A command injection vulnerability exists in the Zingbox Inspector versions 1.286 and earlier, that allows for an authenticated user to execute arbitrary system commands in the CLI.
LiteSpeed Web Server Enterprise 5.4.11 contains an authenticated command injection vulnerability in the external app configuration interface. Authenticated administrators can inject shell commands through the 'Command' parameter in the server configuration, allowing remote code execution via path traversal and bash command injection.
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Rakuten Turbo 5G firmware version V1.3.18 and earlier. If this vulnerability is exploited, a remote authenticated attacker may execute an arbitrary OS command.
A Remote Code Execution (RCE) issue in the addon CUx-Daemon 1.11a of the eQ-3 Homematic CCU-Firmware 2.35.16 until 2.45.6 allows remote authenticated attackers to execute system commands as root remotely via a simple HTTP request.
In the "webupg" binary of D-Link DIR-825 G1, because of the lack of parameter verification, attackers can use "cmd" parameters to execute arbitrary system commands after obtaining authorization.
A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind. This vulnerability only affects products that are no longer supported by the maintainer.
AdRem NetCrunch 10.6.0.4587 allows Remote Code Execution. In the NetCrunch web client, a read-only administrator can execute arbitrary code on the server running the NetCrunch server software.
There is remote authenticated OS command injection on TP-Link Archer C20i 0.9.1 3.2 v003a.0 Build 170221 Rel.55462n devices vie the X_TP_ExternalIPv6Address HTTP parameter, allowing a remote attacker to run arbitrary commands on the router with root privileges.
In QuickBox Pro v2.5.8 and below, the config.php file has a variable which takes a GET parameter value and parses it into a shell_exec(''); function without properly sanitizing any shell arguments, therefore remote code execution is possible. Additionally, as the media server is running as root by default attackers can use the sudo command within this shell_exec(''); function, which allows for privilege escalation by means of RCE.
An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the MTU field to SetWanSettings.
Improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability in mail sending and receiving component in Synology Mail Station before 20211105-10315 allows remote authenticated users to execute arbitrary commands via unspecified vectors.
Gerapy is a distributed crawler management framework. Gerapy prior to version 0.9.8 is vulnerable to remote code execution, and this issue is patched in version 0.9.8.
A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
An issue was discovered on D-Link DIR-818LW devices from 2.05.B03 to 2.06B01 BETA. There is a command injection in HNAP1 SetWanSettings via an XML injection of the value of the Gateway key.
Multiple vulnerabilities in the web-based user interface (Web UI) of Cisco IOS XE Software could allow an authenticated, remote attacker to execute commands with elevated privileges on the affected device. For more information about these vulnerabilities, see the Details section of this advisory.
Citrix SD-WAN 10.2.x before 10.2.3 and NetScaler SD-WAN 10.0.x before 10.0.8 have Improper Input Validation (issue 5 of 6).
A improper neutralization of special elements used in an os command ('os command injection') in Fortinet FortiWLM version 8.6.2 and below, version 8.5.2 and below, version 8.4.2 and below, version 8.3.2 and below allows attacker to execute unauthorized code or commands via crafted HTTP requests to the alarm dashboard and controller config handlers.
A improper neutralization of special elements used in an os command ('os command injection') in Fortinet FortiWeb version 6.4.1 and 6.4.0, version 6.3.15 and below, version 6.2.6 and below allows attacker to execute unauthorized code or commands via crafted HTTP requests.
A vulnerability was found in Sapido BR270n, BRC76n, GR297 and RB1732 and classified as critical. Affected by this issue is some unknown functionality of the file ip/syscmd.htm. The manipulation leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-214592.
An issue was discovered on D-Link DIR-818LW devices with firmware 2.06betab01. There is a command injection in HNAP1 (exploitable with Authentication) via shell metacharacters in the Type field to SetWanSettings.
MitraStar GPT-2541GNAC-N1 (HGU) 100VNZ0b33 devices allow remote authenticated users to obtain root access by executing command "deviceinfo show file &&/bin/bash" because of incorrect sanitization of parameter "path".
A shell command injection in the HW Events SNMP community in XoruX LPAR2RRD and STOR2RRD before 7.30 allows authenticated remote attackers to execute arbitrary shell commands as the user running the service.
