Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2026-8260

Summary
Assigner-VulDB
Assigner Org ID-1af790b2-7ee1-4545-860a-a788eba489b5
Published At-11 May, 2026 | 01:15
Updated At-11 May, 2026 | 01:15
Rejected At-
Credits

D-Link DCS-935L HNAP Service hnap_service SetDeviceSettings buffer overflow

A vulnerability was found in D-Link DCS-935L up to 1.10.01. The impacted element is the function SetDeviceSettings of the file /web/cgi-bin/hnap/hnap_service of the component HNAP Service. The manipulation of the argument AdminPassword results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:VulDB
Assigner Org ID:1af790b2-7ee1-4545-860a-a788eba489b5
Published At:11 May, 2026 | 01:15
Updated At:11 May, 2026 | 01:15
Rejected At:
▼CVE Numbering Authority (CNA)
D-Link DCS-935L HNAP Service hnap_service SetDeviceSettings buffer overflow

A vulnerability was found in D-Link DCS-935L up to 1.10.01. The impacted element is the function SetDeviceSettings of the file /web/cgi-bin/hnap/hnap_service of the component HNAP Service. The manipulation of the argument AdminPassword results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

Affected Products
Vendor
D-Link CorporationD-Link
Product
DCS-935L
Modules
  • HNAP Service
Versions
Affected
  • 1.10.01
Problem Types
TypeCWE IDDescription
CWECWE-120Buffer Overflow
CWECWE-119Memory Corruption
Type: CWE
CWE ID: CWE-120
Description: Buffer Overflow
Type: CWE
CWE ID: CWE-119
Description: Memory Corruption
Metrics
VersionBase scoreBase severityVector
4.08.7HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
3.08.8HIGH
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
2.09.0N/A
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Version: 4.0
Base score: 8.7
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 3.0
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
Version: 2.0
Base score: 9.0
Base severity: N/A
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

reporter
0xcc12138 (VulDB User)
Timeline
EventDate
Advisory disclosed2026-05-10 00:00:00
VulDB entry created2026-05-10 02:00:00
VulDB entry last update2026-05-10 17:21:50
Event: Advisory disclosed
Date: 2026-05-10 00:00:00
Event: VulDB entry created
Date: 2026-05-10 02:00:00
Event: VulDB entry last update
Date: 2026-05-10 17:21:50
Replaced By

Rejected Reason

References
HyperlinkResource
https://vuldb.com/vuln/362557
vdb-entry
technical-description
https://vuldb.com/vuln/362557/cti
signature
permissions-required
https://vuldb.com/submit/809888
third-party-advisory
https://github.com/0xcc12138/DCS-935L-HNAP-Service-CVE
exploit
https://www.dlink.com/
product
Hyperlink: https://vuldb.com/vuln/362557
Resource:
vdb-entry
technical-description
Hyperlink: https://vuldb.com/vuln/362557/cti
Resource:
signature
permissions-required
Hyperlink: https://vuldb.com/submit/809888
Resource:
third-party-advisory
Hyperlink: https://github.com/0xcc12138/DCS-935L-HNAP-Service-CVE
Resource:
exploit
Hyperlink: https://www.dlink.com/
Resource:
product
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cna@vuldb.com
Published At:11 May, 2026 | 02:16
Updated At:11 May, 2026 | 02:16

A vulnerability was found in D-Link DCS-935L up to 1.10.01. The impacted element is the function SetDeviceSettings of the file /web/cgi-bin/hnap/hnap_service of the component HNAP Service. The manipulation of the argument AdminPassword results in buffer overflow. The attack can be executed remotely. The exploit has been made public and could be used.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Secondary4.07.4HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary3.18.8HIGH
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Secondary2.09.0HIGH
AV:N/AC:L/Au:S/C:C/I:C/A:C
Type: Secondary
Version: 4.0
Base score: 7.4
Base severity: HIGH
Vector:
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Type: Primary
Version: 3.1
Base score: 8.8
Base severity: HIGH
Vector:
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Type: Secondary
Version: 2.0
Base score: 9.0
Base severity: HIGH
Vector:
AV:N/AC:L/Au:S/C:C/I:C/A:C
CPE Matches

