Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-39759

Summary
Assigner-talos
Assigner Org ID-b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At-14 Jan, 2025 | 14:21
Updated At-03 Nov, 2025 | 21:56
Rejected At-
Credits

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_hour_value` POST parameter.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:talos
Assigner Org ID:b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b
Published At:14 Jan, 2025 | 14:21
Updated At:03 Nov, 2025 | 21:56
Rejected At:
▼CVE Numbering Authority (CNA)

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_hour_value` POST parameter.

Affected Products
Vendor
WAVLINK Technology Ltd.Wavlink
Product
Wavlink AC3000
Versions
Affected
  • M33A8.V5030.210505
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.110.0CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Version: 3.1
Base score: 10.0
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Discovered by Lilith >_> of Cisco Talos.
Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://talosintelligence.com/vulnerability_reports/TALOS-2024-2018
N/A
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2024-2018
Resource: N/A
▼Authorized Data Publishers (ADP)
1. CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
2. CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2018
N/A
Hyperlink: https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2018
Resource: N/A
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:talos-cna@cisco.com
Published At:14 Jan, 2025 | 15:15
Updated At:03 Nov, 2025 | 22:17

Multiple OS command injection vulnerabilities exist in the login.cgi set_sys_init() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary code execution. An attacker can make an unauthenticated HTTP request to trigger these vulnerabilities.A command injection vulnerability exists within the `restart_hour_value` POST parameter.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.110.0CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Primary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 10.0
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

WAVLINK Technology Ltd.
wavlink
>>wl-wn533a8_firmware>>m33a8.v5030.210505
cpe:2.3:o:wavlink:wl-wn533a8_firmware:m33a8.v5030.210505:*:*:*:*:*:*:*
WAVLINK Technology Ltd.
wavlink
>>wl-wn533a8>>-
cpe:2.3:h:wavlink:wl-wn533a8:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondarytalos-cna@cisco.com
CWE ID: CWE-77
Type: Secondary
Source: talos-cna@cisco.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://talosintelligence.com/vulnerability_reports/TALOS-2024-2018talos-cna@cisco.com
Exploit
Third Party Advisory
https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2018af854a3a-2127-422b-91ae-364da2661108
N/A
Hyperlink: https://talosintelligence.com/vulnerability_reports/TALOS-2024-2018
Source: talos-cna@cisco.com
Resource:
Exploit
Third Party Advisory
Hyperlink: https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2018
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1146Records found

CVE-2026-2526
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.76%
||
7 Day CHG~0.00%
Published-16 Feb, 2026 | 01:02
Updated-23 Feb, 2026 | 10:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi multi_ssid command injection

A vulnerability was found in Wavlink WL-WN579A3 up to 20210219. This impacts the function multi_ssid of the file /cgi-bin/wireless.cgi. Performing a manipulation of the argument SSID2G2 results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2530
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.76%
||
7 Day CHG~0.00%
Published-16 Feb, 2026 | 02:32
Updated-23 Feb, 2026 | 10:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN579A3 wireless.cgi AddMac command injection

A weakness has been identified in Wavlink WL-WN579A3 up to 20210219. This affects the function AddMac of the file /cgi-bin/wireless.cgi. This manipulation of the argument macAddr causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn579a3_firmwarewl-wn579a3WL-WN579A3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-10193
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.70% / 72.50%
||
7 Day CHG~0.00%
Published-20 Oct, 2024 | 07:31
Updated-23 Oct, 2024 | 16:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAVLINK WN530H4/WN530HG4/WN572HG3 internet.cgi ping_ddns command injection

A vulnerability was found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028 and classified as critical. This issue affects the function ping_ddns of the file internet.cgi. The manipulation of the argument DDNS leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wn530h4wn530h4_firmwarewn530hg4_firmwarewn530hg4wn572hg3_firmwarewn572hg3WN530H4WN572HG3WN530HG4wn530h4_firmwarewn530hg4_firmwarewn572hg3_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10325
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.07% / 78.19%
||
7 Day CHG+0.13%
Published-12 Sep, 2025 | 20:02
Updated-02 Oct, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 login.cgi sub_401BA4 command injection

