Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
DoraCMS 2.1.8 is vulnerable to Use of Hard-coded Cryptographic Key.
Allegra Hard-coded Credentials Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Allegra. Authentication is not required to exploit this vulnerability. The specific flaw exists within the configuration of a database. The issue results from the use of a hardcoded password. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-22360.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for the telnet service stored in the component /web_cste/cgi-bin/product.ini.
An issue was discovered in Infiray IRAY-A8Z3 1.0.957. The binary file /usr/local/sbin/webproject/set_param.cgi contains hardcoded credentials to the web application. Because these accounts cannot be deactivated or have their passwords changed, they are considered to be backdoor accounts.
In Carlo Gavazzi UWP3.0 in multiple versions and CPY Car Park Server in Version 2.8.3 a remote, unauthenticated attacker could make use of hard-coded credentials to gain SuperUser access to the device.
A vulnerability was found in Belkin F9K1009 and F9K1010 2.00.04/2.00.09 and classified as critical. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to hard-coded credentials. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered on Intelbras NCLOUD 300 1.0 devices. /cgi-bin/ExportSettings.sh, /goform/updateWPS, /goform/RebootSystem, and /goform/vpnBasicSettings do not require authentication. For example, when an HTTP POST request is made to /cgi-bin/ExportSettings.sh, the username, password, and other details are retrieved.
An authentication bypass vulnerability exists in the web interface /action/factory* functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9X and 6.9Z. A specially-crafted HTTP header can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
Hardcoded admin token in SoundBar apps in Linkplay SDK 1.00 allows remote attackers to gain admin privilege access in linkplay antifactory
Clinic Image System developed by Changing contains hard-coded Credentials, allowing unauthenticated remote attackers to log into the system using administrator credentials embedded in the source code.
Rakuten Casa version AP_F_V1_4_1 or AP_F_V2_0_0 uses a hard-coded credential which may allow a remote unauthenticated attacker to log in with the root privilege and perform an arbitrary operation.
TOTOLINK A3100R V4.1.2cu.5050_B20200504 and V4.1.2cu.5247_B20211129 were discovered to contain a hard coded password for root stored in the component /etc/shadow.sample.
Invoxia NVX220 devices allow TELNET access as admin with a default password.
Battelle V2I Hub 2.5.1 contains hard-coded credentials for the administrative account. An attacker could exploit this vulnerability to log in as an admin on any installation and gain unauthorized access to the system.
Proietti Tech srl Planet Time Enterprise 4.2.0.1,4.2.0.0,4.1.0.0,4.0.0.0,3.3.1.0,3.3.0.0 is vulnerable to Remote code execution via the Viewstate parameter.
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Quest Foglight Evolve 9.0.0. Authentication is not required to exploit this vulnerability. The specific flaw exists within the __service__ user account. The product contains a hard-coded password for this account. An attacker can leverage this vulnerability to execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-9553.
Programi Bilanc Build 007 Release 014 31.01.2020 supplies a .exe file containing several hardcoded credentials to different servers that allow remote attackers to gain access to the complete infrastructure including the website, update server, and external issue tracking tools.
TimeTools SC7105 1.0.007, SC9205 1.0.007, SC9705 1.0.007, SR7110 1.0.007, SR9210 1.0.007, SR9750 1.0.007, SR9850 1.0.007, T100 1.0.003, T300 1.0.003, and T550 1.0.003 devices allow remote attackers to bypass authentication by placing t3axs=TiMEtOOlsj7G3xMm52wB in a t3.cgi request, aka a "hardcoded cookie."
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
A vulnerability in Cisco Digital Network Architecture (DNA) Center could allow an unauthenticated, remote attacker to log in to an affected system by using an administrative account that has default, static user credentials. The vulnerability is due to the presence of undocumented, static user credentials for the default administrative account for the affected software. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands with root privileges. This vulnerability affects all releases of Cisco DNA Center Software prior to Release 1.1.3. Cisco Bug IDs: CSCvh98929.
Juniper Networks Contrail Service Orchestrator versions prior to 4.0.0 use hardcoded cryptographic certificates and keys in some cases, which may allow network based attackers to gain unauthorized access to services.
A vulnerability in Cisco IOS XE Software could allow an unauthenticated, remote attacker to log in to a device running an affected release of Cisco IOS XE Software with the default username and password that are used at initial boot, aka a Static Credential Vulnerability. The vulnerability is due to an undocumented user account with privilege level 15 that has a default username and password. An attacker could exploit this vulnerability by using this account to remotely connect to an affected device. A successful exploit could allow the attacker to log in to the device with privilege level 15 access. This vulnerability affects Cisco devices that are running a vulnerable release of Cisco IOS XE Software Release 16.x. This vulnerability does not affect Cisco IOS XE Software releases prior to Release 16.x. Cisco Bug IDs: CSCve89880.
