Palo Alto Networks Expedition contains a missing authentication vulnerability that allows an attacker with network access to takeover an Expedition admin account and potentially access configuration secrets, credentials, and other data.
Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.
It is possible to enumerate access card credentials via an unauthenticated network connection to the server in versions of Command Centre v8.20 prior to v8.20.1166(MR3), versions of 8.10 prior to v8.10.1211(MR5), versions of 8.00 prior to v8.00.1228(MR6), all versions of 7.90 and earlier. These credentials can then be used to encode low security cards to be used by the system where insecure card technologies are supported.
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
Dover Fueling Solutions ProGauge MagLink LX Consoles expose an undocumented and unauthenticated target communication framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentially leading to remote code execution.
Advantech iView, versions 5.6 and prior, has an improper authentication for critical function (CWE-306) issue. Successful exploitation of this vulnerability may allow an attacker to obtain the information of the user table, including the administrator credentials in plain text. An attacker may also delete the administrator account.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
HCL OneTest UI V9.5, V10.0, and V10.1 does not perform authentication for functionality that either requires a provable user identity or consumes a significant amount of resources.
Emerson Dixell XWEB-500 products are affected by arbitrary file write vulnerability in /cgi-bin/logo_extra_upload.cgi, /cgi-bin/cal_save.cgi, and /cgi-bin/lo_utils.cgi. An attacker will be able to write any file on the target system without any kind of authentication mechanism, and this can lead to denial of service and potentially remote code execution. Note: the product has not been supported since 2018 and should be removed or replaced
In Apache APISIX Dashboard before 2.10.1, the Manager API uses two frameworks and introduces framework `droplet` on the basis of framework `gin`, all APIs and authentication middleware are developed based on framework `droplet`, but some API directly use the interface of framework `gin` thus bypassing the authentication.
The previous default setting for Airflow's Experimental API was to allow all API requests without authentication, but this poses security risks to users who miss this fact. From Airflow 1.10.11 the default has been changed to deny all requests by default and is documented at https://airflow.apache.org/docs/1.10.11/security.html#api-authentication. Note this change fixes it for new installs but existing users need to change their config to default `[api]auth_backend = airflow.api.auth.backend.deny_all` as mentioned in the Updating Guide: https://github.com/apache/airflow/blob/1.10.11/UPDATING.md#experimental-api-will-deny-all-request-by-default
The Web portal of the WiFi module of VPNCrypt M10 2.6.5 allows unauthenticated users to send HTTP POST request to several critical Administrative functions such as, changing credentials of the Administrator account or connect the product to a rogue access point.
Arbitrary code execution vulnerability on Micro Focus Operation Bridge Reporter, affecting version 10.40 and earlier. The vulnerability could allow remote attackers to execute arbitrary code on affected installations of OBR.
If Apache TomEE is configured to use the embedded ActiveMQ broker, and the broker URI includes the useJMX=true parameter, a JMX port is opened on TCP port 1099, which does not include authentication. This affects Apache TomEE 8.0.0-M1 - 8.0.1, Apache TomEE 7.1.0 - 7.1.2, Apache TomEE 7.0.0-M1 - 7.0.7, Apache TomEE 1.0.0 - 1.7.5.
Missing Authentication in the registration feature of Lablup's BackendAI allows arbitrary users to create user accounts that can access private data even when registration is disabled.
A vulnerability in the web interface of Cisco RV132W ADSL2+ Wireless-N VPN Routers and Cisco RV134W VDSL2 Wireless-AC VPN Routers could allow an unauthenticated, remote attacker to view configuration parameters for an affected device, which could lead to the disclosure of confidential information. The vulnerability is due to the absence of user authentication requirements for certain pages that are part of the web interface and contain confidential information for an affected device. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device and examining the HTTP response to the request. A successful exploit could allow the attacker to view configuration parameters, including the administrator password, for the affected device. Cisco Bug IDs: CSCvg92739, CSCvh60172.
vBulletin before 5.5.6pl1, 5.6.0 before 5.6.0pl1, and 5.6.1 before 5.6.1pl1 has incorrect access control.
