Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-38707

Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-28 May, 2026 | 00:00
Updated At-28 May, 2026 | 17:40
Rejected At-
Credits

A command injection vulnerability exists in the IPSec VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:28 May, 2026 | 00:00
Updated At:28 May, 2026 | 17:40
Rejected At:
▼CVE Numbering Authority (CNA)

A command injection vulnerability exists in the IPSec VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
https://www.inhand.com/wp-content/uploads/InHand-PSA-2026-05_EN.pdf
N/A
Hyperlink: https://www.inhand.com/wp-content/uploads/InHand-PSA-2026-05_EN.pdf
Resource: N/A
▼Authorized Data Publishers (ADP)
CISA ADP Vulnrichment
Affected Products
Problem Types
TypeCWE IDDescription
CWECWE-77CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Type: CWE
CWE ID: CWE-77
Description: CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
Metrics
VersionBase scoreBase severityVector
3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:28 May, 2026 | 17:16
Updated At:29 May, 2026 | 14:08

A command injection vulnerability exists in the IPSec VPN feature of InHand Networks IR302 firmware V3.5.108, IR305 firmware V1.0.118, IR315 firmware V1.0.118, IR615 firmware V1.0.118, and earlier versions. Attackers can exploit this vulnerability to obtain ROOT privileges on remote target devices.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary3.19.8CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 3.1
Base score: 9.8
Base severity: CRITICAL
Vector:
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CPE Matches

InHand Networks, Inc.
inhandnetworks
>>ir315_firmware>>Versions before 1.0.121(exclusive)
cpe:2.3:o:inhandnetworks:ir315_firmware:*:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir315>>-
cpe:2.3:h:inhandnetworks:ir315:-:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir302_firmware>>Versions before 3.5.112(exclusive)
cpe:2.3:o:inhandnetworks:ir302_firmware:*:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir302>>-
cpe:2.3:h:inhandnetworks:ir302:-:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir615_firmware>>Versions before 1.0.121(exclusive)
cpe:2.3:o:inhandnetworks:ir615_firmware:*:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir615>>-
cpe:2.3:h:inhandnetworks:ir615:-:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir305_firmware>>Versions before 1.0.121(exclusive)
cpe:2.3:o:inhandnetworks:ir305_firmware:*:*:*:*:*:*:*:*
InHand Networks, Inc.
inhandnetworks
>>ir305>>-
cpe:2.3:h:inhandnetworks:ir305:-:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-77Secondary134c704f-9b21-4f2e-91b3-4a467353bcc0
CWE ID: CWE-77
Type: Secondary
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://www.inhand.com/wp-content/uploads/InHand-PSA-2026-05_EN.pdfcve@mitre.org
Vendor Advisory
Hyperlink: https://www.inhand.com/wp-content/uploads/InHand-PSA-2026-05_EN.pdf
Source: cve@mitre.org
Resource:
Vendor Advisory

Change History

0
Information is not available yet

Similar CVEs

1064Records found

CVE-2020-14505
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-3.00% / 86.91%
||
7 Day CHG~0.00%
Published-15 Jul, 2020 | 01:59
Updated-04 Aug, 2024 | 12:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Advantech iView, versions 5.6 and prior, has an improper neutralization of special elements used in a command (“command injection”) vulnerability. Successful exploitation of this vulnerability may allow an attacker to send a HTTP GET or POST request that creates a command string without any validation. The attacker may then remotely execute code.

Action-Not Available
Vendor-n/aAdvantech (Advantech Co., Ltd.)
Product-iviewAdvantech iView
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2021-45612
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-0.60% / 70.05%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:36
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20rax50r6900p_firmwareex7500_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80ex7500xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45738
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-25.81% / 96.39%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK X5000R v9.1.0u.6118_B20201102 was discovered to contain a command injection vulnerability in the function UploadFirmwareFile. This vulnerability allows attackers to execute arbitrary commands via the parameter FileName.

