An issue in Dolibarr ERP CRM v.17.0.1 and before allows a remote privileged attacker to execute arbitrary code via a crafted command/script.
A command injection vulnerability may be exploited after the admin's authentication in the VPN server configuration module on the TP-Link Archer BE230 v1.2. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420.
A vulnerability has been found in D-Link DIR-823X 250416. This affects the function sub_4211C8 of the file /goform/set_filtering. Such manipulation leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
Due to insufficient input parameter validation on the interface, authenticated users of certain HIKSEMI NAS products can execute arbitrary commands on the device by crafting specific messages.
A vulnerability was found in D-Link DCS-931L up to 1.13.0. This affects an unknown part of the file /goform/setSysAdmin. The manipulation of the argument AdminID results in os command injection. The attack can be executed remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.
A command injection vulnerability may be exploited after the admin's authentication via the configuration backup restoration function of the TP-Link Archer BE230 v1.2. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420.
Insecure file operations in HPE Aruba Networking Fabric Composer’s backup functionality could allow authenticated attackers to achieve remote code execution. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system.
Dell SmartFabric OS10 Software, versions prior to 10.5.6.12, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Command execution.
A command injection vulnerability may be exploited after the admin's authentication via the import of a crafted VPN client configuration file on the TP-Link Archer BE230 v1.2. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420.
A command injection vulnerability may be exploited after the admin's authentication in the cloud communication interface on the TP-Link Archer BE230 v1.2. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420.
Adobe Commerce versions 2.4.6-p1 (and earlier), 2.4.5-p3 (and earlier) and 2.4.4-p4 (and earlier) are affected by an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability that could lead to arbitrary code execution by an admin-privilege authenticated attacker. Exploitation of this issue does not require user interaction.
A vulnerability was identified in D-Link DIR-823X 250416. The impacted element is an unknown function of the file /goform/set_mac_clone. Such manipulation of the argument mac leads to os command injection. The attack may be performed from remote. The exploit is publicly available and might be used.
A vulnerability has been found in D-Link DIR-615 4.10. This affects an unknown part of the file adv_firewall.php of the component DMZ Host Feature. Such manipulation of the argument dmz_ipaddr leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was determined in D-Link DIR-823X 250416. The affected element is an unknown function of the file /goform/set_password. This manipulation of the argument http_passwd causes os command injection. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.
A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function sub_420618 of the file /goform/set_upnp. This manipulation of the argument upnp_enable causes os command injection. Remote exploitation of the attack is possible. The exploit has been made available to the public and could be used for attacks.
A vulnerability was determined in UTT HiPER 810 1.7.4-141218. The impacted element is the function sub_4407D4 of the file /goform/formReleaseConnect of the component rehttpd. Executing a manipulation of the argument Isp_Name can lead to command injection. The attack can be launched remotely. The exploit has been publicly disclosed and may be utilized.
A weakness has been identified in D-Link DIR-823X 250416. This vulnerability affects the function sub_420688 of the file /goform/set_qos. Executing a manipulation can lead to os command injection. The attack can be executed remotely. The exploit has been made available to the public and could be used for attacks.
MultiTech Conduit MTCDT-LVW2-24XX 1.4.17-ocea-13592 devices allow remote authenticated administrators to execute arbitrary OS commands by navigating to the Debug Options page and entering shell metacharacters in the interface JSON field of the ping function.
A vulnerability has been found in UTT HiPER 810 1.7.4-141218. This issue affects the function setSysAdm of the file /goform/formUser. The manipulation of the argument passwd1 leads to command injection. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in DCN DCME-320 up to 20260121. Impacted is the function apply_config of the file /function/system/basic/bridge_cfg.php of the component Web Management Backend. Performing a manipulation of the argument ip_list results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was determined in D-Link DIR-823X 250416. Affected by this issue is the function sub_424D20 of the file /goform/set_ipv6. Executing a manipulation can lead to os command injection. It is possible to launch the attack remotely. The exploit has been publicly disclosed and may be utilized.
A vulnerability was identified in D-Link DIR-600 up to 2.15WWb02. This vulnerability affects unknown code of the file ssdp.cgi. Such manipulation of the argument HTTP_ST/REMOTE_ADDR/REMOTE_PORT/SERVER_ID leads to command injection. The attack may be launched remotely. The exploit is publicly available and might be used. This vulnerability only affects products that are no longer supported by the maintainer.
A vulnerability was found in D-Link DIR-615 4.10. This vulnerability affects unknown code of the file adv_routing.php of the component Web Configuration Interface. Performing a manipulation of the argument dest_ip/ submask/ gw results in os command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.
A post-authentication command injection vulnerability in the TR-369 certificate download CGI program of the Zyxel VMG3625-T50B firmware versions through 5.50(ABPM.9.7)C0 could allow an authenticated attacker with administrator privileges to execute operating system (OS) commands on an affected device.
Dell EMC CloudLink 7.1 and all prior versions contain an OS command injection Vulnerability. A remote high privileged attacker, may potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. This vulnerability is considered critical as it may be leveraged to completely compromise the vulnerable application as well as the underlying operating system. Dell recommends customers to upgrade at the earliest opportunity.
A vulnerability has been found in bastillion-io Bastillion up to 4.0.1. This vulnerability affects unknown code of the file src/main/java/io/bastillion/manage/control/AuthKeysKtrl.java of the component Public Key Management System. Such manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A weakness has been identified in D-Link DCS700l 1.03.09. Affected is an unknown function of the file /setDayNightMode of the component Web Form Handler. Executing a manipulation of the argument LightSensorControl can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.
