Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2024-44859

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-04 Sep, 2024 | 00:00
Updated At-04 Sep, 2024 | 16:04
Rejected At-
Credits

Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:04 Sep, 2024 | 00:00
Updated At:04 Sep, 2024 | 16:04
Rejected At:
▼CVE Numbering Authority (CNA)

Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://github.com/Ha0-Y/IoT/blob/main/tenda-F1201/WrlExtraGet.md
N/A
Hyperlink: https://github.com/Ha0-Y/IoT/blob/main/tenda-F1201/WrlExtraGet.md
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Vendor
Tenda Technology Co., Ltd.tenda
Product
fh1201_firmware
CPEs
  • cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • 1.2.0.14
Problem Types
TypeCWE IDDescription
CWECWE-121CWE-121 Stack-based Buffer Overflow
Type: CWE
CWE ID: CWE-121
Description: CWE-121 Stack-based Buffer Overflow
Metrics
VersionBase scoreBase severityVector
3.18.0HIGH
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.0
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:04 Sep, 2024 | 16:15
Updated At:05 Sep, 2024 | 12:53

Tenda FH1201 v1.2.0.14 has a stack buffer overflow vulnerability in `formWrlExtraGet`.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.0HIGH
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.0
Base severity: HIGH
Vector:
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-121Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-121
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/Ha0-Y/IoT/blob/main/tenda-F1201/WrlExtraGet.mdcve@mitre.org
N/A
Hyperlink: https://github.com/Ha0-Y/IoT/blob/main/tenda-F1201/WrlExtraGet.md
Source: cve@mitre.org
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

725Records found

CVE-2025-3820
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-4.92% / 89.88%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 20:31
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiSysUplinkCheckSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644) and classified as critical. Affected by this issue is the function cgiSysUplinkCheckSet of the file /bin/httpd. The manipulation of the argument hostIp1/hostIp2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3803
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.34% / 57.29%
||
7 Day CHG~0.00%
Published-19 Apr, 2025 | 15:00
Updated-30 Jul, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W12/i24 httpd cgiSysScheduleRebootSet stack-based overflow

A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w12i24i24_firmwarew12_firmwareW12i24
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-33212
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.06% / 19.86%
||
7 Day CHG~0.00%
Published-23 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1206fh1206_firmwaren/afh1206_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32320
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.9||MEDIUM
EPSS-0.13% / 31.73%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac500ac500_firmwaren/aac500
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32317
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.25% / 49.04%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10ac10_firmwaren/aac10_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32313
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.06% / 17.80%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 15:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205fh1205_firmwaren/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32302
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.3||MEDIUM
EPSS-0.16% / 36.92%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-02 Aug, 2024 | 02:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32307
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.4||HIGH
EPSS-0.21% / 43.84%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 15:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205fh1205_firmwaren/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32305
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.26% / 50.39%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-06 Nov, 2024 | 16:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-n/aa18_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32316
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.62%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac500ac500_firmwaren/aac500_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32312
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5.7||MEDIUM
EPSS-0.06% / 17.80%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 14:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1203f1203_firmwaren/af1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32290
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.7||MEDIUM
EPSS-0.12% / 30.24%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w30ew30e_firmwaren/aw30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-3259
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.85% / 75.39%
||
7 Day CHG~0.00%
Published-04 Apr, 2025 | 17:31
Updated-07 Apr, 2025 | 18:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 SetOnlineDevName formSetDeviceName stack-based overflow

A vulnerability, which was classified as critical, has been found in Tenda RX3 16.03.13.11. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3rx3_firmwareRX3
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-11526
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.26% / 49.91%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 02:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 WifiMacFilterSet stack-based overflow

A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-0995
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-7.2||HIGH
EPSS-0.11% / 29.89%
||
7 Day CHG~0.00%
Published-29 Jan, 2024 | 02:00
Updated-02 Jun, 2025 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda W6 httpd wifiSSIDset formwrlSSIDset stack-based overflow