Action-Not Available
Vendor-n/aTOTOLINK
Product-x5000r_firmwarex5000rn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45985
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-34.67% / 97.12%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain a command injection vulnerability via the bs_SetSSIDHide function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45627
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.62% / 82.29%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:33
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rbs850cbr750rbs850_firmwarerbr850rbk852rbk852_firmwarecbr750_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45616
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-1.53% / 81.76%
||
7 Day CHG~0.00%
Published-26 Dec, 2021 | 00:35
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-rax15lax20rax50r6900p_firmwarer7960prax45rs400r7000_firmwarerax40v2_firmwarerax20r7900prax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarerbk752_firmwarer7900_firmwarerbk852r7900p_firmwarelax20_firmwarems60r8000_firmwarexr1000_firmwarerax80xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarerbr750_firmwarer7000prax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerax45_firmwarerbk852_firmwarerbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45876
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.34% / 89.20%
||
7 Day CHG~0.00%
Published-21 Mar, 2022 | 10:27
Updated-04 Aug, 2024 | 04:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple versions of GARO Wallbox GLB/GTB/GTC are affected by unauthenticated command injection. The url parameter of the function module downloadAndUpdate is vulnerable to an command Injection. Unfiltered user input is used to generate code which then gets executed when downloading new firmware.

Action-Not Available
Vendor-garon/a
Product-wallbox_gtbwallbox_glbwallbox_glb_firmwarewallbox_gtb_firmwarewallbox_gtc_firmwarewallbox_gtcn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45988
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the cmd parameter in the bs_SetCmd function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-ac1900_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-ac1900bl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44881
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-8.90% / 92.78%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link device DIR_882 DIR_882_FW1.30B06_Hotfix_02 was discovered to contain a command injection vulnerability in the twsystem function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-882_firmwaredir-882n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45984
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9, BL-AC1900 V1.0.2, BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 V1.0.5, BL-LTE300 V1.2.3, BL-F1200_AT1 V1.0.0, BL-X26_AC8 V1.2.8, BLAC450M_AE4 V4.0.0 and BL-X26_DA3 V1.2.7 were discovered to contain a command injection vulnerability via the routepwd parameter in the sub_45B238 function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1bl-x26_da3_firmwarebl-wr9000_firmwarebl-x10_ac8_firmwarebl-x10_ac8bl-x26_ac8_firmwarebl-wr9000bl-lte300_firmwarebl-ac1900_firmwarebl-x26_ac8bl-ac2100_az3_firmwarebl-ac1900bl-f1200_at1_firmwarebl-ac2100_az3blac450m_ae4blac450m_ae4_firmwarebl-lte300bl-x26_da3n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44620
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.92% / 88.62%
||
7 Day CHG~0.00%
Published-11 Mar, 2022 | 15:54
Updated-04 Aug, 2024 | 04:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exits in TOTOLINK A3100R <=V4.1.2cu.5050_B20200504 in adm/ntm.asp via the hosTime parameters.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a3100ra3100r_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45987
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-13 Jun, 2025 | 00:00
Updated-10 Jul, 2025 | 12:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Blink routers BL-WR9000 V2.4.9 , BL-AC2100_AZ3 V1.0.4, BL-X10_AC8 v1.0.5 , BL-LTE300 v1.2.3, BL-F1200_AT1 v1.0.0, BL-X26_AC8 v1.2.8, BLAC450M_AE4 v4.0.0 and BL-X26_DA3 v1.2.7 were discovered to contain multiple command injection vulnerabilities via the dns1 and dns2 parameters in the bs_SetDNSInfo function.

