Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2025-57199

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-03 Dec, 2025 | 00:00
Updated At-03 Dec, 2025 | 16:11
Rejected At-
Credits

AVTECH SECURITY Corporation DGM1104 FullImg-1015-1004-1006-1003 was discovered to contain an authenticated command injection vulnerability in the NetFailDetectD binary. This vulnerability allows attackers to execute arbitrary commands via a crafted input.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:03 Dec, 2025 | 00:00
Updated At:03 Dec, 2025 | 16:11
Rejected At:
▼CVE Numbering Authority (CNA)

AVTECH SECURITY Corporation DGM1104 FullImg-1015-1004-1006-1003 was discovered to contain an authenticated command injection vulnerability in the NetFailDetectD binary. This vulnerability allows attackers to execute arbitrary commands via a crafted input.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://avtech.com
N/A
http://dgm1104.com
N/A
https://github.com/xchg-rax-rax/vulnerability-research/tree/main/CVE-2025-57199
N/A
Hyperlink: http://avtech.com
Resource: N/A
Hyperlink: http://dgm1104.com
Resource: N/A
Hyperlink: https://github.com/xchg-rax-rax/vulnerability-research/tree/main/CVE-2025-57199
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:03 Dec, 2025 | 16:15
Updated At:23 Dec, 2025 | 00:34

AVTECH SECURITY Corporation DGM1104 FullImg-1015-1004-1006-1003 was discovered to contain an authenticated command injection vulnerability in the NetFailDetectD binary. This vulnerability allows attackers to execute arbitrary commands via a crafted input.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Avtec (Motorola Solutions)
avtech
>>dgm1104_firmware>>-
cpe:2.3:o:avtech:dgm1104_firmware:-:*:*:*:*:*:*:*
Avtec (Motorola Solutions)
avtech
>>dgm1104>>-
cpe:2.3:h:avtech:dgm1104:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://avtech.comcve@mitre.org
Product
http://dgm1104.comcve@mitre.org
Broken Link
https://github.com/xchg-rax-rax/vulnerability-research/tree/main/CVE-2025-57199cve@mitre.org
Exploit
Third Party Advisory
Hyperlink: http://avtech.com
Source: cve@mitre.org
Resource:
Product
Hyperlink: http://dgm1104.com
Source: cve@mitre.org
Resource:
Broken Link
Hyperlink: https://github.com/xchg-rax-rax/vulnerability-research/tree/main/CVE-2025-57199
Source: cve@mitre.org
Resource:
Exploit
Third Party Advisory

Change History

0
Information is not available yet

Similar CVEs

538Records found

CVE-2026-3066
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.60% / 69.77%
||
7 Day CHG~0.00%
Published-24 Feb, 2026 | 03:02
Updated-24 Feb, 2026 | 21:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HummerRisk Cloud Compliance Scanning PlatformUtils.java fixedCommand command injection

A flaw has been found in HummerRisk up to 1.5.0. This vulnerability affects the function fixedCommand of the file hummer-common/hummer-common-core/src/main/java/com/hummer/common/core/utils/PlatformUtils.java of the component Cloud Compliance Scanning. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-hummerriskn/a
Product-hummerriskHummerRisk
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41144
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-0.60% / 69.64%
||
7 Day CHG~0.00%
Published-27 Jan, 2023 | 18:08
Updated-10 Mar, 2025 | 21:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
OpenMage LTS authenticated remote code execution through layout update

OpenMage LTS is an e-commerce platform. Prior to versions 19.4.22 and 20.0.19, a layout block was able to bypass the block blacklist to execute remote code. Versions 19.4.22 and 20.0.19 contain a patch for this issue.

