The KUKA SystemSoftware V/KSS in versions prior to 8.6.5 is prone to improper access control as an unauthorized attacker can directly read and write robot configurations when access control is not available or not enabled (default).
The UI in DevSpace 4.13.0 allows web sites to execute actions on pods (on behalf of a victim) because of a lack of authentication for the WebSocket protocol. This leads to remote code execution.
authentik is an open-source Identity Provider. Prior to versions 2023.8.4 and 2023.10.2, when the default admin user has been deleted, it is potentially possible for an attacker to set the password of the default admin user without any authentication. authentik uses a blueprint to create the default admin user, which can also optionally set the default admin users' password from an environment variable. When the user is deleted, the `initial-setup` flow used to configure authentik after the first installation becomes available again. authentik 2023.8.4 and 2023.10.2 fix this issue. As a workaround, ensure the default admin user (Username `akadmin`) exists and has a password set. It is recommended to use a very strong password for this user, and store it in a secure location like a password manager. It is also possible to deactivate the user to prevent any logins as akadmin.
Vulnerability of access permissions not being strictly verified in the APPWidget module.Successful exploitation of this vulnerability may cause some apps to run without being authorized.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
In JetBrains TeamCity before 2023.05.4 authentication bypass leading to RCE on TeamCity Server was possible
SMS-based GPS commands can be executed by MiCODUS MV720 GPS tracker without authentication.
Lack of access control in Nakivo Backup & Replication Transporter version 9.4.0.r43656 allows remote users to access unencrypted backup repositories and the Nakivo Controller configuration via a network accessible transporter service. It is also possible to create or delete backup repositories.
Multiple vulnerabilities in Cisco Nexus Dashboard could allow an unauthenticated, remote attacker to execute arbitrary commands, read or upload container image files, or perform a cross-site request forgery attack. For more information about these vulnerabilities, see the Details section of this advisory.
D-Link - CWE-288:Authentication Bypass Using an Alternate Path or Channel
Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message is received over TCP/IP the RTU will simply accept the message with no authentication challenge.
Sing-box is an open source proxy system. Affected versions are subject to an authentication bypass when specially crafted requests are sent to sing-box. This affects all SOCKS5 inbounds with user authentication and an attacker may be able to bypass authentication. Users are advised to update to sing-box 1.4.4 or to 1.5.0-rc.4. Users unable to update should not expose the SOCKS5 inbound to insecure environments.
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation G-50 Version 3.37 and prior, G-50-W Version 3.37 and prior, G-50A Version 3.37 and prior, GB-50 Version 3.37 and prior, GB-50A Version 3.37 and prior, GB-24A Version 9.12 and prior, G-150AD Version 3.21 and prior, AG-150A-A Version 3.21 and prior, AG-150A-J Version 3.21 and prior, GB-50AD Version 3.21 and prior, GB-50ADA-A Version 3.21 and prior, GB-50ADA-J Version 3.21 and prior, EB-50GU-A Version 7.11 and prior, EB-50GU-J Version 7.11 and prior, AE-200J Version 8.01 and prior, AE-200A Version 8.01 and prior, AE-200E Version 8.01 and prior, AE-50J Version 8.01 and prior, AE-50A Version 8.01 and prior, AE-50E Version 8.01 and prior, EW-50J Version 8.01 and prior, EW-50A Version 8.01 and prior, EW-50E Version 8.01 and prior, TE-200A Version 8.01 and prior, TE-50A Version 8.01 and prior, TW-50A Version 8.01 and prior, and CMS-RMD-J Version 1.40 and prior allows a remote unauthenticated attacker to bypass authentication and then control the air conditioning systems illegally, or disclose information in them by exploiting this vulnerability. In addition, the attacker may tamper with firmware for them using the disclosed information.
Chunghwa Telecom NOKIA G-040W-Q has a vulnerability of authentication bypass, which allows an unauthenticated remote attacker to bypass the authentication mechanism to log in to the device by an alternative URL. This makes it possible for unauthenticated remote attackers to log in as any existing users, such as an administrator, to perform arbitrary system operations or disrupt service.
Authentication bypass when an OAuth2 Client is using client_secret_jwt as its authentication method on affected 11.3 versions via specially crafted requests.
The system application (com.transsion.kolun.aiservice) component does not perform an authentication check, which allows attackers to perform malicious exploitations and affect system services.
newbee-mall all versions are affected by incorrect access control to remotely gain privileges through AdminLoginInterceptor.java. The authentication logic of the system's background /admin is in code AdminLoginInterceptor, which can be bypassed.
A first-factor authentication bypass vulnerability exists in the PingFederate with PingID Radius PCV when a MSCHAP authentication request is sent via a maliciously crafted RADIUS client request.
Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication.
Vulnerability in the Oracle Scripting product of Oracle E-Business Suite (component: iSurvey Module). Supported versions that are affected are 12.2.3-12.2.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Scripting. Successful attacks of this vulnerability can result in takeover of Oracle Scripting. CVSS 3.1 Base Score 9.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
Vasion Print (formerly PrinterLogic) before Virtual Appliance Host 22.0.933 Application 20.0.2368 allows Unauthenticated Driver Package Editing V-2024-008.
A CWE-306 "Missing Authentication for Critical Function" in maxtime/handleRoute.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to affect the device confidentiality, integrity, or availability in multiple unspecified ways via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user permissions via crafted HTTP requests.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/menu/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to edit user group permissions via crafted HTTP requests.
SAP PowerDesigner - version 16.7, has improper access control which might allow an unauthenticated attacker to run arbitrary queries against the back-end database via Proxy.