Action-Not Available
Vendor-b-linkn/a
Product-bl-f1200_at1_firmwarebl-ac2100_az3bl-f1200_at1bl-wr9000_firmwareblac450m_ae4bl-x26_da3_firmwarebl-x26_ac8_firmwarebl-wr9000blac450m_ae4_firmwarebl-lte300bl-lte300_firmwarebl-x26_da3bl-x26_ac8bl-ac2100_az3_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44084
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-2.05% / 84.28%
||
7 Day CHG~0.00%
Published-20 May, 2025 | 00:00
Updated-30 May, 2025 | 16:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-link DI-8100 16.07.26A1 is vulnerable to Command Injection. An attacker can exploit this vulnerability by crafting specific HTTP requests, triggering the command execution flaw and gaining the highest privilege shell access to the firmware system.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-di-8100g_firmwaredi-8100n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4454
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 77.00%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L wake_on_lan command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been declared as critical. This vulnerability affects the function wake_on_lan. The manipulation of the argument mac leads to command injection. The attack can be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45487
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-8.16% / 92.39%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys E5600 v1.1.0.26 was discovered to contain a command injection vulnerability in the runtime.InternetConnection function.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e5600e5600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-44868
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.04% / 90.96%
||
7 Day CHG-3.96%
Published-02 May, 2025 | 00:00
Updated-13 Jun, 2025 | 13:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Wavlink WL-WN530H4 20220801 was found to contain a command injection vulnerability in the ping_test function of the adm.cgi via the pingIp parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aWAVLINK Technology Ltd.
Product-wl-wn530h4wl-wn530h4_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4453
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 77.00%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 02:00
Updated-13 May, 2025 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSysCmd command injection

A vulnerability was found in D-Link DIR-619L 2.04B04. It has been classified as critical. This affects the function formSysCmd. The manipulation of the argument sysCmd leads to command injection. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45489
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-8.11% / 92.37%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys E5600 v1.1.0.26 was discovered to contain a command injection vulnerability in the runtime.ddnsStatus DynDNS function via the hostname parameter.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e5600e5600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4357
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.1||MEDIUM
EPSS-7.90% / 92.24%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 13:31
Updated-25 Aug, 2025 | 02:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Tenda RX3 telnet command injection

A vulnerability was found in Tenda RX3 16.03.13.11_multi. It has been rated as critical. This issue affects some unknown processing of the file /goform/telnet. The manipulation leads to command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-Tenda Technology Co., Ltd.
Product-rx3_firmwarerx3RX3
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45492
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-6.14% / 91.04%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Netgear EX8000 V1.0.0.126 is vulnerable to Command Injection via the Iface parameter in the action_wireless function.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-ex8000_firmwareex8000n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4443
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.74% / 83.00%
||
7 Day CHG~0.00%
Published-08 May, 2025 | 23:31
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L sub_454F2C command injection

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been rated as critical. This issue affects the function sub_454F2C. The manipulation of the argument sysCmd leads to command injection. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45456
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-34.87% / 97.14%
||
7 Day CHG~0.00%
Published-06 Jan, 2022 | 12:35
Updated-04 Aug, 2024 | 04:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection

Apache kylin checks the legitimacy of the project before executing some commands with the project name passed in by the user. There is a mismatch between what is being checked and what is being used as the shell command argument in DiagnosisService. This may cause an illegal project name to pass the check and perform the following steps, resulting in a command injection vulnerability. This issue affects Apache Kylin 4.0.0.

Action-Not Available
Vendor-The Apache Software Foundation
Product-kylinApache Kylin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45490
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-6.5||MEDIUM
EPSS-8.11% / 92.37%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys E5600 v1.1.0.26 was discovered to contain a command injection vulnerability in the runtime.ddnsStatus DynDNS function via the password parameter.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e5600e5600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45491
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-13.30% / 94.35%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 00:00
Updated-13 May, 2025 | 20:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Linksys E5600 v1.1.0.26 was discovered to contain a command injection vulnerability in the runtime.ddnsStatus DynDNS function via the username parameter.

