Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-29905

Summary
Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-16 Apr, 2025 | 17:37
Updated At-16 Apr, 2025 | 18:04
Rejected At-
Credits

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:16 Apr, 2025 | 17:37
Updated At:16 Apr, 2025 | 18:04
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)

Affected Products
Vendor
Siemens AGSiemens
Product
TeleControl Server Basic
Default Status
unknown
Versions
Affected
  • From 0 before V3.1.2.2 (custom)
Problem Types
TypeCWE IDDescription
CWECWE-89CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Type: CWE
CWE ID: CWE-89
Description: CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-443402.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-443402.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:16 Apr, 2025 | 18:16
Updated At:19 Aug, 2025 | 14:48

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>telecontrol_server_basic>>Versions before 3.1.2.2(exclusive)
cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-89Primaryproductcert@siemens.com
CWE ID: CWE-89
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-443402.htmlproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-443402.html
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1917Records found

CVE-2025-32851
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32822
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'DeleteProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32860
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32834
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariablesWithImport' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32823
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32864
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-32859
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:38
Updated-19 Aug, 2025 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'LockWebServerGatewaySettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31352
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31353
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateOpcSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25916)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31351
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateProject' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25917)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31350
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateBufferingSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25918)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31349
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateSmtpSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25919)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-31343
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateTcmSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25920)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30030
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30003
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30032
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25921)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30031
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateUsers' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25922)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-30002
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.7||HIGH
EPSS-0.18% / 40.52%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 17:37
Updated-19 Aug, 2025 | 14:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)

Action-Not Available
Vendor-Siemens AG
Product-telecontrol_server_basicTeleControl Server Basic
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-27941
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.29% / 78.88%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected client systems do not properly sanitize input data before sending it to the SQL server. An attacker could use this vulnerability to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-10916
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.44% / 62.25%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7simatic_wincc_runtime_professionalsimatic_wincc_\(tia_portal\)SIMATIC WinCC Runtime Professional V13SIMATIC WinCC (TIA Portal) V14SIMATIC WinCC (TIA Portal) V13SIMATIC WinCC Runtime Professional V14SIMATIC PCS 7 V8.2SIMATIC WinCC V7.3SIMATIC PCS 7 V9.0SIMATIC WinCC (TIA Portal) V15SIMATIC PCS 7 V8.1SIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC PCS 7 V8.0 and earlierSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2024-27940
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.96% / 75.61%
||
7 Day CHG~0.00%
Published-14 May, 2024 | 10:02
Updated-06 Feb, 2025 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow any authenticated user to send arbitrary SQL commands to the SQL server. An attacker could use this vulnerability to compromise the whole database.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_crossbowRUGGEDCOM CROSSBOWruggedcom_crossbow
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2021-33729
Matching Score-10
Assigner-Siemens
ShareView Details
Matching Score-10
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.32% / 79.09%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). An authenticated attacker that is able to import firmware containers to an affected system could execute arbitrary commands in the local database.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2019-10918
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.38% / 58.63%
||
7 Day CHG~0.00%
Published-14 May, 2019 | 19:54
Updated-04 Aug, 2024 | 22:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7simatic_wincc_runtime_professionalsimatic_wincc_\(tia_portal\)SIMATIC WinCC Runtime Professional V13SIMATIC WinCC (TIA Portal) V14SIMATIC WinCC (TIA Portal) V13SIMATIC WinCC Runtime Professional V14SIMATIC PCS 7 V8.2SIMATIC WinCC V7.3SIMATIC PCS 7 V9.0SIMATIC WinCC (TIA Portal) V15SIMATIC PCS 7 V8.1SIMATIC WinCC Runtime Professional V15SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC PCS 7 V8.0 and earlierSIMATIC WinCC V7.2 and earlier
CWE ID-CWE-749
Exposed Dangerous Method or Function
CVE-2022-32251
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.30% / 53.24%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-21 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). There is a missing authentication verification for a resource used to change the roles and permissions of a user. This could allow an attacker to change the permissions of any user and gain the privileges of an administrative user.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-306
Missing Authentication for Critical Function
CVE-2022-32262
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-2.15% / 83.56%
||
7 Day CHG~0.00%
Published-14 Jun, 2022 | 09:22
Updated-21 Apr, 2025 | 13:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains a file upload server that is vulnerable to command injection. An attacker could use this to achieve arbitrary code execution.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2022-31765
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.18% / 40.16%
||
7 Day CHG~0.00%
Published-11 Oct, 2022 | 00:00
Updated-21 Apr, 2025 | 13:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Affected devices do not properly authorize the change password function of the web interface. This could allow low privileged users to escalate their privileges.

