed by other users when they visit the affected page. Successful exploitation allows an attacker to impersonate other users within the application and steal their session data. This could enable unauthorized access to accounts and potentially lead to privilege escalation.

Action-Not Available
Vendor-Siemens AG
Product-sipass_integratedSiPass integrated
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-25161
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.1||MEDIUM
EPSS-1.93% / 83.77%
||
7 Day CHG~0.00%
Published-30 Mar, 2021 | 01:44
Updated-03 Aug, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote cross-site scripting (xss) vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-scalance_w1750d_firmwareinstantscalance_w1750dAruba Instant Access Points
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-50561
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.26% / 49.85%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:50
Updated-11 Feb, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly sanitize the filenames before uploading. This could allow an authenticated remote attacker to compromise of integrity of the system.

Action-Not Available
Vendor-Siemens AG
Product-scalance_mum856-1_\(cn\)_firmwarescalance_mum853-1_\(b1\)scalance_mum856-1_\(row\)_firmwarescalance_m816-1_\(annex_b\)scalance_m874-3ruggedcom_rm1224_lte\(4g\)_euscalance_m876-3_\(rok\)_firmwarescalance_m816-1_\(annex_a\)_firmwarescalance_m876-4_\(eu\)scalance_mum856-1_\(a1\)_firmwarescalance_mum856-1_\(eu\)scalance_m874-2_firmwarescalance_m876-4_firmwarescalance_m816-1_\(annex_b\)_firmwarescalance_m876-4_\(eu\)_firmwarescalance_m874-3_\(cn\)scalance_mum856-1_\(b1\)scalance_mum856-1_\(row\)scalance_m812-1_\(annex_b\)scalance_m874-2scalance_mum853-1_\(eu\)_firmwarescalance_m812-1_\(annex_a\)scalance_m816-1_\(annex_a\)scalance_mum856-1_\(b1\)_firmwarescalance_s615_eec_firmwarescalance_m804pbscalance_m826-2scalance_mum853-1_\(a1\)_firmwarescalance_m874-3_\(cn\)_firmwarescalance_m876-4_\(nam\)scalance_mum853-1_\(a1\)scalance_m876-4scalance_s615ruggedcom_rm1224_lte\(4g\)_namscalance_m804pb_firmwarescalance_m874-3_firmwareruggedcom_rm1224_lte\(4g\)_nam_firmwarescalance_m876-3_firmwarescalance_s615_firmwarescalance_mum856-1_\(eu\)_firmwarescalance_m812-1_\(annex_b\)_firmwarescalance_m826-2_firmwarescalance_m876-3_\(rok\)scalance_m876-4_\(nam\)_firmwarescalance_mum853-1_\(b1\)_firmwarescalance_mum856-1_\(a1\)scalance_mum856-1_\(cn\)scalance_mum853-1_\(eu\)scalance_s615_eecruggedcom_rm1224_lte\(4g\)_eu_firmwarescalance_m876-3scalance_m812-1_\(annex_a\)_firmwareSCALANCE S615 LAN-RouterSCALANCE WUM766-1 (USA)SCALANCE WAM766-1 (ME)SCALANCE MUM856-1 (CN)SCALANCE MUM853-1 (A1)SCALANCE M874-3 3G-Router (CN)SCALANCE M804PBSCALANCE M876-3 (ROK)SCALANCE MUM856-1 (EU)SCALANCE M826-2 SHDSL-RouterRUGGEDCOM RM1224 LTE(4G) EUSCALANCE M816-1 ADSL-RouterSCALANCE MUM853-1 (B1)SCALANCE M874-2SCALANCE M876-3SCALANCE WUB762-1 iFeaturesSCALANCE M876-4SCALANCE M876-4 (EU)SCALANCE WAM763-1SCALANCE WUM766-1SCALANCE WAM766-1 (US)RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M874-3SCALANCE WAM763-1 (ME)SCALANCE MUM856-1 (A1)SCALANCE WAM763-1 (US)SCALANCE WAB762-1SCALANCE S615 EEC LAN-RouterSCALANCE WAM766-1 EECSCALANCE MUM853-1 (EU)SCALANCE WAM766-1 EEC (US)SCALANCE WUM763-1 (US)SCALANCE WAM766-1SCALANCE WUM763-1SCALANCE WUB762-1SCALANCE MUM856-1 (B1)SCALANCE MUM856-1 (RoW)SCALANCE WUM766-1 (ME)SCALANCE M812-1 ADSL-RouterSCALANCE WAM766-1 EEC (ME)SCALANCE M876-4 (NAM)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-46823
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-9.3||CRITICAL
EPSS-0.70% / 72.50%
||
7 Day CHG~0.00%
Published-10 Jan, 2023 | 11:39
Updated-09 Apr, 2025 | 14:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML (Mendix 8 compatible) (All versions >= V2.3.0 < V2.3.4), Mendix SAML (Mendix 9 compatible, New Track) (All versions >= V3.3.0 < V3.3.9), Mendix SAML (Mendix 9 compatible, Upgrade Track) (All versions >= V3.3.0 < V3.3.8). The affected module is vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML (Mendix 9 compatible, New Track)Mendix SAML (Mendix 9 compatible, Upgrade Track)Mendix SAML (Mendix 8 compatible)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-46350
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.67% / 71.88%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X204RNA (HSR) (All versions < V3.2.7), SCALANCE X204RNA (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (HSR) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP) (All versions < V3.2.7), SCALANCE X204RNA EEC (PRP/HSR) (All versions < V3.2.7). The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.

