Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.
When encrypting with a block cipher, if a call to NSC_EncryptUpdate was made with data smaller than the block size, a small out of bounds write could occur. This could have caused heap corruption and a potentially exploitable crash. This vulnerability affects Thunderbird < 68.3, Firefox ESR < 68.3, and Firefox < 71.
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker in a privileged network position between a legitimate user and the web server might be able to conduct a Man-in-the-middle attack and gain read and write access to the transmitted data.
BIND servers are vulnerable if they are running an affected version and are configured to use GSS-TSIG features. In a configuration which uses BIND's default settings the vulnerable code path is not exposed, but a server can be rendered vulnerable by explicitly setting valid values for the tkey-gssapi-keytab or tkey-gssapi-credentialconfiguration options. Although the default configuration is not vulnerable, GSS-TSIG is frequently used in networks where BIND is integrated with Samba, as well as in mixed-server environments that combine BIND servers with Active Directory domain controllers. The most likely outcome of a successful exploitation of the vulnerability is a crash of the named process. However, remote code execution, while unproven, is theoretically possible. Affects: BIND 9.5.0 -> 9.11.27, 9.12.0 -> 9.16.11, and versions BIND 9.11.3-S1 -> 9.11.27-S1 and 9.16.8-S1 -> 9.16.11-S1 of BIND Supported Preview Edition. Also release versions 9.17.0 -> 9.17.1 of the BIND 9.17 development branch
Node.js versions before 10.23.1, 12.20.1, 14.15.4, 15.5.1 are vulnerable to a use-after-free bug in its TLS implementation. When writing to a TLS enabled socket, node::StreamBase::Write calls node::TLSWrap::DoWrite with a freshly allocated WriteWrap object as first argument. If the DoWrite method does not return an error, this object is passed back to the caller as part of a StreamWriteResult structure. This may be exploited to corrupt memory leading to a Denial of Service or potentially other exploits.
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write into uninitialized memory. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in a out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PCX files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer in the font index handling function. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CG4 and CGM files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11898)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of JT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11972)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing CGM files. This could lead to a stack based buffer overflow while trying to copy to a buffer during font string handling. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of RGB and SGI files. This could result in a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11986, ZDI-CAN-11994)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12016, ZDI-CAN-12017)
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of SGI and RGB files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11992)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11891)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing PDF files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11900)
A vulnerability has been identified in JT2Go (All versions < V13.1.0.2), Teamcenter Visualization (All versions < V13.1.0.2). Affected applications lack proper validation of user-supplied data when parsing ASM files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11899)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of JT files. This could lead to a heap-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12014)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing of CG4 files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12027)
A vulnerability has been identified in JT2Go (All versions < V13.1.0), Teamcenter Visualization (All versions < V13.1.0). Affected applications lack proper validation of user-supplied data when parsing JT files. A crafted JT file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11881)
A vulnerability has been identified in JT2Go (All versions < V13.1.0.1), Teamcenter Visualization (All versions < V13.1.0.1). Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897)
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An error in the challenge-response procedure could allow an attacker to replay authentication traffic and gain access to protected areas of the web application.
The Siemens web application RUGGEDCOM NMS < V1.2 on port 8080/TCP and 8081/TCP could allow a remote attacker to perform a Cross-Site Request Forgery (CSRF) attack, potentially allowing an attacker to execute administrative operations, provided the targeted user has an active session and is induced to trigger a malicious request.
A vulnerability has been identified in SIEMENS LOGO!8 (6ED1052-xyyxx-0BA8 FS:01 to FS:06 / Firmware version V1.80.xx and V1.81.xx), SIEMENS LOGO!8 (6ED1052-xyy08-0BA0 FS:01 / Firmware version < V1.82.02). The integrated webserver does not invalidate the Session ID upon user logout. An attacker that successfully extracted a valid Session ID is able to use it even after the user logs out. The security vulnerability could be exploited by an attacker in a privileged network position who is able to read the communication between the affected device and the user or by an attacker who is able to obtain valid Session IDs through other means. The user must invoke a session to the affected device. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in PADS Standard/Plus Viewer (All versions). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted PCB files. This could allow an attacker to execute code in the context of the current process. (FG-VD-22-041)
A vulnerability has been identified in JT2Go (All versions < V13.2.0.5), Teamcenter Visualization (All versions < V13.2.0.5). The DL180pdfl.dll contains an out of bounds write past the end of an allocated structure while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14974)
A vulnerability has been identified in XHQ (All Versions < 6.1). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15592)
A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15114)
Wind River VxWorks 6.9.4 and vx7 has a Buffer Overflow in the TCP component (issue 4 of 4). There is an IPNET security vulnerability: TCP Urgent Pointer state confusion due to race condition.
A vulnerability has been identified in Simcenter STAR-CCM+ Viewer (All versions < V2021.2.1). The starview+.exe application lacks proper validation of user-supplied data when parsing scene files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13700)
A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.3). The vulnerability could allow an attacker to execute arbitrary code if the attacker tricks a legitimate user to open a manipulated project. In order to exploit the vulnerability, a valid user must open a manipulated project file. No further privileges are required on the target system. The vulnerability could compromise the confidentiality, integrity and availability of the engineering station. At the time of advisory publication no public exploitation of this security vulnerability was known.
The Milestone XProtect Video Management Software (Corporate, Expert, Professional+, Express+, Essential+) 2016 R1 (10.0.a) to 2018 R1 (12.1a) contains .NET Remoting endpoints that are vulnerable to deserialization attacks resulting in remote code execution.
nextScaffoldPart in xmlparse.c in Expat (aka libexpat) before 2.4.3 has an integer overflow.
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains a stack based buffer overflow vulnerability while parsing specially crafted BDF files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15061)
A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-14754, ZDI-CAN-15082)
A vulnerability has been identified in Automation License Manager 5 (All versions < 5.3.4.4), Automation License Manager 6 (All versions < 6.0.1). A directory traversal vulnerability could allow a remote attacker to move arbitrary files, which can result in code execution, compromising confidentiality, integrity and availability of the system. Successful exploitation requires a network connection to the affected device. The attacker does not need privileges or special conditions of the system, but user interaction is required.
A vulnerability has been identified in SCALANCE M875 (All versions). The web interface on port 443/tcp could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by an legitimate user, who must be authenticated to the web interface as administrative user. A successful attack could allow an attacker to interact with the web interface as an administrative user. This could allow the attacker to read or modify the device configuration, or to exploit other vulnerabilities that require authentication as administrative user. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in Simcenter Femap (All versions < V2022.1.1). Affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-15048)