A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-w6w6_firmwareW6
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-32010
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-8.1||HIGH
EPSS-0.78% / 74.13%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 13:09
Updated-03 Nov, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability exists in the Cloud API functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted HTTP response can lead to arbitrary code execution. An attacker can send an HTTP response to trigger this vulnerability.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac6_firmwareac6AC6 V5.0
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29218
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.31% / 54.77%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-26 Mar, 2025 | 18:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w18e_firmwarew18en/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29215
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.38% / 59.97%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-25 Mar, 2025 | 17:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_43fdcc function at /goform/SetNetControlList.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12ax12_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32291
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.13% / 32.60%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 16:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w30ew30e_firmwaren/aw30e_firmwarew30e
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29214
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.29% / 52.95%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-25 Mar, 2025 | 17:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_42F69C function at /goform/setMacFilterCfg.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ax12ax12_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29118
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.22% / 45.02%
||
7 Day CHG~0.00%
Published-19 Mar, 2025 | 00:00
Updated-01 Apr, 2025 | 20:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 V16.03.34.06 was discovered to contain a stack overflow via the src parameter in the function sub_47D878.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8ac8_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29149
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.33% / 56.12%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-27 Mar, 2025 | 15:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda i12 V1.0.0.10(3805) was discovered to contain a buffer overflow via the ping1 parameter in the formSetAutoPing function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-i12i12_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29121
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.33% / 56.12%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-28 Mar, 2025 | 19:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was found in Tenda AC6 V15.03.05.16. The vulnerability affects the functionality of the /goform/fast_setting_wifi_set file form_fast_setting_wifi_set. Using the timeZone parameter causes a stack-based buffer overflow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6ac6_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29217
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.34% / 57.51%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-25 Mar, 2025 | 17:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w18e_firmwarew18en/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-32287
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.10% / 28.16%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 00:00
Updated-17 Mar, 2025 | 15:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-w30ew30e_firmwaren/aw30e_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29135
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.80% / 74.56%
||
7 Day CHG~0.00%
Published-24 Mar, 2025 | 00:00
Updated-01 Apr, 2025 | 19:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac7_firmwareac7n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29100
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.17% / 38.42%
||
7 Day CHG~0.00%
Published-24 Mar, 2025 | 00:00
Updated-01 Apr, 2025 | 20:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8 V16.03.34.06 is vulnerable to Buffer Overflow in the fromSetRouteStatic function via the parameter list.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8ac8_firmwaren/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29101
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.44% / 63.72%
||
7 Day CHG~0.00%
Published-20 Mar, 2025 | 00:00
Updated-25 Mar, 2025 | 17:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC8V4.0 V16.03.34.06 was discovered to contain a stack overflow via the deviceid parameter in the get_parentControl_list_Info function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac8_firmwareac8n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-29387
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.1||HIGH
EPSS-2.01% / 84.17%
||
7 Day CHG~0.00%
Published-14 Mar, 2025 | 00:00
Updated-17 Mar, 2025 | 19:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Tenda AC9 v1.0 V15.03.05.14_multi, the wanSpeed parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability, which can lead to remote arbitrary code execution.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-25454
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.94% / 76.76%
||
7 Day CHG~0.00%
Published-17 Apr, 2025 | 00:00
Updated-22 Apr, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanSpeed2.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10_firmwareac10n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-25455
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.80% / 74.56%
||
7 Day CHG~0.00%
Published-17 Apr, 2025 | 00:00
Updated-22 Apr, 2025 | 16:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via wanMTU2.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10_firmwareac10n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-25634
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.30% / 54.07%
||
7 Day CHG~0.00%
Published-05 Mar, 2025 | 00:00
Updated-10 Apr, 2025 | 18:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been found in Tenda AC15 15.03.05.19 in the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument src leads to stack-based buffer overflow.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30840
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.04% / 12.83%
||
7 Day CHG~0.00%
Published-15 Apr, 2024 | 00:00
Updated-14 Apr, 2025 | 13:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Stack Overflow vulnerability in Tenda AC15 v15.03.05.18 allows attackers to cause a denial of service via the LISTEN parameter in the fromDhcpListClient function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac15_firmwareac15n/aac15_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30589
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 49.35%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) firmware has a stack overflow vulnerability in the entrys parameter of the fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2993
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.05%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 QuickIndex formQuickIndex stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been classified as critical. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-258162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3012
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.57% / 69.05%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-15 Jan, 2025 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been declared as critical. This vulnerability affects the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-258298 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30585
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.62%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30594
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.62%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceMac parameter of the addWifiMacFilter function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2994
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.05%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 19:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 GetParentControlInfo stack-based overflow

