Delta Industrial Automation COMMGR Versions 1.12 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability that exists in HandlerPage_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in HandlerPageP_KID.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.
In Delta Electronics Automation TPEditor version 1.89 or prior, parsing a malformed program file may cause heap-based buffer overflow vulnerability, which may allow remote code execution.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file.
Delta Electronics ISPSoft version 3.20 is vulnerable to a Stack-Based buffer overflow vulnerability that could allow an attacker to leverage debugging logic to execute arbitrary code when parsing CBDGL file.
Delta Electronics ISPSoft version 3.20 is vulnerable to an Out-Of-Bounds Write vulnerability that could allow an attacker to execute arbitrary code when parsing DVP file.
Delta Electronics DTN Soft version 2.0.1 and prior are vulnerable to an attacker achieving remote code execution through a deserialization of untrusted data vulnerability.
A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field
An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.
Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in ReadRegIND. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code.
Delta Industrial Automation CNCSoft ScreenEditor Versions 1.01.28 (with ScreenEditor Version 1.01.2) and prior are vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.
Softneta MedDream PACS does not perform an authentication check and performs some dangerous functionality, which could result in unauthenticated remote code execution.0
langchain_experimental (aka LangChain Experimental) in LangChain before 0.1.8 allows an attacker to bypass the CVE-2023-44467 fix and execute arbitrary code via the __import__, __subclasses__, __builtins__, __globals__, __getattribute__, __bases__, __mro__, or __base__ attribute in Python code. These are not prohibited by pal_chain/base.py.
TwsCachedXPathAPI in Convertigo through 8.3.4 does not restrict the use of commons-jxpath APIs.
An issue was discovered in MISP before 2.4.184. A client does not need to use POST to start an export generation process. This is related to app/Controller/JobsController.php and app/View/Events/export.ctp.
This vulnerability allows remote attackers to write arbitrary files on affected installations of CentOS Web Panel cwp-e17.0.9.8.923. Authentication is not required to exploit this vulnerability. The specific flaw exists within ajax_mod_security.php. When parsing the archivo parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-9722.
Dangerous method exposed which can lead to RCE in qmpass/leadshop v1.4.15 allows an attacker to control the target host by calling any function in leadshop.php via the GET method.
SAP BTP Security Services Integration Library ([Python] sap-xssec) - versions < 4.1.0, allow under certain conditions an escalation of privileges. On successful exploitation, an unauthenticated attacker can obtain arbitrary permissions within the application.
SAP BTP Security Services Integration Library ([Golang] github.com/sap/cloud-security-client-go) - versions < 0.17.0, allow under certain conditions an escalation of privileges. On successful exploitation, an unauthenticated attacker can obtain arbitrary permissions within the application.
SAP BTP Security Services Integration Library ([Java] cloud-security-services-integration-library) - versions below 2.17.0 and versions from 3.0.0 to before 3.3.0, allow under certain conditions an escalation of privileges. On successful exploitation, an unauthenticated attacker can obtain arbitrary permissions within the application.
SAP BTP Security Services Integration Library ([Node.js] @sap/xssec - versions < 3.6.0, allow under certain conditions an escalation of privileges. On successful exploitation, an unauthenticated attacker can obtain arbitrary permissions within the application.
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server (CCS) does not properly limit its capabilities to the specified purpose. In conjunction with CVE-2019-18341, an unauthenticated remote attacker with network access to the CCS server could exploit this vulnerability to read or delete arbitrary files, or access other resources on the same server.
ius_get.cgi in IpTime C200 camera allows remote code execution. A remote attacker may send a crafted parameters to the exposed vulnerable web service interface which invokes the arbitrary shell command.
EisBaer Scada - CWE-749: Exposed Dangerous Method or Function
When user authentication is not enabled the shell can execute commands with the highest privileges. Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message comes over TCP/IP the RTU will simply accept the message with no authentication challenge.
cashIT! - serving solutions. Devices from "PoS/ Dienstleistung, Entwicklung & Vertrieb GmbH" to 03.A06rks 2023.02.37 are affected by an unauthenticated remote code execution vulnerability. This vulnerability can be triggered by an HTTP endpoint exposed to the network.
An exposed dangerous function vulnerability exists in Ivanti Avalanche before 6.3.3 using inforail Service allows Privilege Escalation via Enterprise Server Service.
An improper access control vulnerability has been reported to affect certain legacy versions of HBS 3. If exploited, this vulnerability allows attackers to compromise the security of the operating system.QNAP have already fixed this vulnerability in the following versions of HBS 3: QTS 4.3.6: HBS 3 v3.0.210507 and later QTS 4.3.4: HBS 3 v3.0.210506 and later QTS 4.3.3: HBS 3 v3.0.210506 and later
Improper access control in Citrix XenMobile Server 10.12 before RP3, Citrix XenMobile Server 10.11 before RP6, Citrix XenMobile Server 10.10 RP6 and Citrix XenMobile Server before 10.9 RP5 allows access to privileged functionality.