Action-Not Available
Vendor-Siemens AG
Product-6gk5788-1gd00-0aa06gk5328-4ss00-2ar3_firmware6gk5876-4aa00-2da26gk5774-1fx00-0aa06gk5748-1gy01-0aa06gk5748-1gd00-0ab0_firmware6gk5766-1ge00-7da0_firmware6gk5763-1al00-3aa06gk5826-2ab00-2ab26gk5788-2gd00-0ta0_firmware6gk5786-2fc00-0ac06gk5766-1ge00-7da06gk5788-1gy01-0aa0_firmware6gk5774-1fy00-0ta06gk5552-0aa00-2ar26gk5778-1gy00-0tb06gk5622-2gs00-2ac2_firmware6gk5722-1fc00-0ac0_firmware6gk5528-0ar00-2hr26gk5208-0ga00-2ac2_firmware6gk5552-0ar00-2hr2_firmware6gk5526-8gs00-4ar26gk5526-8gr00-4ar2_firmware6gk5204-0ba00-2gf2_firmware6gk5408-4gq00-2am26gk5208-0ha00-2ts6_firmware6gk5524-8gr00-3ar2_firmware6gk5788-1gd00-0aa0_firmware6ag1216-4bs00-7ac26gk5856-2ea00-3da16gk5722-1fc00-0aa0_firmware6gk5722-1fc00-0ac06gk5324-0ba00-3ar36gk5205-3bf00-2tb2_firmware6gk5524-8gs00-2ar2_firmware6gk5786-2fc00-0ac0_firmware6gk5761-1fc00-0aa0_firmware6gk5216-3rs00-2ac26gk5788-2gy01-0ta0_firmware6gk5552-0ar00-2ar2_firmware6gk5208-0ga00-2ac26gk5213-3bb00-2tb2_firmware6gk5524-8gr00-4ar2_firmware6gk5216-0ha00-2es6_firmware6gk5552-0aa00-2hr26gk5788-1gd00-0ab0_firmware6gk5734-1fx00-0ab6_firmware6gk5204-0ba00-2gf26gk5786-1fc00-0ab0_firmware6gk5786-2fc00-0aa0_firmware6gk5328-4fs00-3ar36gk5206-2rs00-2ac2_firmware6gk5722-1fc00-0aa06gk5213-3bd00-2ab2_firmware6gk5876-4aa00-2da2_firmware6gk5856-2ea00-3aa16gk5213-3bd00-2tb26gk5876-3aa02-2ba2_firmware6gk5766-1je00-3da0_firmware6gk5206-2rs00-5ac2_firmware6gk5876-4aa00-2ba26gk5408-8gs00-2am26gk5788-2gd00-0aa0_firmware6gk5205-3bb00-2tb26gk5208-0ua00-5es66gk6108-4am00-2da2_firmware6ag1208-0ba00-7ac26gk5786-2hc00-0ab06gk5526-8gr00-2ar2_firmware6gk5748-1gd00-0ab06gk5208-0ra00-2ac2_firmware6gk5748-1fc00-0ab0_firmware6gk5734-1fx00-0aa66gk5761-1fc00-0ab06gk5224-4gs00-2tc26gk5216-0ba00-2ac26gk5788-2gd00-0tb06gk5216-4bs00-2ac26gk5734-1fx00-0ab06gk5766-1je00-7da06gk5876-3aa02-2ea26gk5766-1ge00-7db06gk5216-0ha00-2as66gk5216-0ha00-2es66gk5224-0ba00-2ac26gk5328-4fs00-2rr3_firmware6gk5206-2bd00-2ac26gk5853-2ea00-2da1_firmware6gk5206-2gs00-2tc2_firmware6gk5766-1ge00-7tb0_firmware6gk5213-3bf00-2ab2_firmware6ag1206-2bb00-7ac2_firmware6gk5524-8gs00-2ar26gk5788-2gd00-0ta06gk5524-8gr00-2ar26gk5528-0aa00-2hr2_firmware6gk5812-1ba00-2aa26gk5208-0ga00-2fc26gk5208-0ga00-2fc2_firmware6gk5213-3bf00-2tb26gk5216-0ba00-2ab26gk5216-0ba00-2fc2_firmware6gk5416-4gs00-2am2_firmware6gk5213-3bd00-2ab26gk5206-2gs00-2fc26gk5206-2gs00-2ac26gk5205-3bb00-2ab2_firmware6gk5208-0ba00-2fc2_firmware6gk5774-1fx00-0aa66gk5208-0ba00-2ac2_firmware6gk5206-2rs00-5fc2_firmware6gk5766-1ge00-3da06gk5826-2ab00-2ab2_firmware6gk5206-2bs00-2ac26gk5786-2hc00-0aa0_firmware6gk5528-0aa00-2hr26gk5778-1gy00-0ta0_firmware6gk5224-4gs00-2tc2_firmware6gk5788-2gy01-0aa0_firmware6gk5788-2gd00-0tc06gk5206-2bs00-2fc26gk5208-0ba00-2ac26gk5788-2fc00-0aa0_firmware6gk5748-1fc00-0aa0_firmware6gk5738-1gy00-0aa0_firmware6gk5788-2gd00-0ab06gk5786-2fc00-0aa06gk5788-2hy01-0aa06gk5208-0ha00-2as66gk5774-1fy00-0ta0_firmware6gk5721-1fc00-0ab06gk6108-4am00-2ba2_firmware6gk5205-3bd00-2tb26gk5788-1fc00-0aa06gk5524-8gr00-3ar26gk5774-1fx00-0ac0_firmware6gk5208-0ra00-5ac26gk5786-2hc00-0aa06gk5213-3bb00-2ab26gk5734-1fx00-0ab66gk5766-1ge00-7ta0_firmware6gk5216-0ha00-2ts66gk5786-2fe00-0ab06gk5816-1aa00-2aa2_firmware6gk5206-2gs00-2ac2_firmware6gk5326-2qs00-3rr36ag1216-4bs00-7ac2_firmware6gk5774-1fx00-0aa6_firmware6gk5721-1fc00-0aa0_firmware6gk5216-3rs00-2ac2_firmware6gk5204-2aa00-2gf2_firmware6gk5788-1fc00-0ab06gk5208-0ha00-2es66gk5328-4ss00-3ar3_firmware6gk5216-3rs00-5ac2_firmware6gk5788-1fc00-0ab0_firmware6gk5552-0aa00-2hr2_firmware6gk5216-4gs00-2fc26gk5876-3aa02-2ba26gk5766-1ge00-7ta06gk5788-2gd00-0tc0_firmware6gk5328-4fs00-3ar3_firmware6gk5205-3bd00-2tb2_firmware6gk5786-2fe00-0aa06gk5326-2qs00-3ar36gk5748-1gy01-0ta06gk5206-2rs00-2ac26gk5206-2bb00-2ac2_firmware6gk5213-3bb00-2ab2_firmware6gk5216-0ba00-2tb26gk5748-1fc00-0aa06gk5786-1fc00-0aa06gk5526-8gr00-4ar26gk5206-2bb00-2ac26gk5524-8gs00-4ar26gk5734-1fx00-0aa0_firmware6gk5786-2fe00-0aa0_firmware6gk5748-1gy01-0ta0_firmware6gk5876-4aa00-2ba2_firmware6ag1206-2bs00-7ac2_firmware6gk5812-1aa00-2aa26gk5524-8gs00-3ar2_firmware6gk5763-1al00-7da0_firmware6gk5524-8gr00-2ar2_firmware6gk5856-2ea00-3da1_firmware6gk5788-2gd00-0tb0_firmware6gk5416-4gr00-2am26gk5812-1aa00-2aa2_firmware6gk5788-2gd00-0aa06gk5722-1fc00-0ab06gk5528-0aa00-2ar2_firmware6gk5816-1ba00-2aa26gk5526-8gs00-2ar2_firmware6gk5778-1gy00-0aa0_firmware6gk5874-2aa00-2aa26gk5734-1fx00-0aa06gk5788-2gd00-0ab0_firmware6gk5524-8gr00-4ar26gk5524-8gs00-4ar2_firmware6gk5748-1gd00-0aa0_firmware6gk5816-1ba00-2aa2_firmware6gk5874-3aa00-2aa2_firmware6gk5804-0ap00-2aa26gk5208-0ba00-2tb2_firmware6gk5636-2gs00-2ac2_firmware6gk5528-0aa00-2ar26gk5774-1fx00-0ab0_firmware6gk5774-1fx00-0ab6_firmware6gk5206-2rs00-5ac26gk5224-4gs00-2ac26gk5328-4fs00-3rr3_firmware6gk5788-1fc00-0aa0_firmware6gk5526-8gr00-3ar26gk5816-1aa00-2aa26gk5552-0ar00-2hr26gk5408-4gp00-2am26gk5326-2qs00-3rr3_firmware6gk5328-4fs00-2ar