A Remote Code Execution (RCE) vulnerability exists in Ruijie Networks Ruijie RG-EW Series Routers up to ReyeeOS 1.55.1915 / EW_3.0(1)B11P55 via the updateVersion function in /cgi-bin/luci/api/wireless.
Multiple vulnerabilities in the web-based user interface (Web UI) of Cisco IOS XE Software could allow an authenticated, remote attacker to execute commands with elevated privileges on the affected device. For more information about these vulnerabilities, see the Details section of this advisory.
ZeroShell 3.9.5 has a command injection vulnerability in /cgi-bin/kerbynet IP parameter, which may allow an authenticated attacker to execute system commands.
An issue was discovered in ONAP SDNC before Dublin. By executing sla/printAsGv with a crafted module parameter, an authenticated user can execute an arbitrary command. All SDC setups that include admportal are affected.
The affected product is vulnerable to a parameter injection via passphrase, which enables the attacker to supply uncontrolled input.
A privilege escalation vulnerability exists in SolarWinds Serv-U before 15.1.7 for Linux.
The Device42 Remote Collector before 17.05.01 does not sanitize user input in its SNMP Connectivity utility. This allows an authenticated attacker (with access to the console application) to execute arbitrary OS commands and escalate privileges.
TP-Link wifi router TL-WR802N V4(JP), with firmware version prior to 211202, is vulnerable to OS command injection.
There is a Potential Zip Slip Vulnerability and OS Command Injection Vulnerability on the management system of baserCMS. Users with permissions to upload files may upload crafted zip files which may execute arbitrary commands on the host operating system. This is a vulnerability that needs to be addressed when the management system is used by an unspecified number of users. If you are eligible, please update to the new version as soon as possible.
An issue was discovered in ONAP SDNC before Dublin. By executing sla/printAsXml with a crafted module parameter, an authenticated user can execute an arbitrary command. All SDC setups that include admportal are affected.
A improper neutralization of special elements used in a command ('command injection') in Fortinet FortiExtender version 7.0.1 and below, 4.2.3 and below, 4.1.7 and below allows an authenticated attacker to execute privileged shell commands via CLI commands including special characters
DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the name parameter in the run_command function.
DrayTek Vigor3900 v1.5.1.6 was discovered to contain an authenticated command injection vulnerability via the value parameter in the filter_string function.
Authenticated Semi-Blind Command Injection (via Parameter Injection) exists on Altus Nexto, Nexto Xpress, and Hadron Xtorm devices via the getlogs.cgi tcpdump feature. This affects Nexto NX3003 1.8.11.0, Nexto NX3004 1.8.11.0, Nexto NX3005 1.8.11.0, Nexto NX3010 1.8.3.0, Nexto NX3020 1.8.3.0, Nexto NX3030 1.8.3.0, Nexto NX5100 1.8.11.0, Nexto NX5101 1.8.11.0, Nexto NX5110 1.1.2.8, Nexto NX5210 1.1.2.8, Nexto Xpress XP300 1.8.11.0, Nexto Xpress XP315 1.8.11.0, Nexto Xpress XP325 1.8.11.0, Nexto Xpress XP340 1.8.11.0, and Hadron Xtorm HX3040 1.7.58.0.
There is a command injection vulnerability that may allow an attacker to inject malicious input on the device's operating system.
Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
app/operator_panel/exec.php in the Operator Panel module in FusionPBX 4.4.3 suffers from a command injection vulnerability due to a lack of input validation that allows authenticated non-administrative attackers to execute commands on the host. This can further lead to remote code execution when combined with an XSS vulnerability also present in the FusionPBX Operator Panel module.
An issue was discovered in Softing uaGate SI 1.60.01. A CGI script is vulnerable to command injection with a maliciously crafted url parameter.
D-Link DIR-846W A1 FW100A43 was discovered to contain a remote command execution (RCE) vulnerability via the wl(0).(0)_ssid parameter. This vulnerability is exploited via a crafted POST request.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
IBM FileNet Content Manager 5.5.4, 5.5.6, and 5.5.7 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 212346.
OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings.
A low privileged remote attacker can read and write files as root due to improper neutralization of special elements in the variable EMAIL_RELAY_PASSWORD in mGuard devices.
A low privileged remote attacker can trigger the execution of arbitrary OS commands as root due to improper neutralization of special elements in the variable EMAIL_NOTIFICATION.TO in mGuard devices.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).