Xvfb of SAP Business Objects Business Intelligence Platform, versions - 4.2, 4.3, platform on Unix does not perform any authentication checks for functionalities that require user identity.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
KuWFi CPF908-CP5 WEB5.0_LCD_20210125 devices have multiple unauthenticated access control vulnerabilities within goform/goform_set_cmd_process and goform/goform_get_cmd_process. These allow an unauthenticated attacker to retrieve sensitive information (including the device admin username and password), modify critical device settings, and send arbitrary SMS messages.
Missing authentication vulnerability in TCMAN GIM v11. This allows an unauthenticated attacker to access the resources /frmGestionUser.aspx/GetData, /frmGestionUser.aspx/updateUser and /frmGestionUser.aspx/DeleteUser.
The Quantenna Wi-Fi chips ship with an unauthenticated telnet interface by default. This is an instance of CWE-306, "Missing Authentication for Critical Function," and is estimated as a CVSS 9.1 (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N). This issue affects Quantenna Wi-Fi chipset through version 8.0.0.28 of the latest SDK, and appears to be unpatched at the time of this CVE record's first publishing, though the vendor has released a best practices guide for implementors of this chipset.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) expose four admin routes – /admin/hp/cert_upload, /admin/hp/cert_delete, /admin/certs/ca, and /admin/certs/serviceclients/{scid} – without any authentication check. The routes are defined in the /var/www/app/routes/web.php file inside the printercloud/pi Docker container and are handled by the HPCertificateController class, which performs no user validation. An unauthenticated attacker can therefore upload a new TLS/SSL certificate replacing the trusted root used by the appliance, delete an existing certificate causing immediate loss of trust for services that rely on it, or download any stored CA or client certificate via the service‑clients endpoint which also suffers an IDOR that allows enumeration of all client IDs. This vulnerability has been identified by the vendor as: V-2024-028 — Unauthenticated Admin APIs Used to Modify SSL Certificates.
IBM Planning Analytics Local 2.0 and 2.1 connects to a MongoDB server. MongoDB, a document-oriented database system, is listening on the remote port, and it is configured to allow connections without password authentication. A remote attacker can gain unauthorized access to the database. IBM X-Force ID: 292420.
An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected.
Broken Access Control in User Authentication in Avaya Scopia Pathfinder 10 and 20 PTS version 8.3.7.0.4 allows remote unauthenticated attackers to bypass the login page, access sensitive information, and reset user passwords via URL modification.
IBM Planning Analytics Local 2.0 connects to a Redis server. The Redis server, an in-memory data structure store, running on the remote host is not protected by password authentication. A remote attacker can exploit this to gain unauthorized access to the server. IBM X-Force ID: 186401.
The Web CGI Script on ZyXEL LTE4506-M606 V1.00(ABDO.2)C0 devices does not require authentication, which allows remote unauthenticated attackers (via crafted JSON action data to /cgi-bin/gui.cgi) to use all features provided by the router. Examples: change the router password, retrieve the Wi-Fi passphrase, send an SMS message, or modify the IP forwarding to access the internal network.
The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication.
An issue discovered in Axigen Mail Server 10.3.x before 10.3.1.27 and 10.3.2.x before 10.3.3.1 allows unauthenticated attackers to submit a setAdminPassword operation request, subsequently setting a new arbitrary password for the admin account.
Missing Authentication for Critical Function in temi Robox OS prior to 120, temi Android app up to 1.3.7931 allows remote attackers to receive and answer calls intended for another temi user. Answering the call this way grants motor control of the temi in addition to audio/video via unspecified vectors.
Affected versions of Smartstore have a missing WebApi Authentication attribute. This vulnerability affects Smartstore shops in version 4.0.0 & 4.0.1 which have installed and activated the Web API plugin. Users of Smartstore 4.0.0 and 4.0.1 must merge their repository with 4.0.x or overwrite the file SmartStore.Web.Framework in the */bin* directory of the deployed shop with this file. As a workaround without updating uninstall the Web API plugin to close this vulnerability.
openSIS through 7.4 has Incorrect Access Control.
Flag Forge is a Capture The Flag (CTF) platform. Starting in version 2.0.0 and prior to version 2.3.2, the `/api/admin/badge-templates` (GET) and `/api/admin/badge-templates/create` (POST) endpoints previously allowed access without authentication or authorization. This could have enabled unauthorized users to retrieve all badge templates and sensitive metadata (createdBy, createdAt, updatedAt) and/or create arbitrary badge templates in the database. This could lead to data exposure, database pollution, or abuse of the badge system. The issue has been fixed in FlagForge v2.3.2. GET, POST, UPDATE, and DELETE endpoints now require authentication. Authorization checks ensure only admins can access and modify badge templates. No reliable workarounds are available.