A vulnerability was identified in Wavlink WL-WN578W2 221110. This impacts the function sub_401340/sub_401BA4 of the file /cgi-bin/login.cgi. Such manipulation of the argument ipaddr leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-10429
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-36.73% / 97.25%
||
7 Day CHG+3.86%
Published-27 Oct, 2024 | 21:00
Updated-13 Nov, 2024 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAVLINK WN530H4/WN530HG4/WN572HG3 internet.cgi set_ipv6 command injection

A vulnerability classified as critical has been found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028. Affected is the function set_ipv6 of the file internet.cgi. The manipulation of the argument IPv6OpMode/IPv6IPAddr/IPv6WANIPAddr/IPv6GWAddr leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wn530h4wn530h4_firmwarewn530hg4_firmwarewn530hg4wn572hg3_firmwarewn572hg3WN530H4WN572HG3WN530HG4wn530h4_firmwarewn530hg4_firmwarewn572hg3_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-10428
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-1.26% / 79.90%
||
7 Day CHG~0.00%
Published-27 Oct, 2024 | 20:31
Updated-13 Nov, 2024 | 17:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
WAVLINK WN530H4/WN530HG4/WN572HG3 firewall.cgi set_ipv6 command injection

A vulnerability was found in WAVLINK WN530H4, WN530HG4 and WN572HG3 up to 20221028. It has been rated as critical. This issue affects the function set_ipv6 of the file firewall.cgi. The manipulation of the argument dhcpGateway leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wn530h4wn530h4_firmwarewn530hg4_firmwarewn530hg4wn572hg3_firmwarewn572hg3WN530H4WN572HG3WN530HG4wn572hg3_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-49833
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.9||HIGH
EPSS-4.35% / 89.22%
||
7 Day CHG~0.00%
Published-15 Jul, 2025 | 20:22
Updated-30 Jul, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GHSL-2025-045: GPT-SoVITS Command Injection vulnerability

GPT-SoVITS-WebUI is a voice conversion and text-to-speech webUI. In versions 20250228v3 and prior, there is a command injection vulnerability in the webui.py open_slice function. slice_opt_root and slice-inp-path takes user input, which is passed to the open_slice function, which concatenates the user input into a command and runs it on the server, leading to arbitrary command execution. At time of publication, no known patched versions are available.

Action-Not Available
Vendor-rvc-bossRVC-Boss
Product-gpt-sovits-webuiGPT-SoVITS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4999
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.95% / 83.89%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-5914
Matching Score-4
Assigner-Palo Alto Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Palo Alto Networks, Inc.
CVSS Score-7||HIGH
EPSS-2.42% / 85.51%
||
7 Day CHG~0.00%
Published-14 Aug, 2024 | 16:40
Updated-20 Aug, 2024 | 16:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cortex XSOAR: Command Injection in CommonScripts Pack

A command injection issue in Palo Alto Networks Cortex XSOAR CommonScripts Pack allows an unauthenticated attacker to execute arbitrary commands within the context of an integration container.

Action-Not Available
Vendor-Palo Alto Networks, Inc.
Product-cortex_xsoar_commonscriptsCortex XSOAR CommonScripts
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50526
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.19% / 41.41%
||
7 Day CHG~0.00%
Published-23 Dec, 2025 | 00:00
Updated-02 Jan, 2026 | 14:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Netgear EX8000 V1.0.0.126 was discovered to contain a command injection vulnerability via the switch_status function.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-ex8000_firmwareex8000n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-49835
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.9||HIGH
EPSS-4.35% / 89.22%
||
7 Day CHG~0.00%
Published-15 Jul, 2025 | 20:29
Updated-30 Jul, 2025 | 20:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GHSL-2025-047: GPT-SoVITS Command Injection vulnerability

GPT-SoVITS-WebUI is a voice conversion and text-to-speech webUI. In versions 20250228v3 and prior, there is a command injection vulnerability in webui.py open_asr function. asr_inp_dir (and a number of other variables) takes user input, which is passed to the open_asr function, which concatenates the user input into a command and runs it on the server, leading to arbitrary command execution. At time of publication, no known patched versions are available.