Windows Mobile Device Management Elevation of Privilege Vulnerability
CasaOS is an open-source Personal Cloud system. Due to a lack of IP address verification an unauthenticated attackers can execute arbitrary commands as `root` on CasaOS instances. The problem was addressed by improving the detection of client IP addresses in `391dd7f`. This patch is part of CasaOS 0.4.4. Users should upgrade to CasaOS 0.4.4. If they can't, they should temporarily restrict access to CasaOS to untrusted users, for instance by not exposing it publicly.
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
STW (aka Sensor-Technik Wiedemann) TCG-4 Connectivity Module DeploymentPackage_v3.03r0-Impala and DeploymentPackage_v3.04r2-Jellyfish and TCG-4lite Connectivity Module DeploymentPackage_v3.04r2-Jellyfish allow an attacker to gain full remote access with root privileges without the need for authentication, giving an attacker arbitrary remote code execution over LTE / 4G network via SMS.
Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to reset user PINs via crafted HTTP requests.
VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
An issue in Planet Technologies WDRT-1800AX v1.01-CP21 allows attackers to bypass authentication and escalate privileges to root via manipulation of the LoginStatus cookie.
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/accounts/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to reset arbitrary user passwords via crafted HTTP requests.
Improper authentication vulnerability exists in KB-AHR series and KB-IRIP series. If this vulnerability is exploited, an arbitrary OS command may be executed on the product or the device settings may be altered. Affected products and versions are as follows: KB-AHR04D versions prior to 91110.1.101106.78, KB-AHR08D versions prior to 91210.1.101106.78, KB-AHR16D versions prior to 91310.1.101106.78, KB-IRIP04A versions prior to 95110.1.100290.78A, KB-IRIP08A versions prior to 95210.1.100290.78A, and KB-IRIP16A versions prior to 95310.1.100290.78A.
mage-ai is an open-source data pipeline tool for transforming and integrating data. Those who use Mage starting in version 0.8.34 and prior to 0.8.72 with user authentication enabled may be affected by a vulnerability. The terminal could be accessed by users who are not signed in or do not have editor permissions. Version 0.8.72 contains a fix for this issue.
A remote unprivileged attacker can modify and access configuration settings on the EventCam App due to the absence of API authentication. The lack of authentication in the API allows the attacker to potentially compromise the functionality of the EventCam App.
It is identified a vulnerability of insufficient authentication in the system configuration interface of Hitron Technologies CODA-5310. An unauthorized remote attacker can exploit this vulnerability to access system configuration interface, resulting in performing arbitrary system operation or disrupt service.
Multiple Version of TRUMPF TruTops products expose a service function without necessary authentication. Execution of this function may result in unauthorized access to change of data or disruption of the whole service.
On F5 BIG-IP 16.1.x versions prior to 16.1.2.2, 15.1.x versions prior to 15.1.5.1, 14.1.x versions prior to 14.1.4.6, 13.1.x versions prior to 13.1.5, and all 12.1.x and 11.6.x versions, undisclosed requests may bypass iControl REST authentication. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated
The SiteGround Security plugin for WordPress is vulnerable to authentication bypass that allows unauthenticated users to log in as administrative users due to missing identity verification on the 2FA back-up code implementation that logs users in upon success. This affects versions up to, and including, 1.2.5.
The Custom MCPs feature is designed to execute OS commands, for instance, using tools like `npx` to spin up local MCP Servers. However, Flowise's inherent authentication and authorization model is minimal and lacks role-based access controls (RBAC). Furthermore, in Flowise versions before 3.0.1 the default installation operates without authentication unless explicitly configured. This combination allows unauthenticated network attackers to execute unsandboxed OS commands.
The SiteGround Security plugin for WordPress is vulnerable to authentication bypass that allows unauthenticated users to log in as administrative users due to missing identity verification on initial 2FA set-up that allows unauthenticated and unauthorized users to configure 2FA for pending accounts. Upon successful configuration, the attacker is logged in as that user without access to a username/password pair which is the expected first form of authentication. This affects versions up to, and including, 1.2.5.
TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents.
An issue regarding missing authentication for certain utilities exists in CyberPower PowerPanel Enterprise prior to v2.8.3. An unauthenticated remote attacker can access the PDNU REST APIs, which may result in compromise of the application.
Webhood is a self-hosted URL scanner used analyzing phishing and malicious sites. Webhood's backend container images in versions 0.9.0 and earlier are subject to Missing Authentication for Critical Function vulnerability. This vulnerability allows an unauthenticated attacker to send a HTTP request to the database (Pocketbase) admin API to create an admin account. The Pocketbase admin API does not check for authentication/authorization when creating an admin account when no admin accounts have been added. In its default deployment, Webhood does not create a database admin account. Therefore, unless users have manually created an admin account in the database, an admin account will not exist in the deployment and the deployment is vulnerable. Versions starting from 0.9.1 are patched. The patch creates a randomly generated admin account if admin accounts have not already been created i.e. the vulnerability is exploitable in the deployment. As a workaround, users can disable access to URL path starting with `/api/admins` entirely. With this workaround, the vulnerability is not exploitable via network.
Improper access control in PAM vault permissions in Devolutions Server 2024.1.10.0 and earlier allows an authenticated user with access to the PAM to access unauthorized PAM entries via a specific set of permissions.
Advantech iView, versions 5.6 and prior, has an improper authentication for critical function (CWE-306) issue. Successful exploitation of this vulnerability may allow an attacker to obtain the information of the user table, including the administrator credentials in plain text. An attacker may also delete the administrator account.