Weaknesses
CWE IDTypeSource
CWE-119Primarycna@vuldb.com
CWE-120Primarycna@vuldb.com
CWE ID: CWE-119
Type: Primary
Source: cna@vuldb.com
CWE ID: CWE-120
Type: Primary
Source: cna@vuldb.com
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
https://github.com/0xcc12138/DCS-935L-HNAP-Service-CVEcna@vuldb.com
N/A
https://vuldb.com/submit/809888cna@vuldb.com
N/A
https://vuldb.com/vuln/362557cna@vuldb.com
N/A
https://vuldb.com/vuln/362557/cticna@vuldb.com
N/A
https://www.dlink.com/cna@vuldb.com
N/A
Hyperlink: https://github.com/0xcc12138/DCS-935L-HNAP-Service-CVE
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/submit/809888
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/vuln/362557
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://vuldb.com/vuln/362557/cti
Source: cna@vuldb.com
Resource: N/A
Hyperlink: https://www.dlink.com/
Source: cna@vuldb.com
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

1257Records found

CVE-2025-6369
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.59%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 21:31
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formdumpeasysetup stack-based overflow

A vulnerability classified as critical has been found in D-Link DIR-619L 2.06B01. Affected is the function formdumpeasysetup of the file /goform/formdumpeasysetup. The manipulation of the argument curTime/config.save_network_enabled leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6334
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.61%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 11:00
Updated-11 Jul, 2025 | 15:55
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-867 Query String strncpy stack-based overflow

A vulnerability has been found in D-Link DIR-867 1.0 and classified as critical. This vulnerability affects the function strncpy of the component Query String Handler. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-867dir-867_firmwareDIR-867
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-5912
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.45% / 80.91%
||
7 Day CHG~0.00%
Published-10 Jun, 2025 | 03:00
Updated-16 Jun, 2025 | 16:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-632 HTTP POST Request do_file stack-based overflow

A vulnerability was found in D-Link DIR-632 FW103B08. It has been declared as critical. This vulnerability affects the function do_file of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-632_firmwaredir-632DIR-632
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11960
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.08% / 86.86%
||
7 Day CHG~0.00%
Published-28 Nov, 2024 | 14:31
Updated-04 Dec, 2024 | 16:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetPortTr buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been declared as critical. This vulnerability affects the function formSetPortTr of the file /goform/formSetPortTr. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-11959
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-3.08% / 86.86%
||
7 Day CHG~0.00%
Published-28 Nov, 2024 | 14:31
Updated-04 Dec, 2024 | 16:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formResetStatistic buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01. It has been classified as critical. This affects the function formResetStatistic of the file /goform/formResetStatistic. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4843
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.50% / 66.11%
||
7 Day CHG~0.00%
Published-17 May, 2025 | 23:31
Updated-04 Jun, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L udev SubUPnPCSInit stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been classified as critical. This affects the function SubUPnPCSInit of the file /sbin/udev. The manipulation of the argument CameraName leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932l_firmwaredcs-932lDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2025-4842
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.50% / 66.11%
||
7 Day CHG~0.00%
Published-17 May, 2025 | 23:00
Updated-04 Jun, 2025 | 20:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-932L ucp isUCPCameraNameChanged stack-based overflow

A vulnerability was found in D-Link DCS-932L 2.18.01. It has been declared as critical. This vulnerability affects the function isUCPCameraNameChanged of the file /sbin/ucp. The manipulation of the argument CameraName leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-932l_firmwaredcs-932lDCS-932L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CWE ID-CWE-787
Out-of-bounds Write
CVE-2024-11047
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.77%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 03:31
Updated-13 Nov, 2024 | 20:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8003 upgrade_filter.asp upgrade_filter_asp stack-based overflow

A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been declared as critical. Affected by this vulnerability is the function upgrade_filter_asp of the file /upgrade_filter.asp. The manipulation of the argument path leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8003_firmwaredi-8003DI-8003di-8003_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2024-11048
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.15% / 35.77%
||
7 Day CHG~0.00%
Published-10 Nov, 2024 | 04:00
Updated-13 Nov, 2024 | 20:53
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-8003 dbsrv.asp dbsrv_asp stack-based overflow