Action-Not Available
Vendor-Siemens AG
Product-6gk5204-0bs00-3pa36gk5204-0ba00-2mb2_firmware6gk5204-0ba00-2kb2_firmware6gk5204-0ba00-2mb26gk5204-0ba00-2kb26gk5204-0bs00-3la3_firmware6gk5204-0bs00-2na3_firmware6gk5204-0bs00-3pa3_firmware6gk5204-0bs00-2na36gk5204-0bs00-3la3SCALANCE X204RNA (HSR)SCALANCE X204RNA EEC (PRP/HSR)SCALANCE X204RNA EEC (PRP)SCALANCE X204RNA EEC (HSR)SCALANCE X204RNA (PRP)
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-44575
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.67% / 71.77%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-22 Apr, 2025 | 04:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in PLM Help Server V4.2 (All versions). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-plm_help_serverPLM Help Server V4.2
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2026-33862
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.5||HIGH
EPSS-0.03% / 9.94%
||
7 Day CHG~0.00%
Published-12 May, 2026 | 08:21
Updated-18 May, 2026 | 17:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter V2312 (All versions < V2312.0014), Teamcenter V2406 (All versions < V2406.0012), Teamcenter V2412 (All versions < V2412.0009), Teamcenter V2506 (All versions < V2506.0005), Teamcenter V2512 (All versions). The affected application does not properly encode or filter user-supplied data. This could allow an attacker to inject malicious code that can be executed by other users when they visit the affected page.

Action-Not Available
Vendor-Siemens AG
Product-teamcenterTeamcenter V2406Teamcenter V2512Teamcenter V2312Teamcenter V2412Teamcenter V2506
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2024-45385
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-2.1||LOW
EPSS-0.61% / 70.36%
||
7 Day CHG+0.16%
Published-14 Jan, 2025 | 10:30
Updated-03 Oct, 2025 | 13:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Industrial Edge Management OS (IEM-OS) (All versions). Affected components are vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-industrial_edge_managementIndustrial Edge Management OS (IEM-OS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-10041
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 55.15%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). A stored Cross-Site-Scripting (XSS) vulnerability is present in different locations of the web application. An attacker might be able to take over a session of a legitimate user.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-37896
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-10
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.1||MEDIUM
EPSS-0.21% / 42.71%
||
7 Day CHG~0.00%
Published-07 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 10:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability in the Aruba InstantOS and ArubaOS 10 web management interface could allow a remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the interface. A successful exploit could allow an attacker to execute arbitrary script code in a victim’s browser in the context of the affected interface of Aruba InstantOS 6.4.x: 6.4.4.8-4.2.4.20 and below; Aruba InstantOS 6.5.x: 6.5.4.23 and below; Aruba InstantOS 8.6.x: 8.6.0.18 and below; Aruba InstantOS 8.7.x: 8.7.1.9 and below; Aruba InstantOS 8.10.x: 8.10.0.1 and below; ArubaOS 10.3.x: 10.3.1.0 and below; Aruba has released upgrades for Aruba InstantOS that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-arubaosscalance_w1750d_firmwareinstantscalance_w1750dAruba Access Points: 100 Series; 103 Series; 110 Series; 120 Series; 130 Series; 200 Series; 207 Series; 210 Series; 220 Series; 260 Series; 300 Series; 303 Series; 310 Series; 318 Series Hardened Access Points; 320 Series; 330 Series; 340 Series; 370 Series; 500 Series; 510 Series; 530 Series; 550 Series; 630 Series; 650 Series;
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2017-11175
Matching Score-10
Assigner-MITRE Corporation
ShareView Details
Matching Score-10
Assigner-MITRE Corporation
CVSS Score-6.1||MEDIUM
EPSS-0.21% / 44.13%
||
7 Day CHG~0.00%
Published-05 Jul, 2018 | 18:00
Updated-05 Aug, 2024 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In J2 Innovations FIN Stack 4.0, the authentication webform is vulnerable to reflected XSS via the query string to /login.

Action-Not Available
Vendor-n/aSiemens AG
Product-fin_stackn/a
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2026-22610
Matching Score-10
Assigner-GitHub, Inc.
ShareView Details
Matching Score-10
Assigner-GitHub, Inc.
CVSS Score-8.5||HIGH
EPSS-0.01% / 1.12%
||
7 Day CHG-0.01%
Published-10 Jan, 2026 | 03:35
Updated-02 Jun, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Angular has XSS Vulnerability via Unsanitized SVG Script Attributes

Angular is a development platform for building mobile and desktop web applications using TypeScript/JavaScript and other languages. Prior to versions 19.2.18, 20.3.16, 21.0.7, and 21.1.0-rc.0, a cross-site scripting (XSS) vulnerability has been identified in the Angular Template Compiler. The vulnerability exists because Angular’s internal sanitization schema fails to recognize the href and xlink:href attributes of SVG <script> elements as a Resource URL context. This issue has been patched in versions 19.2.18, 20.3.16, 21.0.7, and 21.1.0-rc.0.