3_firmware6gk5216-0ha00-2ts6_firmware6gk5761-1fc00-0ab0_firmware6gk5774-1fx00-0ab66gk5748-1fc00-0ab06gk5774-1fy00-0tb06gk5205-3bb00-2ab26gk5208-0ga00-2tc2_firmware6gk5876-3aa02-2ea2_firmware6gk5734-1fx00-0aa6_firmware6gk5774-1fx00-0ac06gk5204-0ba00-2yf2_firmware6gk5206-2gs00-2fc2_firmware6gk5646-2gs00-2ac26gk5856-2ea00-3aa1_firmware6gk5224-0ba00-2ac2_firmware6gk5216-0ba00-2ac2_firmware6gk5786-1fc00-0ab06gk5324-0ba00-2ar3_firmware6gk5738-1gy00-0aa06gk5763-1al00-3aa0_firmware6gk5216-4gs00-2fc2_firmware6gk5416-4gr00-2am2_firmware6gk5224-4gs00-2fc2_firmware6gk5328-4fs00-2ar36gk5213-3bf00-2tb2_firmware6gk5205-3bb00-2tb2_firmware6gk5766-1ge00-3db0_firmware6gk5526-8gs00-2ar26gk5738-1gy00-0ab06gk5324-0ba00-3ar3_firmware6gk5788-1gy01-0aa06gk5788-2fc00-0aa06gk5788-2fc00-0ac0_firmware6gk5524-8gs00-3ar26gk5326-2qs00-3ar3_firmware6gk5224-4gs00-2ac2_firmware6gk5324-0ba00-2ar36gk5208-0ga00-2tc26gk5213-3bf00-2ab26gk5552-0aa00-2ar2_firmware6gk5216-4gs00-2tc26gk5206-2rs00-5fc26gk5642-2gs00-2ac2_firmware6gk5763-1al00-3da0_firmware6gk5208-0ua00-5es6_firmware6gk5206-2gs00-2tc26gk5774-1fx00-0aa0_firmware6gk5216-0ua00-5es66gk5646-2gs00-2ac2_firmware6gk5766-1ge00-7db0_firmware6gk5788-2hy01-0aa0_firmware6gk5788-2fc00-0ac06gk5205-3bf00-2ab26gk5778-1gy00-0tb0_firmware6gk5788-2gy01-0aa06gk5552-0ar00-2ar26gk5786-2fc00-0ab0_firmware6gk5778-1gy00-0ta06gk5213-3bd00-2tb2_firmware6gk5766-1je00-3da06gk5528-0ar00-2ar2_firmware6gk5328-4fs00-2rr36gk5766-1je00-7da0_firmware6gk5622-2gs00-2ac26gk5213-3bb00-2tb26gk5204-2aa00-2yf26gk5786-2fc00-0ab06gk5208-0ba00-2ab26gk5204-2aa00-2gf26gk5738-1gy00-0ab0_firmware6gk5778-1gy00-0aa06gk5778-1gy00-0ab0_firmware6gk5216-0ba00-2fc26gk5804-0ap00-2aa2_firmware6gk5328-4ss00-3ar36gk5874-2aa00-2aa2_firmware6gk5763-1al00-7da06gk5216-3rs00-5ac26gk5208-0ba00-2tb26gk5874-3aa00-2aa26gk5721-1fc00-0aa06gk5632-2gs00-2ac26gk5328-4fs00-3rr36gk5205-3bd00-2ab26gk5778-1gy00-0ab06gk5766-1ge00-3db06gk5734-1fx00-0ab0_firmware6gk6108-4am00-2ba26gk5528-0ar00-2hr2_firmware6gk5721-1fc00-0ab0_firmware6gk5208-0ha00-2as6_firmware6gk5224-4gs00-2fc26gk5526-8gr00-2ar26gk5748-1gd00-0aa06gk5208-0ra00-2ac26gk5206-2bs00-2ac2_firmware6gk5528-0ar00-2ar26gk5761-1fc00-0aa06gk5774-1fx00-0ab06gk5205-3bf00-2tb26gk5763-1al00-3da06gk5216-0ua00-5es6_firmware6gk5632-2gs00-2ac2_firmware6gk5216-4gs00-2ac26gk5766-1je00-7ta0_firmware6gk5408-8gr00-2am2_firmware6gk5812-1ba00-2aa2_firmware6gk5722-1fc00-0ab0_firmware6gk5636-2gs00-2ac26ag1206-2bs00-7ac26gk5786-2hc00-0ab0_firmware6gk5786-1fc00-0aa0_firmware6gk5204-0ba00-2yf26gk5788-2fc00-0ab0_firmware6gk5208-0ha00-2ts66gk5642-2gs00-2ac26gk5216-0ba00-2ab2_firmware6gk5526-8gs00-3ar2_firmware6gk5408-4gp00-2am2_firmware6gk5526-8gs00-4ar2_firmware6gk5788-2gy01-0ta06gk5208-0ba00-2fc26gk5526-8gr00-3ar2_firmware6gk6108-4am00-2da26gk5408-4gq00-2am2_firmware6gk5216-0ba00-2tb2_firmware6gk5774-1fy00-0tb0_firmware6gk5786-2fe00-0ab0_firmware6gk5216-4bs00-2ac2_firmware6gk5408-8gr00-2am26gk5766-1ge00-7tb06gk5206-2bs00-2fc2_firmware6gk5216-4gs00-2ac2_firmware6gk5205-3bd00-2ab2_firmware6gk5328-4ss00-2ar36gk5208-0ha00-2es6_firmware6gk5408-8gs00-2am2_firmware6gk5205-3bf00-2ab2_firmware6gk5416-4gs00-2am26gk5766-1ge00-3da0_firmware6ag1206-2bb00-7ac26gk5208-0ra00-5ac2_firmware6gk5788-2fc00-0ab06gk5216-4gs00-2tc2_firmware6gk5766-1je00-7ta06gk5204-2aa00-2yf2_firmware6gk5526-8gs00-3ar26gk5216-0ha00-2as6_firmware6gk5748-1gy01-0aa0_firmware6gk5853-2ea00-2da16gk5788-1gd00-0ab06gk5206-2bd00-2ac2_firmware6gk5208-0ba00-2ab2_firmware6ag1208-0ba00-7ac2_firmwareSCALANCE W774-1 RJ45SCALANCE M876-4 (NAM)SCALANCE W1788-2IA M12SCALANCE XB213-3 (ST, E/IP)SCALANCE XR524-8C, 24VSCALANCE XB213-3 (ST, PN)SCALANCE XC216EECRUGGEDCOM RM1224 LTE(4G) NAMSCALANCE XB205-3 (ST, PN)SCALANCE XC208SCALANCE XB213-3LD (SC, PN)SCALANCE XC206-2G PoESCALANCE XR328-4C WG (28xGE, DC 24V)SCALANCE XB205-3LD (SC, PN)SCALANCE W734-1 RJ45 (USA)SCALANCE S615 EECSCALANCE MUM856-1 (RoW)SCALANCE XR324WG (24 X FE, DC 24V)SCALANCE XR528-6M (2HR2)SCALANCE XR528-6M (L3 int.)SCALANCE XB216 (E/IP)SCALANCE XC216-4CSCALANCE XB208 (E/IP)SCALANCE XR324WG (24 x FE, AC 230V)SCALANCE XC206-2 (SC)SCALANCE W778-1 M12 EECSCALANCE XR524-8C, 1x230VSCALANCE W788-1 M12SCALANCE M876-3 (EVDO)SCALANCE XP208SCALANCE XR552-12M (2HR2)SCALANCE XF204-2BA DNASCALANCE WAM766-1 EEC (EU)SCALANCE XB205-3LD (SC, E/IP)SCALANCE XF204-2BASCALANCE WUM763-1SIPLUS NET SCALANCE XC216-4CSCALANCE W788-2 M12 EECSCALANCE W786-2 RJ45SCALANCE XB213-3 (SC, PN)SCALANCE W1788-2 EEC M12SCALANCE XC206-2SFPSCALANCE XP216POE EECSCALANCE XM408-4C (L3 int.)SCALANCE W1788-2 M12SCALANCE W786-1 RJ45SCALANCE XP208EECSCALANCE MUM856-1 (EU)SCALANCE S615SCALANCE WAM766-1 (US)SCALANCE SC646-2CSCALANCE M826-2 SHDSL-RouterSCALANCE W786-2 SFPSCALANCE XR524-8C, 24V (L3 int.)SCALANCE XR552-12M (2HR2, L3 int.)SCALANCE XC206-2 (ST/BFOC)SCALANCE W722-1 RJ45SCALANCE XM416-4CSCALANCE W788-1 RJ45SCALANCE XR526-8C, 24V (L3 int.)SCALANCE XR528-6MSCALANCE XR528-6M (2HR2, L3 int.)SCALANCE XC216-4C