Action-Not Available
Vendor-n/aLinksys Holdings, Inc.
Product-e5600e5600_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-43843
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.9||HIGH
EPSS-2.31% / 85.19%
||
7 Day CHG+0.98%
Published-05 May, 2025 | 17:09
Updated-01 Aug, 2025 | 16:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GHSL-2025-013_Retrieval-based-Voice-Conversion-WebUI

Retrieval-based-Voice-Conversion-WebUI is a voice changing framework based on VITS. Versions 2.2.231006 and prior are vulnerable to command injection. The variables exp_dir1, np7 and f0method8 take user input and pass it into the extract_f0_feature function, which concatenates them into a command that is run on the server. This can lead to arbitrary command execution. As of time of publication, no known patches exist.

Action-Not Available
Vendor-rvc-projectRVC-Project
Product-retrieval-based-voice-conversion-webuiRetrieval-based-Voice-Conversion-WebUI
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-26093
Matching Score-4
Assigner-Nozomi Networks Inc.
ShareView Details
Matching Score-4
Assigner-Nozomi Networks Inc.
CVSS Score-8.7||HIGH
EPSS-0.39% / 60.51%
||
7 Day CHG~0.00%
Published-20 Feb, 2026 | 16:49
Updated-27 Feb, 2026 | 17:08
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Improper Neutralization of Special Elements used in a Command ('Command Injection') in Owl opds

Improper Neutralization of Special Elements used in a Command ('Command Injection') in Owl opds 2.2.0.4 allows Command Injection via a crafted network request.

Action-Not Available
Vendor-owlcyberdefenseOwl
Product-opds-talonopds-100opds-1000opds
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45042
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-16.48% / 95.06%
||
7 Day CHG~0.00%
Published-05 May, 2025 | 00:00
Updated-07 May, 2025 | 16:39
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9ac9_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2025-44877
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-6.87% / 91.60%
||
7 Day CHG-7.09%
Published-02 May, 2025 | 00:00
Updated-27 May, 2025 | 14:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via the usbname parameter. This vulnerability allows attackers to execute arbitrary commands via a crafted request.

Action-Not Available
Vendor-n/aTenda Technology Co., Ltd.
Product-ac9_firmwareac9n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4445
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.96% / 77.00%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:00
Updated-13 May, 2025 | 20:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L wake_on_lan command injection

A vulnerability classified as critical has been found in D-Link DIR-605L 2.13B01. Affected is the function wake_on_lan. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605ldir-605l_firmwareDIR-605L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-44880
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-17.07% / 95.16%
||
7 Day CHG~0.00%
Published-04 Feb, 2022 | 01:34
Updated-04 Aug, 2024 | 04:32
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

D-Link devices DIR_878 DIR_878_FW1.30B08_Hotfix_02 and DIR_882 DIR_882_FW1.30B06_Hotfix_02 were discovered to contain a command injection vulnerability in the system function. This vulnerability allows attackers to execute arbitrary commands via a crafted HNAP1 POST request.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-878dir-878_firmwaredir-882dir-882_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-43844
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.9||HIGH
EPSS-3.67% / 88.21%
||
7 Day CHG+1.80%
Published-05 May, 2025 | 17:11
Updated-01 Aug, 2025 | 16:54
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
GHSL-2025-014_Retrieval-based-Voice-Conversion-WebUI

Retrieval-based-Voice-Conversion-WebUI is a voice changing framework based on VITS. Versions 2.2.231006 and prior are vulnerable to command injection. The variables exp_dir1, among others, take user input and pass it to the click_train function, which concatenates them into a command that is run on the server. This can lead to arbitrary command execution. As of time of publication, no known patches exist.

Action-Not Available
Vendor-rvc-projectRVC-Project
Product-retrieval-based-voice-conversion-webuiRetrieval-based-Voice-Conversion-WebUI
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45931
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-4.71% / 89.65%
||
7 Day CHG~0.00%
Published-30 Jun, 2025 | 00:00
Updated-08 Jul, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue D-Link DIR-816-A2 DIR-816A2_FWv1.10CNB05_R1B011D88210 allows a remote attacker to execute arbitrary code via system() function in the bin/goahead file

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dir-816dir-816_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-45800
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-1.09% / 78.45%
||
7 Day CHG-0.38%
Published-02 May, 2025 | 00:00
Updated-04 Jun, 2025 | 17:26
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

TOTOLINK A950RG V4.1.2cu.5204_B20210112 contains a command execution vulnerability in the setDeviceName interface of the /lib/cste_modules/global.so library, specifically in the processing of the deviceMac parameter.

