Use of hard-coded credentials vulnerability in php component in Synology Calendar before 2.4.0-0761 allows remote attackers to obtain sensitive information via unspecified vectors.
bilde2910 Hauk v1.6.1 requires a hardcoded password which by default is blank. This hardcoded password is hashed but stored within the config.php file server-side as well as in clear-text on the android client device by default.
auth_db_config.py in Pyftpd 0.8.4 contains hard-coded usernames and passwords for the (1) test, (2) user, and (3) roxon accounts, which allows remote attackers to read arbitrary files from the FTP server.
In TOTOLINK A860R V4.1.2cu.5182_B20201027 there is a hard coded password for root in /etc/shadow.sample.
Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication using hard-coded administrator credentials. These accounts cannot be disabled.
Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key.
Firmware update files may expose password hashes for system accounts, which could allow a remote attacker to recover credentials and gain unauthorized access to the device.
IBM Security Verify Information Queue 10.0.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 230817.
'Hulu / フールー' App for Android from version 3.0.47 to the version prior to 3.1.2 uses a hard-coded API key for an external service. By exploiting this vulnerability, API key for an external service may be obtained by analyzing data in the app.
Dell Enterprise SONiC OS, 4.0.0, 4.0.1, contain a cryptographic key vulnerability in SSH. An unauthenticated remote attacker could potentially exploit this vulnerability, leading to unauthorized access to communication.
A hard-coded cryptographic key is used in FileWave before 14.6.3 and 14.7.x before 14.7.2. Exploitation could allow an unauthenticated actor to decrypt sensitive information saved in FileWave, and even send crafted requests.
Isode SWIFT v4.0.2 was discovered to contain hard-coded credentials in the Registry Editor. This allows attackers to access sensitive information such as user credentials and certificates.
The Text to Speech for WP (AI Voices by Mementor) plugin for WordPress is vulnerable to sensitive information exposure in all versions up to, and including, 1.9.8. This is due to the plugin containing hardcoded MySQL database credentials for the vendor's external telemetry server in the `Mementor_TTS_Remote_Telemetry` class. This makes it possible for unauthenticated attackers to extract and decode these credentials, gaining unauthorized write access to the vendor's telemetry database.
This vulnerability affects all of the company's products that also include the FW versions: update_i90_cv2.021_b20210104, update_i50_v1.0.55_b20200509, update_x6_v2.1.2_b202001127, update_b5_v2.0.9_b20200706. This vulnerability makes it possible to extract from the FW the existing user passwords on their operating systems and passwords.
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2 versions from 1.100E to 1.200J allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.
A hardcoded cryptographic key in Automation360 22 allows an attacker to decrypt exported RPA packages.
The configuration file is encrypted with a static key derived from a static five-character password which allows an attacker to decrypt this file. The application hashes this five-character password with the outdated and broken MD5 algorithm (no salt) and uses the first five bytes as the key for RC4. The configuration file is then encrypted with these parameters.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.
A vulnerability was determined in yeqifu carRental up to 3fabb7eae93d209426638863980301d6f99866b3. Affected by this vulnerability is an unknown functionality of the file /carRental_war/druid/login.html of the component Druid. Executing manipulation can lead to hard-coded credentials. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. This product operates on a rolling release basis, ensuring continuous delivery. Consequently, there are no version details for either affected or updated releases.
On Verizon 5G Home LVSKIHP InDoorUnit (IDU) 3.4.66.162 and OutDoorUnit (ODU) 3.33.101.0 devices, the CRTC and ODU RPC endpoints rely on a static certificate for access control. This certificate is embedded in the firmware, and is identical across the fleet of devices. An attacker need only download this firmware and extract the private components of these certificates (from /etc/lighttpd.d/ca.pem and /etc/lighttpd.d/server.pem) to gain access. (The firmware download location is shown in a device's upgrade logs.)
A vulnerability, which was classified as problematic, has been found in elunez eladmin up to 2.7. Affected by this issue is some unknown functionality of the file eladmin-system\src\main\resources\config\application-prod.yml of the component Druid. The manipulation of the argument login-username/login-password leads to use of default credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered.
