Summary
Assigner-trendmicro
Assigner Org ID-7f7bd7df-cffe-4fdb-ab6d-859363b89272
Published At-22 Oct, 2024 | 18:28
Updated At-22 Oct, 2024 | 19:00
Rejected At-
Credits

An command injection vulnerability in Trend Micro Cloud Edge could allow a remote attacker to execute arbitrary code on affected appliances. Please note: authentication is not required in order to exploit this vulnerability.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:trendmicro
Assigner Org ID:7f7bd7df-cffe-4fdb-ab6d-859363b89272
Published At:22 Oct, 2024 | 18:28
Updated At:22 Oct, 2024 | 19:00
Rejected At:
▼CVE Numbering Authority (CNA)

An command injection vulnerability in Trend Micro Cloud Edge could allow a remote attacker to execute arbitrary code on affected appliances. Please note: authentication is not required in order to exploit this vulnerability.

Affected Products
Vendor
Trend Micro IncorporatedTrend Micro, Inc.
Product
Trend Micro Cloud Edge
Versions
Affected
  • From 5.6SP2, 7.0 before 5.6.3228, 7.0.1081 (semver)
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://success.trendmicro.com/en-US/solution/KA-0017998
N/A
https://www.zerodayinitiative.com/advisories/ZDI-24-1418/
N/A
Hyperlink: https://success.trendmicro.com/en-US/solution/KA-0017998
Resource: N/A
Hyperlink: https://www.zerodayinitiative.com/advisories/ZDI-24-1418/
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Vendor
Trend Micro Incorporatedtrendmicro
Product
cloud_edge
CPEs
  • cpe:2.3:a:trendmicro:cloud_edge:*:*:*:*:*:*:*:*
Default Status
unknown
Versions
Affected
  • From 5.6sp2 before 5.6.3228 (custom)
  • From 7.0 before 7.0.1081 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:security@trendmicro.com
Published At:22 Oct, 2024 | 19:15
Updated At:31 Jul, 2025 | 16:24

An command injection vulnerability in Trend Micro Cloud Edge could allow a remote attacker to execute arbitrary code on affected appliances. Please note: authentication is not required in order to exploit this vulnerability.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Trend Micro Incorporated
trendmicro
>>cloud_edge>>Versions from 5.6(inclusive) to 5.6.3228(exclusive)
cpe:2.3:a:trendmicro:cloud_edge:*:*:*:*:*:*:*:*
Trend Micro Incorporated
trendmicro
>>cloud_edge>>Versions from 7.0(inclusive) to 7.0.1081(exclusive)
cpe:2.3:a:trendmicro:cloud_edge:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://success.trendmicro.com/en-US/solution/KA-0017998security@trendmicro.com
Vendor Advisory
https://www.zerodayinitiative.com/advisories/ZDI-24-1418/security@trendmicro.com
Third Party Advisory
Hyperlink: https://success.trendmicro.com/en-US/solution/KA-0017998
Source: security@trendmicro.com
Resource:
Vendor Advisory
Hyperlink: https://www.zerodayinitiative.com/advisories/ZDI-24-1418/
Source: security@trendmicro.com
Resource:
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

805Records found

CVE-2024-2352
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.99% / 82.90%
||
7 Day CHG~0.00%
Published-10 Mar, 2024 | 01:31
Updated-05 Feb, 2025 | 13:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel swap baseApi.UpdateDeviceSwap command injection

A vulnerability, which was classified as critical, has been found in 1Panel up to 1.10.1-lts. Affected by this issue is the function baseApi.UpdateDeviceSwap of the file /api/v1/toolbox/device/update/swap. The manipulation of the argument Path with the input 123123123\nopen -a Calculator leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. It is recommended to apply a patch to fix this issue. The identifier of this vulnerability is VDB-256304.