Action-Not Available
Vendor-n/aTOTOLINK
Product-a950rg_firmwarea950rgn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43319
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-73.76% / 98.84%
||
7 Day CHG~0.00%
Published-30 Nov, 2021 | 18:44
Updated-04 Aug, 2024 | 03:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Zoho ManageEngine Network Configuration Manager before 125488 is vulnerable to command injection due to improper validation in the Ping functionality.

Action-Not Available
Vendor-n/aZoho Corporation Pvt. Ltd.
Product-manageengine_network_configuration_managern/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-50089
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.13% / 87.19%
||
7 Day CHG~0.00%
Published-15 Dec, 2023 | 00:00
Updated-26 Nov, 2024 | 15:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Command Injection vulnerability exists in NETGEAR WNR2000v4 version 1.0.0.70. When using HTTP for SOAP authentication, command execution occurs during the process after successful authentication.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-wnr2000wnr2000_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4340
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-2.78% / 86.44%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 08:00
Updated-13 May, 2025 | 20:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-890L/DIR-806A1 soap.cgi sub_175C8 command injection

A vulnerability classified as critical has been found in D-Link DIR-890L and DIR-806A1 up to 100CNb11/108B03. Affected is the function sub_175C8 of the file /htdocs/soap.cgi. The manipulation leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-806_firmwaredir-890ldir-806dir-890l_firmwareDIR-806A1DIR-890L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-43012
Matching Score-4
Assigner-JetBrains s.r.o.
ShareView Details
Matching Score-4
Assigner-JetBrains s.r.o.
CVSS Score-8.3||HIGH
EPSS-0.01% / 1.54%
||
7 Day CHG~0.00%
Published-17 Apr, 2025 | 15:56
Updated-26 Feb, 2026 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In JetBrains Toolbox App before 2.6 command injection in SSH plugin was possible

Action-Not Available
Vendor-JetBrains s.r.o.
Product-toolboxToolbox App
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-42740
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-9.04% / 92.85%
||
7 Day CHG~0.00%
Published-21 Oct, 2021 | 14:46
Updated-04 Aug, 2024 | 03:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The shell-quote package before 1.7.3 for Node.js allows command injection. An attacker can inject unescaped shell metacharacters through a regex designed to support Windows drive letters. If the output of this package is passed to a real shell as a quoted argument to a command with exec(), an attacker can inject arbitrary commands. This is because the Windows drive letter regex character class is {A-z] instead of the correct {A-Za-z]. Several shell metacharacters exist in the space between capital letter Z and lower case letter a, such as the backtick character.

Action-Not Available
Vendor-shell-quote_projectn/a
Product-shell-quoten/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43118
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-32.08% / 96.95%
||
7 Day CHG~0.00%
Published-29 Mar, 2022 | 19:37
Updated-04 Aug, 2024 | 03:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Remote Command Injection vulnerability exists in DrayTek Vigor 2960 1.5.1.3, DrayTek Vigor 3900 1.5.1.3, and DrayTek Vigor 300B 1.5.1.3 via a crafted HTTP message containing malformed QUERY STRING in mainfunction.cgi, which could let a remote malicious user execute arbitrary code.