Action-Not Available
Vendor-openmageOpenMage
Product-magentomagento-lts
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2956
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.38%
||
7 Day CHG~0.00%
Published-22 Feb, 2026 | 22:02
Updated-25 Feb, 2026 | 17:43
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
qinming99 dst-admin restore revertBackup command injection

A security flaw has been discovered in qinming99 dst-admin up to 1.5.0. This affects the function revertBackup of the file /home/restore. The manipulation of the argument Name results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-dst-admin_projectqinming99
Product-dst-admindst-admin
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11292
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG+0.30%
Published-05 Oct, 2025 | 14:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 formBSSetSitesurvey command injection

A weakness has been identified in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/formBSSetSitesurvey. Executing a manipulation of the argument wan_ipaddr can lead to command injection. The attack can be launched remotely. The exploit has been made available to the public and could be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10963
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 19:02
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_4016F0 command injection

A security flaw has been discovered in Wavlink NU516U1 M16U1_V240425. Affected is the function sub_4016F0 of the file /cgi-bin/firewall.cgi. The manipulation of the argument del_flag results in command injection. It is possible to launch the attack remotely. The exploit has been released to the public and may be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11095
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 04:02
Updated-02 Oct, 2025 | 19:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X delete_offline_device command injection

A vulnerability was detected in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/delete_offline_device. Performing manipulation of the argument delvalue results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11298
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG+0.30%
Published-05 Oct, 2025 | 18:02
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 formSetWanStatic command injection

A vulnerability was determined in Belkin F9K1015 1.00.10. Impacted is an unknown function of the file /goform/formSetWanStatic. Executing a manipulation of the argument m_wan_ipaddr can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10958
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 17:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 AddMac wireless.cgi sub_403010 command injection

A flaw has been found in Wavlink NU516U1 M16U1_V240425. Impacted is the function sub_403010 of the file /cgi-bin/wireless.cgi of the component AddMac Page. This manipulation of the argument macAddr causes command injection. Remote exploitation of the attack is possible. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10960
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 18:02
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 DeleteMac wireless.cgi sub_402D1C command injection

A vulnerability was found in Wavlink NU516U1 M16U1_V240425. The impacted element is the function sub_402D1C of the file /cgi-bin/wireless.cgi of the component DeleteMac Page. Performing manipulation of the argument delete_list results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11098
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 05:32
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_wifi_blacklists command injection

A vulnerability was found in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_wifi_blacklists. The manipulation of the argument macList results in command injection. The attack may be performed from remote. The exploit has been made public and could be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11100
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 06:32
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_wifi_blacklists uci_set command injection

A vulnerability was identified in D-Link DIR-823X 250416. This affects the function uci_set of the file /goform/set_wifi_blacklists. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11096
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 04:32
Updated-02 Oct, 2025 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X diag_traceroute command injection

A flaw has been found in D-Link DIR-823X 250416. This issue affects some unknown processing of the file /goform/diag_traceroute. Executing manipulation of the argument target_addr can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-3064
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.60% / 69.77%
||
7 Day CHG~0.00%
Published-24 Feb, 2026 | 02:32
Updated-24 Feb, 2026 | 21:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
HummerRisk Cloud Task Scheduler ResourceCreateService.java command injection

A security vulnerability has been detected in HummerRisk up to 1.5.0. Affected by this issue is some unknown functionality of the file ResourceCreateService.java of the component Cloud Task Scheduler. Such manipulation of the argument regionId leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-hummerriskn/a
Product-hummerriskHummerRisk
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11285
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.64% / 70.81%
||
7 Day CHG+0.37%
Published-05 Oct, 2025 | 06:02
Updated-09 Oct, 2025 | 17:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
samanhappy MCPHub serverController.ts os command injection

A vulnerability was found in samanhappy MCPHub up to 0.9.10. Affected by this issue is some unknown functionality of the file src/controllers/serverController.ts. The manipulation of the argument command/args results in os command injection. The attack can be launched remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-mcphubxsamanhappy
Product-mcphubMCPHub
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-11303
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG+0.30%
Published-05 Oct, 2025 | 20:32
Updated-24 Feb, 2026 | 07:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Belkin F9K1015 mp command injection

A vulnerability was detected in Belkin F9K1015 1.00.10. Affected is an unknown function of the file /goform/mp. Performing a manipulation of the argument command results in command injection. The attack may be initiated remotely. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Belkin International, Inc.
Product-f9k1015_firmwaref9k1015F9K1015
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38556
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-18.63% / 95.36%
||
7 Day CHG~0.00%
Published-24 Aug, 2021 | 12:33
Updated-04 Aug, 2024 | 01:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

includes/configure_client.php in RaspAP 2.6.6 allows attackers to execute commands via command injection.

