Assigner-siemens
Assigner Org ID-cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At-12 Aug, 2025 | 11:17
Updated At-12 Aug, 2025 | 13:34
Rejected At-
Credits

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions). The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:siemens
Assigner Org ID:cec7a2ec-15b4-4faf-bd53-b40f371f3a77
Published At:12 Aug, 2025 | 11:17
Updated At:12 Aug, 2025 | 13:34
Rejected At:
▼CVE Numbering Authority (CNA)

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions). The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.

Affected Products
Vendor
Siemens AGSiemens
Product
SINEC Traffic Analyzer
Default Status
unknown
Versions
Affected
  • From 0 before * (custom)
Problem Types
TypeCWE IDDescription
CWECWE-300CWE-300: Channel Accessible by Non-Endpoint
Type: CWE
CWE ID: CWE-300
Description: CWE-300: Channel Accessible by Non-Endpoint
Metrics
VersionBase scoreBase severityVector
3.17.4HIGH
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
4.07.5HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Version: 3.1
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 4.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://cert-portal.siemens.com/productcert/html/ssa-517338.html
N/A
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-517338.html
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:productcert@siemens.com
Published At:12 Aug, 2025 | 12:15
Updated At:20 Aug, 2025 | 20:56

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions). The affected application uses a monitoring interface that is not operating in a strictly passive mode. This could allow an attacker to interact with the interface, leading to man-in-the-middle attacks.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.5HIGH
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Secondary3.17.4HIGH
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary3.17.0HIGH
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 4.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Secondary
Version: 3.1
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Primary
Version: 3.1
Base score: 7.0
Base severity: HIGH
Vector:
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Siemens AG
siemens
>>sinec_traffic_analyzer>>Versions before 3.0(exclusive)
cpe:2.3:a:siemens:sinec_traffic_analyzer:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-300Primaryproductcert@siemens.com
CWE ID: CWE-300
Type: Primary
Source: productcert@siemens.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://cert-portal.siemens.com/productcert/html/ssa-517338.htmlproductcert@siemens.com
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/html/ssa-517338.html
Source: productcert@siemens.com
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

0Records found

CVE-2020-13630
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7||HIGH
EPSS-0.18% / 39.48%
||
7 Day CHG~0.00%
Published-27 May, 2020 | 14:42
Updated-04 Aug, 2024 | 12:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

ext/fts3/fts3.c in SQLite before 3.32.0 has a use-after-free in fts3EvalNextRow, related to the snippet feature.

Action-Not Available
Vendor-sqliten/aNetApp, Inc.Debian GNU/LinuxOracle CorporationCanonical Ltd.Siemens AGApple Inc.Fedora ProjectBrocade Communications Systems, Inc. (Broadcom Inc.)
Product-ubuntu_linuxitunesiphone_oscloud_backupsqlitecommunications_network_charging_and_controloutside_in_technologymacoshci_compute_nodeicloudsinec_infrastructure_network_servicesdebian_linuxipadostvoswatchosfedorazfs_storage_appliance_kitsolidfire\,_enterprise_sds_\&_hci_storage_nodehci_compute_node_firmwarefabric_operating_systemn/a
CWE ID-CWE-416
Use After Free
CVE-2025-40769
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.02% / 3.42%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 11:17
Updated-12 Aug, 2025 | 14:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V3.0). The affected application uses a Content Security Policy that allows unsafe script execution methods. This could allow an attacker to execute unauthorized scripts, potentially leading to cross-site scripting attacks.

Action-Not Available
Vendor-Siemens AG
Product-SINEC Traffic Analyzer
CWE ID-CWE-1164
Irrelevant Code
CVE-2025-23403
Matching Score-8
Assigner-Siemens
ShareView Details
Matching Score-8
Assigner-Siemens
CVSS Score-7.3||HIGH
EPSS-0.02% / 2.87%
||
7 Day CHG~0.00%
Published-11 Feb, 2025 | 10:29
Updated-08 Apr, 2025 | 08:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures.

Action-Not Available
Vendor-Siemens AG
Product-SIMATIC IPC DiagMonitorSIMATIC IPC DiagBase
CWE ID-CWE-732
Incorrect Permission Assignment for Critical Resource
CVE-2021-22890
Matching Score-6
Assigner-HackerOne
ShareView Details
Matching Score-6
Assigner-HackerOne
CVSS Score-4.3||MEDIUM
EPSS-0.14% / 35.04%
||
7 Day CHG~0.00%
Published-01 Apr, 2021 | 17:46
Updated-09 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

curl 7.63.0 to and including 7.75.0 includes vulnerability that allows a malicious HTTPS proxy to MITM a connection due to bad handling of TLS 1.3 session tickets. When using a HTTPS proxy and TLS 1.3, libcurl can confuse session tickets arriving from the HTTPS proxy but work as if they arrived from the remote server and then wrongly "short-cut" the host handshake. When confusing the tickets, a HTTPS proxy can trick libcurl to use the wrong session ticket resume for the host and thereby circumvent the server TLS certificate check and make a MITM attack to be possible to perform unnoticed. Note that such a malicious HTTPS proxy needs to provide a certificate that curl will accept for the MITMed server for an attack to work - unless curl has been told to ignore the server certificate check.

Action-Not Available
Vendor-n/aNetApp, Inc.Fedora ProjectDebian GNU/LinuxOracle CorporationSplunk LLC (Cisco Systems, Inc.)Broadcom Inc.CURLSiemens AG
Product-debian_linuxsinec_infrastructure_network_servicesfabric_operating_systemsolidfireessbasehci_management_nodeuniversal_forwardercommunications_billing_and_revenue_managementfedorahci_storage_nodelibcurlhttps://github.com/curl/curl
CWE ID-CWE-300
Channel Accessible by Non-Endpoint
CWE ID-CWE-290
Authentication Bypass by Spoofing
CVE-2017-9941
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.4||HIGH
EPSS-0.19% / 41.54%
||
7 Day CHG~0.00%
Published-08 Aug, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.

Action-Not Available
Vendor-n/aSiemens AG
Product-sipass_integratedSiPass integrated All versions before V2.70
CWE ID-CWE-300
Channel Accessible by Non-Endpoint
CVE-2017-6870
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.4||HIGH
EPSS-0.24% / 47.20%
||
7 Day CHG~0.00%
Published-08 Aug, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_wincc_sm\@rtclientSIMATIC WinCC Sm@rtClient for Android
CWE ID-CWE-300
Channel Accessible by Non-Endpoint
CVE-2017-12735
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.4||HIGH
EPSS-0.24% / 47.20%
||
7 Day CHG~0.00%
Published-30 Aug, 2017 | 19:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_8_bm_firmwarelogo\!LOGO! 8 BM (incl. SIPLUS variants)
CWE ID-CWE-300
Channel Accessible by Non-Endpoint
CVE-2023-32634
Matching Score-4
Assigner-Talos
ShareView Details
Matching Score-4
Assigner-Talos
CVSS Score-7.8||HIGH
EPSS-0.01% / 1.34%
||
7 Day CHG~0.00%
Published-12 Oct, 2023 | 15:27
Updated-17 Sep, 2024 | 18:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An authentication bypass vulnerability exists in the CiRpcServerThread() functionality of SoftEther VPN 5.01.9674 and 4.41-9782-beta. An attacker can perform a local man-in-the-middle attack to trigger this vulnerability.

Action-Not Available
Vendor-softetherSoftEther VPNsoftether
Product-vpnSoftEther VPNvpn
CWE ID-CWE-300
Channel Accessible by Non-Endpoint