Action-Not Available
Vendor-angularangularSiemens AG
Product-angularangularSIDIS PrimeRUGGEDCOM RST2428P
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-32286
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.24% / 47.51%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-03 Aug, 2024 | 07:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Mendix SAML Module (Mendix 7 compatible) (All versions < V1.16.6), Mendix SAML Module (Mendix 8 compatible) (All versions < V2.2.2), Mendix SAML Module (Mendix 9 compatible) (All versions < V3.2.3). In certain configurations SAML module is vulnerable to Cross Site Scripting (XSS) attacks due to insufficient error message sanitation. This could allow an attacker to execute malicious code by tricking users into accessing a malicious link.

Action-Not Available
Vendor-mendixSiemens AG
Product-samlMendix SAML Module (Mendix 8 compatible)Mendix SAML Module (Mendix 7 compatible)Mendix SAML Module (Mendix 9 compatible)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-32145
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.53% / 67.44%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:21
Updated-03 Aug, 2024 | 07:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter Active Workspace V5.2 (All versions < V5.2.9), Teamcenter Active Workspace V6.0 (All versions < V6.0.3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious code by tricking users into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_active_workspaceTeamcenter Active Workspace V6.0Teamcenter Active Workspace V5.2
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-29034
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-7.05% / 91.68%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:21
Updated-03 Aug, 2024 | 06:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code. This could allow attackers to perform reflected cross-site scripting (XSS) attacks.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Serversinema_remote_connect_server
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-29882
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.67% / 71.85%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not handle uploaded files correctly. An unauthenticated attacker could take advantage of this situation to store an XSS attack, which could - when a legitimate user accesses the error logs - perform arbitrary actions in the name of the user.

Action-Not Available
Vendor-Siemens AG
Product-7kg8551-0aa12-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa31-2aa07kg8500-0aa30-2aa07kg8551-0aa32-2aa07kg8551-0aa01-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa32-0aa07kg8551-0aa02-0aa07kg8501-0aa31-0aa07kg8501-0aa12-0aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8551-0aa12-0aa07kg8501-0aa02-0aa0_firmware7kg8551-0aa31-2aa0_firmware7kg8551-0aa32-0aa07kg8551-0aa02-2aa0_firmware7kg8501-0aa11-0aa07kg8551-0aa01-2aa07kg8500-0aa00-2aa07kg8551-0aa31-0aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa07kg8501-0aa11-0aa0_firmware7kg8500-0aa10-0aa07kg8550-0aa00-0aa07kg8500-0aa00-2aa0_firmware7kg8501-0aa32-2aa07kg8500-0aa00-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8550-0aa00-2aa0_firmware7kg8501-0aa12-2aa07kg8551-0aa11-0aa07kg8501-0aa12-2aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa11-2aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa31-2aa07kg8551-0aa31-0aa07kg8500-0aa10-0aa0_firmware7kg8551-0aa12-2aa07kg8551-0aa11-2aa07kg8501-0aa11-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa00-0aa07kg8551-0aa01-2aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-2aa07kg8550-0aa30-0aa0_firmware7kg8500-0aa30-2aa0_firmware7kg8551-0aa01-0aa07kg8550-0aa10-0aa07kg8500-0aa10-2aa07kg8501-0aa12-0aa07kg8550-0aa00-0aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8501-0aa02-2aa07kg8551-0aa11-0aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8551-0aa02-2aa07kg8551-0aa32-0aa0_firmware7kg8501-0aa01-2aa07kg8501-0aa02-2aa0_firmware7kg8501-0aa32-0aa0_firmware7kg8501-0aa31-0aa0_firmware7kg8501-0aa01-0aa07kg8550-0aa10-2aa0_firmwareSICAM T
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-29876
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.65% / 71.40%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-09 Dec, 2025 | 16:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly handle the input of a GET request parameter. The provided argument is directly reflected in the web server response. This could allow an unauthenticated attacker to perform reflected XSS attacks.