Action-Not Available
Vendor-raspapn/a
Product-raspapn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10962
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 18:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 SetName wireless.cgi sub_403198 command injection

A vulnerability was identified in Wavlink NU516U1 M16U1_V240425. This impacts the function sub_403198 of the file /cgi-bin/wireless.cgi of the component SetName Page. The manipulation of the argument mac_5g leads to command injection. It is possible to initiate the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-3101
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.51% / 66.68%
||
7 Day CHG~0.00%
Published-24 Feb, 2026 | 14:32
Updated-27 Feb, 2026 | 19:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Intelbras TIP 635G Ping os command injection

A vulnerability was found in Intelbras TIP 635G 1.12.3.5. This vulnerability affects unknown code of the component Ping Handler. The manipulation results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-intelbrasIntelbras
Product-tip_635g_firmwaretip_635gTIP 635G
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-11099
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 06:02
Updated-02 Oct, 2025 | 18:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X delete_prohibiting uci_del command injection

A vulnerability was determined in D-Link DIR-823X 250416. The impacted element is the function uci_del of the file /goform/delete_prohibiting. This manipulation of the argument delvalue causes command injection. It is possible to initiate the attack remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11092
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 02:02
Updated-02 Oct, 2025 | 19:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_switch_settings sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 250416. Affected by this issue is the function sub_412E7C of the file /goform/set_switch_settings. This manipulation of the argument port causes command injection. The attack may be initiated remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10964
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 19:32
Updated-07 Oct, 2025 | 20:50
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_401B30 command injection

A weakness has been identified in Wavlink NU516U1. Affected by this vulnerability is the function sub_401B30 of the file /cgi-bin/firewall.cgi. This manipulation of the argument remoteManagementEnabled causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11097
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 05:02
Updated-02 Oct, 2025 | 18:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_device_name command injection

A vulnerability has been found in D-Link DIR-823X 250416. Impacted is an unknown function of the file /goform/set_device_name. The manipulation of the argument mac leads to command injection. The attack is possible to be carried out remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10959
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.52% / 66.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2025 | 17:32
Updated-07 Oct, 2025 | 20:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink NU516U1 firewall.cgi sub_401778 command injection

A vulnerability has been found in Wavlink NU516U1 M16U1_V240425. The affected element is the function sub_401778 of the file /cgi-bin/firewall.cgi. Such manipulation of the argument dmz_flag leads to command injection. The attack can be executed remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-nu516u1_firmwarewl-nu516u1NU516U1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10814
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.33%
||
7 Day CHG~0.00%
Published-22 Sep, 2025 | 20:32
Updated-24 Sep, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X goahead command injection

A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.99% / 77.15%
||
7 Day CHG~0.00%
Published-28 Sep, 2025 | 21:32
Updated-03 Oct, 2025 | 13:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC18 AdvSetLanip command injection

A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac18ac18_firmwareAC18
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11523
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.43% / 62.42%
||
7 Day CHG~0.00%
Published-09 Oct, 2025 | 01:02
Updated-24 Feb, 2026 | 06:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC7 AdvSetLanip command injection

A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac7_firmwareac7AC7
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-11138
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.62% / 70.20%
||
7 Day CHG~0.00%
Published-29 Sep, 2025 | 03:02
Updated-10 Oct, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
mirweiye wenkucms common.php createPathOne os command injection

A vulnerability was found in mirweiye wenkucms up to 3.4. This impacts the function createPathOne of the file app/common/common.php. The manipulation results in os command injection. The attack may be launched remotely. The exploit has been made public and could be used.

