A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
itsourcecode Online Hotel Management System Project In PHP v1.0.0 is vulnerable to Cross Site Scripting (XSS). Remote code execution can be achieved by entering malicious code in the date selection box.
The cross-site scripting vulnerability has been reported to affect earlier versions of Photo Station. If exploited, the vulnerability could allow remote attackers to inject malicious code. This issue affects: QNAP Systems Inc. Photo Station versions prior to 5.7.11; versions prior to 6.0.10.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
If exploited, this cross-site scripting vulnerability could allow remote attackers to inject malicious code. This issue affects: QNAP Systems Inc. Music Station versions prior to 5.1.13; versions prior to 5.2.9; versions prior to 5.3.11.
Computer Vision Annotation Tool (CVAT) is an interactive video and image annotation tool for computer vision. If a malicious CVAT user with permissions to either create a task, or edit an existing task can trick another logged-in user into visiting a maliciously-constructed URL, they can initiate any API calls on that user's behalf. This gives the attacker temporary access to all data that the victim user has access to. Upgrade to CVAT 2.19.0 or a later version to fix this issue.
HTML injection via report name. The following products are affected: Acronis Cyber Protect 15 (Linux, Windows) before build 29240
Cross Site Scripting vulnerability found in KOHGYLW Kiftd v.1.0.18 allows a remote attacker to execute arbitrary code via the <ifram> tag in the upload file page.
LayUI is a native minimalist modular Web UI component library. Versions prior to 2.9.17 have a DOM Clobbering vulnerability that can lead to Cross-site Scripting (XSS) on web pages where attacker-controlled HTML elements (e.g., `img` tags with unsanitized `name` attributes) are present. Version 2.9.17 fixes this issue.
S-CMS Government Station Building System v5.0 contains a cross-site scripting (XSS) vulnerability in the search function.
PHPFusion 9.03.110 is affected by cross-site scripting (XSS) in the preg patterns filter html tag without "//" in descript() function An authenticated user can trigger XSS by appending "//" in the end of text.
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in WPCOM WPCOM Member allows Reflected XSS.This issue affects WPCOM Member: from n/a through 1.5.4.
Lifesize Express ls ex2_4.7.10 2000 (14) devices allow XSS via the interface/interface.php brand parameter.
phpwcms v1.9 contains a cross-site scripting (XSS) vulnerability in /image_zoom.php.
A form validation endpoint in Jenkins Queue cleanup Plugin 1.3 and earlier does not properly escape a query parameter displayed in an error message, resulting in a reflected XSS vulnerability.
Cross Site Scripting (XSS) vulnerability in MetInfo 7.0.0 via the gourl parameter in login.php.
A vulnerability was found in PHPGurukul Taxi Stand Management System 1.0 and classified as problematic. Affected by this issue is some unknown functionality of the file /admin/search-autoortaxi.php. The manipulation of the argument searchdata leads to cross site scripting. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Prior to this patch being applied, Mautic's tracking was vulnerable to Cross-Site Scripting through the Page URL variable.
A cross-site scripting (XSS) vulnerability in the referer parameter of Dzzoffice 2.02 allows attackers to execute arbitrary web scripts or HTML via a crafted payload.
IceWarp 11.4.6.0 was discovered to contain a cross-site scripting (XSS) vulnerability via the color parameter.
A reflected Cross Site Scripting (XSS) in wuzhicms v4.1.0 allows remote attackers to execute arbitrary web script or HTML via the imgurl parameter.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
An issue was discovered in Arcserve Unified Data Protection (UDP) through 6.5 Update 4. There is a DDI-VRT-2018-21 Reflected Cross-site Scripting via /authenticationendpoint/domain.jsp issue.
The sanitize_string function in Zenphoto before 1.4.9 does not properly sanitize HTML tags, which allows remote attackers to perform a cross-site scripting (XSS) attack by wrapping a payload in "<<script></script>script>payload<script></script></script>", or in an image tag, with the payload as the onerror event.
ZTE MF971R product has reflective XSS vulnerability. An attacker could use the vulnerability to obtain cookie information.
jQuery v2.2.2 allows XSS via a crafted onerror attribute of an IMG element. NOTE: this vulnerability has been reported to be spam entry
Adobe Connect version 11.2.3 (and earlier) is affected by a reflected Cross-Site Scripting (XSS) vulnerability. If an attacker is able to convince a victim to visit a URL referencing a vulnerable page, malicious JavaScript content may be executed within the context of the victim's browser.