GE Grid Solutions Reason RT Clocks, RT430, RT431, and RT434, all firmware versions prior to 08A05. The device’s vulnerability in the web application could allow multiple unauthenticated attacks that could cause serious impact. The vulnerability may allow an unauthenticated attacker to execute arbitrary commands and send a request to a specific URL that could cause the device to become unresponsive. The unauthenticated attacker may change the password of the 'configuration' user account, allowing the attacker to modify the configuration of the device via the web interface using the new password. This vulnerability may also allow an unauthenticated attacker to bypass the authentication required to configure the device and reboot the system.
Minio console is a graphical user interface for the for MinIO operator. Minio itself is a multi-cloud object storage project. Affected versions are subject to an authentication bypass issue in the Operator Console when an external IDP is enabled. All users on release v0.12.2 and before are affected and are advised to update to 0.12.3 or newer. Users unable to upgrade should add automountServiceAccountToken: false to the operator-console deployment in Kubernetes so no service account token will get mounted inside the pod, then disable the external identity provider authentication by unset the CONSOLE_IDP_URL, CONSOLE_IDP_CLIENT_ID, CONSOLE_IDP_SECRET and CONSOLE_IDP_CALLBACK environment variable and instead use the Kubernetes service account token.
Burk Technology ARC Solo's password change mechanism can be utilized without proper authentication procedures, allowing an attacker to take over the device. A password change request can be sent directly to the device's HTTP endpoint without providing valid credentials. The system does not enforce proper authentication or session validation, allowing the password change to proceed without verifying the request's legitimacy.
An issue was discovered in Cicool builder 3.4.4 allowing attackers to reset the administrator's password via the /administrator/auth/reset_password endpoint.
AriaNg v0.1.0~v1.2.2 is affected by an incorrect access control vulnerability through not authenticating visitors' access rights.
register_send.php on D-Link DIR-850L REV. B (with firmware through FW208WWb02) devices does not require authentication, which can result in unintended enrollment in mydlink Cloud Services.
Sing-box is an open source proxy system. Affected versions are subject to an authentication bypass when specially crafted requests are sent to sing-box. This affects all SOCKS5 inbounds with user authentication and an attacker may be able to bypass authentication. Users are advised to update to sing-box 1.4.4 or to 1.5.0-rc.4. Users unable to update should not expose the SOCKS5 inbound to insecure environments.
An issue was discovered in CIPPlanner CIPAce 9.1 Build 2019092801. Upload.ashx allows remote attackers to execute arbitrary code by uploading and executing an ASHX file.
In JetBrains TeamCity before 2023.05.4 authentication bypass leading to RCE on TeamCity Server was possible
A Missing Authentication for Critical Function vulnerability in SUSE Manager allows anyone with access to the websocket at /rhn/websocket/minion/remote-commands to execute arbitrary commands as root. This issue affects Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 0.3.7-150600.3.6.2; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 0.3.7-150400.3.39.4; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2.
Red Lion SixTRAK and VersaTRAK Series RTUs with authenticated users enabled (UDR-A) any Sixnet UDR message will meet an authentication challenge over UDP/IP. When the same message is received over TCP/IP the RTU will simply accept the message with no authentication challenge.
PacsOne Server (PACS Server In One Box) below 7.1.1 is affected by incorrect access control, which can result in remotely gaining administrator privileges.
Chunghwa Telecom NOKIA G-040W-Q has a vulnerability of authentication bypass, which allows an unauthenticated remote attacker to bypass the authentication mechanism to log in to the device by an alternative URL. This makes it possible for unauthenticated remote attackers to log in as any existing users, such as an administrator, to perform arbitrary system operations or disrupt service.
Authentication bypass when an OAuth2 Client is using client_secret_jwt as its authentication method on affected 11.3 versions via specially crafted requests.
A first-factor authentication bypass vulnerability exists in the PingFederate with PingID Radius PCV when a MSCHAP authentication request is sent via a maliciously crafted RADIUS client request.
Missing authentication checks in the query.fcgi endpoint of NS3000 v8.1.1.125110 , v7.2.8.124852 , and v7.x and NS2000 v7.02.08 allows attackers to execute a session hijacking attack.
The variable import endpoint was not protected by authentication in Airflow >=2.0.0, <2.1.3. This allowed unauthenticated users to hit that endpoint to add/modify Airflow variables used in DAGs, potentially resulting in a denial of service, information disclosure or remote code execution. This issue affects Apache Airflow >=2.0.0, <2.1.3.