An issue was discovered in EyesOfNetwork 5.3. The installation uses the same API key (hardcoded as EONAPI_KEY in include/api_functions.php for API version 2.4.2) by default for all installations, hence allowing an attacker to calculate/guess the admin access token.
ASUS WebStorage has a hardcoded API Token in the APP source code. An unauthenticated remote attacker can use this token to establish connections with the server and carry out login attempts to general user accounts. A successful login to a general user account allows the attacker to access, modify or delete this user account information.
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
The Atlassian Questions For Confluence app for Confluence Server and Data Center creates a Confluence user account in the confluence-users group with the username disabledsystemuser and a hardcoded password. A remote, unauthenticated attacker with knowledge of the hardcoded password could exploit this to log into Confluence and access all content accessible to users in the confluence-users group. This user account is created when installing versions 2.7.34, 2.7.35, and 3.0.2 of the app.
Intellian Aptus Web 1.24 has a hardcoded password of 12345678 for the intellian account.
NUUO v03.11.00 was discovered to contain access control issue.
The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.
Bettini Srl GAMS Product Line v4.3.0 was discovered to re-use static SSH keys across installations, allowing unauthenticated attackers to login as root users via extracting a key from the software.
Databasir is a team-oriented relational database model document management platform. Databasir 1.01 has Use of Hard-coded Cryptographic Key vulnerability. An attacker can use hard coding to generate login credentials of any user and log in to the service background located at different IP addresses.
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, these devices use a hard-coded service code for access to the console.
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
The Intellian Aptus application 1.0.2 for Android has a hardcoded password of intellian for the masteruser FTP account.
Use of a static key to protect a JWT token used in user authentication can allow an for an authentication bypass in D-Link D-View 8 v2.0.1.28
Trend Micro ServerProtect 6.0/5.8 Information Server uses a static credential to perform authentication when a specific command is typed in the console. An unauthenticated remote attacker with access to the Information Server could exploit this to register to the server and perform authenticated actions.
USR IOT 4G LTE Industrial Cellular VPN Router v1.0.36 was discovered to contain hard-coded credentials for its highest privileged account. The credentials cannot be altered through normal operation of the device.
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
Baicells Nova436Q and Neutrino 430 devices with firmware through QRTB 2.7.8 have hardcoded credentials that are easily discovered, and can be used by remote attackers to authenticate via ssh. (The credentials are stored in the firmware, encrypted by the crypt function.)
The Premium Age Verification / Restriction for WordPress plugin for WordPress is vulnerable to arbitrary file read and write due to the existence of an insufficiently protected remote support functionality in remote_tunnel.php in all versions up to, and including, 3.0.2. This makes it possible for unauthenticated attackers to read from or write to arbitrary files on the affected site's server which may make the exposure of sensitive information or remote code execution possible.
EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R for SAS Solution Packs (EMC ViPR SRM prior to 4.1, EMC Storage M&R prior to 4.1, EMC VNX M&R all versions, EMC M&R (Watch4Net) for SAS Solution Packs all versions) contain undocumented accounts with default passwords for Webservice Gateway and RMI JMX components. A remote attacker with the knowledge of the default password may potentially use these accounts to run arbitrary web service and remote procedure calls on the affected system.
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device has a custom telnet daemon as a part of the busybox and retrieves the password from the shadow file using the function getspnam at address 0x00053894. Then performs a crypt operation on the password retrieved from the user at address 0x000538E0 and performs a strcmp at address 0x00053908 to check if the password is correct or incorrect. However, the /etc/shadow file is a part of CRAM-FS filesystem which means that the user cannot change the password and hence a hardcoded hash in /etc/shadow is used to match the credentials provided by the user. This is a salted hash of the string "admin" and hence it acts as a password to the device which cannot be changed as the whole filesystem is read only.
The vulnerability allows a remote attacker to authenticate to the web application with high privileges through multiple hidden hard-coded accounts.
Use of Hard-coded Credentials in the database of Bosch FSM-2500 server and Bosch FSM-5000 server up to and including version 5.2 allows an unauthenticated remote attacker to log into the database with admin-privileges. This may result in complete compromise of the confidentiality and integrity of the stored data as well as a high availability impact on the database itself. In addition, an attacker may execute arbitrary commands on the underlying operating system.
IBM Spectrum Protect Plus 10.1.0 thorugh 10.1.6 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 190454.
IBM Security Guardium 11.1 contains hard-coded credentials, such as a password or cryptographic key, which it uses for its own inbound authentication, outbound communication to external components, or encryption of internal data. IBM X-Force ID: 174732.
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
Root user password is hardcoded into the device and cannot be changed in the user interface.