Action-Not Available
Vendor-wenkucms_projectmirweiye
Product-wenkucmswenkucms
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-3855
Matching Score-4
Assigner-TR-CERT (Computer Emergency Response Team of the Republic of Türkiye)
ShareView Details
Matching Score-4
Assigner-TR-CERT (Computer Emergency Response Team of the Republic of Türkiye)
CVSS Score-8.8||HIGH
EPSS-5.45% / 90.28%
||
7 Day CHG+0.46%
Published-24 Feb, 2023 | 13:02
Updated-18 May, 2026 | 13:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection in Liman Central Management System

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Liman Central Management System Liman MYS (HTTP/Controllers, CronMail, Jobs modules) allows Command Injection. This issue affects Liman Central Management System: from 1.7.0 before 1.8.3-462.

Action-Not Available
Vendor-limanLiman Central Management System
Product-port_mysLiman Central Management System
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2167
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.41% / 61.36%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:02
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Totolink WA300 cstecgi.cgi setAPNetwork os command injection

A vulnerability was detected in Totolink WA300 5.2cu.7112_B20190227. The impacted element is the function setAPNetwork of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Ipaddr results in os command injection. The attack may be performed from remote. The exploit is now public and may be used.

Action-Not Available
Vendor-TOTOLINK
Product-wa300wa300_firmwareWA300
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10629
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.21% / 43.52%
||
7 Day CHG+0.02%
Published-18 Sep, 2025 | 00:32
Updated-22 Sep, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Simple Service Discovery Protocol Service cgibin ssdpcgi_main command injection

A vulnerability was determined in D-Link DIR-852 1.00CN B09. This issue affects the function ssdpcgi_main of the file htodcs/cgibin of the component Simple Service Discovery Protocol Service. Executing manipulation of the argument ST can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10628
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.47% / 64.75%
||
7 Day CHG+0.05%
Published-18 Sep, 2025 | 00:02
Updated-22 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Web Management hedwig.cgi command injection

A vulnerability was found in D-Link DIR-852 1.00CN B09. This vulnerability affects unknown code of the file /htdocs/cgibin/hedwig.cgi of the component Web Management Interface. Performing manipulation results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-30898
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-8.8||HIGH
EPSS-0.03% / 8.44%
||
7 Day CHG-0.05%
Published-18 Apr, 2026 | 06:20
Updated-22 Apr, 2026 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Apache Airflow: Bad example of BashOperator shell injection via dag_run.conf

An example of BashOperator in Airflow documentation suggested a way of passing dag_run.conf in the way that could cause unsanitized user input to be used to escalate privileges of UI user to allow execute code on worker. Users should review if any of their own DAGs have adopted this incorrect advice.

Action-Not Available
Vendor-The Apache Software Foundation
Product-airflowApache Airflow
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10634
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.16% / 36.52%
||
7 Day CHG+0.02%
Published-18 Sep, 2025 | 01:02
Updated-24 Sep, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X Environment Variable goahead sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. This manipulation of the argument terminal_addr/server_ip/server_port causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10020
Matching Score-4
Assigner-Zohocorp
ShareView Details
Matching Score-4
Assigner-Zohocorp
CVSS Score-8.5||HIGH
EPSS-1.46% / 81.06%
||
7 Day CHG~0.00%
Published-21 Oct, 2025 | 12:12
Updated-26 Feb, 2026 | 16:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection

Zohocorp ManageEngine ADManager Plus version before 8024 are vulnerable to authenticated command injection vulnerability in the Custom Script component.

Action-Not Available
Vendor-Zoho Corporation Pvt. Ltd.
Product-manageengine_admanager_plusManageEngine ADManager Plus
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2178
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.38% / 59.32%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 19:02
Updated-05 Mar, 2026 | 21:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
r-huijts xcode-mcp-server run_lldb index.ts registerXcodeTools command injection

A vulnerability was found in r-huijts xcode-mcp-server up to f3419f00117aa9949e326f78cc940166c88f18cb. This affects the function registerXcodeTools of the file src/tools/xcode/index.ts of the component run_lldb. The manipulation of the argument args results in command injection. It is possible to launch the attack remotely. The exploit has been made public and could be used. This product takes the approach of rolling releases to provide continious delivery. Therefore, version details for affected and updated releases are not available. The patch is identified as 11f8d6bacadd153beee649f92a78a9dad761f56f. Applying a patch is advised to resolve this issue.

