Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-27848

Summary
Assigner-ENISA
Assigner Org ID-a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published At-25 Feb, 2026 | 15:15
Updated At-26 Feb, 2026 | 16:51
Rejected At-
Credits

Missing neutralization in Linksys MR9600, Linksys MX4200

Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:ENISA
Assigner Org ID:a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published At:25 Feb, 2026 | 15:15
Updated At:26 Feb, 2026 | 16:51
Rejected At:
▼CVE Numbering Authority (CNA)
Missing neutralization in Linksys MR9600, Linksys MX4200

Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.

Affected Products
Vendor
Linksys Holdings, Inc.Linksys
Product
MR9600
Default Status
affected
Versions
Affected
  • 1.0.4.205530
Vendor
Linksys Holdings, Inc.Linksys
Product
MX4200
Default Status
unaffected
Versions
Affected
  • 1.0.13.210200
Problem Types
TypeCWE IDDescription
CWECWE-78CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Type: CWE
CWE ID: CWE-78
Description: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-010.txt
third-party-advisory
technical-description
Hyperlink: https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-010.txt
Resource:
third-party-advisory
technical-description
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Published At:25 Feb, 2026 | 16:23
Updated At:27 Feb, 2026 | 14:06

Due to missing neutralization of special elements, OS commands can be injected via the handshake of a TLS-SRP connection, which are ultimately run as the root user. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-78Secondarya6d3dc9e-0591-4a13-bce7-0f5b31ff6158
CWE ID: CWE-78
Type: Secondary
Source: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-010.txta6d3dc9e-0591-4a13-bce7-0f5b31ff6158
N/A
Hyperlink: https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2025-010.txt
Source: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1407Records found

CVE-2026-27849
Matching Score-10
Assigner-EU Agency for Cybersecurity (ENISA)
ShareView Details
Matching Score-10
Assigner-EU Agency for Cybersecurity (ENISA)
CVSS Score-9.8||CRITICAL
EPSS-0.05% / 14.68%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 16:20
Updated-27 Feb, 2026 | 14:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing neutralization in Linksys MR9600, Linksys MX4200

Due to missing neutralization of special elements, OS commands can be injected via the update functionality of a TLS-SRP connection, which is normally used for configuring devices inside the mesh network. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-MX4200MR9600
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5443
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.30%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 11:31
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection

A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5444
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.30%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 12:00
Updated-10 Jun, 2025 | 15:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_UpgradeFWByBBS os command injection

A vulnerability has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this vulnerability is the function RP_UpgradeFWByBBS of the file /goform/RP_UpgradeFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5447
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.97% / 83.29%
||
7 Day CHG+0.24%
Published-02 Jun, 2025 | 13:31
Updated-02 Jul, 2025 | 01:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 ssid1MACFilter os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been declared as critical. This vulnerability affects the function ssid1MACFilter of the file /goform/ssid1MACFilter. The manipulation of the argument apselect_%d/newap_text_%d leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re6500re9000re6250re6350re7000re9000_firmwarere7000_firmwarere6500_firmwarere6300_firmwarere6350_firmwarere6250_firmwareRE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5445
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.58% / 81.30%
||
7 Day CHG+0.19%
Published-02 Jun, 2025 | 12:31
Updated-10 Jun, 2025 | 15:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkFWByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 and classified as critical. Affected by this issue is the function RP_checkFWByBBS of the file /goform/RP_checkFWByBBS. The manipulation of the argument type/ch/ssidhex/security/extch/pwd/mode/ip/nm/gw leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350re6350_firmwarere6500re7000_firmwarere6300_firmwarere6500_firmwarere6300re6250_firmwarere9000_firmwarere7000re6250re9000RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-27847
Matching Score-8
Assigner-EU Agency for Cybersecurity (ENISA)
ShareView Details
Matching Score-8
Assigner-EU Agency for Cybersecurity (ENISA)
CVSS Score-9.8||CRITICAL
EPSS-0.05% / 14.68%
||
7 Day CHG~0.00%
Published-25 Feb, 2026 | 15:10
Updated-27 Feb, 2026 | 14:06
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Missing authentication in Linksys MR9600, Linksys MX4200