A vulnerability was found in D-Link DI-8003 16.07.16A1. It has been rated as critical. Affected by this issue is the function dbsrv_asp of the file /dbsrv.asp. The manipulation of the argument str leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-8003_firmwaredi-8003DI-8003di-8003_firmware
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-4449
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.93% / 76.22%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 00:31
Updated-13 May, 2025 | 20:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formEasySetupWizard3 buffer overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L 2.04B04. This issue affects the function formEasySetupWizard3. The manipulation of the argument wan_connected leads to buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4346
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.64%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 10:00
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formSetWAN_Wizard534 buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been classified as critical. Affected is the function formSetWAN_Wizard534. The manipulation of the argument host leads to buffer overflow. It is possible to launch the attack remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4344
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.64%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 09:31
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formLogin buffer overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-600L up to 2.07B01. This affects the function formLogin. The manipulation of the argument host leads to buffer overflow. It is possible to initiate the attack remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4347
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.64%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 10:31
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formWlSiteSurvey buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been declared as critical. Affected by this vulnerability is the function formWlSiteSurvey. The manipulation of the argument host leads to buffer overflow. The attack can be launched remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-6368
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.59%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 21:31
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetEmail stack-based overflow

A vulnerability was found in D-Link DIR-619L 2.06B01. It has been rated as critical. This issue affects the function formSetEmail of the file /goform/formSetEmail. The manipulation of the argument curTime/config.smtp_email_subject leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6328
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.80% / 74.18%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 09:31
Updated-11 Jul, 2025 | 15:52
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-815 hedwig.cgi sub_403794 stack-based overflow

A vulnerability was found in D-Link DIR-815 1.01. It has been declared as critical. This vulnerability affects the function sub_403794 of the file hedwig.cgi. The manipulation leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-815_firmwaredir-815DIR-815
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6291
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.83% / 74.56%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 00:00
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-825 HTTP POST Request do_file stack-based overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-825 2.03. This affects the function do_file of the component HTTP POST Request Handler. The manipulation leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-825
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6370
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.59%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 22:00
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formWlanGuestSetup stack-based overflow

A vulnerability classified as critical was found in D-Link DIR-619L 2.06B01. Affected by this vulnerability is the function formWlanGuestSetup of the file /goform/formWlanGuestSetup. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6371
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.62% / 70.04%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 22:31
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetEnableWizard stack-based overflow

A vulnerability, which was classified as critical, has been found in D-Link DIR-619L 2.06B01. Affected by this issue is the function formSetEnableWizard of the file /goform/formSetEnableWizard. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6372
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.60% / 69.48%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 23:00
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetWizard1 stack-based overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-619L 2.06B01. This affects the function formSetWizard1 of the file /goform/formSetWizard1. The manipulation of the argument curTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6374
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.59%
||
7 Day CHG~0.00%
Published-21 Jun, 2025 | 00:00
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetACLFilter stack-based overflow

A vulnerability was found in D-Link DIR-619L 2.06B01 and classified as critical. This issue affects the function formSetACLFilter of the file /goform/formSetACLFilter. The manipulation of the argument curTime leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-6367
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.77% / 73.59%
||
7 Day CHG~0.00%
Published-20 Jun, 2025 | 21:00
Updated-23 Jun, 2025 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetDomainFilter stack-based overflow

A vulnerability was found in D-Link DIR-619L 2.06B01. It has been declared as critical. This vulnerability affects unknown code of the file /goform/formSetDomainFilter. The manipulation of the argument curTime/sched_name_%d/url_%d leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-121
Stack-based Buffer Overflow
CVE-2025-4450
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.93% / 76.22%
||
7 Day CHG~0.00%
Published-09 May, 2025 | 01:00
Updated-13 May, 2025 | 18:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L formSetEasy_Wizard buffer overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-619L 2.04B04. Affected is the function formSetEasy_Wizard. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-4348
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-1.15% / 78.64%
||
7 Day CHG~0.00%
Published-06 May, 2025 | 11:00
Updated-07 May, 2025 | 14:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-600L formSetWanL2TP buffer overflow

A vulnerability was found in D-Link DIR-600L up to 2.07B01. It has been rated as critical. Affected by this issue is the function formSetWanL2TP. The manipulation of the argument host leads to buffer overflow. The attack may be launched remotely. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-DIR-600L
CWE ID-CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9782
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.25% / 48.43%
||
7 Day CHG-0.01%
Published-10 Oct, 2024 | 11:31
Updated-16 Oct, 2024 | 16:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-619L B1 formEasySetupWWConfig buffer overflow