Improper neutralization of input in Nagvis before version 1.9.47 which can lead to XSS
The elementor-edit-template class in wp-admin/customize.php in the Elementor Pro plugin before 2.0.10 for WordPress has XSS.
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)
Cross Site Scripting (XSS) vulnerability in the Showtime2 Slideshow module in CMS Made Simple (CMSMS) 2.2.4.
GNUBOARD5 5.3.1.9 has XSS that allows remote attackers to inject arbitrary web script or HTML via the "board tail contents" parameter, aka the adm/board_form_update.php bo_content_tail parameter.
Minecraft MOTD Parser is a PHP library to parse minecraft server motd. The HtmlGenerator class is subject to potential cross-site scripting (XSS) attack through a parsed malformed Minecraft server MOTD. The HtmlGenerator iterates through objects of MotdItem that are contained in an object of MotdItemCollection to generate a HTML string. An attacker can make malicious inputs to the color and text properties of MotdItem to inject own HTML into a web page during web page generation. For example by sending a malicious MOTD from a Minecraft server under their control that was queried and passed to the HtmlGenerator. This XSS vulnerability exists because the values of these properties are neither filtered nor escaped. This vulnerability is fixed in 1.0.6.
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in weDevs WP ERP allows Reflected XSS.This issue affects WP ERP: from n/a through 1.13.2.
Grafana 5.3.1 has XSS via a column style on the "Dashboard > Table Panel" screen. NOTE: this issue exists because of an incomplete fix for CVE-2018-12099.
Grafana 5.3.1 has XSS via the "Dashboard > Text Panel" screen. NOTE: this issue exists because of an incomplete fix for CVE-2018-12099.
Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Booking Algorithms BA Book Everything allows Reflected XSS.This issue affects BA Book Everything: from n/a through 1.6.20.
Cross-site scripting vulnerabilities exist in the ssh_form.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a crafted URL to trigger this vulnerability.
There is an XSS vulnerability in some HikCentral Master Lite versions. If exploited, an attacker could inject scripts into certain pages by building malicious data.
Fiyo CMS 2.0.7 has XSS via the dapur\apps\app_user\edit_user.php name parameter.
Multiple vulnerabilities in the web-based management interface of Cisco Identity Services Engine (ISE) Software could allow an attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. For more information about these vulnerabilities, see the Details section of this advisory.
PHPgurukl Small CRM v.1.0 is vulnerable to Cross Site Scripting (XSS).
OP5 Monitor 8.3.1, 8.3.2, and OP5 8.3.3 are vulnerable to Cross Site Scripting (XSS).
A vulnerability has been found in 1000 Projects Sales Management System 1.0. Affected is an unknown function of the file /sales.php. The manipulation of the argument select2112 leads to cross site scripting. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Proofpoint Insider Threat Management Server (formerly ObserveIT Server) before 7.11.1 allows stored XSS.
Cross-site scripting vulnerabilities exist in the telnet_form.php script functionality of Advantech R-SeeNet v 2.4.12 (20.10.2020). If a user visits a specially crafted URL, it can lead to arbitrary JavaScript code execution in the context of the targeted user’s browser. An attacker can provide a crafted URL to trigger this vulnerability.
GNUBOARD5 before 5.3.2.0 has XSS that allows remote attackers to inject arbitrary web script or HTML via the "board group extra contents" parameter, aka the adm/boardgroup_form_update.php gr_1~10 parameter.
Filament is a collection of full-stack components for Laravel development. Versions of Filament from v3.0.0 through v3.2.114 are affected by a cross-site scripting (XSS) vulnerability. If values passed to a `ColorColumn` or `ColumnEntry` are not valid and contain a specific set of characters, applications are vulnerable to XSS attack against a user who opens a page on which a color column or entry is rendered. Filament v3.2.115 fixes this issue.
OpenRefine is a free, open source tool for working with messy data. Prior to version 3.8.3, the built-in "Something went wrong!" error page includes the exception message and exception traceback without escaping HTML tags, enabling injection into the page if an attacker can reliably produce an error with an attacker-influenced message. It appears that the only way to reach this code in OpenRefine itself is for an attacker to somehow convince a victim to import a malicious file, which may be difficult. However, out-of-tree extensions may add their own calls to `respondWithErrorPage`. Version 3.8.3 has a fix for this issue.
Cross Site Scripting (XSS) vulnerability in gnuboard5 <=v5.3.2.8 via the url parameter to bbs/login.php.