Summary
Assigner-mitre
Assigner Org ID-8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At-21 Jan, 2015 | 17:00
Updated At-06 Aug, 2024 | 13:18
Rejected At-
Credits

The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:mitre
Assigner Org ID:8254265b-2729-46b6-b9e3-3dfca2d5bfca
Published At:21 Jan, 2015 | 17:00
Updated At:06 Aug, 2024 | 13:18
Rejected At:
▼CVE Numbering Authority (CNA)

The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
x_refsource_CONFIRM
https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
x_refsource_CONFIRM
Hyperlink: http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
Resource:
x_refsource_CONFIRM
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
Resource:
x_refsource_CONFIRM
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
x_refsource_CONFIRM
x_transferred
https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
x_refsource_CONFIRM
x_transferred
Hyperlink: http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
Resource:
x_refsource_CONFIRM
x_transferred
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
Resource:
x_refsource_CONFIRM
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:cve@mitre.org
Published At:21 Jan, 2015 | 17:59
Updated At:12 Apr, 2025 | 10:46

The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary2.07.8HIGH
AV:N/AC:L/Au:N/C:N/I:N/A:C
Type: Primary
Version: 2.0
Base score: 7.8
Base severity: HIGH
Vector:
AV:N/AC:L/Au:N/C:N/I:N/A:C
CPE Matches

Siemens AG
siemens
>>scalance_x-300_series_firmware>>Versions up to 3.9.3(inclusive)
cpe:2.3:a:siemens:scalance_x-300_series_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x-300>>-
cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x-300eec>>-
cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x-300poe>>-
cpe:2.3:h:siemens:scalance_x-300poe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr-300>>-
cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr-300eec>>-
cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_xr-300poe>>-
cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x-408_firmware>>Versions up to 3.9.3(inclusive)
cpe:2.3:a:siemens:scalance_x-408_firmware:*:*:*:*:*:*:*:*
Siemens AG
siemens
>>scalance_x-408>>*
cpe:2.3:h:siemens:scalance_x-408:*:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-22Primarynvd@nist.gov
CWE ID: CWE-22
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdfcve@mitre.org
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdfcve@mitre.org
N/A
http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdfaf854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdfaf854a3a-2127-422b-91ae-364da2661108
N/A
Hyperlink: http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
Source: cve@mitre.org
Resource:
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
Source: cve@mitre.org
Resource: N/A
Hyperlink: http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Vendor Advisory
Hyperlink: https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A

Change History

0
Information is not available yet

Similar CVEs

125Records found

CVE-2025-27395
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.6||HIGH
EPSS-0.11% / 30.34%
||
7 Day CHG-0.07%
Published-11 Mar, 2025 | 09:48
Updated-22 Aug, 2025 | 18:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the scope of files accessible through and the privileges of the SFTP functionality. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files.

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-27304
Matching Score-6
Assigner-JFrog
ShareView Details
Matching Score-6
Assigner-JFrog
CVSS Score-9.8||CRITICAL
EPSS-1.00% / 76.00%
||
7 Day CHG~0.00%
Published-21 Oct, 2021 | 15:42
Updated-04 Aug, 2024 | 16:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal

Action-Not Available
Vendor-civetweb_projectcivetweb_projectSiemens AG
Product-sinec_infrastructure_network_servicescivetwebcivetweb
CWE ID-CWE-23
Relative Path Traversal
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2014-2732
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.35% / 56.76%
||
7 Day CHG~0.00%
Published-19 Apr, 2014 | 19:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Multiple directory traversal vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to access arbitrary files via HTTP traffic to port (1) 4999 or (2) 80.

Action-Not Available
Vendor-n/aSiemens AG
Product-sinema_servern/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2025-27397
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 15.57%
||
7 Day CHG~0.00%
Published-11 Mar, 2025 | 09:48
Updated-22 Aug, 2025 | 17:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit user controlled paths to which logs are written and from where they are read. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files in the filesystem, if and only if the malicious path ends with 'log' .

Action-Not Available
Vendor-Siemens AG
Product-scalance_lpe9403scalance_lpe9403_firmwareSCALANCE LPE9403
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-33722
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-4.9||MEDIUM
EPSS-0.20% / 42.59%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system has a Path Traversal vulnerability when exporting a firmware container. With this a privileged authenticated attacker could create arbitrary files on an affected system.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-33724
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.1||CRITICAL
EPSS-0.84% / 73.83%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system contains an Arbitrary File Deletion vulnerability that possibly allows to delete an arbitrary file or directory under a user controlled path.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-33726
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-0.45% / 62.51%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 09:49
Updated-03 Aug, 2024 | 23:58
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2 Update 1). The affected system allows to download arbitrary files under a user controlled path and does not correctly check if the relative path is still within the intended target directory.