A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formEasySetupWWConfig of the file /goform/formEasySetupWWConfig. The manipulation of the argument curTime leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-619ldir-619l_firmwareDIR-619L B1dir-619l_b1
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9515
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.19% / 40.32%
||
7 Day CHG~0.00%
Published-04 Oct, 2024 | 14:00
Updated-09 Oct, 2024 | 11:19
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetQoS buffer overflow

A vulnerability was found in D-Link DIR-605L 2.13B01 BETA. It has been classified as critical. This affects the function formSetQoS of the file /goform/formSetQoS. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2024-9556
Matching Score-10
Assigner-VulDB
ShareView Details
Matching Score-10
Assigner-VulDB
CVSS Score-8.7||HIGH
EPSS-0.11% / 29.68%
||
7 Day CHG~0.00%
Published-06 Oct, 2024 | 15:31
Updated-08 Oct, 2024 | 18:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-605L formSetEnableWizard buffer overflow

A vulnerability, which was classified as critical, was found in D-Link DIR-605L 2.13B01 BETA. This affects the function formSetEnableWizard of the file /goform/formSetEnableWizard. The manipulation of the argument curTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-605l_firmwaredir-605lDIR-605Ldir-605l_firmware
CWE ID-CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
CVE-2025-10401
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.31% / 53.85%
||
7 Day CHG~0.00%
Published-14 Sep, 2025 | 15:32
Updated-24 Sep, 2025 | 18:41
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823x diag_ping command injection

A vulnerability was detected in D-Link DIR-823x up to 250416. The affected element is an unknown function of the file /goform/diag_ping. Performing manipulation of the argument target_addr results in command injection. Remote exploitation of the attack is possible. The exploit is now public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823x
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10629
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.30%
||
7 Day CHG+0.11%
Published-18 Sep, 2025 | 00:32
Updated-22 Sep, 2025 | 18:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Simple Service Discovery Protocol Service cgibin ssdpcgi_main command injection

A vulnerability was determined in D-Link DIR-852 1.00CN B09. This issue affects the function ssdpcgi_main of the file htodcs/cgibin of the component Simple Service Discovery Protocol Service. Executing manipulation of the argument ST can lead to command injection. The attack may be performed from remote. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10628
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.84%
||
7 Day CHG+0.24%
Published-18 Sep, 2025 | 00:02
Updated-22 Sep, 2025 | 18:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-852 Web Management hedwig.cgi command injection

A vulnerability was found in D-Link DIR-852 1.00CN B09. This vulnerability affects unknown code of the file /htdocs/cgibin/hedwig.cgi of the component Web Management Interface. Performing manipulation results in command injection. The attack is possible to be carried out remotely. The exploit has been made public and could be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-852dir-852_firmwareDIR-852
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10814
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.19% / 40.30%
||
7 Day CHG+0.11%
Published-22 Sep, 2025 | 20:32
Updated-24 Sep, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X goahead command injection

A vulnerability was determined in D-Link DIR-823X 240126/240802/250416. Affected by this vulnerability is an unknown functionality of the file /usr/sbin/goahead. This manipulation of the argument port causes command injection. The attack can be initiated remotely. The exploit has been publicly disclosed and may be utilized.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2025-10634
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.14% / 34.05%
||
7 Day CHG+0.06%
Published-18 Sep, 2025 | 01:02
Updated-24 Sep, 2025 | 18:42
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X Environment Variable goahead sub_412E7C command injection

A weakness has been identified in D-Link DIR-823X 240126/240802/250416. The impacted element is the function sub_412E7C of the file /usr/sbin/goahead of the component Environment Variable Handler. This manipulation of the argument terminal_addr/server_ip/server_port causes command injection. The attack can be initiated remotely. The exploit has been made available to the public and could be exploited.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823xdir-823x_firmwareDIR-823X
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-23754
Matching Score-8
Assigner-VulnCheck
ShareView Details
Matching Score-8
Assigner-VulnCheck
CVSS Score-8.7||HIGH
EPSS-0.05% / 14.12%
||
7 Day CHG-0.00%
Published-21 Jan, 2026 | 18:02
Updated-05 Mar, 2026 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link D-View 8 IDOR Allows Credential Disclosure and Account Takeover

D-Link D-View 8 versions 2.0.1.107 and below contain an improper access control vulnerability in backend API endpoints. Any authenticated user can supply an arbitrary user_id value to retrieve sensitive credential data belonging to other users, including super administrators. The exposed credential material can be reused directly as a valid authentication secret, allowing full impersonation of the targeted account. This results in complete account takeover and full administrative control over the D-View system.