Action-Not Available
Vendor-n/aFIT2CLOUD Inc.
Product-1panel1Panel1panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44880
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-16.65% / 94.66%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link devices DIR_878 DIR_878_FW1.30B08_Hotfix_02 and DIR_882 DIR_882_FW1.30B06_Hotfix_02 were discovered to contain a command injection vulnerability in the system function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaredir-882dir-882_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45456
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-51.85% / 97.82%
||
7 Day CHG~0.00%
Published-06 Jan, 2022 | 12:35
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection

Apache kylin checks the legitimacy of the project before executing some commands with the project name passed in by the user. There is a mismatch between what is being checked and what is being used as the shell command argument in DiagnosisService. This may cause an illegal project name to pass the check and perform the following steps, resulting in a command injection vulnerability. This issue affects Apache Kylin 4.0.0.

Action-Not Available
Vendor-The Apache Software Foundation
Product-kylinApache Kylin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-31575
Matching Score-4
Assigner-MediaTek, Inc.
ShareView Details
Matching Score-4
Assigner-MediaTek, Inc.
CVSS Score-9.8||CRITICAL
EPSS-2.50% / 84.75%
||
7 Day CHG~0.00%
Published-06 Feb, 2023 | 00:00
Updated-26 Mar, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.

Action-Not Available
Vendor-MediaTek Inc.
Product-en7528en7528_firmwareen7580en7580_firmwareEN7528, EN7580
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-25029
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-2.41% / 84.49%
||
7 Day CHG~0.00%
Published-26 May, 2021 | 18:45
Updated-05 Aug, 2024 | 03:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Versa Director, the command injection is an attack in which the goal is execution of arbitrary commands on the host operating system via a vulnerable application. Command injection attacks are possible when an application passes unsafe user supplied data (forms, cookies, HTTP headers etc.) to a system shell. In this attack, the attacker-supplied operating system commands are usually executed with the privileges of the vulnerable application. Command injection attacks are possible largely due to insufficient input validation.

Action-Not Available
Vendor-n/aVersa Networks, Inc.
Product-versa_directorVersa Director
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-31726
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.42% / 88.59%
||
7 Day CHG~0.00%
Published-25 Apr, 2021 | 18:16
Updated-03 Aug, 2024 | 23:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Akuvox C315 115.116.2613 allows remote command Injection via the cfgd_server service. The attack vector is sending a payload to port 189 (default root 0.0.0.0).

Action-Not Available
Vendor-n/aAkuvox (SMART-PLUS PTE. LTD.)
Product-c315_firmwarec315n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-22651
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.07% / 88.09%
||
7 Day CHG~0.00%
Published-24 Jan, 2024 | 00:00
Updated-10 Sep, 2024 | 21:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in the ssdpcgi_main function of cgibin binary in D-Link DIR-815 router firmware v1.04.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-815_firmwaredir-815n/adir-815_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-4120
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-65.55% / 98.43%
||
7 Day CHG~0.00%
Published-03 Aug, 2023 | 09:00
Updated-15 Oct, 2024 | 20:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Byzoro Smart S85F Management Platform importhtml.php command injection

A vulnerability was found in Byzoro Smart S85F Management Platform up to 20230722 and classified as critical. This issue affects some unknown processing of the file importhtml.php. The manipulation of the argument sql leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-235967. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-byzoroByzoro
Product-smart_s85fSmart S85F Management Platform
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-31573
Matching Score-4
Assigner-MediaTek, Inc.
ShareView Details
Matching Score-4
Assigner-MediaTek, Inc.
CVSS Score-9.8||CRITICAL
EPSS-2.50% / 84.75%
||
7 Day CHG~0.00%
Published-06 Feb, 2023 | 00:00
Updated-26 Mar, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.