Action-Not Available
Vendor-n/aDrayTek Corp.
Product-vigor300b_firmwarevigor3900vigor300bvigor2960_firmwarevigor3900_firmwarevigor2960n/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-4121
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-1.63% / 82.38%
||
7 Day CHG-0.18%
Published-30 Apr, 2025 | 14:00
Updated-13 May, 2025 | 20:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Netgear JWNR2000v2 cmd_wireless command injection

A vulnerability was found in Netgear JWNR2000v2 1.0.0.11. It has been declared as critical. Affected by this vulnerability is the function cmd_wireless. The manipulation of the argument host leads to command injection. The attack can be launched remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-NETGEAR, Inc.
Product-jwnr2000v2_firmwarejwnr2000v2JWNR2000v2
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-43113
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.47% / 87.86%
||
7 Day CHG~0.00%
Published-15 Dec, 2021 | 00:00
Updated-25 Feb, 2026 | 18:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

iTextPDF in iText 7 and up to (excluding 4.4.13.3) 7.1.17 allows command injection via a CompareTool filename that is mishandled on the gs (aka Ghostscript) command line in GhostscriptHelper.java.

Action-Not Available
Vendor-itextpdfn/aDebian GNU/Linux
Product-itextdebian_linuxn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2019-10095
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-9.8||CRITICAL
EPSS-3.02% / 86.95%
||
7 Day CHG~0.00%
Published-02 Sep, 2021 | 00:00
Updated-04 Aug, 2024 | 22:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
bash command injection in spark interpreter

bash command injection vulnerability in Apache Zeppelin allows an attacker to inject system commands into Spark interpreter settings. This issue affects Apache Zeppelin Apache Zeppelin version 0.9.0 and prior versions.

Action-Not Available
Vendor-The Apache Software Foundation
Product-zeppelinApache Zeppelin
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-45622
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.6||CRITICAL
EPSS-2.89% / 86.67%
||
7 Day CHG+0.22%
Published-26 Dec, 2021 | 00:34
Updated-04 Aug, 2024 | 04:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-cbr40_firmwareeax80rax15lax20r6400_firmwarerax50r6900p_firmwareex7500_firmwarerax45r7960prs400r7000_firmwarerax40v2_firmwareeax80_firmwarer6700v3rax20r6700v3_firmwarer7900prax20_firmwareeax20_firmwaremr60rax35v2rax43_firmwarerax40v2cbr750r6400v2rbs850_firmwarerbr850r7000rax43rax80_firmwarecbr750_firmwarecbr40rbk752_firmwarer7900_firmwarerbk852r7900p_firmwarems60lax20_firmwarer8000_firmwarexr1000_firmwarerax80ex7500xr1000rs400_firmwarer8000rax75mk62r6900pr7900r8000prbs850ms60_firmwarerbr750r8000p_firmwarer7850rax200r7000p_firmwarerax200_firmwarerbs750_firmwaremk62_firmwarer7850_firmwaremr60_firmwarexr300rbr750_firmwareeax20r7000pr6400v2_firmwarexr300_firmwarerax35v2_firmwarerbk752rbs750r7960p_firmwarerax15_firmwarerax75_firmwarerax50_firmwarerbk852_firmwarerax45_firmwarer6400rbr850_firmwaren/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41744
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.53% / 87.97%
||
7 Day CHG~0.00%
Published-22 Oct, 2021 | 11:40
Updated-04 Aug, 2024 | 03:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

All versions of yongyou PLM are affected by a command injection issue. UFIDA PLM (Product Life Cycle Management) is a strategic management method. It applies a series of enterprise application systems to support the entire process from conceptual design to the end of product life, and the collaborative creation, distribution, application and management of product information across organizations. Yonyou PLM uses jboss by default, and you can access the management control background without authorization An attacker can use this vulnerability to gain server permissions.

Action-Not Available
Vendor-yonyoun/a
Product-ufida_product_lifecycle_managementn/a
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2021-41116
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-8.2||HIGH
EPSS-0.97% / 77.10%
||
7 Day CHG~0.00%
Published-05 Oct, 2021 | 17:40
Updated-04 Aug, 2024 | 02:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Command injection in composer on Windows

Composer is an open source dependency manager for the PHP language. In affected versions windows users running Composer to install untrusted dependencies are subject to command injection and should upgrade their composer version. Other OSs and WSL are not affected. The issue has been resolved in composer versions 1.10.23 and 2.1.9. There are no workarounds for this issue.

