A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.
A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
ProFTPD 1.3.7 has an out-of-bounds (OOB) read vulnerability in mod_cap via the cap_text.c cap_to_text function.
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260)
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted XDB files. This could allow an attacker to execute code in the context of the current process.
Drawings SDK (All versions prior to 2022.4) are vulnerable to an out-of-bounds read due to parsing of DWG files resulting from the lack of proper validation of user-supplied data. This can result in a read past the end of an allocated buffer and allows attackers to cause a denial-of service condition or read sensitive information from memory.
The Quagga BGP daemon (bgpd) prior to version 1.2.3 can overrun internal BGP code-to-string conversion tables used for debug by 1 pointer value, based on input.
A vulnerability has been identified in JT2Go (All versions < V14.2.0.5), Teamcenter Visualization V13.2 (All versions < V13.2.0.14), Teamcenter Visualization V14.1 (All versions < V14.1.0.10), Teamcenter Visualization V14.2 (All versions < V14.2.0.5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted TIFF files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2512), Simcenter Nastran (All versions < V2512). The affected applications contains an out of bounds read vulnerability while parsing specially crafted NDB files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.184), Teamcenter Visualization V14.1 (All versions), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate if a certain SNMP key exists. An attacker could use this to trigger a reboot of an affected device by requesting specific SNMP information from the device.
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24543)
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24237)
libcurl versions from 7.36.0 to before 7.64.0 is vulnerable to a heap buffer out-of-bounds read. The function handling incoming NTLM type-2 messages (`lib/vauth/ntlm.c:ntlm_decode_type2_target`) does not validate incoming data correctly and is subject to an integer overflow vulnerability. Using that overflow, a malicious or broken NTLM server could trick libcurl to accept a bad length + offset combination that would lead to a buffer read out-of-bounds.
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly restrict the size of generated log files. This could allow an unauthenticated remote attacker to trigger a large amount of logged events to exhaust the system's resources and create a denial of service condition.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in NX (All versions < V2406.3000). The affected applications contains an out of bounds read vulnerability while parsing specially crafted PRT files. This could allow an attacker to crash the application or execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in PS/IGES Parasolid Translator Component (All versions < V29.0.258), Solid Edge (All versions < V226.00 Update 03). The affected applications contains an out of bounds read vulnerability while parsing specially crafted IGS files. This could allow an attacker to crash the application or execute code in the context of the current process. (ZDI-CAN-26755)
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information.
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted BMP files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20308, ZDI-CAN-20345)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20432)
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20334)
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2024 (All versions < V224.0 Update 9). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PSM files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 5). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21575)
A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21564)