Due to improper neutralization of special elements, SQL statements can be injected via the handshake of a TLS-SRP connection. This can be used to inject known credentials into the database that can be utilized to successfully complete the handshake and use the protected service. This issue affects MR9600: 1.0.4.205530; MX4200: 1.0.13.210200.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-MX4200MR9600
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-4999
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.49% / 65.22%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi sub_4153FC command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000 and classified as critical. Affected by this issue is the function sub_4153FC of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument supplicant_rnd_id_en leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-5000
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.49% / 65.22%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 21:00
Updated-12 Jun, 2025 | 16:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys FGW3000-AH/FGW3000-HK HTTP POST Request sysconf.cgi control_panel_sw command injection

A vulnerability was found in Linksys FGW3000-AH and FGW3000-HK up to 1.0.17.000000. It has been classified as critical. This affects the function control_panel_sw of the file /cgi-bin/sysconf.cgi of the component HTTP POST Request Handler. The manipulation of the argument filename leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-fgw3000-ahfgw3000-hkfgw3000-hk_firmwarefgw3000-ah_firmwareFGW3000-HKFGW3000-AH
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2024-8408
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.29% / 52.37%
||
7 Day CHG~0.00%
Published-04 Sep, 2024 | 14:00
Updated-05 Sep, 2024 | 14:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys WRT54G POST Parameter apply.cgi validate_services_port stack-based overflow

A vulnerability was found in Linksys WRT54G 4.21.5. It has been rated as critical. Affected by this issue is the function validate_services_port of the file /apply.cgi of the component POST Parameter Handler. The manipulation of the argument services_array leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wrt54g_firmwarewrt54gWRT54Gwrt54g
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-8829
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:02
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_red os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8821
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 00:02
Updated-04 Sep, 2025 | 18:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasic os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8828
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:32
Updated-04 Sep, 2025 | 18:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setIpv6 ipv6cmd os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected is the function ipv6cmd of the file /goform/setIpv6. The manipulation of the argument Ipv6PriDns/Ipv6SecDns/Ipv6StaticGateway/LanIpv6Addr/LanPrefixLen/pppoeUser/pppoePass/pppoeIdleTime/pppoeRedialPeriod/Ipv6in4_PrefixLen/LocalIpv6/RemoteIpv4/LanIPv6_Prefix/LanPrefixLen/ipv6to4Relay/ipv6rdRelay/tunrd_PrefixLen/wan_UseLinkLocal/Ipv6StaticIp/Ipv6PrefixLen leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-3955
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-1.53% / 81.07%
||
7 Day CHG~0.00%
Published-17 Oct, 2018 | 02:00
Updated-16 Sep, 2024 | 16:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable operating system command injection exists in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04). Specially crafted entries to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send an authenticated HTTP request to trigger this vulnerability. Data entered into the 'Domain Name' input field through the web portal is submitted to apply.cgi as the value to the 'wan_domain' POST parameter. The wan_domain data goes through the nvram_set process described above. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-e2500_firmwaree1200_firmwaree1200e2500ESeries E1200ESeries E2500
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-3953
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-68.45% / 98.57%
||
7 Day CHG~0.00%
Published-17 Oct, 2018 | 02:00
Updated-17 Sep, 2024 | 02:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAM. Data entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal, it enters a code path that continues until it reaches offset 0x0042B5C4 in the 'start_lltd' function. Within the 'start_lltd' function, a 'nvram_get' call is used to obtain the value of the user-controlled 'machine_name' NVRAM entry. This value is then entered directly into a command intended to write the host name to a file and subsequently executed.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-e2500_firmwaree1200_firmwaree1200e2500ESeries E1200ESeries E2500
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2018-3954
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-7.2||HIGH
EPSS-7.96% / 91.91%
||
7 Day CHG~0.00%
Published-17 Oct, 2018 | 02:00
Updated-17 Sep, 2024 | 03:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAMData entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-e2500_firmwaree1200_firmwaree1200e2500ESeries E1200ESeries E2500
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9528
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-0.21% / 42.98%
||
7 Day CHG~0.00%
Published-27 Aug, 2025 | 13:02
Updated-09 Oct, 2025 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys E1700 systemCommand os command injection