Action-Not Available
Vendor-Siemens AG
Product-sinec_nmsSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2018-13812
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.5||HIGH
EPSS-7.90% / 91.66%
||
7 Day CHG~0.00%
Published-13 Dec, 2018 | 16:00
Updated-05 Aug, 2024 | 09:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

Action-Not Available
Vendor-Siemens AG
Product-simatic_hmi_ktp_mobile_panels_ktp700fsimatic_hmi_ktp_mobile_panels_ktp900_firmwaresimatic_hmi_tpsimatic_hmi_ktp_mobile_panels_ktp900fsimatic_hmi_tp_firmwaresimatic_hmi_ktp_mobile_panels_ktp400fsimatic_hmi_comfort_outdoor_panelssimatic_hmi_comfort_outdoor_panels_firmwaresimatic_wincc_\(tia_portal\)simatic_hmi_ktp_mobile_panels_ktp700simatic_hmi_ktp_mobile_panels_ktp700f_firmwaresimatic_wincc_runtimesimatic_hmi_op_firmwaresimatic_hmi_mp_firmwaresimatic_hmi_ktp_mobile_panels_ktp900f_firmwaresimatic_hmi_ktp_mobile_panels_ktp400f_firmwaresimatic_hmi_opsimatic_hmi_ktp_mobile_panels_ktp900simatic_hmi_comfort_panelssimatic_hmi_comfort_panels_firmwaresimatic_hmi_mpsimatic_hmi_ktp_mobile_panels_ktp700_firmwareSIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2013-0671
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-4||MEDIUM
EPSS-0.18% / 39.98%
||
7 Day CHG~0.00%
Published-21 Mar, 2013 | 14:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to read HMI web-application source code and user-defined scripts via a crafted URL.

Action-Not Available
Vendor-n/aSiemens AG
Product-wincc_tia_portaln/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-25237
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-8.1||HIGH
EPSS-1.42% / 79.79%
||
7 Day CHG~0.00%
Published-09 Feb, 2021 | 15:38
Updated-04 Aug, 2024 | 15:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1 Update 1), SINEMA Server (All versions < V14.0 SP2 Update 2). When uploading files to an affected system using a zip container, the system does not correctly check if the relative file path of the extracted files is still within the intended target directory. With this an attacker could create or overwrite arbitrary files on an affected system. This type of vulnerability is also known as 'Zip-Slip'. (ZDI-CAN-12054)

Action-Not Available
Vendor-Siemens AG
Product-sinema_serversinec_network_management_systemSINEMA ServerSINEC NMS
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-22651
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.8||HIGH
EPSS-1.71% / 81.58%
||
7 Day CHG~0.00%
Published-23 Feb, 2021 | 17:45
Updated-03 Aug, 2024 | 18:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

When loading a specially crafted file, Luxion KeyShot versions prior to 10.1, Luxion KeyShot Viewer versions prior to 10.1, Luxion KeyShot Network Rendering versions prior to 10.1, and Luxion KeyVR versions prior to 10.1 are, while processing the extraction of temporary files, suffering from a directory traversal vulnerability, which allows an attacker to store arbitrary scripts into automatic startup folders.

Action-Not Available
Vendor-luxionn/aSiemens AG
Product-solid_edge_se2021solid_edge_se2020_firmwarekeyshotsolid_edge_se2021_firmwaresolid_edge_se2020keyvrkeyshot_network_renderingkeyshot_viewerLuxion KeyVRLuxion KeyShot Network RenderingLuxion KeyShot ViewerLuxion KeyShot versions
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-25243
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 15.26%
||
7 Day CHG~0.00%
Published-22 Apr, 2021 | 20:42
Updated-19 Nov, 2024 | 15:01
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in LOGO! Soft Comfort (All versions < V8.4). A zip slip vulnerability could be triggered while importing a compromised project file to the affected software. Chained with other vulnerabilities this vulnerability could ultimately lead to a system takeover by an attacker.