A vulnerability was found in Tenda FH1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-258163. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-55482
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.15% / 35.96%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 00:00
Updated-25 Aug, 2025 | 01:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC6 V15.03.06.23_multi is vulnerable to Buffer Overflow in the formSetCfm function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac6_firmwareac6n/a
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-3006
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.45% / 64.18%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 22:31
Updated-15 Jan, 2025 | 18:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1205 2.0.0.7(775). This vulnerability affects the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258292. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-3010
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.55% / 68.54%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 23:31
Updated-15 Jan, 2025 | 18:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1205 setcfm formSetCfm stack-based overflow

A vulnerability was found in Tenda FH1205 2.0.0.7(775) and classified as critical. Affected by this issue is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258296. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205FH1205fh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-2988
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.33% / 56.05%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 17:31
Updated-15 Jan, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1203 fromRouteStatic fromSetRouteStatic stack-based overflow

A vulnerability classified as critical was found in Tenda FH1203 2.0.1.6. Affected by this vulnerability is the function fromSetRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument entrys leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-258157 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1203fh1203_firmwareFH1203fh1203_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-30623
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.62%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1205 v2.0.0.7(775) has a stack overflow vulnerability in the page parameter from fromDhcpListClient function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1205_firmwarefh1205n/afh1205_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30612
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.1||HIGH
EPSS-0.21% / 43.18%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-17 Mar, 2025 | 14:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC10U v15.03.06.48 has a stack overflow vulnerability in the deviceId, limitSpeed, limitSpeedUp parameter from formSetClientState function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac10u_firmwareac10un/aac10u_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30588
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-4.3||MEDIUM
EPSS-0.17% / 37.60%
||
7 Day CHG~0.00%
Published-28 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 17:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the schedStartTime parameter of the setSchedWifi function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-fh1202fh1202_firmwaren/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30636
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.08% / 24.62%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability via the PPPOEPassword parameter in the formQuickIndex function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1202_firmwaref1202n/afh1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-30639
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-0.06% / 17.80%
||
7 Day CHG~0.00%
Published-29 Mar, 2024 | 00:00
Updated-13 Mar, 2025 | 21:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda F1202 v1.2.0.20(408) has a stack overflow vulnerability in the page parameter of fromAddressNat function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-f1202_firmwaref1202n/af1202_firmware
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-2983
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.93% / 76.59%
||
7 Day CHG~0.00%
Published-27 Mar, 2024 | 16:00
Updated-10 Apr, 2025 | 18:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda FH1202 SetClientState formSetClientState stack-based overflow

A vulnerability was found in Tenda FH1202 1.2.0.14(408) and classified as critical. Affected by this issue is the function formSetClientState of the file /goform/SetClientState. The manipulation of the argument deviceId/limitSpeed/limitSpeedUp leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-258152. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-fh1202_firmwarefh1202FH1202fh1202
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-15180
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-8.6||HIGH
EPSS-0.14% / 33.69%
||
7 Day CHG+0.04%
Published-29 Dec, 2025 | 08:32
Updated-24 Feb, 2026 | 06:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda WH450 HTTP Request webExcptypemanFilte stack-based overflow

A vulnerability was identified in Tenda WH450 1.0.0.18. The affected element is an unknown function of the file /goform/webExcptypemanFilte of the component HTTP Request Handler. Such manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-wh450_firmwarewh450WH450
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 14
  • 15
  • Next
Details not found