GSCALANCE M874-2SCALANCE XR526-8C, 2x230VSCALANCE W1748-1 M12SCALANCE XP216 (Ethernet/IP)SCALANCE W774-1 M12 EECSCALANCE XR328-4C WG (24xFE,4xGE,AC230V)SCALANCE XC224-4C GSCALANCE XC208G PoE (54 V DC)SCALANCE M816-1 ADSL-Router (Annex B)SCALANCE XC206-2G PoE EEC (54 V DC)SCALANCE XP208 (Ethernet/IP)SCALANCE M876-3 (ROK)SCALANCE XB216 (PN)SCALANCE XC216-4C G (EIP Def.)SCALANCE M876-4SCALANCE XR526-8C, 24VSCALANCE W734-1 RJ45SCALANCE SC636-2CSCALANCE W788-2 RJ45SCALANCE XM408-4CSCALANCE XC208G PoESCALANCE XR524-8C, 1x230V (L3 int.)SCALANCE WUM766-1 (US)SCALANCE W778-1 M12SCALANCE W748-1 RJ45SCALANCE XM408-8C (L3 int.)SCALANCE XB213-3LD (SC, E/IP)SCALANCE XC216SCALANCE XC208G EECSCALANCE XC208G (EIP def.)SCALANCE XC208GSCALANCE XR526-8C, 2x230V (L3 int.)SCALANCE XP216EECSCALANCE M816-1 ADSL-Router (Annex A)SCALANCE XC206-2G PoE (54 V DC)SCALANCE XM416-4C (L3 int.)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE XC206-2SFP GSCALANCE W774-1 RJ45 (USA)SCALANCE MUM853-1 (EU)SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)SCALANCE W778-1 M12 EEC (USA)SCALANCE W1788-1 M12SCALANCE W738-1 M12SCALANCE M876-4 (EU)SCALANCE XR524-8C, 2x230VSCALANCE XR526-8C, 1x230V (L3 int.)SCALANCE M804PBSCALANCE XC216-3G PoE (54 V DC)SCALANCE XR326-2C PoE WG (without UL)SCALANCE XB205-3 (SC, PN)SCALANCE XC206-2SFP EECSCALANCE W721-1 RJ45SCALANCE XC206-2SFP G (EIP DEF.)SCALANCE WAM766-1 (EU)SCALANCE M812-1 ADSL-Router (Annex B)SCALANCE SC632-2CSCALANCE XP208PoE EECSCALANCE W786-2IA RJ45SCALANCE XF204SCALANCE XF204 DNASCALANCE M812-1 ADSL-Router (Annex A)SCALANCE XB213-3 (SC, E/IP)SCALANCE XR524-8C, 2x230V (L3 int.)SCALANCE XB208 (PN)SCALANCE XC224SCALANCE XR326-2C PoE WGSCALANCE M874-3SCALANCE WUM766-1 (EU)SCALANCE XB205-3 (ST, E/IP)SCALANCE XC208EECSCALANCE WAM763-1SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)SIPLUS NET SCALANCE XC206-2SCALANCE XM408-8CSCALANCE W748-1 M12SCALANCE SC642-2CSCALANCE XR552-12MSCALANCE XR526-8C, 1x230VSCALANCE XR328-4C WG (28xGE, AC 230V)SIPLUS NET SCALANCE XC208SCALANCE XC206-2SFP G EECSCALANCE XC224-4C G EECSCALANCE WAM766-1 EEC (US)SCALANCE W761-1 RJ45SCALANCE XC216-3G PoESCALANCE XC216-4C G EECSIPLUS NET SCALANCE XC206-2SFPSCALANCE XP216SCALANCE XC224-4C G (EIP Def.)SCALANCE SC622-2CSCALANCE W788-2 M12
CWE ID-CWE-862
Missing Authorization
CVE-2022-29872
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.29% / 78.86%
||
7 Day CHG~0.00%
Published-10 May, 2022 | 09:47
Updated-03 Aug, 2024 | 06:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices do not properly validate parameters of POST requests. This could allow an authenticated attacker to set the device to a denial of service state or to control the program counter and, thus, execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-7kg8501-0aa11-2aa0_firmware7kg8551-0aa01-2aa07kg8501-0aa11-0aa07kg8500-0aa10-0aa0_firmware7kg8501-0aa31-2aa0_firmware7kg8551-0aa02-2aa0_firmware7kg8551-0aa02-0aa0_firmware7kg8551-0aa32-2aa0_firmware7kg8550-0aa00-0aa07kg8550-0aa00-0aa0_firmware7kg8501-0aa01-0aa07kg8551-0aa02-0aa07kg8500-0aa30-0aa07kg8551-0aa32-0aa0_firmware7kg8551-0aa02-2aa07kg8550-0aa30-0aa0_firmware7kg8501-0aa32-0aa07kg8500-0aa30-2aa0_firmware7kg8501-0aa01-0aa0_firmware7kg8501-0aa02-0aa07kg8551-0aa12-2aa07kg8500-0aa00-0aa07kg8551-0aa01-0aa0_firmware7kg8501-0aa11-2aa07kg8501-0aa31-0aa07kg8501-0aa12-2aa0_firmware7kg8501-0aa32-2aa07kg8550-0aa00-2aa0_firmware7kg8550-0aa30-2aa07kg8501-0aa31-0aa0_firmware7kg8550-0aa30-0aa07kg8501-0aa12-0aa0_firmware7kg8551-0aa12-0aa07kg8500-0aa30-2aa07kg8501-0aa32-2aa0_firmware7kg8500-0aa10-2aa0_firmware7kg8500-0aa00-2aa0_firmware7kg8501-0aa01-2aa0_firmware7kg8501-0aa02-0aa0_firmware7kg8500-0aa10-0aa07kg8551-0aa12-0aa0_firmware7kg8550-0aa30-2aa0_firmware7kg8551-0aa32-2aa07kg8501-0aa11-0aa0_firmware7kg8550-0aa10-2aa07kg8501-0aa02-2aa0_firmware7kg8551-0aa32-0aa07kg8501-0aa32-0aa0_firmware7kg8551-0aa12-2aa0_firmware7kg8550-0aa10-0aa0_firmware7kg8501-0aa01-2aa07kg8550-0aa00-2aa07kg8551-0aa31-2aa0_firmware7kg8551-0aa11-2aa07kg8501-0aa12-0aa07kg8551-0aa31-0aa0_firmware7kg8551-0aa11-0aa07kg8500-0aa00-2aa07kg8551-0aa01-2aa0_firmware7kg8550-0aa10-2aa0_firmware7kg8550-0aa10-0aa07kg8551-0aa31-0aa07kg8551-0aa11-0aa0_firmware7kg8551-0aa11-2aa0_firmware7kg8500-0aa30-0aa0_firmware7kg8551-0aa01-0aa07kg8501-0aa02-2aa07kg8500-0aa10-2aa07kg8551-0aa31-2aa07kg8501-0aa31-2aa07kg8501-0aa12-2aa07kg8500-0aa00-0aa0_firmwareSICAM P850SICAM P855
CWE ID-CWE-141
Improper Neutralization of Parameter/Argument Delimiters
CWE ID-CWE-20
Improper Input Validation
CVE-2020-9273
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-46.79% / 97.59%
||
7 Day CHG~0.00%
Published-20 Feb, 2020 | 15:22
Updated-04 Aug, 2024 | 10:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In ProFTPD 1.3.7, it is possible to corrupt the memory pool by interrupting the data transfer channel. This triggers a use-after-free in alloc_pool in pool.c, and possible remote code execution.