Action-Not Available
Vendor-Siemens AG
Product-logo\!_soft_comfortLOGO! Soft Comfort
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2017-9947
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.3||MEDIUM
EPSS-30.48% / 96.54%
||
7 Day CHG~0.00%
Published-23 Oct, 2017 | 00:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. A directory traversal vulnerability could allow a remote attacker with network access to the integrated web server (80/tcp and 443/tcp) to obtain information on the structure of the file system of the affected devices.

Action-Not Available
Vendor-n/aSiemens AG
Product-talon_tc_compact_firmwaretalon_tc_modular_firmwaretalon_tc_modularapogee_pxctalon_tc_compactapogee_pxc_modularapogee_pxc_modular_firmwareapogee_pxc_firmwareAPOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CWE ID-CWE-538
Insertion of Sensitive Information into Externally-Accessible File or Directory
CVE-2011-4878
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-7.8||HIGH
EPSS-28.23% / 96.32%
||
7 Day CHG~0.00%
Published-03 Feb, 2012 | 20:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.

Action-Not Available
Vendor-n/aSiemens AG
Product-simatic_hmi_panelswincc_flexible_runtimewincc_flexiblewincc_runtime_advancedwinccn/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2011-4532
Matching Score-6
Assigner-CERT/CC
ShareView Details
Matching Score-6
Assigner-CERT/CC
CVSS Score-5||MEDIUM
EPSS-8.07% / 91.78%
||
7 Day CHG~0.00%
Published-08 Jan, 2012 | 20:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.

Action-Not Available
Vendor-n/aSiemens AG
Product-automation_license_managern/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-40359
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-7.7||HIGH
EPSS-0.47% / 63.57%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_route_controlsimaticpcs_7simatic_net_pcsimatic_batchSIMATIC NET PC Software V14SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC NET PC Software V15SIMATIC PCS 7 V9.0SIMATIC PCS 7 V9.1OpenPCS 7 V9.0SIMATIC BATCH V9.1OpenPCS 7 V8.2SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC Route Control V9.1SIMATIC BATCH V8.2SIMATIC Route Control V8.2SIMATIC Route Control V9.0OpenPCS 7 V9.1SIMATIC NET PC Software V16SIMATIC BATCH V9.0SIMATIC WinCC V16SIMATIC PCS 7 V8.2SIMATIC NET PC Software V17
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-40358
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.9||CRITICAL
EPSS-0.58% / 67.83%
||
7 Day CHG~0.00%
Published-09 Nov, 2021 | 11:32
Updated-04 Aug, 2024 | 02:44
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.

Action-Not Available
Vendor-Siemens AG
Product-simatic_winccsimatic_pcs_7SIMATIC WinCC V15 and earlierSIMATIC WinCC V17SIMATIC PCS 7 V9.1SIMATIC PCS 7 V9.0SIMATIC WinCC V7.4SIMATIC WinCC V7.5SIMATIC WinCC V16SIMATIC PCS 7 V8.2
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-50559
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-5.1||MEDIUM
EPSS-0.05% / 14.47%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:50
Updated-13 Nov, 2024 | 19:56
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2). Affected devices do not properly validate the filenames of the certificate. This could allow an authenticated remote attacker to append arbitrary values which will lead to compromise of integrity of the system.