Action-Not Available
Vendor-rvc-bossRVC-Boss
Product-gpt-sovits-webuiGPT-SoVITS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50428
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.84% / 88.48%
||
7 Day CHG~0.00%
Published-27 Aug, 2025 | 00:00
Updated-09 Sep, 2025 | 18:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In RaspAP raspap-webgui 3.3.2 and earlier, a command injection vulnerability exists in the includes/hostapd.php script. The vulnerability is due to improper sanitizing of user input passed via the interface parameter.

Action-Not Available
Vendor-raspapn/a
Product-raspap-webguin/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-50722
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.35% / 80.54%
||
7 Day CHG~0.00%
Published-25 Aug, 2025 | 00:00
Updated-09 Sep, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Insecure Permissions vulnerability in sparkshop v.1.1.7 allows a remote attacker to execute arbitrary code via the Common.php component

Action-Not Available
Vendor-sparkshopn/a
Product-sparkshopn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-49836
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.9||HIGH
EPSS-5.74% / 90.68%
||
7 Day CHG~0.00%
Published-15 Jul, 2025 | 20:31
Updated-30 Jul, 2025 | 20:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GHSL-2025-048: GPT-SoVITS Command Injection vulnerability

GPT-SoVITS-WebUI is a voice conversion and text-to-speech webUI. In versions 20250228v3 and prior, there is a command injection vulnerability in webui.py change_label function. path_list takes user input, which is passed to the change_label function, which concatenates the user input into a command and runs it on the server, leading to arbitrary command execution. At time of publication, no known patched versions are available.

Action-Not Available
Vendor-rvc-bossRVC-Boss
Product-gpt-sovits-webuiGPT-SoVITS
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-32194
Matching Score-4
Assigner-Microsoft Corporation
ShareView Details
Matching Score-4
Assigner-Microsoft Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.09%
||
7 Day CHG~0.00%
Published-19 Mar, 2026 | 21:21
Updated-14 Apr, 2026 | 16:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Microsoft Bing Images Remote Code Execution Vulnerability

Improper neutralization of special elements used in a command ('command injection') in Microsoft Bing Images allows an unauthorized attacker to execute code over a network.

Action-Not Available
Vendor-Microsoft Corporation
Product-bing_imagesMicrosoft Bing Images
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45742
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-18.71% / 95.45%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK A720R v4.1.5cu.470_B20200911 was discovered to contain a command injection vulnerability in the "Main" function. This vulnerability allows attackers to execute arbitrary commands via the QUERY_STRING parameter.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a720ra720r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46231
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function urlrd_opt.asp. This vulnerability allows attackers to execute arbitrary commands via the url_en parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4849
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.41% / 85.47%
||
7 Day CHG~0.00%
Published-18 May, 2025 | 02:31
Updated-24 May, 2025 | 00:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK N300RH cstecgi.cgi CloudACMunualUpdateUserdata command injection