A vulnerability was determined in Linksys E1700 1.0.0.4.003. This vulnerability affects the function systemCommand of the file /goform/systemCommand. Executing manipulation of the argument command can lead to os command injection. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-e1700e1700_firmwareE1700
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8830
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 04:32
Updated-04 Sep, 2025 | 18:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setWan sub_3517C os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function sub_3517C of the file /goform/setWan. The manipulation of the argument Hostname leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6250RE7000RE6500RE9000
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8825
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 02:02
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto os command injection

A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8818
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-10 Aug, 2025 | 22:32
Updated-04 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setLan setDFSSetting os command injection

A vulnerability has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this issue is the function setDFSSetting of the file /goform/setLan. The manipulation of the argument lanNetmask/lanIp leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9244
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.30% / 53.11%
||
7 Day CHG~0.00%
Published-20 Aug, 2025 | 19:32
Updated-02 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 addStaticRoute os command injection

A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6300re9000_firmwarere6350re6500re6250_firmwarere7000re7000_firmwarere6250re6350_firmwarere9000re6300_firmwarere6500_firmwareRE7000RE9000RE6250RE6350RE6300RE6500
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-9575
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-28 Aug, 2025 | 18:02
Updated-04 Sep, 2025 | 18:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 upload.cgi cgiMain os command injection

A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE6500RE9000RE7000RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8827
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 03:02
Updated-04 Sep, 2025 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 RP_setBasicAuto um_inspect_cross_band os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-8823
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 46.49%
||
7 Day CHG~0.00%
Published-11 Aug, 2025 | 01:05
Updated-04 Sep, 2025 | 18:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 setDeviceName os command injection

A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re6350_firmwarere6300_firmwarere6500re9000re9000_firmwarere6350re6250re6300re6250_firmwarere7000_firmwarere6500_firmwarere7000RE6300RE6350RE7000RE9000RE6500RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5441
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.36%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 10:31
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 setDeviceURL os command injection

A vulnerability classified as critical was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function setDeviceURL of the file /goform/setDeviceURL. The manipulation of the argument DeviceURL leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5442
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.36%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 11:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_pingGatewayByBBS os command injection

A vulnerability, which was classified as critical, has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function RP_pingGatewayByBBS of the file /goform/RP_pingGatewayByBBS. The manipulation of the argument ip/nm/gw leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5440
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.11% / 77.82%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 10:00
Updated-02 Jul, 2025 | 18:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 NTP os command injection

A vulnerability classified as critical has been found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This affects the function NTP of the file /goform/NTP. The manipulation of the argument manual_year_select/manual_month_select/manual_day_select/manual_hour_select/manual_min_select/manual_sec_select leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5439
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.11% / 77.82%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 09:31
Updated-02 Jul, 2025 | 18:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 verifyFacebookLike os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been rated as critical. Affected by this issue is the function verifyFacebookLike of the file /goform/verifyFacebookLike. The manipulation of the argument uid/accessToken leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-re9000_firmwarere6250re7000re6300re6300_firmwarere7000_firmwarere6500_firmwarere9000re6350re6350_firmwarere6250_firmwarere6500RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-5446
Matching Score-6
Assigner-VulDB
ShareView Details
Matching Score-6
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.17% / 78.36%
||
7 Day CHG+0.14%
Published-02 Jun, 2025 | 13:00
Updated-02 Jun, 2025 | 17:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection

A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-RE7000RE6350RE9000RE6500RE6300RE6250
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-43973
Matching Score-6
Assigner-Trellix
ShareView Details
Matching Score-6
Assigner-Trellix
CVSS Score-7.2||HIGH
EPSS-1.79% / 82.47%
||
7 Day CHG~0.00%
Published-09 Jan, 2023 | 00:00
Updated-09 Apr, 2025 | 14:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary code execution in Linksys WRT54GL

An arbitrary code execution vulnerability exisits in Linksys WRT54GL Wireless-G Broadband Router with firmware <= 4.30.18.006. The Check_TSSI function within the httpd binary uses unvalidated user input in the construction of a system command. An authenticated attacker with administrator privileges can leverage this vulnerability over the network via a malicious POST request to /apply.cgi to execute arbitrary commands on the underlying Linux operating system as root.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wrt54glwrt54gl_firmwareWRT54GL Wireless-G Broadband Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-43971
Matching Score-6
Assigner-Trellix
ShareView Details
Matching Score-6
Assigner-Trellix
CVSS Score-7.2||HIGH
EPSS-1.62% / 81.54%
||
7 Day CHG~0.00%
Published-09 Jan, 2023 | 00:00
Updated-09 Apr, 2025 | 14:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary code execution in Linksys WUMC710

An arbitrary code exection vulnerability exists in Linksys WUMC710 Wireless-AC Universal Media Connector with firmware <= 1.0.02 (build3). The do_setNTP function within the httpd binary uses unvalidated user input in the construction of a system command. An authenticated attacker with administrator privileges can leverage this vulnerability over the network via a malicious GET or POST request to /setNTP.cgi to execute arbitrary commands on the underlying Linux operating system as root.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wumc710_firmwarewumc710Linksys WUMC710 Wireless-AC Universal Media Connector
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2013-3307
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-8.3||HIGH
EPSS-2.59% / 85.33%
||
7 Day CHG~0.00%
Published-11 Jul, 2025 | 00:00
Updated-15 Jul, 2025 | 13:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys E1000 devices through 2.1.02, E1200 devices before 2.0.05, and E3200 devices through 1.0.04 allow OS command injection via shell metacharacters in the apply.cgi ping_ip parameter on TCP port 52000.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-E1200E3200E1000
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-34037
Matching Score-6
Assigner-VulnCheck
ShareView Details
Matching Score-6
Assigner-VulnCheck
CVSS Score-10||CRITICAL
EPSS-79.62% / 99.06%
||
7 Day CHG~0.00%
Published-24 Jun, 2025 | 01:03
Updated-22 Nov, 2025 | 01:31
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys Routers E/WAG/WAP/WES/WET/WRT-Series

An OS command injection vulnerability exists in various models of E-Series Linksys routers via the /tmUnblock.cgi and /hndUnblock.cgi endpoints over HTTP on port 8080. The CGI scripts improperly process user-supplied input passed to the ttcp_ip parameter without sanitization, allowing unauthenticated attackers to inject shell commands. This vulnerability is exploited in the wild by the "TheMoon" worm to deploy a MIPS ELF payload, enabling arbitrary code execution on the router. This vulnerability may affect other Linksys products to include, but not limited to, WAG/WAP/WES/WET/WRT-series router models and Wireless-N access points and routers. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-06 UTC.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-E3000E4200E1550E1000 v1E2000E3200E2100L v1E2500 v1/v2E1200 v1E1500 v1E900 v1
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2022-38132
Matching Score-6
Assigner-24e70c8d-eeca-431d-8285-199a41b4014e
ShareView Details
Matching Score-6
Assigner-24e70c8d-eeca-431d-8285-199a41b4014e
CVSS Score-8.2||HIGH
EPSS-0.77% / 73.14%
||
7 Day CHG~0.00%
Published-23 Aug, 2022 | 23:16
Updated-16 Sep, 2024 | 22:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection vulnerability in Linksys MR8300 router while Registration to DDNS Service. By specifying username and password, an attacker connected to the router's web interface can execute arbitrary OS commands.

