Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level access to the device, such as allowing any attacker to access the Setting Center. This means that this is effectively backdoor for all devices utilizing a Growatt ShineLan-X communication dongle.
The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access to the device and to extracting secrets or domains from within the device
Due to lack of server-side input validation, attackers can inject malicious JavaScript code into users personal spaces of the web portal.
Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint.
An attacker can upload an arbitrary file instead of a plant image.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 does not defend against physical access to U-Boot via the UART: the Wi-Fi password is shown, and the hardcoded boot password can be inserted for console access.
An issue was discovered in the box application on HiSilicon based IPTV/H.264/H.265 video encoders. Attackers can use hard-coded credentials in HTTP requests to perform any administrative task on the device including retrieving the device's configuration (with the cleartext admin password), and uploading a custom firmware update, to ultimately achieve arbitrary code execution.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
An issue in SCHUHFRIED v.8.22.00 allows remote attacker to obtain the database password via crafted curl command.
ASUS WebStorage has a hardcoded API Token in the APP source code. An unauthenticated remote attacker can use this token to establish connections with the server and carry out login attempts to general user accounts. A successful login to a general user account allows the attacker to access, modify or delete this user account information.
A use of hard-coded cryptographic key in Fortinet FortiSwitch version 7.4.0 and 7.2.0 through 7.2.5 and 7.0.0 through 7.0.7 and 6.4.0 through 6.4.13 and 6.2.0 through 6.2.7 and 6.0.0 through 6.0.7 allows attacker to execute unauthorized code or commands via crafted requests.
NUUO v03.11.00 was discovered to contain access control issue.
The express install, which is the suggested way to install Puppet Enterprise, gives the user a URL at the end of the install to set the admin password. If they do not use that URL, there is an overlooked default password for the admin user. This was resolved in Puppet Enterprise 2019.0.3 and 2018.1.9.
Bettini Srl GAMS Product Line v4.3.0 was discovered to re-use static SSH keys across installations, allowing unauthenticated attackers to login as root users via extracting a key from the software.
In SapphireIMS 5.0, it is possible to use the hardcoded credential in clients (username: sapphire, password: ims) and gain access to the portal. Once the access is available, the attacker can inject malicious OS commands on “ping”, “traceroute” and “snmp” functions and execute code on the server. We also observed the same is true if the JSESSIONID is completely removed.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
The Atlassian Questions For Confluence app for Confluence Server and Data Center creates a Confluence user account in the confluence-users group with the username disabledsystemuser and a hardcoded password. A remote, unauthenticated attacker with knowledge of the hardcoded password could exploit this to log into Confluence and access all content accessible to users in the confluence-users group. This user account is created when installing versions 2.7.34, 2.7.35, and 3.0.2 of the app.
Home Owners Collection Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
Trend Micro ServerProtect 6.0/5.8 Information Server uses a static credential to perform authentication when a specific command is typed in the console. An unauthenticated remote attacker with access to the Information Server could exploit this to register to the server and perform authenticated actions.
Baicells Nova436Q and Neutrino 430 devices with firmware through QRTB 2.7.8 have hardcoded credentials that are easily discovered, and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
Goldshell ASIC Miners v2.1.x was discovered to contain hardcoded credentials which allow attackers to remotely connect via the SSH protocol (port 22).
Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
QXIP SIPCAPTURE homer-app before 1.4.28 for HOMER 7.x has the same 167f0db2-f83e-4baa-9736-d56064a5b415 JWT secret key across different customers' installations.
In ScadaBR version 1.2.0, a Use of Hard-Coded Credentials vulnerability could allow an attacker to access the SCADA system as admin.
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
The Le-yan dental management system contains a hard-coded credentials vulnerability in the web page source code, which allows an unauthenticated remote attacker to acquire administrator’s privilege and control the system or disrupt service.
Hard-coded credentials in Web-UI of multiple VARTA Storage products in multiple versions allows an unauthorized attacker to gain administrative access to the Web-UI via network.
A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain full access to the device.
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
Taiko AG1000-01A SMS Alert Gateway Rev 7.3 and Rev 8 contains a hard-coded credential vulnerability in the embedded web configuration interface where authentication is implemented entirely in client-side JavaScript in login.zhtml, exposing static plaintext credentials in the page source. Unauthenticated attackers with network access can recover administrative credentials directly from the client-side validate() function to obtain full administrative access to the device.
The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number.
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
Yarbo firmware v2.3.9 contains hardcoded administrative credentials embedded in the firmware image. These credentials are identical across all devices running this firmware and cannot be changed or removed by end users, enabling trivial unauthorized access to device management interfaces by anyone who knows them.
Use of Hard-coded Cryptographic Key vulnerability in the WebReportsApi.dll of Exago Web Reports, as used in the Device42 Asset Management Appliance, allows an attacker to leak session IDs and elevate privileges. This issue affects: Device42 CMDB versions prior to 18.01.00.
A hardcoded password was set for accounts registered using an OmniAuth provider (e.g. OAuth, LDAP, SAML) in GitLab CE/EE versions 14.7 prior to 14.7.7, 14.8 prior to 14.8.5, and 14.9 prior to 14.9.2 allowing attackers to potentially take over accounts
Certain NETGEAR devices are affected by a hardcoded password. This affects D3600 before 1.0.0.76 and D6000 before 1.0.0.76.
D-Link COVR-2600R and COVR-3902 Kit before 1.01b05Beta01 use hardcoded credentials for telnet connection, which allows unauthenticated attackers to gain privileged access to the router, and to extract sensitive data or modify the configuration.
Denver SHC-150 Smart Wifi Camera contains a hardcoded telnet credential vulnerability that allows unauthenticated attackers to access a Linux shell. Attackers can connect to port 23 using the default credential to execute arbitrary commands on the camera's operating system.
Shenzen Tenda Technology IP Camera CP3 V11.10.00.2211041355 was discovered to contain a hard-coded default password for the RTSP feed.
dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials.
Hardcoded manufacturer credentials and an OS command injection vulnerability in the /cgi-bin/mft/ directory on ABUS TVIP TVIP20050 LM.1.6.18, TVIP10051 LM.1.6.18, TVIP11050 MG.1.6.03.05, TVIP20550 LM.1.6.18, TVIP10050 LM.1.6.18, TVIP11550 MG.1.6.03, TVIP21050 MG.1.6.03, and TVIP51550 MG.1.6.03 cameras allow remote attackers to execute code as root.
Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by hard coded credentials. A hardcoded credential exist in /etc/tomcat8/tomcat-user.xml, which allows attackers to gain authorized access and control the tomcat completely on port 8000 in the tomcat manger page.
An issue was discovered on FiberHome HG6245D devices through RP2613. There is a 6GFJdY4aAuUKJjdtSn7d password for the rdsadmin account.
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
An issue was discovered in Kaseya Unitrends Backup Appliance before 10.5.5. The SNMP daemon was configured with a weak default community.