Action-Not Available
Vendor-Siemens AG
Product-7kg8551-0aa12-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa31-2aa07kg8500-0aa30-2aa07kg8551-0aa32-2aa07kg8551-0aa01-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa32-0aa07kg8551-0aa02-0aa07kg8501-0aa31-0aa07kg8501-0aa12-0aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8551-0aa12-0aa07kg8501-0aa02-0aa0_firmware7kg8551-0aa31-2aa0_firmware7kg8551-0aa32-0aa07kg8551-0aa02-2aa0_firmware7kg8501-0aa11-0aa07kg8551-0aa01-2aa07kg8500-0aa00-2aa07kg8551-0aa31-0aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa07kg8501-0aa11-0aa0_firmware7kg8500-0aa10-0aa07kg8550-0aa00-0aa07kg8500-0aa00-2aa0_firmware7kg8501-0aa32-2aa07kg8500-0aa00-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8550-0aa00-2aa0_firmware7kg8501-0aa12-2aa07kg8551-0aa11-0aa07kg8501-0aa12-2aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa11-2aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa31-2aa07kg8551-0aa31-0aa07kg8500-0aa10-0aa0_firmware7kg8551-0aa12-2aa07kg8551-0aa11-2aa07kg8501-0aa11-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa00-0aa07kg8551-0aa01-2aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-2aa07kg8550-0aa30-0aa0_firmware7kg8500-0aa30-2aa0_firmware7kg8551-0aa01-0aa07kg8550-0aa10-0aa07kg8500-0aa10-2aa07kg8501-0aa12-0aa07kg8550-0aa00-0aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8501-0aa02-2aa07kg8551-0aa11-0aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8551-0aa02-2aa07kg8551-0aa32-0aa0_firmware7kg8501-0aa01-2aa07kg8501-0aa02-2aa0_firmware7kg8501-0aa32-0aa0_firmware7kg8501-0aa31-0aa0_firmware7kg8501-0aa01-0aa07kg8550-0aa10-2aa0_firmwareSICAM T
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-25756
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.30% / 53.54%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. This can be used by an attacker to trigger a malicious request on the affected device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x308-2lh\+scalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecSCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2022-23312
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 55.15%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-03 Aug, 2024 | 03:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP9 Security Patch 1). The integrated web application "Online Help" in affected product contains a Cross-Site Scripting (XSS) vulnerability that could be exploited if unsuspecting users are tricked into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_4Spectrum Power 4
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7579
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 59.31%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Spectrum Power™ 5 (All versions < v5.50 HF02). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. If deployed according to recommended system configuration, Siemens consideres the environmental vector as CR:L/IR:M/AR:H/MAV:A (4.1).

Action-Not Available
Vendor-Siemens AG
Product-spectrum_power_5Spectrum Power™ 5
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7575
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 59.31%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 19:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.

Action-Not Available
Vendor-Siemens AG
Product-climatix_pol908climatix_pol908_firmwareclimatix_pol909_firmwareclimatix_pol909Climatix POL909 (AWM module)Climatix POL908 (BACnet/IP module)
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-7574
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.37% / 59.31%
||
7 Day CHG~0.00%
Published-14 Apr, 2020 | 19:50
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the "Server Config" web interface of the affected devices that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web session.

Action-Not Available
Vendor-Siemens AG
Product-climatix_pol908climatix_pol908_firmwareclimatix_pol909_firmwareclimatix_pol909Climatix POL909 (AWM module)Climatix POL908 (BACnet/IP module)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-15788
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.36% / 58.48%
||
7 Day CHG~0.00%
Published-09 Sep, 2020 | 18:11
Updated-04 Aug, 2024 | 13:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user’s client. Various actions could be triggered by running malicious JavaScript code.

Action-Not Available
Vendor-Siemens AG
Product-polarion_subversion_webclientPolarion Subversion Webclient
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-44478
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.49% / 66.00%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V21 R2 P2), Polarion WebClient for SVN (All versions). A cross-site scripting is present due to improper neutralization of data sent to the web page through the SVN WebClient in the affected product. An attacker could exploit this to execute arbitrary code and extract sensitive information by sending a specially crafted link to users with administrator privileges.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almpolarion_subversion_webclientPolarion WebClient for SVNPolarion ALM
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-36389
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.59% / 69.68%
||
7 Day CHG~0.00%
Published-11 Jul, 2023 | 09:07
Updated-21 Oct, 2024 | 21:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected directly in the response without sanitization while throwing an “invalid path” error.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_mx5000reruggedcom_rox_rx1511ruggedcom_rox_rx1512_firmwareruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_mx5000re_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareRUGGEDCOM ROX MX5000RERUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-41541
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 55.15%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The Group Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.

Action-Not Available
Vendor-Siemens AG
Product-climatix_pol909_firmwareclimatix_pol909Climatix POL909 (AWM module)Climatix POL909 (AWB module)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-41542
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 55.15%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 11:31
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.44), Climatix POL909 (AWM module) (All versions < V11.36). The User Management page of affected devices is vulnerable to cross-site scripting (XSS). The vulnerability allows an attacker to send malicious JavaScript code which could result in hijacking of the user's cookie/session tokens, redirecting the user to a malicious webpage and performing unintended browser action.

Action-Not Available
Vendor-Siemens AG
Product-climatix_pol909_firmwareclimatix_pol909Climatix POL909 (AWM module)Climatix POL909 (AWB module)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2020-10043
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.36% / 58.48%
||
7 Day CHG~0.00%
Published-14 Jul, 2020 | 13:18
Updated-04 Aug, 2024 | 10:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-sicam_t_firmwaresicam_mmusicam_sgu_firmwaresicam_mmu_firmwaresicam_sgusicam_tSICAM TSICAM MMUSICAM SGU
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-6585
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.34% / 56.89%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.