Action-Not Available
Vendor-MediaTek Inc.
Product-en7528en7528_firmwareen7580en7580_firmwareEN7528, EN7580
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-22663
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.76% / 89.03%
||
7 Day CHG~0.00%
Published-23 Jan, 2024 | 00:00
Updated-30 May, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK_A3700R_V9.1.2u.6165_20211012has a command Injection vulnerability via setOpModeCfg

Action-Not Available
Vendor-n/aTOTOLINK
Product-a3700r_firmwarea3700rn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6618
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 17:31
Updated-27 Jun, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE wps.so SetWLanApcliSettings os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been classified as critical. Affected is the function SetWLanApcliSettings of the file wps.so. The manipulation of the argument PIN leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-44400
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8||HIGH
EPSS-14.93% / 94.29%
||
7 Day CHG~0.00%
Published-04 Sep, 2024 | 00:00
Updated-11 Oct, 2024 | 17:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was discovered in DI_8400-16.07.26A1, which has been classified as critical. This issue affects the upgrade_filter_asp function in the upgrade_filter.asp file. Manipulation of the path parameter can lead to command injection.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-8400di-8400_firmwaren/adi-8400_firmware
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-22729
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-90.81% / 99.61%
||
7 Day CHG~0.00%
Published-25 Jan, 2024 | 00:00
Updated-04 Jun, 2025 | 22:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETIS SYSTEMS MW5360 V1.0.1.3031 was discovered to contain a command injection vulnerability via the password parameter on the login page.

Action-Not Available
Vendor-n/aNetis Systems Co., Ltd.
Product-mw5360_firmwaremw5360n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-28960
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.31% / 91.30%
||
7 Day CHG~0.00%
Published-21 Sep, 2021 | 12:46
Updated-03 Aug, 2024 | 21:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Zoho ManageEngine Desktop Central before build 10.0.683 allows unauthenticated command injection due to improper handling of an input command in on-demand operations.

Action-Not Available
Vendor-n/aManageEngine (Zoho Corporation Pvt. Ltd.)
Product-desktop_centraln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38863
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.86%
||
7 Day CHG~0.00%
Published-15 Aug, 2023 | 00:00
Updated-09 Oct, 2024 | 13:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in COMFAST CF-XR11 v.2.7.2 allows an attacker to execute arbitrary code via the ifname and mac parameters in the sub_410074 function at bin/webmgnt.

Action-Not Available
Vendor-comfastn/acomfast
Product-cf-xr11cf-xr11_firmwaren/acf-xr11
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-27185
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-11.18% / 93.23%
||
7 Day CHG~0.00%
Published-10 Feb, 2021 | 21:04
Updated-03 Aug, 2024 | 20:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The samba-client package before 4.0.0 for Node.js allows command injection because of the use of process.exec.

Action-Not Available
Vendor-samba-client_projectn/a
Product-samba-clientn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-23625
Matching Score-4
Assigner-Exodus Intelligence
ShareView Details
Matching Score-4
Assigner-Exodus Intelligence
CVSS Score-9.6||CRITICAL
EPSS-10.01% / 92.77%
||
7 Day CHG~0.00%
Published-25 Jan, 2024 | 23:41
Updated-29 May, 2025 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAP-1650 SUBSCRIBE Callback Command Injection Vulnerability

A command injection vulnerability exists in D-Link DAP-1650 devices when handling UPnP SUBSCRIBE messages. An unauthenticated attacker can exploit this vulnerability to gain command execution on the device as root.

Action-Not Available
Vendor-D-Link Corporation
Product-dap-1650dap-1650_firmwareDAP-1650
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-40146
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-6.8||MEDIUM
EPSS-0.97% / 75.78%
||
7 Day CHG~0.00%
Published-17 Apr, 2024 | 12:55
Updated-21 Aug, 2025 | 18:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A privilege escalation vulnerability exists in the /bin/login functionality of Peplink Smart Reader v1.2.0 (in QEMU). A specially crafted command line argument can lead to a limited-shell escape and elevated capabilities. An attacker can authenticate with hard-coded credentials and execute unblocked default busybox functionality to trigger this vulnerability.