Action-Not Available
Vendor-D-Link Corporation
Product-d-view_8D-View 8
CWE ID-CWE-639
Authorization Bypass Through User-Controlled Key
CVE-2023-5322
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-4.7||MEDIUM
EPSS-0.48% / 64.98%
||
7 Day CHG~0.00%
Published-01 Oct, 2023 | 04:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 edit_manageadmin.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. Affected by this issue is some unknown functionality of the file /sysmanage/edit_manageadmin.php. The manipulation of the argument id leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240992. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2023-6580
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-8.8||HIGH
EPSS-0.25% / 48.07%
||
7 Day CHG~0.00%
Published-07 Dec, 2023 | 21:31
Updated-02 Aug, 2024 | 08:35
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-846 QoS POST deserialization

A vulnerability, which was classified as critical, was found in D-Link DIR-846 FW100A53DBR. This affects an unknown part of the file /HNAP1/ of the component QoS POST Handler. The manipulation of the argument smartqos_express_devices/smartqos_normal_devices leads to deserialization. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-247161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-846_firmwaredir-846DIR-846
CWE ID-CWE-502
Deserialization of Untrusted Data
CVE-2026-2193
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 27.18%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:02
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 set_jhttpd_info command injection

A vulnerability was detected in D-Link DI-7100G C1 24.04.18D1. Affected by this issue is the function set_jhttpd_info. Performing a manipulation of the argument usb_username results in command injection. Remote exploitation of the attack is possible.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1di-7100g_c1_firmwareDI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-5154
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-79.97% / 99.12%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 03:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 changelogo.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-8000 up to 20151231 and classified as critical. This vulnerability affects unknown code of the file /sysmanage/changelogo.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-240250 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-8000DAR-8000dar-8000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5145
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.26% / 49.27%
||
7 Day CHG-0.06%
Published-24 Sep, 2023 | 23:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 licence.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability has been found in D-Link DAR-7000 up to 20151231 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /sysmanage/licence.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240241 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000dar-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5148
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-3.97% / 88.46%
||
7 Day CHG-0.81%
Published-25 Sep, 2023 | 01:00
Updated-24 Sep, 2024 | 19:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 uploadfile.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231. It has been declared as critical. This vulnerability affects unknown code of the file /Tool/uploadfile.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240244. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000dar-8000_firmwaredar-7000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5146
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.33% / 84.95%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 00:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 updatelib.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 and DAR-8000 up to 20151231 and classified as critical. Affected by this issue is some unknown functionality of the file /sysmanage/updatelib.php. The manipulation of the argument file_upload leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-240242 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5151
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-20.38% / 95.58%
||
7 Day CHG~0.00%
Published-25 Sep, 2023 | 01:31
Updated-24 Sep, 2024 | 19:20
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-8000 autheditpwd.php sql injection

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical was found in D-Link DAR-8000 up to 20151231. Affected by this vulnerability is an unknown functionality of the file /autheditpwd.php. The manipulation of the argument hid_id leads to sql injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240247. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-8000DAR-8000dar-8000_firmware
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2026-2169
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.10% / 26.20%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeFibocom command injection

A vulnerability has been found in D-Link DWR-M921 1.1.50. This impacts an unknown function of the file /boafrm/formLtefotaUpgradeFibocom. Such manipulation of the argument fota_url leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2218
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.07% / 21.21%
||
7 Day CHG~0.00%
Published-09 Feb, 2026 | 06:02
Updated-23 Feb, 2026 | 09:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DCS-933L alphapd setSystemAdmin command injection

A vulnerability was determined in D-Link DCS-933L up to 1.14.11. This affects an unknown function of the file /setSystemAdmin of the component alphapd. This manipulation of the argument AdminID causes command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dcs-933ldcs-933l_firmwareDCS-933L
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2194
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.80%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 23:32
Updated-23 Feb, 2026 | 09:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DI-7100G C1 start_proxy_client_email command injection