Action-Not Available
Vendor-proftpdn/aDebian GNU/LinuxSiemens AGopenSUSEFedora Project
Product-simatic_net_cp_1543-1debian_linuxsimatic_net_cp_1543-1_firmwaresimatic_net_cp_1545-1fedoraproftpdsimatic_net_cp_1545-1_firmwarebackports_sleleapn/a
CWE ID-CWE-416
Use After Free
CVE-2022-25753
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-4.64% / 88.87%
||
7 Day CHG~0.00%
Published-12 Apr, 2022 | 09:07
Updated-03 Aug, 2024 | 04:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The handling of arguments such as IP addresses in the CLI of affected devices is prone to buffer overflows. This could allow an authenticated remote attacker to execute arbitrary code on the device.

Action-Not Available
Vendor-Siemens AG
Product-scalance_x308-2m_ts_firmwarescalance_x307-3_firmwarescalance_xr324-12mscalance_x310fescalance_x310fe_firmwarescalance_xr324-4m_eecscalance_x308-2ldscalance_x320-1fe_firmwaresiplus_net_scalance_x308-2scalance_xr324-4m_poe_firmwarescalance_x308-2scalance_x307-2eecscalance_xr324-4m_eec_firmwarescalance_x308-2_firmwarescalance_x304-2fe_firmwarescalance_xr324-12m_ts_firmwarescalance_x306-1ldfe_firmwarescalance_x307-2eec_firmwarescalance_x320-1-2ldfesiplus_net_scalance_x308-2_firmwarescalance_x308-2lh_firmwarescalance_x302-7eec_firmwarescalance_x308-2lhscalance_x307-3ld_firmwarescalance_x310scalance_x320-1-2ldfe_firmwarescalance_xr324-12m_firmwarescalance_x308-2m_poe_firmwarescalance_x310_firmwarescalance_x308-2m_poescalance_x308-2lh\+_firmwarescalance_x308-2ld_firmwarescalance_xr324-12m_tsscalance_x308-2m_tsscalance_x308-2m_firmwarescalance_x320-1fescalance_x408-2scalance_xr324-4m_poescalance_x306-1ldfescalance_x307-3ldscalance_x308-2mscalance_x408-2_firmwarescalance_x307-3scalance_x304-2fescalance_xr324-4m_poe_tsscalance_xr324-4m_poe_ts_firmwarescalance_x302-7eecscalance_x308-2lh\+SCALANCE XR324-12M TS (24V)SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-4M PoE (24V, ports on rear)SCALANCE XR324-4M EEC (24V, ports on front)SCALANCE XR324-12M (230V, ports on rear)SCALANCE X307-2 EEC (2x 24V, coated)SCALANCE XR324-4M PoE TS (24V, ports on front)SCALANCE X307-3SCALANCE X308-2MSCALANCE XR324-12M (24V, ports on rear)SCALANCE X308-2SCALANCE X308-2M PoESCALANCE X310FESCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)SCALANCE X308-2LH+SCALANCE X302-7 EEC (24V, coated)SCALANCE X307-2 EEC (230V, coated)SCALANCE X307-3LDSCALANCE X308-2LHSCALANCE XR324-4M EEC (24V, ports on rear)SCALANCE XR324-4M PoE (24V, ports on front)SCALANCE X302-7 EEC (2x 230V)SCALANCE X408-2SIPLUS NET SCALANCE X308-2SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)SCALANCE XR324-4M PoE (230V, ports on rear)SCALANCE X302-7 EEC (230V)SCALANCE X307-2 EEC (24V, coated)SCALANCE X307-2 EEC (2x 230V, coated)SCALANCE X302-7 EEC (2x 24V, coated)SCALANCE X308-2LDSCALANCE X307-2 EEC (24V)SCALANCE X304-2FESCALANCE X310SCALANCE X307-2 EEC (2x 24V)SCALANCE X307-2 EEC (230V)SCALANCE XR324-12M (24V, ports on front)SCALANCE X320-1 FESCALANCE X302-7 EEC (2x 24V)SCALANCE X306-1LD FESCALANCE X308-2M TSSCALANCE XR324-4M PoE (230V, ports on front)SCALANCE X307-2 EEC (2x 230V)SCALANCE X302-7 EEC (24V)SCALANCE X302-7 EEC (230V, coated)SCALANCE X302-7 EEC (2x 230V, coated)SCALANCE X320-1-2LD FESCALANCE XR324-4M EEC (2x 24V, ports on rear)SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)SCALANCE XR324-12M (230V, ports on front)SCALANCE XR324-4M EEC (2x 24V, ports on front)
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2020-7591
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.27% / 50.02%
||
7 Day CHG~0.00%
Published-15 Oct, 2020 | 18:45
Updated-04 Aug, 2024 | 09:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIPORT MP (All versions < 3.2.1). Vulnerable versions of the device could allow an authenticated attacker to impersonate other users of the system and perform (potentially administrative) actions on behalf of those users if the single sign-on feature ("Allow logon without password") is enabled.

