The Sangfor Next-Gen Application Firewall version NGAF8.0.17 is vulnerable to an operating system command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary commands by sending a crafted HTTP POST request to the /LogInOut.php endpoint. This is due to mishandling of shell meta-characters in the "un" parameter.
The Sangfor Next-Gen Application Firewall version NGAF8.0.17 is vulnerable to an operating system command injection vulnerability. A remote and unauthenticated attacker can execute arbitrary commands by sending a crafted HTTP POST request to the /cgi-bin/login.cgi endpoint. This is due to mishandling of shell meta-characters in the PHPSESSID cookie.
A vulnerability has been found in Sangfor Operation and Maintenance Security Management System up to 3.0.12. The impacted element is an unknown function of the file /fort/audit/get_clip_img of the component HTTP POST Request Handler. Such manipulation of the argument frame/dirno leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was identified in Sangfor Operation and Maintenance Management System up to 3.0.12. Affected by this issue is the function SessionController of the file /isomp-protocol/protocol/session of the component SSH Protocol Handler. The manipulation of the argument keypassword leads to os command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Sangfor Operation and Maintenance Security Management System up to 3.0.12. This affects the function portValidate of the file /fort/ip_and_port/port_validate of the component HTTP POST Request Handler. Performing a manipulation of the argument port results in command injection. The attack can be initiated remotely. The exploit has been made public and could be used.
A vulnerability was determined in Sangfor Operation and Maintenance Security Management System up to 3.0.12. This impacts the function getInformation of the file /equipment/get_Information of the component HTTP POST Request Handler. Executing a manipulation of the argument fortEquipmentIp can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability has been found in Sangfor Operation and Maintenance Management System up to 3.0.8. This vulnerability affects the function uploadCN of the file VersionController.java. The manipulation of the argument filename leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Sangfor Operation and Maintenance Management System up to 3.0.8. Impacted is the function WriterHandle.getCmd of the file /isomp-protocol/protocol/getCmd. This manipulation of the argument sessionPath causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was identified in Sangfor Operation and Maintenance Management System up to 3.0.8. The affected element is the function SessionController of the file /isomp-protocol/protocol/session. Such manipulation of the argument Hostname leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in Sangfor Operation and Maintenance Security Management System 3.0. Impacted is an unknown function of the file /fort/portal_login of the component Frontend. This manipulation of the argument loginUrl causes command injection. The attack may be initiated remotely. The exploit has been publicly disclosed and may be utilized. Upgrading to version 3.0.11 and 3.0.12 is recommended to address this issue. It is advisable to upgrade the affected component.
The Sangfor Next-Gen Application Firewall version NGAF8.0.17 is vulnerable to an authentication bypass vulnerability. A remote and unauthenticated attacker can bypass authentication and access administrative functionality by sending HTTP requests using a crafted Y-forwarded-for header.
A security flaw has been discovered in Sangfor Operation and Maintenance Security Management System up to 3.0.12. This affects the function edit_pwd_mall of the file /fort/login/edit_pwd_mall. The manipulation of the argument flag results in weak password recovery. It is possible to launch the attack remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
A security flaw has been discovered in Sangfor Operation and Maintenance Management System up to 3.0.8. The impacted element is an unknown function of the file /fort/trust/version/common/common.jsp. Performing a manipulation of the argument File results in unrestricted upload. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function wget_test.asp. This vulnerability allows attackers to execute arbitrary commands via the url parameter.
In GenieACS 1.2.x before 1.2.8, the UI interface API is vulnerable to unauthenticated OS command injection via the ping host argument (lib/ui/api.ts and lib/ping.ts). The vulnerability arises from insufficient input validation combined with a missing authorization check.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects XR300 before 1.0.3.68, R7000P before 1.3.3.140, and R6900P before 1.3.3.140.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function ChgSambaUserSettings. This vulnerability allows attackers to execute arbitrary commands via the samba_name parameter.
An issue was discovered in Pascom Cloud Phone System before 7.20.x. In the management REST API, /services/apply in exd.pl allows remote attackers to execute arbitrary code via shell metacharacters.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetWLanApcliSettings. This vulnerability allows attackers to execute arbitrary commands via the ApCliKeyStr parameter.
An issue in symphony v.3.6.3 and before allows a remote attacker to execute arbitrary code via the log4j component.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function version_upgrade.asp. This vulnerability allows attackers to execute arbitrary commands via the path parameter.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7800 before 1.0.1.64, EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RAX120 before 1.2.0.16, RBS50Y before 1.0.0.56, WNR2000v5 before 1.0.0.76, XR450 before 2.3.2.114, XR500 before 2.3.2.114, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, EX6410 before 1.0.0.134, RBR10 before 2.6.1.44, RBR20 before 2.6.2.104, RBR40 before 2.6.2.104, RBR50 before 2.7.2.102, EX6420 before 1.0.0.134, RBS10 before 2.6.1.44, RBS20 before 2.6.2.104, RBS40 before 2.6.2.104, RBS50 before 2.7.2.102, EX6400v2 before 1.0.0.134, RBK12 before 2.6.1.44, RBK20 before 2.6.2.104, RBK40 before 2.6.2.104, and RBK50 before 2.7.2.102.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function httpd_debug.asp. This vulnerability allows attackers to execute arbitrary commands via the time parameter.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetNetCheckTools. This vulnerability allows attackers to execute arbitrary commands via the hostName parameter.