Vendor: The Apache Software Foundation Versions Affected: Apache OpenMeetings from 2.0.0 before 7.0.0 Description: Attacker can elevate their privileges in any room
SAP PowerDesigner - version 16.7, has improper access control which might allow an unauthenticated attacker to run arbitrary queries against the back-end database via Proxy.
Windows Mobile Device Management Elevation of Privilege Vulnerability
Missing Authentication for a Critical Function within the Kratos NGC Indoor Unit (IDU) before 11.4 allows remote attackers to obtain arbitrary control of the IDU/ODU system. Any attacker with layer-3 network access to the IDU can impersonate the Touch Panel Unit (TPU) within the IDU by sending crafted TCP requests to the IDU.
CasaOS is an open-source Personal Cloud system. Due to a lack of IP address verification an unauthenticated attackers can execute arbitrary commands as `root` on CasaOS instances. The problem was addressed by improving the detection of client IP addresses in `391dd7f`. This patch is part of CasaOS 0.4.4. Users should upgrade to CasaOS 0.4.4. If they can't, they should temporarily restrict access to CasaOS to untrusted users, for instance by not exposing it publicly.
WGS-80HPT-V2 and WGS-4215-8T2S are missing authentication that could allow an attacker to create an administrator account without knowing any existing credentials.
Zoho ManageEngine ADSelfService Plus through 6113 has an authentication bypass that can be exploited to steal the domain controller session token for identity spoofing, thereby achieving the privileges of the domain controller administrator. NOTE: the vendor's perspective is that they have "found no evidence or detail of a security vulnerability."
STW (aka Sensor-Technik Wiedemann) TCG-4 Connectivity Module DeploymentPackage_v3.03r0-Impala and DeploymentPackage_v3.04r2-Jellyfish and TCG-4lite Connectivity Module DeploymentPackage_v3.04r2-Jellyfish allow an attacker to gain full remote access with root privileges without the need for authentication, giving an attacker arbitrary remote code execution over LTE / 4G network via SMS.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
The web management interface of Okcat Parking Management Platform from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly access system functions. These functions include opening gates, viewing license plates and parking records, and restarting the system.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the control service, which listens on TCP port 9999 by default. The issue results from the lack of authentication prior to allowing alterations to the system configuration. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-10493.
VMware Cloud Director Appliance contains an authentication bypass vulnerability in case VMware Cloud Director Appliance was upgraded to 10.5 from an older version. On an upgraded version of VMware Cloud Director Appliance 10.5, a malicious actor with network access to the appliance can bypass login restrictions when authenticating on port 22 (ssh) or port 5480 (appliance management console) . This bypass is not present on port 443 (VCD provider and tenant login). On a new installation of VMware Cloud Director Appliance 10.5, the bypass is not present. VMware Cloud Director Appliance is impacted since it uses an affected version of sssd from the underlying Photon OS. The sssd issue is no longer present in versions of Photon OS that ship with sssd-2.8.1-11 or higher (Photon OS 3) or sssd-2.8.2-9 or higher (Photon OS 4 and 5).
An issue in Planet Technologies WDRT-1800AX v1.01-CP21 allows attackers to bypass authentication and escalate privileges to root via manipulation of the LoginStatus cookie.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
Zoho ManageEngine ServiceDesk Plus before 11302 is vulnerable to authentication bypass that allows a few REST-API URLs without authentication.
The resolution SAML SSO apps for Atlassian products allow a remote attacker to login to a user account when only the username is known (i.e., no other authentication is provided). The fixed versions are for Jira: 3.6.6.1, 4.0.12, 5.0.5; for Confluence 3.6.6, 4.0.12, 5.0.5; for Bitbucket 2.5.9, 3.6.6, 4.0.12, 5.0.5; for Bamboo 2.5.9, 3.6.6, 4.0.12, 5.0.5; and for Fisheye 2.5.9.
mage-ai is an open-source data pipeline tool for transforming and integrating data. Those who use Mage starting in version 0.8.34 and prior to 0.8.72 with user authentication enabled may be affected by a vulnerability. The terminal could be accessed by users who are not signed in or do not have editor permissions. Version 0.8.72 contains a fix for this issue.