Action-Not Available
Vendor-Siemens AG
Product-scalance_s623scalance_s612_firmwarescalance_s627-2m_firmwarescalance_s602scalance_s627-2mscalance_s602_firmwarescalance_s612scalance_s623_firmwareSCALANCE S627-2MSCALANCE S623SCALANCE S602SCALANCE S612
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-40893
Matching Score-10
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-10
Assigner-Nozomi Networks Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.04% / 13.60%
||
7 Day CHG~0.00%
Published-18 Dec, 2025 | 13:17
Updated-09 Jun, 2026 | 09:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HTML injection in Asset List in Guardian/CMC before 25.5.0

A Stored HTML Injection vulnerability was discovered in the Asset List functionality due to improper validation of network traffic data. An unauthenticated attacker can send specially crafted network packets to inject HTML tags into asset attributes. When a victim views the affected assets in the Asset List (and similar functions), the injected HTML renders in their browser, enabling phishing and possibly open redirect attacks. Full XSS exploitation and direct information disclosure are prevented by the existing input validation and Content Security Policy configuration.

Action-Not Available
Vendor-nozominetworksNozomi NetworksSiemens AG
Product-cmcguardianGuardianCMCRUGGEDCOM APE1808
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-19293
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.43% / 62.94%
||
7 Day CHG~0.00%
Published-10 Mar, 2020 | 19:16
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains a reflected Cross-site Scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator of the CCS web interface.

Action-Not Available
Vendor-Siemens AG
Product-sinvr_3_video_serversinvr_3_central_control_serverControl Center Server (CCS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2019-19288
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.36% / 58.48%
||
7 Day CHG~0.00%
Published-14 Dec, 2020 | 21:05
Updated-05 Aug, 2024 | 02:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link.

Action-Not Available
Vendor-Siemens AG
Product-xhqXHQ
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-31366
Matching Score-10
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-10
Assigner-Fortinet, Inc.
CVSS Score-4.5||MEDIUM
EPSS-0.02% / 5.73%
||
7 Day CHG-0.00%
Published-14 Oct, 2025 | 15:22
Updated-09 Jun, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Neutralization of Input During Web Page Generation vulnerability [CWE-79] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions, FortiProxy 7.6.0 through 7.6.3, FortiProxy 7.4 all versions, FortiProxy 7.2 all versions, FortiProxy 7.0 all versions, FortiSASE 25.2.a may allow an unauthenticated attacker to perform a reflected cross site scripting (XSS) via crafted HTTP requests.

Action-Not Available
Vendor-Fortinet, Inc.Siemens AG
Product-fortiproxyfortisasefortiosFortiProxyFortiOSFortiSASERUGGEDCOM APE1808
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2021-37195
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-6.1||MEDIUM
EPSS-0.32% / 55.15%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in COMOS V10.2 (All versions only if web components are used), COMOS V10.3 (All versions < V10.3.3.3 only if web components are used), COMOS V10.4 (All versions < V10.4.1 only if web components are used). The COMOS Web component of COMOS accepts arbitrary code as attachment to tasks. This could allow an attacker to inject malicious code that is executed when loading the attachment.

Action-Not Available
Vendor-Siemens AG
Product-comosCOMOS V10.3COMOS V10.2COMOS V10.4
CWE ID-CWE-80
Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2023-46282
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.12% / 30.68%
||
7 Day CHG~0.00%
Published-12 Dec, 2023 | 11:27
Updated-14 Jan, 2025 | 10:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.

Action-Not Available
Vendor-Siemens AG
Product-sinumerik_integrate_runmyhmi_\/automotiveopcenter_qualitysimatic_pcs_neototally_integrated_automation_portalSIMATIC PCS neoTotally Integrated Automation Portal (TIA Portal) V18Opcenter Execution FoundationOpcenter QualityTotally Integrated Automation Portal (TIA Portal) V17Totally Integrated Automation Portal (TIA Portal) V16Totally Integrated Automation Portal (TIA Portal) V14Totally Integrated Automation Portal (TIA Portal) V15.1SINEC NMS
CWE ID-CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
CVE-2025-47890
Matching Score-8
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-8
Assigner-Fortinet, Inc.
CVSS Score-2.5||LOW
EPSS-0.01% / 0.86%
||
7 Day CHG-0.00%
Published-14 Oct, 2025 | 15:22
Updated-09 Jun, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An URL Redirection to Untrusted Site vulnerabilities [CWE-601] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions, FortiProxy 7.6.0 through 7.6.3, FortiProxy 7.4 all versions, FortiProxy 7.2 all versions, FortiProxy 7.0 all versions, FortiSASE 25.2.a may allow an unauthenticated attacker to perform an open redirect attack via crafted HTTP requests.