Action-Not Available
Vendor-Siemens AG
Product-siport_mpSIPORT MP
CWE ID-CWE-603
Use of Client-Side Authentication
CWE ID-CWE-287
Improper Authentication
CVE-2023-49251
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.64%
||
7 Day CHG~0.00%
Published-09 Jan, 2024 | 10:00
Updated-14 Nov, 2024 | 15:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.7). The "intermediate installation" system state of the affected application allows an attacker to add their own login credentials to the device. This allows an attacker to remotely login as root and take control of the device even after the affected device is fully set up.

Action-Not Available
Vendor-Siemens AG
Product-simatic_cn_4100SIMATIC CN 4100
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2022-25311
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.19% / 41.00%
||
7 Day CHG~0.00%
Published-08 Mar, 2022 | 00:00
Updated-21 Apr, 2025 | 13:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation.

Action-Not Available
Vendor-Siemens AG
Product-sinema_serversinec_network_management_systemSINEC NMSSINEMA Server V14
CWE ID-CWE-269
Improper Privilege Management
CVE-2017-6458
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-5.22% / 89.57%
||
7 Day CHG~0.00%
Published-27 Mar, 2017 | 17:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple buffer overflows in the ctl_put* functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable.

Action-Not Available
Vendor-ntpn/aApple Inc.Siemens AGHewlett Packard Enterprise (HPE)
Product-mac_os_xhpux-ntpntpsimatic_net_cp_443-1_opc_uasimatic_net_cp_443-1_opc_ua_firmwaren/a
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CVE-2021-45960
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-0.37% / 58.27%
||
7 Day CHG-0.01%
Published-01 Jan, 2022 | 18:47
Updated-05 May, 2025 | 17:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Expat (aka libexpat) before 2.4.3, a left shift by 29 (or more) places in the storeAtts function in xmlparse.c can lead to realloc misbehavior (e.g., allocating too few bytes, or only freeing memory).

Action-Not Available
Vendor-libexpat_projectn/aSiemens AGTenable, Inc.NetApp, Inc.Debian GNU/Linux
Product-nessusactive_iq_unified_managerdebian_linuxsolidfire_\&_hci_management_nodelibexpatsinema_remote_connect_serveroncommand_workflow_automationhci_baseboard_management_controllern/a
CWE ID-CWE-682
Incorrect Calculation
CVE-2021-45033
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.28% / 51.25%
||
7 Day CHG~0.00%
Published-11 Jan, 2022 | 11:27
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.

Action-Not Available
Vendor-Siemens AG
Product-cp-8000_master_module_with_i\/o_-25\/\+70cp-8000_master_module_with_i\/o_-25\/\+70_firmwarecp-8000_master_module_with_i\/o_-40\/\+70_firmwarecp-8022_master_module_with_gprs_firmwarecp-8021_master_modulecp-8022_master_module_with_gprscp-8000_master_module_with_i\/o_-40\/\+70cp-8021_master_module_firmwareCP-8022 MASTER MODULE WITH GPRSCP-8021 MASTER MODULECP-8000 MASTER MODULE WITH I/O -25/+70°CCP-8000 MASTER MODULE WITH I/O -40/+70°C
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2023-40731
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-5.7||MEDIUM
EPSS-0.16% / 37.01%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application allows users to upload arbitrary file types. This could allow an attacker to upload malicious files, that could potentially lead to code tampering.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2020-25240
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.79%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). Unpriviledged users can access services when guessing the url. An attacker could impact availability, integrity and gain information from logs and templates of the service.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2020-25239
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.34% / 55.79%
||
7 Day CHG~0.00%
Published-15 Mar, 2021 | 17:03
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0). The webserver could allow unauthorized actions via special urls for unpriviledged users. The settings of the UMC authorization server could be changed to add a rogue server by an attacker authenticating with unprivilege user rights.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-44374
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.19% / 40.76%
||
7 Day CHG~0.00%
Published-14 Nov, 2023 | 11:04
Updated-14 Jan, 2025 | 11:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges.