Action-Not Available
Vendor-Siemens AG
Product-scalance_mum856-1_\(eu\)ruggedcom_rm1224_lte\(4g\)_nam_firmwarescalance_mum856-1_\(b1\)_firmwarescalance_m874-2_firmwarescalance_m874-3scalance_m874-3_\(cn\)scalance_m876-4_\(eu\)ruggedcom_rm1224_lte\(4g\)_euscalance_m812-1_\(annex_b\)scalance_m812-1_\(annex_a\)scalance_mum856-1_\(b1\)scalance_m876-4_\(nam\)scalance_m804pb_firmwarescalance_s615scalance_m874-3_firmwarescalance_m876-3_firmwarescalance_mum853-1_\(b1\)scalance_mum853-1_\(eu\)ruggedcom_rm1224_lte\(4g\)_namscalance_m876-3_\(rok\)_firmwarescalance_m874-3_\(cn\)_firmwarescalance_mum853-1_\(b1\)_firmwarescalance_mum856-1_\(cn\)scalance_s615_firmwarescalance_mum856-1_\(a1\)_firmwarescalance_mum856-1_\(a1\)scalance_mum856-1_\(row\)scalance_m876-3_\(rok\)scalance_mum856-1_\(eu\)_firmwarescalance_mum856-1_\(cn\)_firmwarescalance_m876-3scalance_m876-4_\(eu\)_firmwarescalance_m816-1_\(annex_b\)scalance_m876-4scalance_m876-4_firmwarescalance_mum853-1_\(a1\)_firmwarescalance_s615_eec_firmwarescalance_m826-2scalance_m812-1_\(annex_a\)_firmwarescalance_s615_eecscalance_m874-2scalance_m826-2_firmwarescalance_mum856-1_\(row\)_firmwarescalance_m816-1_\(annex_b\)_firmwarescalance_m804pbscalance_m876-4_\(nam\)_firmwarescalance_m812-1_\(annex_b\)_firmwarescalance_m816-1_\(annex_a\)_firmwarescalance_mum853-1_\(eu\)_firmwarescalance_mum853-1_\(a1\)ruggedcom_rm1224_lte\(4g\)_eu_firmwarescalance_m816-1_\(annex_a\)SCALANCE M874-3 3G-Router (CN)SCALANCE M874-3SCALANCE MUM856-1 (B1)SCALANCE M816-1 ADSL-RouterSCALANCE M876-3 (ROK)SCALANCE MUM856-1 (A1)SCALANCE M812-1 ADSL-RouterSCALANCE M804PBSCALANCE MUM856-1 (EU)SCALANCE MUM853-1 (B1)SCALANCE MUM853-1 (EU)SCALANCE S615 EEC LAN-RouterSCALANCE M874-2SCALANCE M876-4RUGGEDCOM RM1224 LTE(4G) NAMSCALANCE M876-3SCALANCE M826-2 SHDSL-RouterSCALANCE MUM856-1 (CN)SCALANCE MUM856-1 (RoW)RUGGEDCOM RM1224 LTE(4G) EUSCALANCE M876-4 (EU)SCALANCE MUM853-1 (A1)SCALANCE M876-4 (NAM)SCALANCE S615 LAN-Router
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-37734
Matching Score-6
Assigner-Hewlett Packard Enterprise (HPE)
ShareView Details
Matching Score-6
Assigner-Hewlett Packard Enterprise (HPE)
CVSS Score-6.5||MEDIUM
EPSS-0.48% / 64.33%
||
7 Day CHG~0.00%
Published-12 Oct, 2021 | 15:16
Updated-04 Aug, 2024 | 01:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A remote unauthorized read access to files vulnerability was discovered in Aruba Instant version(s): 6.4.x.x: 6.4.4.8-4.2.4.18 and below; Aruba Instant 6.5.x.x: 6.5.4.19 and below; Aruba Instant 8.5.x.x: 8.5.0.12 and below; Aruba Instant 8.6.x.x: 8.6.0.11 and below; Aruba Instant 8.7.x.x: 8.7.1.3 and below; Aruba Instant 8.8.x.x: 8.8.0.0 and below. Aruba has released patches for Aruba Instant (IAP) that address this security vulnerability.

Action-Not Available
Vendor-n/aSiemens AGAruba Networks
Product-aruba_instantscalance_w1750d_firmwarescalance_w1750dHPE Aruba Instant (IAP)
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2021-37701
Matching Score-6
Assigner-GitHub, Inc.
ShareView Details
Matching Score-6
Assigner-GitHub, Inc.
CVSS Score-8.2||HIGH
EPSS-0.03% / 6.45%
||
7 Day CHG~0.00%
Published-31 Aug, 2021 | 00:00
Updated-04 Aug, 2024 | 01:23
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Arbitrary File Creation/Overwrite via insufficient symlink protection due to directory cache poisoning using symbolic links