A flaw has been found in D-Link DI-7100G C1 24.04.18D1. This affects the function start_proxy_client_email. Executing a manipulation can lead to command injection. The attack can be executed remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-di-7100g_c1di-7100g_c1_firmwareDI-7100G C1
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2026-2168
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.31%
||
7 Day CHG~0.00%
Published-08 Feb, 2026 | 17:32
Updated-23 Feb, 2026 | 09:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DWR-M921 formLtefotaUpgradeQuectel sub_419920 command injection

A flaw has been found in D-Link DWR-M921 1.1.50. This affects the function sub_419920 of the file /boafrm/formLtefotaUpgradeQuectel. This manipulation of the argument fota_url causes command injection. It is possible to initiate the attack remotely. The exploit has been published and may be used.

Action-Not Available
Vendor-D-Link Corporation
Product-dwr-m921dwr-m921_firmwareDWR-M921
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CVE-2023-5150
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.44% / 63.29%
||
7 Day CHG-0.10%
Published-25 Sep, 2023 | 01:31
Updated-18 Jun, 2025 | 14:22
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 web.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in D-Link DAR-7000 and DAR-8000 up to 20151231. Affected is an unknown function of the file /useratte/web.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-240246 is the identifier assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-8000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5144
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-2.81% / 86.23%
||
7 Day CHG~0.00%
Published-24 Sep, 2023 | 23:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000/DAR-8000 updateos.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability, which was classified as critical, was found in D-Link DAR-7000 and DAR-8000 up to 20151231. Affected is an unknown function of the file /sysmanage/updateos.php. The manipulation of the argument file_upload leads to unrestricted upload. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-240240. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-8000_firmwaredar-7000dar-7000_firmwaredar-8000DAR-7000DAR-8000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5147
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-1.17% / 78.80%
||
7 Day CHG-0.25%
Published-25 Sep, 2023 | 00:31
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 updateos.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been classified as critical. This affects an unknown part of the file /sysmanage/updateos.php. The manipulation of the argument 1_file_upload leads to unrestricted upload. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-240243. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000dar-7000_firmware
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2023-5149
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-6.3||MEDIUM
EPSS-0.48% / 65.43%
||
7 Day CHG-0.10%
Published-25 Sep, 2023 | 01:00
Updated-02 Aug, 2024 | 08:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DAR-7000 userattestation.php unrestricted upload

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000 up to 20151231. It has been rated as critical. This issue affects some unknown processing of the file /useratte/userattestation.php. The manipulation of the argument web_img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-240245 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Action-Not Available
Vendor-D-Link Corporation
Product-dar-7000_firmwaredar-7000DAR-7000
CWE ID-CWE-434
Unrestricted Upload of File with Dangerous Type
CVE-2026-4465
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.11% / 29.69%
||
7 Day CHG~0.00%
Published-20 Mar, 2026 | 02:02
Updated-03 Apr, 2026 | 19:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-513 formSysCmd os command injection

A flaw has been found in D-Link DIR-513 1.10. The impacted element is an unknown function of the file /goform/formSysCmd. Executing a manipulation of the argument sysCmd can lead to os command injection. The attack may be launched remotely. The exploit has been published and may be used. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-513_firmwaredir-513DIR-513
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2026-1544
Matching Score-8
Assigner-VulDB
ShareView Details
Matching Score-8
Assigner-VulDB
CVSS Score-5.3||MEDIUM
EPSS-0.03% / 9.80%
||
7 Day CHG~0.00%
Published-28 Jan, 2026 | 21:32
Updated-23 Feb, 2026 | 09:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
D-Link DIR-823X set_mode sub_41E2A0 os command injection

A security flaw has been discovered in D-Link DIR-823X 250416. Impacted is the function sub_41E2A0 of the file /goform/set_mode. Performing a manipulation of the argument lan_gateway results in os command injection. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks. This vulnerability only affects products that are no longer supported by the maintainer.

Action-Not Available
Vendor-D-Link Corporation
Product-dir-823x_firmwaredir-823xDIR-823X
CWE ID-CWE-77
Improper Neutralization of Special Elements used in a Command ('Command Injection')
CWE ID-CWE-78
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • 25
  • 26
  • Next
Details not found