Action-Not Available
Vendor-Siemens AG
Product-6gk5216-0ha00-2as6_firmware6gk5213-3bf00-2ab26gk5216-0ba00-2tb26gk5204-2aa00-2gf26gk5205-3bd00-2ab2_firmware6gk5213-3bd00-2ab2_firmware6gk5206-2rs00-2ac2_firmware6gk5224-4gs00-2fc26gk5328-4fs00-3ar36gk5213-3bd00-2tb26gk5206-2bs00-2fc26gk5205-3bb00-2ab26gk5206-2rs00-2ac26gk5206-2bs00-2fc2_firmware6gk5328-4fs00-2rr36gk5208-0ba00-2tb26gk5208-0ha00-2as6_firmware6gk5208-0ha00-2ts6_firmware6gk5205-3bb00-2ab2_firmware6gk5216-0ba00-2fc2_firmware6gk5224-4gs00-2tc26gk5206-2bb00-2ac26gk5206-2gs00-2tc26gk5326-2qs00-3ar3_firmware6gk5213-3bf00-2tb2_firmware6gk5216-3rs00-5ac2_firmware6gk5216-0ua00-5es66gk5206-2bd00-2ac26gk5216-4gs00-2tc2_firmware6gk5328-4ss00-2ar36gk5216-4bs00-2ac26gk5208-0ha00-2as66gk5213-3bb00-2ab26gk5213-3bb00-2ab2_firmware6gk5208-0ba00-2ac26gk5216-4bs00-2ac2_firmware6gk5208-0ba00-2fc26gk5216-0ba00-2ac2_firmware6gk5328-4fs00-3ar3_firmware6gk5204-0ba00-2gf2_firmware6gk5208-0ra00-5ac26gk5216-0ha00-2es66gk5216-0ha00-2es6_firmware6gk5224-4gs00-2tc2_firmware6gk5216-0ba00-2fc26gk5216-0ua00-5es6_firmware6gk5213-3bd00-2ab26ag1208-0ba00-7ac2_firmware6ag1206-2bs00-7ac26gk5208-0ra00-2ac2_firmware6gk5216-4gs00-2tc26ag1206-2bs00-7ac2_firmware6gk5224-4gs00-2fc2_firmware6gk5324-0ba00-2ar3_firmware6gk5206-2gs00-2ac26gk5208-0ha00-2ts66gk5326-2qs00-3ar36ag1206-2bb00-7ac2_firmware6ag1216-4bs00-7ac26gk5208-0ba00-2ab2_firmware6gk5206-2bd00-2ac2_firmware6gk5204-0ba00-2yf2_firmware6gk5206-2bs00-2ac26gk5328-4ss00-3ar36gk5208-0ga00-2tc2_firmware6gk5208-0ba00-2fc2_firmware6gk5205-3bf00-2tb26gk5206-2rs00-5ac26gk5205-3bd00-2tb26gk5328-4ss00-3ar3_firmware6gk5224-4gs00-2ac2_firmware6gk5324-0ba00-3ar3_firmware6gk5328-4fs00-3rr36gk5216-0ba00-2ab2_firmware6gk5328-4ss00-2ar3_firmware6gk5205-3bb00-2tb2_firmware6gk5216-0ba00-2ab26gk5216-4gs00-2fc26gk5213-3bd00-2tb2_firmware6gk5216-4gs00-2ac26gk5216-3rs00-5ac26gk5216-3rs00-2ac26gk5208-0ga00-2ac2_firmware6gk5205-3bf00-2ab26gk5208-0ga00-2ac26gk5224-4gs00-2ac26gk5206-2gs00-2tc2_firmware6gk5206-2gs00-2ac2_firmware6gk5208-0ga00-2fc2_firmware6gk5206-2rs00-5fc26gk5208-0ba00-2ac2_firmware6gk5326-2qs00-3rr36gk5328-4fs00-2ar3_firmware6gk5326-2qs00-3rr3_firmware6gk5208-0ra00-5ac2_firmware6gk5204-2aa00-2yf2_firmware6gk5204-2aa00-2yf26gk5216-0ha00-2ts66gk5205-3bf00-2ab2_firmware6gk5216-4gs00-2ac2_firmware6gk5206-2rs00-5ac2_firmware6gk5216-3rs00-2ac2_firmware6gk5208-0ba00-2tb2_firmware6gk5216-0ha00-2as66gk5204-0ba00-2yf26gk5208-0ua00-5es6_firmware6gk5204-2aa00-2gf2_firmware6gk5208-0ua00-5es66gk5213-3bb00-2tb26gk5216-0ba00-2tb2_firmware6gk5206-2bs00-2ac2_firmware6gk5208-0ga00-2tc26gk5206-2gs00-2fc2_firmware6gk5204-0ba00-2gf26gk5206-2bb00-2ac2_firmware6ag1206-2bb00-7ac26gk5213-3bb00-2tb2_firmware6gk5208-0ha00-2es66gk5205-3bf00-2tb2_firmware6gk5206-2rs00-5fc2_firmware6gk5216-4gs00-2fc2_firmware6gk5324-0ba00-3ar36gk5205-3bd00-2tb2_firmware6gk5328-4fs00-2ar36gk5216-0ba00-2ac26gk5206-2gs00-2fc26ag1208-0ba00-7ac26gk5328-4fs00-2rr3_firmware6ag1216-4bs00-7ac2_firmware6gk5224-0ba00-2ac2_firmware6gk5208-0ga00-2fc26gk5213-3bf00-2ab2_firmware6gk5208-0ra00-2ac26gk5328-4fs00-3rr3_firmware6gk5208-0ba00-2ab26gk5205-3bd00-2ab26gk5324-0ba00-2ar36gk5216-0ha00-2ts6_firmware6gk5213-3bf00-2tb26gk5224-0ba00-2ac26gk5208-0ha00-2es6_firmware6gk5205-3bb00-2tb2SCALANCE S615 LAN-RouterSCALANCE WAM766-1 (ME)SCALANCE WAM766-1SCALANCE WUM766-1SCALANCE WUB762-1 iFeaturesSCALANCE M812-1 ADSL-RouterSCALANCE WUM766-1 (ME)SCALANCE M816-1 ADSL-RouterSCALANCE M876-4 (EU)SCALANCE WUB762-1RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M874-2SCALANCE WAM763-1SCALANCE M804PBSCALANCE WAM766-1 EEC (ME)SCALANCE WAM766-1 EECSCALANCE WUM763-1 (US)SCALANCE WAM766-1 EEC (US)SCALANCE WUM763-1SCALANCE WUM766-1 (USA)SCALANCE WAM763-1 (US)SCALANCE MUM853-1 (EU)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (RoW)SCALANCE M876-4SCALANCE WAB762-1SCALANCE M876-3 (ROK)SCALANCE WAM763-1 (ME)SCALANCE MUM856-1 (EU)SCALANCE WAM766-1 (US)SCALANCE M874-3SCALANCE S615 EEC LAN-RouterSCALANCE M876-4 (NAM)
CWE ID-CWE-567
Unsynchronized Access to Shared Data in a Multithreaded Context
CVE-2023-42796
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.29% / 51.75%
||
7 Day CHG~0.00%
Published-10 Oct, 2023 | 10:21
Updated-27 Feb, 2025 | 20:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.11), CP-8050 MASTER MODULE (All versions < CPCI85 V05.11). The web server of affected devices fails to properly sanitize user input for the /sicweb-ajax/tmproot/ endpoint. This could allow an authenticated remote attacker to traverse directories on the system and download arbitrary files. By exploring active session IDs, the vulnerability could potentially be leveraged to escalate privileges to the administrator role.

Action-Not Available
Vendor-Siemens AG
Product-cp-8050_firmwarecp-8050cp-8031_firmwarecp-8031CP-8031 MASTER MODULECP-8050 MASTER MODULE
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-4845
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.43% / 61.81%
||
7 Day CHG~0.00%
Published-26 Jun, 2018 | 18:00
Updated-16 Sep, 2024 | 18:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.

Action-Not Available
Vendor-Siemens AG
Product-rapidlab_1200_firmwarerapidpoint_500_firmwarerapidpoint_500rapidpoint_400_firmwarerapidlab_1200rapidpoint_400RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems, RAPIDLab 1200 Series, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 500 systems, RAPIDPoint 400 systems
CWE ID-CWE-284
Improper Access Control
CWE ID-CWE-269
Improper Privilege Management
CVE-2021-40355
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.40% / 59.54%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.