Command injection vulnerability in Linksys MR8300 router while Registration to DDNS Service. By specifying username and password, an attacker connected to the router's web interface can execute arbitrary OS commands. The username and password fields are not sanitized correctly and are used as URL construction arguments, allowing URL redirection to an arbitrary server, downloading an arbitrary script file, and eventually executing the file in the device. This issue affects: Linksys MR8300 Router 1.0.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-mr8300_firmwaremr8300MR8300 Router
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2017-17411
Matching Score-6
Assigner-Zero Day Initiative
ShareView Details
Matching Score-6
Assigner-Zero Day Initiative
CVSS Score-9.8||CRITICAL
EPSS-92.16% / 99.70%
||
7 Day CHG~0.00%
Published-21 Dec, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Linksys WVBR0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web management portal. The issue lies in the lack of proper validation of user data before executing a system call. An attacker could leverage this vulnerability to execute code with root privileges. Was ZDI-CAN-4892.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-wvbr0wvbr0_firmwareLinksys WVBR0
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2013-10058
Matching Score-6
Assigner-VulnCheck
ShareView Details
Matching Score-6
Assigner-VulnCheck
CVSS Score-8.6||HIGH
EPSS-46.60% / 97.59%
||
7 Day CHG~0.00%
Published-01 Aug, 2025 | 20:44
Updated-20 Nov, 2025 | 23:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Linksys Routers apply.cgi Remote Command Injection

An authenticated OS command injection vulnerability exists in various Linksys router models (tested on WRT160Nv2) running firmware version v2.0.03 via the apply.cgi endpoint. The web interface fails to properly sanitize user-supplied input passed to the ping_size parameter during diagnostic operations. An attacker with valid credentials can inject arbitrary shell commands, enabling remote code execution.

Action-Not Available
Vendor-Linksys Holdings, Inc.
Product-WRT160nv2
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-43130
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.09% / 77.64%
||
7 Day CHG~0.00%
Published-22 Sep, 2023 | 00:00
Updated-24 Sep, 2024 | 16:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-LINK DIR-806 1200M11AC wireless router DIR806A1_FW100CNb11 is vulnerable to command injection.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-806dir-806_firmwaren/adir-806_1200m11ac
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2020-11963
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.71% / 72.04%
||
7 Day CHG~0.00%
Published-21 Apr, 2020 | 12:04
Updated-04 Aug, 2024 | 11:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

IQrouter through 3.3.1, when unconfigured, has multiple remote code execution vulnerabilities in the web-panel because of Bash Shell Metacharacter Injection. Note: The vendor claims that this vulnerability can only occur on a brand-new network that, after initiating the forced initial configuration (which has a required step for setting a secure password on the system), makes this CVE invalid. This vulnerability is “true for any unconfigured release of OpenWRT, and true of many other new Linux distros prior to being configured for the first time”

Action-Not Available
Vendor-evenrouten/a
Product-iqrouter_firmwareiqroutern/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-43892
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.99% / 86.30%
||
7 Day CHG~0.00%
Published-02 Oct, 2023 | 00:00
Updated-04 Apr, 2025 | 21:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Netis N3Mv2-V1.0.1.865 was discovered to contain a command injection vulnerability via the Hostname parameter within the WAN settings. This vulnerability is exploited via a crafted payload.

Action-Not Available
Vendor-n/aNetis Systems Co., Ltd.
Product-n3m_firmwaren3mn/an3m_firmware
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-46007
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-9.41% / 92.64%
||
7 Day CHG~0.00%
Published-30 Mar, 2022 | 22:12
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

totolink a3100r V5.9c.4577 is vulnerable to os command injection. The backend of a page is executing the "ping" command, and the input field does not adequately filter special symbols. This can lead to command injection attacks.