A hardcoded privileged ID within Lumisxp v15.0.x to v16.1.x allows attackers to bypass authentication and access internal pages and other sensitive information.
IBM Security Verify Access Appliance 10.0.0 through 10.0.7 contains hard-coded credentials which it uses for its own inbound authentication that could be obtained by a malicious actor. IBM X-Force ID: 287317.
IBM Security Identity Manager 7.0.2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 200252.
Brocade SANnav OVA before v2.3.1 and v2.3.0a contain hard-coded credentials in the documentation that appear as the appliance's root password. The vulnerability could allow an unauthenticated attacker full access to the Brocade SANnav appliance.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
RunAsSpc 4.0 uses a universal and recoverable encryption key. In possession of a file encrypted by RunAsSpc, an attacker can recover the credentials that were used.
Use of Default Credentials, Hard-coded Credentials vulnerability in C2SGlobalSettings.dll in Milner ImageDirector Capture on Windows allows decryption of document archive files using credentials decrypted with hard-coded application encryption key. This issue affects ImageDirector Capture: from 7.0.9.0 before 7.6.3.25808.
QNAP VioCard 300 has hardcoded RSA private keys.
Apache Doris, prior to 1.0.0, used a hardcoded key and IV to initialize the cipher used for ldap password, which may lead to information disclosure.
HCL Aftermarket DPC is affected by SQL Injection which allows attacker to exploit this vulnerability to retrieve sensitive information from the database.
Hardcoded credentials in Dietly v1.25.0 for android allows attackers to gain sensitive information.
HCL Aftermarket DPC is affected by Hardcoded Sensitive Data which allows attacker to gain access to the source code or if it is stored in insecure repositories, they can easily retrieve these hardcoded secrets.
An Authentication Bypass vulnerability exists in the web interface in Zavio IP Cameras through 1.6.03 due to a hardcoded admin account found in boa.conf, which lets a remote malicious user obtain sensitive information.
IBM Security Verify Information Queue 1.0.6 and 1.0.7 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 198192.
Retty App for Android versions prior to 4.8.13 and Retty App for iOS versions prior to 4.11.14 uses a hard-coded API key for an external service. By exploiting this vulnerability, API key for an external service may be obtained by analyzing data in the app.
IBM Cognos Controller 11.0.0 and 11.0.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data.
IBM Security Verify Bridge contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 196618.
Use of a hard-coded cryptographic key to encrypt password data in CLI configuration in FortiManager 6.2.3 and below, FortiAnalyzer 6.2.3 and below may allow an attacker with access to the CLI configuration or the CLI backup file to decrypt the sensitive data, via knowledge of the hard-coded key.
PHOENIX CONTACT TC ROUTER 3002T-4G through 2.05.3, TC ROUTER 2002T-3G through 2.05.3, TC ROUTER 3002T-4G VZW through 2.05.3, TC ROUTER 3002T-4G ATT through 2.05.3, TC CLOUD CLIENT 1002-4G through 2.03.17, and TC CLOUD CLIENT 1002-TXTX through 1.03.17 devices contain a hardcoded certificate (and key) that is used by default for web-based services on the device. Impersonation, man-in-the-middle, or passive decryption attacks are possible if the generic certificate is not replaced by a device-specific certificate during installation.
PuddingBot is a group management bot. In version 0.0.6-b933652 and prior, the bot token is publicly exposed in main.py, making it accessible to malicious actors. The bot token has been revoked and new version is already running on the server. As of time of publication, the maintainers are planning to update code to reflect this change at a later date.
ZTE E8810/E8820/E8822 series routers have an information leak vulnerability, which is caused by hard-coded MQTT service access credentials on the device. The remote attacker could use this credential to connect to the MQTT server, so as to obtain information about other devices by sending specific topics. This affects:<ZXHN E8810, ZXHN E8820, ZXHN E8822><E8810 V1.0.26, E8810 V2.0.1, E8820 V1.1.3L, E8820 V2.0.13, E8822 V2.0.13>
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain a hard-coded cryptographic key vulnerability. A remote unauthenticated attacker may exploit this vulnerability to gain access to the appliance data for remotely managed devices.
IBM QRadar 7.3.0 to 7.3.3 Patch 2 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-ForceID: 175845.