The npm package "tar" (aka node-tar) before versions 4.4.16, 5.0.8, and 6.1.7 has an arbitrary file creation/overwrite and arbitrary code execution vulnerability. node-tar aims to guarantee that any file whose location would be modified by a symbolic link is not extracted. This is, in part, achieved by ensuring that extracted directories are not symlinks. Additionally, in order to prevent unnecessary stat calls to determine whether a given path is a directory, paths are cached when directories are created. This logic was insufficient when extracting tar files that contained both a directory and a symlink with the same name as the directory, where the symlink and directory names in the archive entry used backslashes as a path separator on posix systems. The cache checking logic used both `\` and `/` characters as path separators, however `\` is a valid filename character on posix systems. By first creating a directory, and then replacing that directory with a symlink, it was thus possible to bypass node-tar symlink checks on directories, essentially allowing an untrusted tar file to symlink into an arbitrary location and subsequently extracting arbitrary files into that location, thus allowing arbitrary file creation and overwrite. Additionally, a similar confusion could arise on case-insensitive filesystems. If a tar archive contained a directory at `FOO`, followed by a symbolic link named `foo`, then on case-insensitive file systems, the creation of the symbolic link would remove the directory from the filesystem, but _not_ from the internal directory cache, as it would not be treated as a cache hit. A subsequent file entry within the `FOO` directory would then be placed in the target of the symbolic link, thinking that the directory had already been created. These issues were addressed in releases 4.4.16, 5.0.8 and 6.1.7. The v3 branch of node-tar has been deprecated and did not receive patches for these issues. If you are still using a v3 release we recommend you update to a more recent version of node-tar. If this is not possible, a workaround is available in the referenced GHSA-9r2w-394v-53qc.

Action-Not Available
Vendor-npmjsnpmDebian GNU/LinuxOracle CorporationSiemens AG
Product-sinec_infrastructure_network_servicesdebian_linuxtargraalvmnode-tar
CWE ID-CWE-59
Improper Link Resolution Before File Access ('Link Following')
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-46888
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-9.4||CRITICAL
EPSS-1.45% / 79.98%
||
7 Day CHG~0.00%
Published-12 Nov, 2024 | 12:49
Updated-13 Nov, 2024 | 23:11
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly sanitize user provided paths for SFTP-based file up- and downloads. This could allow an authenticated remote attacker to manipulate arbitrary files on the filesystem and achieve arbitrary code execution on the device.

Action-Not Available
Vendor-Siemens AG
Product-sinec_insSINEC INSsinec_ins
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2024-47563
Matching Score-6
Assigner-Siemens
ShareView Details
Matching Score-6
Assigner-Siemens
CVSS Score-6.9||MEDIUM
EPSS-0.25% / 48.43%
||
7 Day CHG~0.00%
Published-08 Oct, 2024 | 08:40
Updated-11 Oct, 2024 | 20:05
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly validate a file path that is supplied to an endpoint intended to create CSR files. This could allow an unauthenticated remote attacker to create files in writable directories outside the intended location and thus compromise integrity of files in those writable directories.

Action-Not Available
Vendor-Siemens AG
Product-sinec_security_monitorSiemens SINEC Security Monitorsinec_security_monitor
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2009-0680
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-19.93% / 95.25%
||
7 Day CHG~0.00%
Published-22 Feb, 2009 | 22:00
Updated-07 Aug, 2024 | 04:40
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

cgi-bin/welcome/VPN_only in the web interface in Netgear SSL312 allows remote attackers to cause a denial of service (device crash) via a crafted query string, as demonstrated using directory traversal sequences.

Action-Not Available
Vendor-n/aNETGEAR, Inc.
Product-ssl312n/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2020-3249
Matching Score-4
Assigner-Cisco Systems, Inc.
ShareView Details
Matching Score-4
Assigner-Cisco Systems, Inc.
CVSS Score-9.8||CRITICAL
EPSS-21.04% / 95.43%
||
7 Day CHG~0.00%
Published-15 Apr, 2020 | 20:10
Updated-15 Nov, 2024 | 17:30
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Multiple Vulnerabilities in Cisco UCS Director and Cisco UCS Director Express for Big Data

Multiple vulnerabilities in the REST API of Cisco UCS Director and Cisco UCS Director Express for Big Data may allow a remote attacker to bypass authentication or conduct directory traversal attacks on an affected device. For more information about these vulnerabilities, see the Details section of this advisory.

Action-Not Available
Vendor-Cisco Systems, Inc.
Product-ucs_directorucs_director_express_for_big_dataCisco UCS Director
CWE ID-CWE-20
Improper Input Validation
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
CVE-2008-3149
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.8||HIGH
EPSS-0.41% / 60.71%
||
7 Day CHG~0.00%
Published-11 Jul, 2008 | 18:00
Updated-07 Aug, 2024 | 09:28
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The SNMP daemon in the F5 FirePass 1200 6.0.2 hotfix 3 allows remote attackers to cause a denial of service (daemon crash) by walking the hrSWInstalled OID branch in HOST-RESOURCES-MIB.

Action-Not Available
Vendor-n/aF5, Inc.
Product-firepass_1200n/a
CWE ID-CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
  • Previous
  • 1
  • 2
  • 3
  • Next
Details not found