2Vulnerabilities found

CVE-2026-41125
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-5.9||MEDIUM
EPSS-Not Assigned
Published-12 May, 2026 | 08:21
Updated-12 May, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions), blueplanet 105 TL3 (All versions), blueplanet 105 TL3 GEN2 (All versions), blueplanet 110 TL3 (All versions), blueplanet 125 NX3 M11 (All versions), blueplanet 125 TL3 (All versions), blueplanet 125 TL3 GEN2 (All versions), blueplanet 137 TL3 (All versions), blueplanet 150 TL3 (All versions), blueplanet 150 TL3 GEN2 (All versions), blueplanet 155 TL3 (All versions), blueplanet 155 TL3 GEN2 (All versions), blueplanet 165 TL3 (All versions), blueplanet 165 TL3 GEN2 (All versions), blueplanet 25.0 NX3-33.0 NX3 (All versions), blueplanet 3.0 NX3-20.0 NX3 (All versions), blueplanet 3.0-5.0 NX1 (All versions), blueplanet 360 NX3 M6 (All versions), blueplanet 50.0 NX3-60.0 NX3 (All versions), blueplanet 87.0 TL3 (All versions), blueplanet 87.0 TL3 GEN2 (All versions), blueplanet 92.0 TL3 (All versions), blueplanet 92.0 TL3 GEN2 (All versions), blueplanet gridsafe 110 TL3-S (All versions), blueplanet gridsafe 137 TL3-S (All versions), blueplanet gridsafe 92.0 TL3-S (All versions), blueplanet hybrid 10.0 TL3 (All versions), blueplanet hybrid 6.0 NH3-12.0 NH3 (All versions). Improper neutralization of special elements used in an sql command ('sql injection') in KACO Meteor server allows an authorized attacker to elevate privileges over a local network.

Action-Not Available
Vendor-Siemens AG
Product-blueplanet 3.0 NX3-20.0 NX3blueplanet 50.0 NX3-60.0 NX3blueplanet 137 TL3blueplanet hybrid 10.0 TL3blueplanet 87.0 TL3blueplanet 125 TL3 GEN2blueplanet gridsafe 137 TL3-Sblueplanet 110 TL3blueplanet 25.0 NX3-33.0 NX3blueplanet 150 TL3blueplanet 165 TL3blueplanet 92.0 TL3 GEN2blueplanet 155 TL3 GEN2blueplanet 92.0 TL3blueplanet 155 TL3blueplanet 150 TL3 GEN2blueplanet 165 TL3 GEN2blueplanet gridsafe 92.0 TL3-Sblueplanet 360 NX3 M6blueplanet 125 NX3 M11blueplanet 125 TL3blueplanet 100 TL3 GEN2blueplanet 100 NX3 M8blueplanet 87.0 TL3 GEN2blueplanet gridsafe 110 TL3-Sblueplanet 105 TL3blueplanet 105 TL3 GEN2blueplanet 3.0-5.0 NX1blueplanet hybrid 6.0 NH3-12.0 NH3
CWE ID-CWE-89
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
CVE-2025-40946
Assigner-Siemens
ShareView Details
Assigner-Siemens
CVSS Score-7.2||HIGH
EPSS-Not Assigned
Published-12 May, 2026 | 08:20
Updated-12 May, 2026 | 10:16
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions), blueplanet 125 NX3 M11 (All versions), blueplanet 125 TL3 (All versions), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions), blueplanet 150 TL3 (All versions), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 25.0 NX3-33.0 NX3 (All versions), blueplanet 3.0 NX3-20.0 NX3 (All versions), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 3.0-5.0 NX1 (All versions), blueplanet 360 NX3 M6 (All versions), blueplanet 50.0 NX3-60.0 NX3 (All versions), blueplanet 87.0 TL3 (All versions), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsafe 110 TL3-S (All versions < V3.91), blueplanet gridsafe 137 TL3-S (All versions < V3.91), blueplanet gridsafe 92.0 TL3-S (All versions < V3.91), blueplanet hybrid 10.0 TL3 (All versions), blueplanet hybrid 6.0 NH3-12.0 NH3 (All versions). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.

Action-Not Available
Vendor-Siemens AG
Product-blueplanet 3.0 NX3-20.0 NX3blueplanet 50.0 NX3-60.0 NX3blueplanet 137 TL3blueplanet 3.0 TL3-60.0 TL3blueplanet hybrid 10.0 TL3blueplanet 87.0 TL3blueplanet 125 TL3 GEN2blueplanet gridsafe 137 TL3-Sblueplanet 110 TL3blueplanet 25.0 NX3-33.0 NX3blueplanet 150 TL3blueplanet 165 TL3blueplanet 92.0 TL3 GEN2blueplanet 155 TL3 GEN2blueplanet 92.0 TL3blueplanet 155 TL3blueplanet 150 TL3 GEN2blueplanet 165 TL3 GEN2blueplanet gridsafe 92.0 TL3-Sblueplanet 360 NX3 M6blueplanet 125 NX3 M11blueplanet 125 TL3blueplanet 100 TL3 GEN2blueplanet 100 NX3 M8blueplanet 87.0 TL3 GEN2blueplanet gridsafe 110 TL3-Sblueplanet 105 TL3blueplanet 105 TL3 GEN2blueplanet 3.0-5.0 NX1blueplanet hybrid 6.0 NH3-12.0 NH3
CWE ID-CWE-321
Use of Hard-coded Cryptographic Key