Action-Not Available
Vendor-Fortinet, Inc.Siemens AG
Product-fortiproxyfortisasefortiosFortiProxyFortiOSFortiSASERUGGEDCOM APE1808
CWE ID-CWE-601
URL Redirection to Untrusted Site ('Open Redirect')
CVE-2025-15467
Matching Score-8
Assigner-OpenSSL Software Foundation
ShareView Details
Matching Score-8
Assigner-OpenSSL Software Foundation
CVSS Score-8.8||HIGH
EPSS-2.89% / 86.62%
||
7 Day CHG~0.00%
Published-27 Jan, 2026 | 16:01
Updated-09 Jun, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Stack buffer overflow in CMS (Auth)EnvelopedData parsing

Issue summary: Parsing CMS AuthEnvelopedData or EnvelopedData message with maliciously crafted AEAD parameters can trigger a stack buffer overflow. Impact summary: A stack buffer overflow may lead to a crash, causing Denial of Service, or potentially remote code execution. When parsing CMS (Auth)EnvelopedData structures that use AEAD ciphers such as AES-GCM, the IV (Initialization Vector) encoded in the ASN.1 parameters is copied into a fixed-size stack buffer without verifying that its length fits the destination. An attacker can supply a crafted CMS message with an oversized IV, causing a stack-based out-of-bounds write before any authentication or tag verification occurs. Applications and services that parse untrusted CMS or PKCS#7 content using AEAD ciphers (e.g., S/MIME (Auth)EnvelopedData with AES-GCM) are vulnerable. Because the overflow occurs prior to authentication, no valid key material is required to trigger it. While exploitability to remote code execution depends on platform and toolchain mitigations, the stack-based write primitive represents a severe risk. The FIPS modules in 3.6, 3.5, 3.4, 3.3 and 3.0 are not affected by this issue, as the CMS implementation is outside the OpenSSL FIPS module boundary. OpenSSL 3.6, 3.5, 3.4, 3.3 and 3.0 are vulnerable to this issue. OpenSSL 1.1.1 and 1.0.2 are not affected by this issue.