Action-Not Available
Vendor-n/aTOTOLINK
Product-ar3100rar3100r_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-36287
Matching Score-4
Assigner-Dell
ShareView Details
Matching Score-4
Assigner-Dell
CVSS Score-7.3||HIGH
EPSS-2.11% / 83.85%
||
7 Day CHG~0.00%
Published-08 Apr, 2022 | 19:50
Updated-16 Sep, 2024 | 17:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Dell VNX2 for file version 8.1.21.266 and earlier, contain an unauthenticated remote code execution vulnerability which may lead unauthenticated users to execute commands on the system.

Action-Not Available
Vendor-Dell Inc.
Product-vnxe1600vnx5600vnx5400vnx5800vnx_vg10emc_unity_operating_environmentvnx5200vnx_vg50vnx7600vnx8000VNX2
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-1581
Matching Score-4
Assigner-Palo Alto Networks, Inc.
ShareView Details
Matching Score-4
Assigner-Palo Alto Networks, Inc.
CVSS Score-9.8||CRITICAL
EPSS-3.17% / 86.70%
||
7 Day CHG~0.00%
Published-23 Aug, 2019 | 17:06
Updated-17 Sep, 2024 | 00:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PAN-OS: Remote code execution vulnerability in the PAN-OS SSH device management interface

A remote code execution vulnerability in the PAN-OS SSH device management interface that can lead to unauthenticated remote users with network access to the SSH management interface gaining root access to PAN-OS. This issue affects PAN-OS 7.1 versions prior to 7.1.24-h1, 7.1.25; 8.0 versions prior to 8.0.19-h1, 8.0.20; 8.1 versions prior to 8.1.9-h4, 8.1.10; 9.0 versions prior to 9.0.3-h3, 9.0.4.

Action-Not Available
Vendor-Palo Alto Networks, Inc.
Product-pan-osPAN-OS
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-20
Improper Input Validation
CVE-2025-26074
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.15% / 35.02%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 00:00
Updated-30 Jun, 2025 | 19:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Orkes Conductor v3.21.11 allows remote attackers to execute arbitrary OS commands through unrestricted access to Java classes.

Action-Not Available
Vendor-n/a
Product-n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-13025
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-10.81% / 93.21%
||
7 Day CHG~0.00%
Published-02 Oct, 2019 | 14:54
Updated-04 Aug, 2024 | 23:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Compal CH7465LG CH7465LG-NCIP-6.12.18.24-5p8-NOSH devices have Incorrect Access Control because of Improper Input Validation. The attacker can send a maliciously modified POST (HTTP) request containing shell commands, which will be executed on the device, to an backend API endpoint of the cable modem.

Action-Not Available
Vendor-compaln/a
Product-ch7465lgch7465lg_firmwaren/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CWE ID-CWE-669
Incorrect Resource Transfer Between Spheres
CVE-2019-15310
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-11.93% / 93.61%
||
7 Day CHG~0.00%
Published-01 Jul, 2020 | 19:18
Updated-05 Aug, 2024 | 00:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered on various devices via the Linkplay firmware. There is WAN remote code execution without user interaction. An attacker could retrieve the AWS key from the firmware and obtain full control over Linkplay's AWS estate, including S3 buckets containing device firmware. When combined with an OS command injection vulnerability within the XML Parsing logic of the firmware update process, an attacker would be able to gain code execution on any device that attempted to update. Note that by default all devices tested had automatic updates enabled.