Action-Not Available
Vendor-peplinkPeplinkpeplink
Product-smart_readersmart_reader_firmwareSmart Readersmart_reader
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2021-26728
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-10||CRITICAL
EPSS-0.64% / 69.55%
||
7 Day CHG~0.00%
Published-24 Oct, 2022 | 00:00
Updated-03 Aug, 2024 | 20:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
spx_restservice KillDupUsr_func Command Injection and Stack-Based Buffer Overflow

Command injection and stack-based buffer overflow vulnerabilities in the KillDupUsr_func function of spx_restservice allow an attacker to execute arbitrary code with the same privileges as the server user (root). This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0.

Action-Not Available
Vendor-lannerincLanner Inc
Product-iac-ast2500a_firmwareiac-ast2500aIAC-AST2500A
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6620
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE upgrade.so setUpgradeUboot os command injection

A vulnerability was found in TOTOLINK CA300-PoE 6.2c.884. It has been rated as critical. Affected by this issue is the function setUpgradeUboot of the file upgrade.so. The manipulation of the argument FileName leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-26729
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-10||CRITICAL
EPSS-0.36% / 57.37%
||
7 Day CHG~0.00%
Published-24 Oct, 2022 | 00:00
Updated-07 May, 2025 | 15:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
spx_restservice Login_handler_func Command Injection and Multiple Stack-Based Buffer Overflows

Command injection and multiple stack-based buffer overflows vulnerabilities in the Login_handler_func function of spx_restservice allow an attacker to execute arbitrary code with the same privileges as the server user (root). This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0.

Action-Not Available
Vendor-lannerincLanner Inc
Product-iac-ast2500a_firmwareiac-ast2500aIAC-AST2500A
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-26275
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.59% / 89.95%
||
7 Day CHG~0.00%
Published-18 Mar, 2021 | 23:34
Updated-03 Aug, 2024 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The eslint-fixer package through 0.1.5 for Node.js allows command injection via shell metacharacters to the fix function. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. The ozum/eslint-fixer GitHub repository has been intentionally deleted

Action-Not Available
Vendor-eslint-fixer_projectn/a
Product-eslint-fixern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-6621
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.81% / 85.58%
||
7 Day CHG~0.00%
Published-25 Jun, 2025 | 18:00
Updated-27 Jun, 2025 | 18:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK CA300-PoE ap.so QuickSetting os command injection

A vulnerability classified as critical has been found in TOTOLINK CA300-PoE 6.2c.884. This affects the function QuickSetting of the file ap.so. The manipulation of the argument hour/minute leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-ca300-poeca300-poe_firmwareCA300-PoE
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-26727
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-10||CRITICAL
EPSS-0.49% / 64.44%
||
7 Day CHG~0.00%
Published-24 Oct, 2022 | 00:00
Updated-07 May, 2025 | 14:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
spx_restservice SubNet_handler_func Multiple Command Injections and Stack-Based Buffer Overflows

Multiple command injections and stack-based buffer overflows vulnerabilities in the SubNet_handler_func function of spx_restservice allow an attacker to execute arbitrary code with the same privileges as the server user (root). This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0.

Action-Not Available
Vendor-lannerincLanner Inc
Product-iac-ast2500a_firmwareiac-ast2500aIAC-AST2500A
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-26731
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-9.1||CRITICAL
EPSS-0.33% / 55.38%
||
7 Day CHG~0.00%
Published-24 Oct, 2022 | 00:00
Updated-07 May, 2025 | 15:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
spx_restservice modifyUserb_func Command Injection and Multiple Stack-Based Buffer Overflows

Command injection and multiple stack-based buffer overflows vulnerabilities in the modifyUserb_func function of spx_restservice allow an authenticated attacker to execute arbitrary code with the same privileges as the server user (root). This issue affects: Lanner Inc IAC-AST2500A standard firmware version 1.10.0.