A vulnerability was found in TOTOLINK N300RH 6.1c.1390_B20191101. It has been rated as critical. Affected by this issue is the function CloudACMunualUpdateUserdata of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument url leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-n300rh_firmwaren300rhN300RH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46233
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function msp_info.htm. This vulnerability allows attackers to execute arbitrary commands via the cmd parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46232
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function version_upgrade.asp. This vulnerability allows attackers to execute arbitrary commands via the path parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46454
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-28.60% / 96.65%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetWLanApcliSettings. This vulnerability allows attackers to execute arbitrary commands via the ApCliKeyStr parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823_pro_firmwaredir-823_pron/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46227
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-10.39% / 93.40%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function proxy_client.asp. This vulnerability allows attackers to execute arbitrary commands via the proxy_srv, proxy_srvport, proxy_lanip, proxy_lanport parameters.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46452
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetNetworkTomographySettings. This vulnerability allows attackers to execute arbitrary commands via the tomography_ping_address, tomography_ping_number, tomography_ping_size, tomography_ping_timeout, and tomography_ping_ttl parameters.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823_pro_firmwaredir-823_pron/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46230
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function upgrade_filter. This vulnerability allows attackers to execute arbitrary commands via the path and time parameters.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45613
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 81.76%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-xr1000_firmwarecbr40_firmwarerax80xr1000rax15rax75lax20mk62rax50rbs850d7000v2ms60_firmwarerax45rax40v2_firmwarerbr750ms80rax20rax200lax20_firmwarerax20_firmwarerax200_firmwarerbs750_firmwaremk62_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750d7000v2_firmwaremr60_firmwarerbs850_firmwarerbr850rax43rax80_firmwarerbr750_firmwarecbr750_firmwarems80_firmwarecbr40rbk752_firmwarerax35v2_firmwarerbk752rbs750rax15_firmwaremr80_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852ms60rbr850_firmwaremr80n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45624
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.19% / 79.34%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, R7000 before 1.0.11.110, R7100LG before 1.0.0.72, R7900 before 1.0.4.30, R8000 before 1.0.4.62, XR300 before 1.0.3.56, R7000P before 1.3.2.132, R8500 before 1.0.2.144, R6900P before 1.3.2.132, and R8300 before 1.0.2.144.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r8500d8500r8300_firmwared7000v2_firmwarer8000xr300r7000r6900pr7100lgr7900r7000pr6900p_firmwarer8500_firmwarer7100lg_firmwared7000v2r8300xr300_firmwarer7900_firmwarer7000_firmwared8500_firmwarer8000_firmwarer7000p_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45630
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-10||CRITICAL
EPSS-1.62% / 82.29%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:32
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwarerbs750_firmwarecbr750rbs850_firmwarerbr850rbr750_firmwarecbr750_firmwarecbr40rbs850rbk752_firmwarerbk752rbr750rbs750rbk852_firmwarerbk852rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46455
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.70%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStationSettings. This vulnerability allows attackers to execute arbitrary commands via the station_access_enable parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823_pro_firmwaredir-823_pron/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45623
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.3||HIGH
EPSS-1.61% / 82.26%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R7800 before 1.0.2.74, R9000 before 1.0.5.2, and XR500 before 2.3.2.66.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-r7800r9000_firmwarexr500_firmwarer7800_firmwarer9000xr500n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45998
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.70%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the LocalIPAddress parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_firmwaredir-882n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46226
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.70%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function wget_test.asp. This vulnerability allows attackers to execute arbitrary commands via the url parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45619
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.02% / 77.73%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR1020 before 2.6.3.58, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RBS50Y before 2.7.3.22, WNR2000v5 before 1.0.0.76, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, RAX10 before 1.0.2.88, RAX120 before 1.2.0.16, RAX70 before 1.0.2.88, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, R6700AX before 1.0.2.88, RAX120v2 before 1.2.0.16, RAX78 before 1.0.2.88, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR350 before 4.3.4.7, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS350 before 4.3.4.7, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK352 before 4.3.4.7, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax70rbk12rbk50_firmwareex6150v2_firmwarer8900_firmwarerbr40_firmwarerbr350_firmwareex6410ex6420_firmwareex7300v2_firmwarewnr2000v5_firmwareex6250_firmwarerbk352xr700_firmwareex7300rbk12_firmwarerax10rax120v2rbs40rbs50y_firmwarer8900rbs40_firmwarer9000_firmwarerbr10rax78_firmwarerbs10_firmwareex6410_firmwarelbr1020_firmwarerbs20rbs50_firmwarerbs50yr9000ex6200v2_firmwareex6400v2ex6100v2ex7700_firmwarer7800rax120_firmwarerbs10wnr2000v5r7800_firmwareex6100v2_firmwarerbk20_firmwarelbr1020xr700ex6400ex6200v2rbk20ex6400_firmwareex7300_firmwarerbs20_firmwareex6150v2r6700axrax120v2_firmwareex8000rbk40ex7320_firmwarerbr20rax78rax70_firmwarerbk40_firmwarerax120rax10_firmwareex6400v2_firmwareex6420ex7300v2ex8000_firmwareex6250rbr10_firmwarerbr40rbs50rbs350rbr50_firmwarerbr50ex7700lbr20rbr20_firmwareex7320rbk352_firmwarerbk50rbr350lbr20_firmwarerbs350_firmwarer6700ax_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45620
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.66% / 82.52%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20r6400_firmwaremk83_firmwarerax50r6900p_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3ms80rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwaremr80_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwaremr80xr1000_firmwarerax80xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwarer7850_firmwaremk62_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pms80_firmwarer6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwaremk83rax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarer6400rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45614
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.92% / 76.53%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-xr1000_firmwarerax80xr1000rax15rax75lax20mk62rax50rbs850d7000v2ms60_firmwarerax45rax40v2_firmwarerbr750rax20rax200lax20_firmwarerax20_firmwarerax200_firmwarerbs750_firmwaremk62_firmwaremr60rax35v2rax43_firmwarerax40v2mr60_firmwared7000v2_firmwarerbs850_firmwarerbr850rax43rax80_firmwarerbr750_firmwarerbk752_firmwarerax35v2_firmwarerbk752rbs750rax15_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbk852ms60rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46228
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.70%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function httpd_debug.asp. This vulnerability allows attackers to execute arbitrary commands via the time parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46457
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.70%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function ChgSambaUserSettings. This vulnerability allows attackers to execute arbitrary commands via the samba_name parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-823_pro_firmwaredir-823_pron/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-46229
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.05% / 88.81%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 05:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function usb_paswd.asp. This vulnerability allows attackers to execute arbitrary commands via the name parameter.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-7200gv2_firmwaredi-7200gv2n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-14505
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-3.00% / 86.91%
||
7 Day CHG~0.00%
Published-15 Jul, 2020 | 01:59
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Advantech iView, versions 5.6 and prior, has an improper neutralization of special elements used in a command (“command injection”) vulnerability. Successful exploitation of this vulnerability may allow an attacker to send a HTTP GET or POST request that creates a command string without any validation. The attacker may then remotely execute code.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-iviewAdvantech iView
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-45612
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.60% / 70.05%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20rax50r6900p_firmwareex7500_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80ex7500xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45738
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-25.81% / 96.39%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function UploadFirmwareFile. This vulnerability allows attackers to execute arbitrary commands via the parameter FileName.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45985
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-34.67% / 97.12%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45627
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.62% / 82.29%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850cbr750rbs850_firmwarerbr850rbk852rbk852_firmwarecbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45616
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 81.76%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax15lax20rax50r6900p_firmwarer7960prax45rs400r7000_firmwarerax40v2_firmwarerax20r7900prax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarerbk752_firmwarer7900_firmwarerbk852r7900p_firmwarelax20_firmwarems60r8000_firmwarexr1000_firmwarerax80xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarerbr750_firmwarer7000prax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45876
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.34% / 89.20%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 10:27
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by unauthenticated command injection. The url parameter of the function module downloadAndUpdate is vulnerable to an command Injection. Unfiltered user input is used to generate code which then gets executed when downloading new firmware.