Action-Not Available
Vendor-Siemens AG
Product-teamcenter_visualizationTeamcenter V12.4Teamcenter V13.0Teamcenter V13.2Teamcenter V13.1
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2021-40360
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.31% / 53.93%
||
7 Day CHG~0.00%
Published-09 Feb, 2022 | 15:17
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CWE ID-CWE-522
Insufficiently Protected Credentials
CVE-2023-40726
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.14% / 34.78%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The affected application server responds with sensitive information about the server. This could allow an attacker to directly access the database.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-550
Server-generated Error Message Containing Sensitive Information
CVE-2019-6570
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-0.24% / 47.25%
||
7 Day CHG~0.00%
Published-17 Apr, 2019 | 13:40
Updated-04 Aug, 2024 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Due to insufficient checking of user permissions, an attacker may access URLs that require special authorization. An attacker must have access to a low privileged account in order to exploit the vulnerability.

Action-Not Available
Vendor-Siemens AG
Product-sinema_remote_connect_serverSINEMA Remote Connect Server
CWE ID-CWE-280
Improper Handling of Insufficient Permissions or Privileges
CWE ID-CWE-863
Incorrect Authorization
CVE-2023-40730
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.1||HIGH
EPSS-0.12% / 32.36%
||
7 Day CHG~0.00%
Published-12 Sep, 2023 | 09:32
Updated-27 Feb, 2025 | 20:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application lacks sufficient authorization checks. This could allow an attacker to access confidential information, perform administrative functions, or lead to a denial-of-service condition.

Action-Not Available
Vendor-Siemens AG
Product-qms_automotiveQMS Automotive
CWE ID-CWE-284
Improper Access Control
CVE-2023-28829
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-3.9||LOW
EPSS-0.07% / 22.60%
||
7 Day CHG~0.00%
Published-13 Jun, 2023 | 08:17
Updated-03 Jan, 2025 | 01:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.

Action-Not Available
Vendor-Siemens AG
Product-simatic_net_pc_softwaresinaut_st7scsimatic_pcs_7simatic_winccSIMATIC NET PC Software V14SIMATIC NET PC Software V15SIMATIC WinCCSIMATIC PCS 7 V9.0SINAUT Software ST7scSIMATIC PCS 7 V9.1SIMATIC PCS 7 V8.2
CWE ID-CWE-477
Use of Obsolete Function
CVE-2023-30899
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-1.99% / 82.86%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 17:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video 2020 R2 (All versions < V20.2 HotfixRev14), Siveillance Video 2020 R3 (All versions < V20.3 HotfixRev12), Siveillance Video 2021 R1 (All versions < V21.1 HotfixRev12), Siveillance Video 2021 R2 (All versions < V21.2 HotfixRev8), Siveillance Video 2022 R1 (All versions < V22.1 HotfixRev7), Siveillance Video 2022 R2 (All versions < V22.2 HotfixRev5), Siveillance Video 2022 R3 (All versions < V22.3 HotfixRev2), Siveillance Video 2023 R1 (All versions < V23.1 HotfixRev1). The Management Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_videoSiveillance Video 2022 R1Siveillance Video 2022 R3Siveillance Video 2021 R2Siveillance Video 2023 R1Siveillance Video 2021 R1Siveillance Video 2022 R2Siveillance Video 2020 R2Siveillance Video 2020 R3
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2023-30898
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-1.99% / 82.86%
||
7 Day CHG~0.00%
Published-09 May, 2023 | 11:51
Updated-28 Jan, 2025 | 18:34
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siveillance Video 2020 R2 (All versions < V20.2 HotfixRev14), Siveillance Video 2020 R3 (All versions < V20.3 HotfixRev12), Siveillance Video 2021 R1 (All versions < V21.1 HotfixRev12), Siveillance Video 2021 R2 (All versions < V21.2 HotfixRev8), Siveillance Video 2022 R1 (All versions < V22.1 HotfixRev7), Siveillance Video 2022 R2 (All versions < V22.2 HotfixRev5), Siveillance Video 2022 R3 (All versions < V22.3 HotfixRev2), Siveillance Video 2023 R1 (All versions < V23.1 HotfixRev1). The Event Server component of affected applications deserializes data without sufficient validations. This could allow an authenticated remote attacker to execute code on the affected system.

Action-Not Available
Vendor-Siemens AG
Product-siveillance_videoSiveillance Video 2022 R1Siveillance Video 2022 R3Siveillance Video 2021 R2Siveillance Video 2023 R1Siveillance Video 2021 R1Siveillance Video 2022 R2Siveillance Video 2020 R2Siveillance Video 2020 R3
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2021-37173
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-8.8||HIGH
EPSS-1.55% / 80.69%
||
7 Day CHG~0.00%
Published-14 Sep, 2021 | 10:47
Updated-04 Aug, 2024 | 01:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.14.1), RUGGEDCOM ROX RX1400 (All versions < V2.14.1), RUGGEDCOM ROX RX1500 (All versions < V2.14.1), RUGGEDCOM ROX RX1501 (All versions < V2.14.1), RUGGEDCOM ROX RX1510 (All versions < V2.14.1), RUGGEDCOM ROX RX1511 (All versions < V2.14.1), RUGGEDCOM ROX RX1512 (All versions < V2.14.1), RUGGEDCOM ROX RX1524 (All versions < V2.14.1), RUGGEDCOM ROX RX1536 (All versions < V2.14.1), RUGGEDCOM ROX RX5000 (All versions < V2.14.1). The command line interface of affected devices insufficiently restrict file read and write operations for low privileged users. This could allow an authenticated remote attacker to escalate privileges and gain root access to the device.

Action-Not Available
Vendor-Siemens AG
Product-ruggedcom_rox_rx1511ruggedcom_rox_rx1512ruggedcom_rox_mx5000_firmwareruggedcom_rox_rx5000_firmwareruggedcom_rox_rx1511_firmwareruggedcom_rox_rx1510ruggedcom_rox_rx1400_firmwareruggedcom_rox_rx1500_firmwareruggedcom_rox_rx1400ruggedcom_rox_rx1510_firmwareruggedcom_rox_rx1500ruggedcom_rox_rx1524_firmwareruggedcom_rox_rx5000ruggedcom_rox_rx1501ruggedcom_rox_rx1536ruggedcom_rox_mx5000ruggedcom_rox_rx1524ruggedcom_rox_rx1536_firmwareruggedcom_rox_rx1501_firmwareruggedcom_rox_rx1512_firmwareRUGGEDCOM ROX RX1511RUGGEDCOM ROX RX1536RUGGEDCOM ROX RX1400RUGGEDCOM ROX RX1500RUGGEDCOM ROX RX1501RUGGEDCOM ROX RX5000RUGGEDCOM ROX MX5000RUGGEDCOM ROX RX1524RUGGEDCOM ROX RX1510RUGGEDCOM ROX RX1512
CWE ID-CWE-269
Improper Privilege Management
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 38
  • 39
  • Next
Details not found