Action-Not Available
Vendor-lannerincLanner Inc
Product-iac-ast2500a_firmwareiac-ast2500aIAC-AST2500A
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5502
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.54% / 80.67%
||
7 Day CHG~0.00%
Published-03 Jun, 2025 | 14:00
Updated-06 Jun, 2025 | 17:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK X15 formMapReboot command injection

A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-x15x15_firmwareX15
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-787
Out-of-bounds Write
CVE-2019-19875
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.69% / 70.98%
||
7 Day CHG~0.00%
Published-27 Nov, 2020 | 16:21
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Arbitrary commands could be injected (using Python scripts) via the AprolCluster script that is invoked via sudo and thus executes with root privileges, a different vulnerability than CVE-2019-16364.

Action-Not Available
Vendor-n/aB&R Industrial Automation GmbH
Product-industrial_automation_aproln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5573
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.15% / 36.70%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 06:00
Updated-06 Jun, 2025 | 18:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L setSystemWizard setSystemControl os command injection

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been rated as critical. Affected by this issue is the function setSystemWizard/setSystemControl of the file /setSystemWizard. The manipulation of the argument AdminID leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932ldcs-932l_firmwareDCS-932L
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5606
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.07% / 76.88%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 19:00
Updated-10 Jun, 2025 | 15:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 SetIPTVCfg formSetIptv command injection

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetIptv of the file /goform/SetIPTVCfg. The manipulation of the argument list leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-40301
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.83% / 73.69%
||
7 Day CHG~0.00%
Published-07 Dec, 2023 | 00:00
Updated-28 May, 2025 | 16:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

NETSCOUT nGeniusPULSE 3.8 has a Command Injection Vulnerability.

Action-Not Available
Vendor-netscoutn/a
Product-ngeniuspulsen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2020-20951
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.17% / 91.21%
||
7 Day CHG~0.00%
Published-18 May, 2021 | 15:32
Updated-04 Aug, 2024 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Pluck-4.7.10-dev2 admin background, a remote command execution vulnerability exists when uploading files.

Action-Not Available
Vendor-pluck-cmsn/a
Product-pluckn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-41011
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-7.51% / 91.42%
||
7 Day CHG~0.00%
Published-14 Sep, 2023 | 00:00
Updated-25 Sep, 2024 | 19:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Command Execution vulnerability in China Mobile Communications China Mobile Intelligent Home Gateway v.HG6543C4 allows a remote attacker to execute arbitrary code via the shortcut_telnet.cg component.

Action-Not Available
Vendor-chinamobilen/achina_mobile_communications
Product-intelligent_home_gateway_firmwareintelligent_home_gatewayn/achina_mobile_intelligent_home_gateway
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-19874
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.31% / 79.03%
||
7 Day CHG~0.00%
Published-27 Nov, 2020 | 16:20
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. Some web scripts in the web interface allowed injection and execution of arbitrary unintended commands on the web server, a different vulnerability than CVE-2019-16364.

Action-Not Available
Vendor-n/aB&R Industrial Automation GmbH
Product-industrial_automation_aproln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-57105
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.36% / 57.48%
||
7 Day CHG+0.25%
Published-22 Aug, 2025 | 00:00
Updated-26 Aug, 2025 | 14:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The DI-7400G+ router has a command injection vulnerability, which allows attackers to execute arbitrary commands on the device. The sub_478D28 function in in mng_platform.asp, and sub_4A12DC function in wayos_ac_server.asp of the jhttpd program, with the parameter ac_mng_srv_host.