Action-Not Available
Vendor-garon/a
Product-wallbox_gtbwallbox_glbwallbox_glb_firmwarewallbox_gtb_firmwarewallbox_gtc_firmwarewallbox_gtcn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45988
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-ac1900_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-ac1900bl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44881
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-8.90% / 92.78%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_firmwaredir-882n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45984
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-ac1900_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-ac1900bl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44620
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.92% / 88.62%
||
7 Day CHG~0.00%
Published-11 Mar, 2022 | 15:54
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exits in TOTOLINK A3100R <=V4.1.2cu.5050_B20200504 in adm/ntm.asp via the hosTime parameters.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a3100ra3100r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45987
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1_firmwarebl-ac2100_az3bl-f1200_at1bl-wr9000_firmwareblac450m_ae4bl-x26_da3_firmwarebl-x26_ac8_firmwarebl-wr9000blac450m_ae4_firmwarebl-lte300bl-lte300_firmwarebl-x26_da3bl-x26_ac8bl-ac2100_az3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44084
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.05% / 84.28%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 00:00
Updated-30 May, 2025 | 16:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-link DI-8100 16.07.26A1 is vulnerable to Command Injection. An attacker can exploit this vulnerability by crafting specific HTTP requests, triggering the command execution flaw and gaining the highest privilege shell access to the firmware system.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-8100g_firmwaredi-8100n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 22
  • 23
  • Next
Details not found