A CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in IGSS Definition (Def.exe) version 14.0.0.20247 and prior that could cause Remote Code Execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.
Multiple buffer overflows in the F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allow remote attackers to execute arbitrary code via the (1) Attach, (2) DefinedName, (3) DefinedNameLocal, (4) ODBCPrepareEx, (5) ObjCreatePolygon, (6) SetTabbedTextEx, or (7) SetValidationRule method, a different vulnerability than CVE-2015-8561.
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
Stack-based buffer overflow in an unspecified DLL file in a DTM development kit in Schneider Electric Unity Pro, SoMachine, SoMove, SoMove Lite, Modbus Communication Library 2.2.6 and earlier, CANopen Communication Library 1.0.2 and earlier, EtherNet/IP Communication Library 1.0.0 and earlier, EM X80 Gateway DTM (MB TCP/SL), Advantys DTM for OTB, Advantys DTM for STB, KINOS DTM, SOLO DTM, and Xantrex DTMs allows remote attackers to execute arbitrary code via unspecified vectors.
Multiple buffer overflows in Schneider Electric VAMPSET before 2.2.168 allow local users to gain privileges via malformed disturbance-recording data in a (1) CFG or (2) DAT file.
The PLC driver in ServerMain.exe in the Kepware KepServerEX 4 component in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R2 build 71.4165, 2010 R2.1 build 71.4325, 2010 R3 build 72.4560, 2010 R3.1 build 72.4644, 2013 R1 build 73.4729, 2013 R1.1 build 73.4832, 2013 R1.1a build 73.4903, 2013 R1.2 build 73.4955, and 2013 R2 build 74.5094 allows remote attackers to cause a denial of service (application crash) via a crafted OPF file (aka project file).
Stack-based buffer overflow in Device Type Manager (DTM) 3.1.6 and earlier for Schneider Electric Invensys SRD Control Valve Positioner devices 960 and 991 allows local users to gain privileges via a malformed DLL file.
Buffer overflow in an ActiveX control in MDraw30.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8513 and CVE-2014-8514. NOTE: this may be clarified later based on details provided by researchers.
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8512. NOTE: this may be clarified later based on details provided by researchers.
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Modicon M258 Firmware (All versions prior to V5.0.4.11) and SoMachine/SoMachine Motion software (All versions), that could cause a buffer overflow when the length of a file transferred to the webserver is not verified.
Buffer overflow in the UnitelWay Windows Device Driver, as used in Schneider Electric Unity Pro 6 and earlier, OPC Factory Server 3.34, Vijeo Citect 7.20 and earlier, Telemecanique Driver Pack 2.6 and earlier, Monitor Pro 7.6 and earlier, and PL7 Pro 4.5 and earlier, allows local users, and possibly remote attackers, to execute arbitrary code via an unspecified system parameter.
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to cause a denial of service via unspecified vectors.
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow local attackers to exploit these issues to potentially execute arbitrary code when opening a malicious project file.
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality.
A CWE-119: Buffer Errors vulnerability exists in ProClima (all versions prior to version 8.0.0) which allows an unauthenticated, remote attacker to execute arbitrary code on the targeted system in all versions of ProClima prior to version 8.0.0.
A Stack-based Buffer Overflow issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 Patch 1 and prior versions, and InTouch Machine Edition v8.0 SP2 Patch 1 and prior versions. The stack-based buffer overflow vulnerability has been identified, which may allow remote code execution with high privileges.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause memory corruption when an authenticated user opens a tampered log file from GP-Pro EX.
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
Buffer overflow in Schneider Electric IMT25 Magnetic Flow DTM before 1.500.004 for the HART Protocol allows remote authenticated users to execute arbitrary code or cause a denial of service (memory corruption) via a crafted HART reply.
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
The Schneider Electric M340 BMXNOE01xx and BMXP3420xx PLC modules allow remote authenticated users to cause a denial of service (module crash) via crafted FTP traffic, as demonstrated by the FileZilla FTP client.
Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
A vulnerability in the Control and Provisioning of Wireless Access Points (CAPWAP) Discovery Request parsing functionality of Cisco Wireless LAN Controllers could allow an unauthenticated, remote attacker to cause an affected device to restart unexpectedly, resulting in a denial of service (DoS) condition. The vulnerability is due to incomplete input validation of fields in CAPWAP Discovery Request packets by the affected device. An attacker could exploit this vulnerability by sending crafted CAPWAP Discovery Request packets to an affected device. A successful exploit could allow the attacker to cause the affected device to restart unexpectedly, resulting in a DoS condition. Cisco Bug IDs: CSCvb95842.
The SIP module of some Huawei products have a denial of service (DoS) vulnerability. A remote attacker could exploit these three vulnerabilities by sending the specially crafted messages to the affected device. Due to the insufficient verification of the packets, successful exploit could allow the attacker to cause buffer overflow and dead loop, leading to DoS condition. Affected products can be found in https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200115-01-sip-en.
A vulnerability was found in TRENDnet TEW-652BRP 3.04B01. It has been declared as critical. This vulnerability affects unknown code of the file cfg_op.ccp of the component Web Service. The manipulation leads to memory corruption. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-219958 is the identifier assigned to this vulnerability.
A vulnerability in the Secure Sockets Layer (SSL) input packet processor of Cisco Small Business 200, 300, and 500 Series Managed Switches could allow an unauthenticated, remote attacker to cause a memory corruption on an affected device. The vulnerability is due to improper validation of HTTPS packets. An attacker could exploit this vulnerability by sending a malformed HTTPS packet to the management web interface of the affected device. A successful exploit could allow the attacker to cause an unexpected reload of the device, resulting in a denial of service (DoS) condition.
The SIP module of some Huawei products have a denial of service (DoS) vulnerability. A remote attacker could exploit these three vulnerabilities by sending the specially crafted messages to the affected device. Due to the insufficient verification of the packets, successful exploit could allow the attacker to cause buffer overflow and dead loop, leading to DoS condition. Affected products can be found in https://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200115-01-sip-en.
php_imap.c in PHP 5.2.5, 5.2.6, 4.x, and other versions, uses obsolete API calls that allow context-dependent attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long IMAP request, which triggers an "rfc822.c legacy routine buffer overflow" error message, related to the rfc822_write_address function.
There is a Mismatched Memory Management Routines vulnerability in the Exiv2::FileIo::seek function of Exiv2 0.26 that will lead to a remote denial of service attack (heap memory corruption) via crafted input.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18291, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18292, CVE-2019-18294, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with network access to the MS3000 Server could trigger a Denial-of-Service condition by sending specifically crafted packets to port 5010/tcp. This vulnerability is independent from CVE-2019-18290, CVE-2019-18291, CVE-2019-18292, CVE-2019-18298, CVE-2019-18299, CVE-2019-18300, CVE-2019-18301, CVE-2019-18302, CVE-2019-18303, CVE-2019-18304, CVE-2019-18305, CVE-2019-18306, and CVE-2019-18307. Please note that an attacker needs to have network access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
A vulnerability has been found in TRENDnet TEW-811DRU 1.0.10.0 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /wireless/security.asp of the component httpd. The manipulation leads to memory corruption. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-219937 was assigned to this vulnerability.
A vulnerability was determined in Nothings stb up to 1.26. The affected element is the function stbtt__buf_get8 in the library stb_truetype.h of the component TTF File Handler. Executing a manipulation can lead to out-of-bounds read. The attack can be executed remotely. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
An issue was discovered in the pam_p11 component 0.2.0 and 0.3.0 for OpenSC. If a smart card creates a signature with a length longer than 256 bytes, this triggers a buffer overflow. This may be the case for RSA keys with 4096 bits depending on the signature scheme.