Action-Not Available
Vendor-r-huijtsr-huijts
Product-xcode_mcp_serverxcode-mcp-server
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10442
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.76% / 73.64%
||
7 Day CHG+0.08%
Published-15 Sep, 2025 | 11:02
Updated-19 Sep, 2025 | 20:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda AC9/AC15 exeCommand formexeCommand os command injection

A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-ac15_firmwareac9_firmwareac9ac15AC9AC15
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-10401
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.34% / 57.10%
||
7 Day CHG+0.04%
Published-14 Sep, 2025 | 15:32
Updated-24 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823x diag_ping command injection

A vulnerability was detected in D-Link DIR-823x up to 250416. The affected element is an unknown function of the file /goform/diag_ping. Performing manipulation of the argument target_addr results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823x
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-37102
Matching Score-4
Assigner-Huawei Technologies
ShareView Details
Matching Score-4
Assigner-Huawei Technologies
CVSS Score-8.8||HIGH
EPSS-0.64% / 70.88%
||
7 Day CHG~0.00%
Published-23 Nov, 2021 | 15:02
Updated-04 Aug, 2024 | 01:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

There is a command injection vulnerability in CMA service module of FusionCompute product when processing the default certificate file. The software constructs part of a command using external special input from users, but the software does not sufficiently validate the user input. Successful exploit could allow the attacker to inject certain commands to the system. Affected product versions include: FusionCompute 6.0.0, 6.3.0, 6.3.1, 6.5.0, 6.5.1, 8.0.0.

Action-Not Available
Vendor-n/aHuawei Technologies Co., Ltd.
Product-fusioncomputeFusionCompute
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10325
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.63% / 70.60%
||
7 Day CHG+0.07%
Published-12 Sep, 2025 | 20:02
Updated-02 Oct, 2025 | 20:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Wavlink WL-WN578W2 login.cgi sub_401BA4 command injection

A vulnerability was identified in Wavlink WL-WN578W2 221110. This impacts the function sub_401340/sub_401BA4 of the file /cgi-bin/login.cgi. Such manipulation of the argument ipaddr leads to command injection. It is possible to launch the attack remotely. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-WAVLINK Technology Ltd.
Product-wl-wn578w2_firmwarewl-wn578w2WL-WN578W2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-38116
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
ShareView Details
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
CVSS Score-8.8||HIGH
EPSS-0.18% / 38.83%
||
7 Day CHG~0.00%
Published-22 Nov, 2024 | 15:34
Updated-10 Apr, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Possible Command injection Vulnerability in OpenText iManager

Possible Elevation of Privilege Vulnerability in iManager has been discovered in OpenText™ iManager. This impacts all versions before 3.2.5

Action-Not Available
Vendor-Open Text CorporationMicro Focus International Limited
Product-imanageriManagerimanager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-0593
Matching Score-4
Assigner-SICK AG
ShareView Details
Matching Score-4
Assigner-SICK AG
CVSS Score-8.8||HIGH
EPSS-0.14% / 33.51%
||
7 Day CHG~0.00%
Published-14 Feb, 2025 | 20:18
Updated-15 Apr, 2026 | 00:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SICK Lector8xx and InspectorP8xx vulnerable for code execution

The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device.

Action-Not Available
Vendor-SICK AG
Product-SICK Lector8xxSICK InspectorP8xx
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-8828
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.84% / 74.93%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:32
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 ipv6cmd os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-34748
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-8.8||HIGH
EPSS-1.27% / 79.72%
||
7 Day CHG~0.00%
Published-06 Oct, 2021 | 19:46
Updated-07 Nov, 2024 | 21:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Cisco Intersight Virtual Appliance Command Injection Vulnerability

A vulnerability in the web-based management interface of Cisco Intersight Virtual Appliance could allow an authenticated, remote attacker to perform a command injection attack on an affected device. This vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by using the web-based management interface to execute a command using crafted input. A successful exploit could allow the attacker to execute arbitrary commands using root-level privileges on an affected device.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-intersight_virtual_applianceCisco Intersight Virtual Appliance
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-34809
Matching Score-4
Assigner-Synology Inc.
ShareView Details
Matching Score-4
Assigner-Synology Inc.
CVSS Score-9.9||CRITICAL
EPSS-1.64% / 82.16%
||
7 Day CHG~0.00%
Published-18 Jun, 2021 | 03:00
Updated-16 Sep, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper neutralization of special elements used in a command ('Command Injection') vulnerability in task management component in Synology Download Station before 3.8.16-3566 allows remote authenticated users to execute arbitrary code via unspecified vectors.

