Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools

LCDS Laquis SCADA

Source -

CNA

CNA CVEs -

11

ADP CVEs -

0

CISA CVEs -

0

NVD CVEs -

0
Related CVEsRelated VendorsRelated AssignersReports
11Vulnerabilities found

CVE-2018-18994
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.1||HIGH
EPSS-0.13% / 33.32%
||
7 Day CHG~0.00%
Published-27 Mar, 2019 | 17:38
Updated-05 Aug, 2024 | 11:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.

Action-Not Available
Vendor-laquisscadaLCDS Laquis
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-18990
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-4.26% / 88.37%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-17 Sep, 2024 | 01:21
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-18992
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-0.43% / 62.06%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 18:09
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CVE-2018-19029
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.47% / 63.58%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 22:25
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.

Action-Not Available
Vendor-lcdsLCDS
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-822
Untrusted Pointer Dereference
CWE ID-CWE-476
NULL Pointer Dereference
CVE-2018-19002
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.47% / 63.58%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 20:27
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.

Action-Not Available
Vendor-lcdsLCDS
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-94
Improper Control of Generation of Code ('Code Injection')
CVE-2018-18986
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-0.47% / 63.58%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-17 Sep, 2024 | 00:17
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.

Action-Not Available
Vendor-lcdsLCDS
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-787
Out-of-bounds Write
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-18996
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.71% / 71.46%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 22:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-74
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
CWE ID-CWE-862
Missing Authorization
CVE-2018-18998
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.72% / 71.59%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 20:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-798
Use of Hard-coded Credentials
CVE-2018-19000
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.45% / 62.82%
||
7 Day CHG~0.00%
Published-05 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 19:57
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-287
Improper Authentication
CVE-2018-19004
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-3.3||LOW
EPSS-0.14% / 34.62%
||
7 Day CHG~0.00%
Published-01 Feb, 2019 | 18:00
Updated-16 Sep, 2024 | 18:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-125
Out-of-bounds Read
CVE-2018-18988
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.8||HIGH
EPSS-1.10% / 77.17%
||
7 Day CHG~0.00%
Published-01 Feb, 2019 | 17:00
Updated-16 Sep, 2024 | 17:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.

Action-Not Available
Vendor-lcdsICS-CERT
Product-laquis_scadaLCDS Laquis SCADA
CWE ID-CWE-125
Out-of-bounds Read
CWE ID-CWE-20
Improper Input Validation