The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory.
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, a buffer overflow vulnerability exist in cgi program "set".
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
A Stack-Based Buffer Overflow issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The stack-based buffer overflow vulnerability has been identified, which may allow a remote attacker to execute arbitrary code in the context of a highly privileged account.
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX.
A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
Adobe Reader and Acrobat 10.x before 10.1.12 and 11.x before 11.0.09 on Windows and OS X allow attackers to cause a denial of service (memory corruption) via unspecified vectors.
A vulnerability in the Session Initiation Protocol (SIP) UDP throttling process of Cisco Unified Communications Manager (Cisco Unified CM) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient rate limiting protection. An attacker could exploit this vulnerability by sending the affected device a high rate of SIP messages. An exploit could allow the attacker to cause the device to reload unexpectedly. The device and services will restart automatically. This vulnerability affects Cisco Unified Communications Manager (CallManager) releases prior to the first fixed release; the following list indicates the first minor release that includes the fix for this vulnerability: 10.5.2.14900-16 11.0.1.23900-5 11.5.1.12900-2. Cisco Bug IDs: CSCuz72455.
Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes a failure to start the SYS600. The configuration file can only be accessed by an administrator access. This issue affects: Hitachi Energy MicroSCADA X SYS600 version 10 to version 10.3.1. cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.1.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:* cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*
A vulnerability was found in libX11. The security flaw occurs because the functions in src/InitExt.c in libX11 do not check that the values provided for the Request, Event, or Error IDs are within the bounds of the arrays that those functions write to, using those IDs as array indexes. They trust that they were called with values provided by an Xserver adhering to the bounds specified in the X11 protocol, as all X servers provided by X.Org do. As the protocol only specifies a single byte for these values, an out-of-bounds value provided by a malicious server (or a malicious proxy-in-the-middle) can only overwrite other portions of the Display structure and not write outside the bounds of the Display structure itself, possibly causing the client to crash with this memory corruption.
An unchecked read in NTP server in github.com/cloudflare/cfnts prior to commit 783490b https://github.com/cloudflare/cfnts/commit/783490b913f05e508a492cd7b02e3c4ec2297b71 enabled a remote attacker to trigger a panic by sending an NTSAuthenticator packet with extension length longer than the packet contents.
The Clientless SSL VPN feature in Cisco Adaptive Security Appliance (ASA) Software 8.x before 8.2(5.44), 8.3.x before 8.3(2.39), 8.4.x before 8.4(5.7), 8.6.x before 8.6(1.12), 9.0.x before 9.0(2.6), and 9.1.x before 9.1(1.7) allows remote attackers to cause a denial of service (device reload) via crafted HTTPS requests, aka Bug ID CSCua22709.
Huawei AR 150, 200, 1200, 2200, and 3200 routers, when SNMPv3 is enabled, allow remote attackers to cause a denial of service (device crash) via malformed SNMPv3 requests that leverage unspecified overflow issues.
A vulnerability was identified in osrg GoBGP up to 4.3.0. Affected by this issue is the function BMPPeerUpNotification.ParseBody/BMPStatisticsReport.ParseBody of the file pkg/packet/bmp/bmp.go of the component BMP Parser. The manipulation leads to out-of-bounds read. The attack can be initiated remotely. Upgrading to version 4.4.0 can resolve this issue. The identifier of the patch is bc77597d42335c78464bc8e15a471d887bbdf260. Upgrading the affected component is recommended.
Cisco Adaptive Security Appliance (ASA) Software 8.4.x before 8.4(3) and 8.6.x before 8.6(1.3) does not properly manage memory upon an AnyConnect SSL VPN client disconnection, which allows remote attackers to cause a denial of service (memory consumption, and forwarding outage or system hang) via packets to the disconnected machine's IP address, aka Bug ID CSCtt36737.
The Windows NAT Driver (aka winnat) service in Microsoft Windows Server 2012 does not properly validate memory addresses during the processing of ICMP packets, which allows remote attackers to cause a denial of service (memory corruption and system hang) via crafted packets, aka "Windows NAT Denial of Service Vulnerability."
The TCP/IP implementation in Microsoft Windows Vista SP2, Windows Server 2008 SP2 and R2 SP1, Windows 7 SP1, Windows 8, Windows Server 2012, and Windows RT does not properly perform memory allocation for inbound ICMPv6 packets, which allows remote attackers to cause a denial of service (system hang) via crafted packets, aka "ICMPv6 Vulnerability."
IBM MQ 9.2 CD, 9.2 LTS, 9.3 CD, and 9.3 LTS could allow a remote attacker to cause a denial of service due to an error processing invalid data. IBM X-Force ID: 248418.