Action-Not Available
Vendor-Synology, Inc.
Product-download_stationDownload Station
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-9223
Matching Score-4
Assigner-Zohocorp
ShareView Details
Matching Score-4
Assigner-Zohocorp
CVSS Score-8.8||HIGH
EPSS-1.30% / 79.96%
||
7 Day CHG~0.00%
Published-11 Nov, 2025 | 13:13
Updated-26 Feb, 2026 | 16:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command Injection

Zohocorp ManageEngine Applications Manager versions 178100 and below are vulnerable to authenticated command injection vulnerability due to the improper configuration in the execute program action feature.

Action-Not Available
Vendor-Zoho Corporation Pvt. Ltd.
Product-ManageEngine Applications Manager
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-33964
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.79% / 88.22%
||
7 Day CHG~0.00%
Published-18 Jan, 2022 | 11:26
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

China Mobile An Lianbao WF-1 V1.0.1 router provides a web interface /api/ZRRuleFilter/set_firewall_level which receives parameters by POST request, and the parameter firewall_level has a command injection vulnerability. An attacker can use the vulnerability to execute remote commands.

Action-Not Available
Vendor-chinamobilen/a
Product-an_lianbao_wf-1an_lianbao_wf-1_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-32849
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-78.31% / 99.05%
||
7 Day CHG~0.00%
Published-26 Jan, 2022 | 21:30
Updated-22 Apr, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary command execution in Gerapy

Gerapy is a distributed crawler management framework. Prior to version 0.9.9, an authenticated user could execute arbitrary commands. This issue is fixed in version 0.9.9. There are no known workarounds.

Action-Not Available
Vendor-gerapyGerapy
Product-gerapygerapy
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-33965
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-8.8||HIGH
EPSS-3.79% / 88.22%
||
7 Day CHG~0.00%
Published-18 Jan, 2022 | 12:01
Updated-04 Aug, 2024 | 00:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

China Mobile An Lianbao WF-1 V1.0.1 router provides a web interface /api/ZRMesh/set_ZRMesh which receives parameters by POST request, and the parameter mesh_enable and mesh_device have a command injection vulnerability. An attacker can use the vulnerability to execute remote commands.

Action-Not Available
Vendor-chinamobilen/a
Product-an_lianbao_wf-1_firmwarean_lianbao_wf-1n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-9076
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-1.56% / 81.69%
||
7 Day CHG~0.00%
Published-22 Sep, 2024 | 00:00
Updated-28 Nov, 2024 | 07:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
DedeCMS article_string_mix.php os command injection

A vulnerability was found in DedeCMS up to 5.7.115. It has been rated as critical. This issue affects some unknown processing of the file /dede/article_string_mix.php. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-n/aDedeCMS
Product-dedecmsDedeCMSdedecms
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-27811
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.8||HIGH
EPSS-1.12% / 78.49%
||
7 Day CHG+0.15%
Published-17 Mar, 2026 | 23:43
Updated-19 Mar, 2026 | 18:00
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Roxy-WI has a Command Injection via diff parameter in config comparison allows authenticated RCE

Roxy-WI is a web interface for managing Haproxy, Nginx, Apache and Keepalived servers. Prior to version 8.2.6.3, a command injection vulnerability exists in the `/config/compare/<service>/<server_ip>/show` endpoint, allowed authenticated users to execute arbitrary system commands on the app host. The vulnerability exists in `app/modules/config/config.py` on line 362, where user input is directly formatted in the template string that is eventually executed. Version 8.2.6.3 fixes the issue.

Action-Not Available
Vendor-roxy-wiroxy-wi
Product-roxy-wiroxy-wi
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • ...
  • 10
  • 11
  • Next
Details not found