Action-Not Available
Vendor-linkplayn/a
Product-linkplayn/a
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2023-4410
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.11% / 77.83%
||
7 Day CHG~0.00%
Published-18 Aug, 2023 | 14:00
Updated-03 Jul, 2025 | 13:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TOTOLINK EX1200L setDiagnosisCfg os command injection

A vulnerability, which was classified as critical, was found in TOTOLINK EX1200L EN_V9.3.5u.6146_B20201023. This affects the function setDiagnosisCfg. The manipulation leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-237513 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-TOTOLINK
Product-ex1200l_firmwareex1200lEX1200L
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-15609
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-5.00% / 89.51%
||
7 Day CHG~0.00%
Published-28 Feb, 2020 | 19:30
Updated-05 Aug, 2024 | 00:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The kill-port-process package version < 2.2.0 is vulnerable to a Command Injection vulnerability.

Action-Not Available
Vendor-kill-port-process_projectn/a
Product-kill-port-processkill-port-process
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-25256
Matching Score-4
Assigner-Fortinet, Inc.
ShareView Details
Matching Score-4
Assigner-Fortinet, Inc.
CVSS Score-9.8||CRITICAL
EPSS-44.70% / 97.50%
||
7 Day CHG~0.00%
Published-12 Aug, 2025 | 18:59
Updated-26 Feb, 2026 | 17:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability [CWE-78] in Fortinet FortiSIEM version 7.3.0 through 7.3.1, 7.2.0 through 7.2.5, 7.1.0 through 7.1.7, 7.0.0 through 7.0.3 and before 6.7.9 allows an unauthenticated attacker to execute unauthorized code or commands via crafted CLI requests.

Action-Not Available
Vendor-Fortinet, Inc.
Product-fortisiemFortiSIEM
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-15598
Matching Score-4
Assigner-HackerOne
ShareView Details
Matching Score-4
Assigner-HackerOne
CVSS Score-9.8||CRITICAL
EPSS-3.75% / 87.80%
||
7 Day CHG~0.00%
Published-18 Dec, 2019 | 20:58
Updated-05 Aug, 2024 | 00:49
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Code Injection exists in treekill on Windows which allows a remote code execution when an attacker is able to control the input into the command.

Action-Not Available
Vendor-treekill_projectn/a
Product-treekilltreekill
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2019-12511
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 62.14%
||
7 Day CHG~0.00%
Published-24 Feb, 2020 | 18:16
Updated-04 Aug, 2024 | 23:24
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Root Command Injection via MAC Address in SOAP API

In NETGEAR Nighthawk X10-R9000 prior to 1.0.4.26, an attacker may execute arbitrary system commands as root by sending a specially-crafted MAC address to the "NETGEAR Genie" SOAP endpoint at AdvancedQoS:GetCurrentBandwidthByMAC. Although this requires QoS being enabled, advanced QoS being enabled, and a valid authentication JWT, additional vulnerabilities (CVE-2019-12510) allow an attacker to interact with the entire SOAP API without authentication. Additionally, DNS rebinding techniques may be used to exploit this vulnerability remotely. Exploiting this vulnerability is somewhat involved. The following limitations apply to the payload and must be overcome for successful exploitation: - No more than 17 characters may be used. - At least one colon must be included to prevent mangling. - A single-quote and meta-character must be used to break out of the existing command. - Parent command remnants after the injection point must be dealt with. - The payload must be in all-caps. Despite these limitations, it is still possible to gain access to an interactive root shell via this vulnerability. Since the web server assigns certain HTTP headers to environment variables with all-caps names, it is possible to insert a payload into one such header and reference the subsequent environment variable in the injection point.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-nighthawk_x10-r9000_firmwarenighthawk_x10-r9000n/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2021-46704
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-86.93% / 99.42%
||
7 Day CHG~0.00%
Published-06 Mar, 2022 | 06:23
Updated-04 Aug, 2024 | 05:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In GenieACS 1.2.x before 1.2.8, the UI interface API is vulnerable to unauthenticated OS command injection via the ping host argument (lib/ui/api.ts and lib/ping.ts). The vulnerability arises from insufficient input validation combined with a missing authorization check.

Action-Not Available
Vendor-genieacsn/a
Product-genieacsn/a
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • ...
  • 28
  • 29
  • Next
Details not found