Cisco Intrusion Prevention System (IPS) Software on IPS NME devices before 7.0(9)E4 allows remote attackers to cause a denial of service (device reload) via malformed IPv4 packets that trigger incorrect memory allocation, aka Bug ID CSCua61977.
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). An attacker with network access to port 10005/tcp of the LOGO! device could cause a Denial-of-Service condition by sending specially crafted packets. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises availability of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
An Untrusted Pointer Dereference was discovered in function mrb_vm_exec in mruby before 3.1.0-rc. The vulnerability causes a segmentation fault and application crash.
Triangle MicroWorks SCADA Data Gateway 2.50.0309 through 3.00.0616, DNP3 .NET Protocol components 3.06.0.171 through 3.15.0.369, and DNP3 C libraries 3.06.0000 through 3.15.0000 allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet.
A vulnerability has been found in Tenda TX3 16.03.13.11_multi and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
A vulnerability was detected in Open5GS up to 2.7.7. This affects the function ogs_sbi_client_send_via_scp_or_sepp in the library lib/sbi/client.c of the component NF. Performing a manipulation results in out-of-bounds read. The attack is possible to be carried out remotely. The patch is named d5bc487fcf9ea87d2b03f2ef95123af344773bfb. It is suggested to install a patch to address this issue.
A vulnerability classified as critical has been found in Tenda TX3 16.03.13.11_multi. This affects an unknown part of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
The General Responder implementation in the IP Service Level Agreement (SLA) feature in Cisco IOS 15.2 and IOS XE 3.1.xS through 3.4.xS before 3.4.5S and 3.5.xS through 3.7.xS before 3.7.2S allows remote attackers to cause a denial of service (device reload) via crafted (1) IPv4 or (2) IPv6 IP SLA packets on UDP port 1167, aka Bug ID CSCuc72594.
An exploitable memory corruption vulnerability exists in the Name Service Client functionality of 3S-Smart Software Solutions CODESYS GatewayService. A specially crafted packet can cause a large memcpy, resulting in an access violation and termination of the process. An attacker can send a packet to a device running the GatewayService.exe to trigger this vulnerability. All variants of the CODESYS V3 products in all versions prior V3.5.16.10 containing the CmpRouter or CmpRouterEmbedded component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PLCnext, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS Control V3 Runtime System Toolkit, CODESYS V3 Embedded Target Visu Toolkit, CODESYS V3 Remote Target Visu Toolkit, CODESYS V3 Safety SIL2, CODESYS Edge Gateway V3, CODESYS Gateway V3, CODESYS HMI V3, CODESYS OPC Server V3, CODESYS PLCHandler SDK, CODESYS V3 Simulation Runtime (part of the CODESYS Development System).
The Smart Install client functionality in Cisco IOS 12.2 and 15.0 through 15.3 on Catalyst switches allows remote attackers to cause a denial of service (device reload) via crafted image list parameters in Smart Install packets, aka Bug ID CSCub55790.
RIOT-OS, an operating system for Internet of Things (IoT) devices, contains a network stack with the ability to process 6LoWPAN frames. Prior to version 2023.04, an attacker can send a crafted frame to the device resulting in an integer underflow and out of bounds access in the packet buffer. Triggering the access at the right time will corrupt other packets or the allocator metadata. Corrupting a pointer will lead to denial of service. This issue is fixed in version 2023.04. As a workaround, disable SRH in the network stack.
The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this vulnerability could cause loss of availability and a disruption in communications with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
VMware vCenter Server 4.1 before Update 3 and 5.0 before Update 2, and vCSA 5.0 before Update 2, allows remote attackers to cause a denial of service (disk consumption) via vectors that trigger large log entries.
Samsung NET-i viewer 1.37.120316 allows remote attackers to cause a denial of service (infinite loop) via a negative size value in a TCP request to (1) NiwMasterService or (2) NiwStorageService. NOTE: some of these details are obtained from third party information.
The Samsung D6000 TV and possibly other products allows remote attackers to cause a denial of service (crash) via a long string in certain fields, as demonstrated by the MAC address field, possibly a buffer overflow.
The Arbiter Power Sentinel 1133A device with firmware before 11Jun2012 Rev 421 allows remote attackers to cause a denial of service (Ethernet outage) via unspecified Ethernet traffic that fills a buffer, as demonstrated by a port scan.
contrib/slapd-modules/nops/nops.c in OpenLDAP through 2.4.45, when both the nops module and the memberof overlay are enabled, attempts to free a buffer that was allocated on the stack, which allows remote attackers to cause a denial of service (slapd crash) via a member MODDN operation.
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.