Action-Not Available
Vendor-n/a
Product-n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5621
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-0.57% / 67.52%
||
7 Day CHG~0.00%
Published-04 Jun, 2025 | 23:31
Updated-06 Jun, 2025 | 15:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-816 qosClassifier os command injection

A vulnerability has been found in D-Link DIR-816 1.10CNB05 and classified as critical. Affected by this vulnerability is the function qosClassifier of the file /goform/qosClassifier. The manipulation of the argument dip_address/sip_address leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-816dir-816_firmwareDIR-816
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-19872
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.65% / 69.83%
||
7 Day CHG~0.00%
Published-27 Nov, 2020 | 14:08
Updated-05 Aug, 2024 | 02:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364.

Action-Not Available
Vendor-n/aB&R Industrial Automation GmbH
Product-industrial_automation_aproln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-54424
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.1||HIGH
EPSS-0.15% / 36.86%
||
7 Day CHG+0.11%
Published-01 Aug, 2025 | 23:04
Updated-26 Aug, 2025 | 16:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
1Panel Agent Bypasses Certificate Verification Leading to Arbitrary Command Execution

1Panel is a web interface and MCP Server that manages websites, files, containers, databases, and LLMs on a Linux server. In versions 2.0.5 and below, the HTTPS protocol used for communication between the Core and Agent endpoints has incomplete certificate verification during certificate validation, leading to unauthorized interface access. Due to the presence of numerous command execution or high-privilege interfaces in 1Panel, this results in Remote Code Execution (RCE). This is fixed in version 2.0.6. The CVE has been translated from Simplified Chinese using GitHub Copilot.

Action-Not Available
Vendor-FIT2CLOUD Inc.1Panel (FIT2CLOUD Inc.)
Product-1panel1Panel
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-55591
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.76% / 90.12%
||
7 Day CHG~0.00%
Published-18 Aug, 2025 | 00:00
Updated-21 Aug, 2025 | 14:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK-A3002R v4.0.0-B20230531.1404 was discovered to contain a command injection vulnerability in the devicemac parameter in the formMapDel endpoint.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a3002ra3002r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.22%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-38865
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 77.57%
||
7 Day CHG~0.00%
Published-15 Aug, 2023 | 00:00
Updated-09 Oct, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

COMFAST CF-XR11 V2.7.2 has a command injection vulnerability detected at function sub_4143F0. Attackers can send POST request messages to /usr/bin/webmgnt and inject commands into parameter timestr.

Action-Not Available
Vendor-comfastn/acomfast
Product-cf-xr11cf-xr11_firmwaren/acf-xr11
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5447
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.56% / 67.45%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-55294
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.8||CRITICAL
EPSS-0.30% / 52.48%
||
7 Day CHG+0.09%
Published-19 Aug, 2025 | 17:34
Updated-20 Aug, 2025 | 14:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection via `format` option in screenshot-desktop

screenshot-desktop allows capturing a screenshot of your local machine. This vulnerability is a command injection issue. When user-controlled input is passed into the format option of the screenshot function, it is interpolated into a shell command without sanitization. This results in arbitrary command execution with the privileges of the calling process. This vulnerability is fixed in 1.15.2.

Action-Not Available
Vendor-bencevans
Product-screenshot-desktop
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38862
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.12% / 31.86%
||
7 Day CHG~0.00%
Published-15 Aug, 2023 | 00:00
Updated-09 Oct, 2024 | 13:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue in COMFAST CF-XR11 v.2.7.2 allows an attacker to execute arbitrary code via the destination parameter of sub_431F64 function in bin/webmgnt.

Action-Not Available
Vendor-comfastn/acomfast
Product-cf-xr11cf-xr11_firmwaren/acf-xr11
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-21488
Matching Score-4
Assigner-Snyk
ShareView Details
Matching Score-4
Assigner-Snyk
CVSS Score-7.3||HIGH
EPSS-2.28% / 84.03%
||
7 Day CHG~0.00%
Published-30 Jan, 2024 | 05:00
Updated-17 Jun, 2025 | 21:29
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Versions of the package network before 0.7.0 are vulnerable to Arbitrary Command Injection due to use of the child_process exec function without input sanitization. If (attacker-controlled) user input is given to the mac_address_for function of the package, it is possible for the attacker to execute arbitrary commands on the operating system that this package is being run on.