Action-Not Available
Vendor-getcomposercomposerTenable, Inc.
Product-composertenable.sccomposer
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-3729
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.9||MEDIUM
EPSS-4.26% / 89.11%
||
7 Day CHG~0.00%
Published-16 Apr, 2025 | 21:00
Updated-29 Apr, 2025 | 19:12
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
SourceCodester Web-based Pharmacy Product Management System Database Backup backup.php os command injection

A vulnerability, which was classified as critical, has been found in SourceCodester Web-based Pharmacy Product Management System 1.0. This issue affects some unknown processing of the file backup.php of the component Database Backup Handler. The manipulation of the argument txtdbname leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-SourceCodesterSenior Walter
Product-web-based_pharmacy_product_management_systemWeb-based Pharmacy Product Management System
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2016-4991
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-9.8||CRITICAL
EPSS-1.30% / 80.21%
||
7 Day CHG~0.00%
Published-28 Jul, 2022 | 16:33
Updated-06 Aug, 2024 | 00:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Input passed to the Pdf() function is shell escaped and passed to child_process.exec() during PDF rendering. However, the shell escape does not properly encode all special characters, namely, semicolon and curly braces. This can be abused to achieve command execution. This problem affects nodepdf 1.3.0.

Action-Not Available
Vendor-nodepdf_projectn/a
Product-nodepdfnodepdf
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-37091
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-4
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-7.2||HIGH
EPSS-1.16% / 79.09%
||
7 Day CHG~0.00%
Published-02 Jun, 2025 | 13:31
Updated-26 Feb, 2026 | 18:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A command injection remote code execution vulnerability exists in HPE StoreOnce Software.

Action-Not Available
Vendor-Hewlett Packard Enterprise (HPE)
Product-storeonce_systemHPE StoreOnce Software
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-23947
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.3||CRITICAL
EPSS-0.05% / 16.05%
||
7 Day CHG~0.00%
Published-20 Jan, 2026 | 00:19
Updated-27 Feb, 2026 | 19:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Orval MCP client is vulnerable to code injection via unsanitized x-enum-descriptions in enum generation

Orval generates type-safe JS clients (TypeScript) from any valid OpenAPI v3 or Swagger v2 specification. Versions prior to 7.19.0 until 8.0.2 are vulnerable to arbitrary code execution in environments consuming generated clients. This issue is similar in nature to CVE-2026-22785, but affects a different code path in @orval/core that was not addressed by CVE-2026-22785's fix. The vulnerability allows untrusted OpenAPI specifications to inject arbitrary TypeScript/JavaScript code into generated clients via the x-enumDescriptions field, which is embedded without proper escaping in getEnumImplementation(). I have confirmed that the injection occurs during const enum generation and results in executable code within the generated schema files. Orval 7.19.0 and 8.0.2 contain a fix for the issue.

Action-Not Available
Vendor-orvalorval-labs
Product-orvalorval
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2021-4045
Matching Score-4
Assigner-Spanish National Cybersecurity Institute, S.A. (INCIBE)
ShareView Details
Matching Score-4
Assigner-Spanish National Cybersecurity Institute, S.A. (INCIBE)
CVSS Score-9.8||CRITICAL
EPSS-91.01% / 99.66%
||
7 Day CHG~0.00%
Published-07 Mar, 2022 | 21:58
Updated-17 Sep, 2024 | 02:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
TP-LINK Tapo C200 remote code execution vulnerability

TP-Link Tapo C200 IP camera, on its 1.1.15 firmware version and below, is affected by an unauthenticated RCE vulnerability, present in the uhttpd binary running by default as root. The exploitation of this vulnerability allows an attacker to take full control of the camera.

Action-Not Available
Vendor-TP-Link Systems Inc.
Product-tapo_c200_firmwaretapo_c200Tapo C200
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • ...
  • 21
  • 22
  • Next
Details not found