A vulnerability in the Cisco Fabric Services component of Cisco NX-OS Software could allow an unauthenticated, remote attacker to cause a buffer overflow, resulting in a denial of service (DoS) condition. The vulnerability is due to insufficient validation of Cisco Fabric Services packets. An attacker could exploit this vulnerability by sending a crafted Cisco Fabric Services packet to an affected device. A successful exploit could allow the attacker to cause a buffer overflow, resulting in process crashes and a DoS condition on the device. MDS 9000 Series Multilayer Switches are affected running software versions prior to 6.2(25), 8.1(1b), 8.3(1). Nexus 3000 Series Switches are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 3500 Platform Switches are affected running software versions prior to 6.0(2)A8(10) and 7.0(3)I7(4). Nexus 3600 Platform Switches are affected running software versions prior to 7.0(3)F3(5) Nexus 7000 and 7700 Series Switches are affected running software versions prior to 6.2(22) and 8.2(3). Nexus 9000 Series Switches in Standalone NX-OS Mode are affected running software versions prior to 7.0(3)I4(9) and 7.0(3)I7(4). Nexus 9500 R-Series Line Cards and Fabric Modules are affected running software versions prior to 7.0(3)F3(5). UCS 6200, 6300, and 6400 Fabric Interconnects are affected running software versions prior to 3.2(3j) and 4.0(2a).
A vulnerability in the Independent Computing Architecture (ICA) accelerator feature for the Cisco Wide Area Application Services (WAAS) could allow an unauthenticated, remote attacker to cause an ICA application optimization-related process to restart, resulting in a partial denial of service (DoS) condition. The vulnerability is due to improperly aborting a connection when an unexpected protocol packet is received. An attacker could exploit this vulnerability by sending a crafted ICA traffic through the targeted device. A successful exploit could allow the attacker to cause a DoS condition that is due to a process unexpectedly restarting. The Cisco WAAS could drop ICA traffic while the process is restarting. This vulnerability affects Cisco Wide Area Application Services (WAAS) and Cisco Virtual Wide Area Application Services (vWAAS). Cisco Bug IDs: CSCve74457.
A vulnerability in the implementation of Session Initiation Protocol (SIP) functionality in Cisco Small Business SPA50x, SPA51x, and SPA52x Series IP Phones could allow an unauthenticated, remote attacker to cause an affected device to become unresponsive, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper handling of SIP request messages by an affected device. An attacker could exploit this vulnerability by using formatted specifiers in a SIP payload that is sent to an affected device. A successful exploit could allow the attacker to cause the affected device to become unresponsive, resulting in a DoS condition that persists until the device is restarted manually. This vulnerability affects Cisco Small Business SPA50x, SPA51x, and SPA52x Series IP Phones that are running firmware release 7.6.2SR1 or earlier. Cisco Bug IDs: CSCvc63986.
The ClamAV AntiVirus software versions 0.99.2 and prior contain a vulnerability that could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to a lack of input validation checking mechanisms during certain mail parsing functions (the rfc2047 function in mbox.c). An unauthenticated, remote attacker could exploit this vulnerability by sending a crafted email to the affected device. This action could cause a buffer overflow condition when ClamAV scans the malicious email, allowing the attacker to potentially cause a DoS condition on an affected device.
A vulnerability in the implementation of Session Initiation Protocol (SIP) functionality in Cisco Small Business SPA51x Series IP Phones could allow an unauthenticated, remote attacker to cause an affected device to become unresponsive, resulting in a denial of service (DoS) condition. The vulnerability is due to the improper handling of SIP request messages by an affected device. An attacker could exploit this vulnerability by sending malformed SIP messages to an affected device. A successful exploit could allow the attacker to cause the affected device to become unresponsive, resulting in a DoS condition that persists until the device is restarted manually. This vulnerability affects Cisco Small Business SPA51x Series IP Phones that are running Cisco SPA51x Firmware Release 7.6.2SR1 or earlier. Cisco Bug IDs: CSCvc63982.