A command injection vulnerability is present in Aruba Instant that permits an authenticated administrative user to execute arbitrary commands on the underlying operating system. A malicious administrator could use this ability to install backdoors or change system configuration in a way that would not be logged. Workaround: None. Resolution: Fixed in Aruba Instant 4.2.4.12, 6.5.4.11, 8.3.0.6, and 8.4.0.0
A security vulnerability has been detected in D-Link DI-500WF 14.04.10A1T. The impacted element is an unknown function of the file /version_upgrade.asp of the component jhttpd. The manipulation of the argument path leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
A post-authentication command injection vulnerability in Zyxel ATP series firmware versions from V4.32 through V5.40, USG FLEX series firmware versions from V4.50 through V5.40, USG FLEX 50(W) series firmware versions from V4.16 through V5.40, and USG20(W)-VPN series firmware versions from V4.16 through V5.40 could allow an authenticated attacker with administrator privileges to execute operating system (OS) commands on the affected device by passing a crafted string as an argument to a CLI command.
The files_antivirus component before 1.0.0 for ownCloud allows OS Command Injection via the administration settings.
D-Link DCH-M225 1.05b01 and earlier devices allow remote authenticated admins to execute arbitrary OS commands via shell metacharacters in the media renderer name.
An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_normal_mode` parameter.
An exploitable operating system command injection exists in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04). Specially crafted entries to network configuration information can cause execution of arbitrary system commands, resulting in full control of the device. An attacker can send an authenticated HTTP request to trigger this vulnerability. Data entered into the 'Domain Name' input field through the web portal is submitted to apply.cgi as the value to the 'wan_domain' POST parameter. The wan_domain data goes through the nvram_set process described above. When the 'preinit' binary receives the SIGHUP signal it enters a code path that calls a function named 'set_host_domain_name' from its libshared.so shared object.
A vulnerability in the web-based management interface of Cisco AsyncOS Software for Cisco Secure Email Gateway and Cisco Secure Web Appliance could allow an authenticated, remote attacker to perform command injection attacks against an affected device. The attacker must authenticate with valid administrator credentials. This vulnerability is due to insufficient validation of XML configuration files by an affected device. An attacker could exploit this vulnerability by uploading a crafted XML configuration file. A successful exploit could allow the attacker to inject commands to the underlying operating system with root privileges.
ChurchCRM is an open-source church management system. In versions prior to 6.5.3, the Database Restore functionality does not validate the content or file extension of uploaded files. As a result, an attacker can upload a web shell file and subsequently upload a .htaccess file to enable direct access to it. Once accessed, the uploaded web shell allows remote code execution (RCE) on the server. Version 6.5.3 fixes the issue.
Array Networks ArrayOS AG before 9.4.5.9 allows command injection, as exploited in the wild in August through December 2025.
An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_battery_mode` POST parameter.
A command injection vulnerability may be exploited after the admin's authentication in the VPN Connection Service on the Archer BE230 v1.2. Successful exploitation could allow an attacker to gain full administrative control of the device, resulting in severe compromise of configuration integrity, network security, and service availability. This CVE covers one of multiple distinct OS command injection issues identified across separate code paths. Although similar in nature, each instance is tracked under a unique CVE ID. This issue affects Archer BE230 v1.2 < 1.2.4 Build 20251218 rel.70420.
A vulnerability was found in D-Link DCS-931L up to 1.13.0. Impacted is the function doSystem of the file /setSystemAdmin. Performing a manipulation of the argument AdminID results in command injection. The attack may be initiated remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.
Devices in the Linksys ESeries line of routers (Linksys E1200 Firmware Version 2.0.09 and Linksys E2500 Firmware Version 3.0.04) are susceptible to OS command injection vulnerabilities due to improper filtering of data passed to and retrieved from NVRAM. Data entered into the 'Router Name' input field through the web portal is submitted to apply.cgi as the value to the 'machine_name' POST parameter. When the 'preinit' binary receives the SIGHUP signal, it enters a code path that continues until it reaches offset 0x0042B5C4 in the 'start_lltd' function. Within the 'start_lltd' function, a 'nvram_get' call is used to obtain the value of the user-controlled 'machine_name' NVRAM entry. This value is then entered directly into a command intended to write the host name to a file and subsequently executed.
An exploitable command injection vulnerability exists in the way Netgate pfSense CE 2.4.4-RELEASE processes the parameters of a specific POST request. The attacker can exploit this and gain the ability to execute arbitrary commands on the system. An attacker needs to be able to send authenticated POST requests to the administration web interface. Command injection is possible in the `powerd_ac_mode` POST parameter parameter.
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340/D440 provided by Y'S corporation. A user with an administrative privilege who logged in to the web management page of the affected product may execute an arbitrary OS command.
OS command injection in Ivanti Endpoint Manager Mobile (EPMM) before version 12.5.0.2,12.4.0.3 and 12.3.0.3 allows a remote authenticated attacker with high privileges to achieve remote code execution
A vulnerability was detected in D-Link DIR-605 202WWB03. Affected by this issue is some unknown functionality of the component Firmware Update Service. Performing manipulation results in command injection. The attack can be initiated remotely. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
A security flaw has been discovered in D-Link DIR-823X 250416. This vulnerability affects unknown code of the file /goform/set_ac_server of the component Web Management Interface. The manipulation of the argument ac_server results in os command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
A flaw has been found in TRENDnet TEW-811DRU 1.0.2.0. This affects the function setDeviceURL of the file uapply.cgi of the component httpd . This manipulation of the argument DeviceURL causes os command injection. The attack can be initiated remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A weakness has been identified in D-Link DIR-823X 250416. This impacts an unknown function of the file /goform/set_language. Executing a manipulation of the argument langSelection can lead to os command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
A weakness has been identified in UTT 进取 521G 3.1.1-190816. Affected by this issue is the function doSystem of the file /goform/setSysAdm. Executing a manipulation of the argument passwd1 can lead to command injection. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.
A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.