An issue was discovered in TitanHQ SpamTitan Email Security Gateway 8.00.x before 8.00.101 and 8.01.x before 8.01.14. The file quarantine.php within the SpamTitan interface allows unauthenticated users to trigger account-level actions using a crafted GET request. Notably, when a non-existent email address is provided as part of the email parameter, SpamTitan will automatically create a user record and associate quarantine settings with it - all without requiring authentication.
CyberPanel versions prior to 2.4.4 contain an authentication bypass vulnerability in the AI Scanner worker API endpoints that allows unauthenticated remote attackers to write arbitrary data to the database by sending requests to the /api/ai-scanner/status-webhook and /api/ai-scanner/callback endpoints. Attackers can exploit the lack of authentication checks to cause denial of service through storage exhaustion, corrupt scan history records, and pollute database fields with malicious data.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
HashiCorp Vault Enterprise 1.7.0 through 1.9.7, 1.10.4, and 1.11.0 clusters using Integrated Storage expose an unauthenticated API endpoint that could be abused to override the voter status of a node within a Vault HA cluster, introducing potential for future data loss or catastrophic failure. Fixed in Vault Enterprise 1.9.8, 1.10.5, and 1.11.1.
TadTools special page is vulnerable to authorization bypass, thus remote attackers can use the specific parameter to delete arbitrary files in the system without logging in.
The specific APIs of Parking Management System from ZONG YU has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access specific APIs and operate system functions. These functions include opening gates and restarting the system.
The WordPress plugin, WP Database Reset through 3.1, contains a flaw that allowed any unauthenticated user to reset any table in the database to the initial WordPress set-up state (deleting all site content stored in that table), as demonstrated by a wp-admin/admin-post.php?db-reset-tables[]=comments URI.
AVideo versions prior to 20.1 with the ImageGallery plugin enabled is vulnerable to unauthenticated file upload and deletion. Plugin endpoints responsible for managing gallery images fail to enforce authentication checks and do not validate ownership, allowing unauthenticated attackers to upload or delete images associated with any image-based video.
An issue has recently been discovered in Arista EOS where certain gNOI APIs incorrectly skip authorization and authentication which could potentially allow a factory reset of the device.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) expose a set of PHP scripts under the `console_release` directory without requiring authentication. An unauthenticated remote attacker can invoke these endpoints to re‑configure networked printers, add or delete RFID badge devices, or otherwise modify device settings. This vulnerability has been identified by the vendor as: V-2024-029 — No Authentication to Modify Devices.
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
A CWE-306 "Missing Authentication for Critical Function" in maxprofile/setup/routes.lua in Q-Free MaxTime less than or equal to version 2.11.0 allows an unauthenticated remote attacker to factory reset the device via crafted HTTP requests.
An issue was discovered on D-Link DSL-2640B B2 EU_4.01B devices. The device can be reset to its default configuration by accessing an unauthenticated URL.
SiRcom SMART Alert (SiSA) allows unauthorized access to backend APIs. This allows an unauthenticated attacker to bypass the login screen using browser developer tools, gaining access to restricted parts of the application.
Missing authentication in multiple administrative action scripts under /admin/ in ProjectWorlds Online Time Table Generator 1.0 allows remote attackers to perform unauthorized administrative operations (e.g.,adding records, deleting records) via direct HTTP requests to affected endpoints without a valid session.
themegrill-demo-importer before 1.6.2 does not require authentication for wiping the database, because of a reset_wizard_actions hook.
An unauthenticated remote attacker may use a missing authentication for critical function vulnerability to reboot or erase the affected devices resulting in data loss and/or a DoS.
Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a Honeywell Experion LX Control Data Access (CDA) EpicMo protocol with unauthenticated functionality issue. The affected components are characterized as: Honeywell Control Data Access (CDA) EpicMo (55565/TCP). The potential impact is: Firmware manipulation, Denial of service. The Honeywell Experion LX Distributed Control System (DCS) utilizes the Control Data Access (CDA) EpicMo protocol (55565/TCP) for device diagnostics and maintenance purposes. This protocol does not have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality. There is no authentication functionality on the protocol in question. An attacker capable of invoking the protocols' functionalities could issue firmware download commands potentially allowing for firmware manipulation and reboot devices causing denial of service.
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
An access control issue in Zammad v5.0.3 allows attackers to write entries to the CTI caller log without authentication. This vulnerability can allow attackers to execute phishing attacks or cause a Denial of Service (DoS).
Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions.
On ICL ScadaFlex II SCADA Controller SC-1 and SC-2 1.03.07 devices, unauthenticated remote attackers can overwrite, delete, or create files.
AMI BMC contains a vulnerability in the IPMI handler, where an unauthenticated host is allowed to write to a host SPI flash, bypassing secure boot protections. An exploitation of this vulnerability may lead to a loss of integrity or denial of service.