Command Execution vulnerability in China Mobile Communications China Mobile Intelligent Home Gateway v.HG6543C4 allows a remote attacker to execute arbitrary code via the shortcut_telnet.cg component.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function uploadPicture. This vulnerability allows attackers to execute arbitrary commands via the pic_name parameter.
An issue was discovered in Mutt before 1.10.1 and NeoMutt before 2018-07-16. They allow remote IMAP servers to execute arbitrary commands via backquote characters, related to the mailboxes command associated with an automatic subscription.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStaticRouteSettings. This vulnerability allows attackers to execute arbitrary commands via the staticroute_list parameter.
A Remote Command Execution (RCE) vulnerability exists in HNAP1/control/SetNetworkTomographySettings.php of D-Link Router DIR-846 DIR846A1_FW100A43.bin and DIR846enFW100A53DLA-Retail.bin because backticks can be used for command injection when judging whether it is a reasonable domain name.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function NTPSyncWithHost. This vulnerability allows attackers to execute arbitrary commands via the parameter host_time.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function usb_paswd.asp. This vulnerability allows attackers to execute arbitrary commands via the name parameter.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function upgrade_filter. This vulnerability allows attackers to execute arbitrary commands via the path and time parameters.
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by unauthenticated command injection. The url parameter of the function module downloadAndUpdate is vulnerable to an command Injection. Unfiltered user input is used to generate code which then gets executed when downloading new firmware.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22.
TOTOLINK A720R v4.1.5cu.470_B20200911 was discovered to contain a command injection vulnerability in the "Main" function. This vulnerability allows attackers to execute arbitrary commands via the QUERY_STRING parameter.
NETSCOUT nGeniusPULSE 3.8 has a Command Injection Vulnerability.
LG N1A1 NAS 3718.510 is affected by: Remote Command Execution. The impact is: execute arbitrary code (remote). The attack vector is: HTTP POST with parameters.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetStationSettings. This vulnerability allows attackers to execute arbitrary commands via the station_access_enable parameter.
Tenda routers G1 and G3 v15.11.0.17(9502)_CN were discovered to contain a command injection vulnerability in the function formSetUSBShareInfo. This vulnerability allows attackers to execute arbitrary commands via the usbOrdinaryUserName parameter.
D-Link device DI-7200GV2.E1 v21.04.09E1 was discovered to contain a command injection vulnerability in the function proxy_client.asp. This vulnerability allows attackers to execute arbitrary commands via the proxy_srv, proxy_srvport, proxy_lanip, proxy_lanport parameters.
D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the LocalIPAddress parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects EX6200v2 before 1.0.1.86, EX6250 before 1.0.0.134, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, LBR1020 before 2.6.3.58, LBR20 before 2.6.3.50, R7800 before 1.0.2.80, R8900 before 1.0.5.26, R9000 before 1.0.5.26, RBS50Y before 2.7.3.22, WNR2000v5 before 1.0.0.76, XR700 before 1.0.1.36, EX6150v2 before 1.0.1.98, EX7300 before 1.0.2.158, EX7320 before 1.0.0.134, RAX10 before 1.0.2.88, RAX120 before 1.2.0.16, RAX70 before 1.0.2.88, EX6100v2 before 1.0.1.98, EX6400 before 1.0.2.158, EX7300v2 before 1.0.0.134, R6700AX before 1.0.2.88, RAX120v2 before 1.2.0.16, RAX78 before 1.0.2.88, EX6410 before 1.0.0.134, RBR10 before 2.7.3.22, RBR20 before 2.7.3.22, RBR350 before 4.3.4.7, RBR40 before 2.7.3.22, RBR50 before 2.7.3.22, EX6420 before 1.0.0.134, RBS10 before 2.7.3.22, RBS20 before 2.7.3.22, RBS350 before 4.3.4.7, RBS40 before 2.7.3.22, RBS50 before 2.7.3.22, EX6400v2 before 1.0.0.134, RBK12 before 2.7.3.22, RBK20 before 2.7.3.22, RBK352 before 4.3.4.7, RBK40 before 2.7.3.22, and RBK50 before 2.7.3.22.
TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function UploadFirmwareFile. This vulnerability allows attackers to execute arbitrary commands via the parameter FileName.
D-Link device D-Link DIR-823-Pro v1.0.2 was discovered to contain a command injection vulnerability in the function SetWLanACLSettings. This vulnerability allows attackers to execute arbitrary commands via the wl(0).(0)_maclist parameter.