Action-Not Available
Vendor-forkhqn/a
Product-networknetwork
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38941
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-5.24% / 89.58%
||
7 Day CHG~0.00%
Published-03 Aug, 2023 | 00:00
Updated-17 Oct, 2024 | 16:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

django-sspanel v2022.2.2 was discovered to contain a remote command execution (RCE) vulnerability via the component sspanel/admin_view.py -> GoodsCreateView._post.

Action-Not Available
Vendor-ehco1996n/a
Product-django-sspaneln/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-39008
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.61% / 88.83%
||
7 Day CHG~0.00%
Published-09 Aug, 2023 | 00:00
Updated-10 Oct, 2024 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection vulnerability in the component /api/cron/settings/setJob/ of OPNsense Community Edition before 23.7 and Business Edition before 23.4.2 allows attackers to execute arbitrary system commands.

Action-Not Available
Vendor-opnsensen/a
Product-opnsensen/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-38690
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-5.8||MEDIUM
EPSS-0.13% / 33.65%
||
7 Day CHG~0.00%
Published-04 Aug, 2023 | 16:31
Updated-08 Oct, 2024 | 17:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
matrix-appservice-irc IRC command injection via admin commands containing newlines

matrix-appservice-irc is a Node.js IRC bridge for Matrix. Prior to version 1.0.1, it is possible to craft a command with newlines which would not be properly parsed. This would mean you could pass a string of commands as a channel name, which would then be run by the IRC bridge bot. Versions 1.0.1 and above are patched. There are no robust workarounds to the bug. One may disable dynamic channels in the config to disable the most common execution method but others may exist.

Action-Not Available
Vendor-The Matrix.org Foundation
Product-matrix_irc_bridgematrix-appservice-ircmatrix-appservice-irc
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2023-38866
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.14% / 77.57%
||
7 Day CHG~0.00%
Published-15 Aug, 2023 | 00:00
Updated-09 Oct, 2024 | 13:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

COMFAST CF-XR11 V2.7.2 has a command injection vulnerability detected at function sub_415588. Attackers can send POST request messages to /usr/bin/webmgnt and inject commands into parameter interface and display_name.

Action-Not Available
Vendor-comfastn/acomfast
Product-cf-xr11cf-xr11_firmwaren/acf-xr11
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-52688
Matching Score-4
Assigner-5f57b9bf-260d-4433-bf07-b6a79e9bb7d4
ShareView Details
Matching Score-4
Assigner-5f57b9bf-260d-4433-bf07-b6a79e9bb7d4
CVSS Score-9.8||CRITICAL
EPSS-0.11% / 30.51%
||
7 Day CHG~0.00%
Published-16 Jul, 2025 | 06:23
Updated-16 Jul, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection Vulnerability in the OmniAccess Stellar Web Management Interface

Successful exploitation of the vulnerability could allow an attacker to inject commands with root privileges on the access point, potentially leading to the loss of confidentiality, integrity, availability, and full control of the access point.

Action-Not Available
Vendor-Alcatel-Lucent Enterprise (ALE International)
Product-OmniAccess Stellar Products
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-17361
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-14.68% / 94.22%
||
7 Day CHG+1.54%
Published-17 Jan, 2020 | 01:16
Updated-05 Aug, 2024 | 01:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In SaltStack Salt through 2019.2.0, the salt-api NET API with the ssh client enabled is vulnerable to command injection. This allows an unauthenticated attacker with network access to the API endpoint to execute arbitrary code on the salt-api host.

Action-Not Available
Vendor-saltstackn/aCanonical Ltd.openSUSEDebian GNU/Linux
Product-ubuntu_linuxsaltdebian_linuxleapn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • ...
  • 16
  • 17
  • Next
Details not found