Action-Not Available
Vendor-OpenSSLSiemens AG
Product-opensslOpenSSLSIMATIC MV550 HSCALANCE SC622-2CSCALANCE XC316-8SCALANCE XR326-8 EECSIMATIC MV540 SSCALANCE MUM856-1 (RoW)AI Lightweight Inference ServerSCALANCE WUM766-1SCALANCE X302-7 EEC (2x 24V, coated)SIMATIC WinCC V8.0SINAMICS G200SCALANCE MUB852-1 (B1)SCALANCE XC332SCALANCE X308-2LH+SCALANCE XR526-8SCALANCE XF202-2P IRTConnector for AzureSINEC Security MonitorSCALANCE X307-3SCALANCE M876-4 (NAM)SCALANCE WAM766-1SIMATIC IOT2050SCALANCE LPE9403SCALANCE M876-4 (EU)SCALANCE WUB762-1 iFeaturesSCALANCE XC324-4 EECSCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE X306-1LD FESCALANCE MUM853-1 (EU)SCALANCE S615 LAN-RouterSCALANCE X204-2SIMATIC WinCC Runtime Advanced V17SIMATIC MV540 HSCALANCE XC416-8SIMATIC WinCC V8.1SINEC NMSSCALANCE LPE9413SCALANCE SC626-2CSCALANCE X204-2FMSCALANCE X204RNA EEC (PRP/HSR)SCALANCE X308-2LHSIMATIC MV560 USCALANCE XR324-4M PoE (24V, ports on front)SCALANCE WAM763-1 (ME)SCALANCE X204IRT PROSCALANCE X302-7 EEC (24V)SIMATIC WinCC OA V3.21SIPLUS NET SCALANCE X308-2SITRANS ASM IQSCALANCE WUM763-1SIMOVE Fleetmanager V3.2SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE XC432SIPLANTSIMATIC PDM V9.3SCALANCE M874-3SCALANCE X320-1 FESCALANCE X320-1-2LD FESCALANCE M804PBSCALANCE X204RNA (HSR)SIPLUS NET SCALANCE X202-2P IRTSIDIS PrimeSCALANCE M816-1 ADSL-Router familySCALANCE XF206-1SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE WUB762-1SCALANCE XF204-2SCALANCE XF204-2BA IRTSCALANCE X307-2 EEC (230V, coated)SIMATIC MV560 XSCALANCE X202-2IRTSCALANCE XR324-4M EEC (2x 24V, ports on front)User Management Component (UMC)SCALANCE X201-3P IRTSCALANCE WAM766-1 EEC (US)SCALANCE X202-2P IRTSCALANCE XR324-12M TS (24V)SIMATIC eaSie Core PackageSCALANCE XR322-12SCALANCE X302-7 EEC (230V, coated)SCALANCE XR326-8Shopfloor IT SuiteSCALANCE X212-2SINUMERIK Access MyMachine /OPC UASCALANCE WAM766-1 EECSCALANCE SC642-2CSCALANCE X206-1LDSINAMICS S200SCALANCE X204-2LDSCALANCE M876-3 (ROK)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE MUB852-1 (A1)SCALANCE XR324-4M EEC (2x 24V, ports on rear)SIMATIC HMI Mobile PanelsSCALANCE X202-2P IRT PROSIMATIC MV550 SSIMOVE Fleetmanager V3.1SCALANCE X208SCALANCE X408-2SCALANCE X307-2 EEC (230V)SCALANCE SC632-2CSCALANCE XR324-12M (24V, ports on front)SCALANCE X224SCALANCE WAM766-1 (ME)RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE X308-2M TSSCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE WAM763-1SCALANCE X302-7 EEC (230V)SCALANCE X302-7 EEC (2x 230V)SCALANCE M876-3SCALANCE WAB762-1SCALANCE X308-2M PoESCALANCE XR324-4M PoE (230V, ports on rear)SIMATIC Comfort/Mobile RTSCALANCE X310SCALANCE M826-2 SHDSL-RouterSCALANCE XR302-32RUGGEDCOM RM1224 LTE(4G) EUSCALANCE XR324-12M (230V, ports on rear)SCALANCE XR324-4M PoE (230V, ports on front)SCALANCE LPE9433SCALANCE M874-2SCALANCE X308-2MSIMATIC IPC MD-57ASIMATIC WinCC V7.5SCALANCE X307-2 EEC (24V)SIMATIC HMI Comfort PanelsSCALANCE M812-1 ADSL-Router familySINEC INSSCALANCE MUM853-1 (A1)SCALANCE WUM763-1 (US)SCALANCE S615 EEC LAN-RouterSIMATIC eaSie PCS 7 Skill PackageSCALANCE X201-3P IRT PROSIMATIC IPC ORCLASIMOVE Fleetmanager V3.3SCALANCE XF201-3P IRTSCALANCE MUM853-1 (B1)SCALANCE MUM856-1 (B1)SIMATIC WinCC Unified SequenceSCALANCE MUM856-1 (A1)SCALANCE SC636-2CSCALANCE X304-2FESIMATIC WinCC OA V3.20SIMATIC WinCC OA V3.19SCALANCE X206-1SCALANCE X204RNA EEC (HSR)SCALANCE X307-2 EEC (24V, coated)SIMATIC TargetSITRANS Soft Sensor Engine IQ (SITRANS SSE IQ)SCALANCE X302-7 EEC (2x 24V)SCALANCE WAM763-1 (US)SCALANCE X308-2SCALANCE XR522-12SIMATIC MV530 SDatabusSCALANCE WUM766-1 (USA)SCALANCE WAM766-1 (US)SCALANCE XR324-4M EEC (24V, ports on rear)HiMed CockpitSINAMICS G220SIMATIC MV540 H CRANESSCALANCE X208PROSCALANCE XF204SCALANCE X302-7 EEC (24V, coated)SCALANCE X204RNA (PRP)Siemens OPC UA Modelling Editor (SiOME)SCALANCE X204-2TSSCALANCE X204RNA EEC (PRP)SIMATIC HMI Basic PanelsSCALANCE XC324-4SCALANCE XC424-4SIMOTION OACAMGENSIMATIC STEP 7 V5SCALANCE X307-2 EEC (2x 24V)SCALANCE X204-2LD TSSCALANCE M874-3 3G-Router (CN)SCALANCE X310FESCALANCE X204IRTSCALANCE XF204IRTSCALANCE XR524-8WGSCALANCE XR324-12M (24V, ports on rear)SCALANCE MUM856-1 (CN)SCALANCE WUM766-1 (ME)SIMATIC IPC BX-21ASCALANCE X307-3LDSCALANCE MUM856-1 (EU)SCALANCE SC646-2CSCALANCE X216SINAMICS S210SIMATIC MV530 HSCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR502-32SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE WAM766-1 EEC (ME)SCALANCE X307-2 EEC (2x 230V)SCALANCE M876-4SINAMICS S220SCALANCE X200-4P IRTVisual Inspection CockpitSCALANCE X308-2LDSCALANCE X307-2 EEC (2x 24V, coated)SCALANCE X212-2LDSIMATIC RTLS Locating ManagerSCALANCE XF208SCALANCE XR324-12M (230V, ports on front)
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-11745
Matching Score-8
Assigner-Mozilla Corporation
ShareView Details
Matching Score-8
Assigner-Mozilla Corporation
CVSS Score-8.8||HIGH
EPSS-0.94% / 76.66%
||
7 Day CHG~0.00%
Published-08 Jan, 2020 | 19:22
Updated-04 Aug, 2024 | 23:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

When encrypting with a block cipher, if a call to NSC_EncryptUpdate was made with data smaller than the block size, a small out of bounds write could occur. This could have caused heap corruption and a potentially exploitable crash. This vulnerability affects Thunderbird < 68.3, Firefox ESR < 68.3, and Firefox < 71.

Action-Not Available
Vendor-Debian GNU/LinuxRed Hat, Inc.Canonical Ltd.Mozilla CorporationSiemens AGopenSUSE
Product-ubuntu_linuxruggedcom_rox_rx1511thunderbirdruggedcom_rox_rx1512_firmwarefirefoxruggedcom_rox_rx1512enterprise_linux_server_ausruggedcom_rox_mx5000_firmwareleapruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx5000debian_linuxfirefox_esrruggedcom_rox_rx1501ruggedcom_rox_mx5000ruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx5000_firmwareThunderbirdFirefox ESRFirefox
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-26988
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.07% / 78.15%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11891)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-787
Out-of-bounds Write
CVE-2022-46265
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.4||MEDIUM
EPSS-0.63% / 70.79%
||
7 Day CHG~0.00%
Published-13 Dec, 2022 | 00:00
Updated-21 Apr, 2025 | 13:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Polarion ALM (All versions < V2304.0). The affected application contains a Host header injection vulnerability that could allow an attacker to spoof a Host header information and redirect users to malicious websites.

Action-Not Available
Vendor-Siemens AG
Product-polarion_almPolarion ALM
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2020-26996
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.07% / 78.15%
||
7 Day CHG~0.00%
Published-12 Jan, 2021 | 20:18
Updated-04 Aug, 2024 | 16:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of CG4 files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12027)

Action-Not Available
Vendor-Siemens AG
Product-jt2goteamcenter_visualizationJT2GoTeamcenter Visualization
CWE ID-CWE-125
Out-of-bounds Read
CVE-2022-43398
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.45% / 64.03%
||
7 Day CHG~0.00%
Published-08 Nov, 2022 | 00:00
Updated-03 Aug, 2024 | 13:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.

Action-Not Available
Vendor-Siemens AG
Product-7kg9501-0aa01-2aa1_firmware7kg9501-0aa01-2aa17kg9501-0aa31-2aa17kg9501-0aa31-2aa1_firmwarePOWER METER SICAM Q100
CWE ID-CWE-384
Session Fixation
CVE-2024-45386
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.14%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:28
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout.

Action-Not Available
Vendor-Siemens AG
Product-SIRIUS Safety ES V19 (TIA Portal)SIMOCODE ES V19SIMATIC PCS neo V4.0SIMATIC PCS neo V5.0TIA AdministratorSIMATIC PCS neo V4.1SIRIUS Soft Starter ES V19 (TIA Portal)
CWE ID-CWE-613
Insufficient Session Expiration
CVE-2026-23230
Matching Score-8
Assigner-kernel.org
ShareView Details
Matching Score-8
Assigner-kernel.org
CVSS Score-8.8||HIGH
EPSS-0.03% / 9.19%
||
7 Day CHG~0.00%
Published-18 Feb, 2026 | 14:53
Updated-02 Jun, 2026 | 14:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
smb: client: split cached_fid bitfields to avoid shared-byte RMW races

In the Linux kernel, the following vulnerability has been resolved: smb: client: split cached_fid bitfields to avoid shared-byte RMW races is_open, has_lease and on_list are stored in the same bitfield byte in struct cached_fid but are updated in different code paths that may run concurrently. Bitfield assignments generate byte read–modify–write operations (e.g. `orb $mask, addr` on x86_64), so updating one flag can restore stale values of the others. A possible interleaving is: CPU1: load old byte (has_lease=1, on_list=1) CPU2: clear both flags (store 0) CPU1: RMW store (old | IS_OPEN) -> reintroduces cleared bits To avoid this class of races, convert these flags to separate bool fields.

Action-Not Available
Vendor-Linux Kernel Organization, IncSiemens AG
Product-linux_kernelLinuxRUGGEDCOM RST2428P
CVE-2026-21933
Matching Score-8
Assigner-Oracle
ShareView Details
Matching Score-8
Assigner-Oracle
CVSS Score-6.1||MEDIUM
EPSS-0.02% / 3.77%
||
7 Day CHG~0.00%
Published-20 Jan, 2026 | 21:56
Updated-12 May, 2026 | 13:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Vulnerability in the Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition product of Oracle Java SE (component: Networking). Supported versions that are affected are Oracle Java SE: 8u471, 8u471-b50, 8u471-perf, 11.0.29, 17.0.17, 21.0.9, 25.0.1; Oracle GraalVM for JDK: 17.0.17 and 21.0.9; Oracle GraalVM Enterprise Edition: 21.3.16. Easily exploitable vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition, attacks may significantly impact additional products (scope change). Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition accessible data as well as unauthorized read access to a subset of Oracle Java SE, Oracle GraalVM for JDK, Oracle GraalVM Enterprise Edition accessible data. Note: This vulnerability can be exploited by using APIs in the specified Component, e.g., through a web service which supplies data to the APIs. This vulnerability also applies to Java deployments, typically in clients running sandboxed Java Web Start applications or sandboxed Java applets, that load and run untrusted code (e.g., code that comes from the internet) and rely on the Java sandbox for security. CVSS 3.1 Base Score 6.1 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N).

Action-Not Available
Vendor-Oracle CorporationSiemens AG
Product-graalvm_for_jdkjdkjregraalvmOracle GraalVM for JDKOracle GraalVM Enterprise EditionOracle Java SESIMATIC CN 4100
CVE-2021-31342
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.58% / 69.30%
||
7 Day CHG~0.00%
Published-08 Jun, 2021 | 19:47
Updated-03 Aug, 2024 | 22:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The ugeom2d.dll library in all versions of Solid Edge SE2020 before 2020MP14 and all versions of Solid Edge SE2021 before SE2021MP5 lack proper validation of user-supplied data when parsing DFT files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.

Action-Not Available
Vendor-n/aSiemens AG
Product-solid_edge_se2020_firmwaresolid_edge_se2021_firmwaresolid_edge_se2020solid_edge_se2021Siemens Solid Edge
CWE ID-CWE-787
Out-of-bounds Write
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 213
  • 214
  • Next
Details not found