Logo
-

Byte Open Security

(ByteOS Network)

Log In

Sign Up

ByteOS

Security
Vulnerability Details
Registries
Custom Views
Weaknesses
Attack Patterns
Filters & Tools
Vulnerability Details :

CVE-2016-2286

Summary
Assigner-icscert
Assigner Org ID-7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At-31 May, 2016 | 01:00
Updated At-05 Aug, 2024 | 23:24
Rejected At-
Credits

Moxa MiiNePort_E1_4641 devices with firmware 1.1.10 Build 09120714, MiiNePort_E1_7080 devices with firmware 1.1.10 Build 09120714, MiiNePort_E2_1242 devices with firmware 1.1 Build 10080614, MiiNePort_E2_4561 devices with firmware 1.1 Build 10080614, and MiiNePort E3 devices with firmware 1.0 Build 11071409 have a blank default password, which allows remote attackers to obtain access via unspecified vectors.

Vendors
-
Not available
Products
-
Metrics (CVSS)
VersionBase scoreBase severityVector
Weaknesses
Attack Patterns
Solution/Workaround
References
HyperlinkResource Type
EPSS History
Score
Latest Score
-
N/A
No data available for selected date range
Percentile
Latest Percentile
-
N/A
No data available for selected date range
Stakeholder-Specific Vulnerability Categorization (SSVC)
▼Common Vulnerabilities and Exposures (CVE)
cve.org
Assigner:icscert
Assigner Org ID:7d14cffa-0d7d-4270-9dc0-52cabd5a23a6
Published At:31 May, 2016 | 01:00
Updated At:05 Aug, 2024 | 23:24
Rejected At:
▼CVE Numbering Authority (CNA)

Moxa MiiNePort_E1_4641 devices with firmware 1.1.10 Build 09120714, MiiNePort_E1_7080 devices with firmware 1.1.10 Build 09120714, MiiNePort_E2_1242 devices with firmware 1.1 Build 10080614, MiiNePort_E2_4561 devices with firmware 1.1 Build 10080614, and MiiNePort E3 devices with firmware 1.0 Build 11071409 have a blank default password, which allows remote attackers to obtain access via unspecified vectors.

Affected Products
Vendor
n/a
Product
n/a
Versions
Affected
  • n/a
Problem Types
TypeCWE IDDescription
textN/An/a
Type: text
CWE ID: N/A
Description: n/a
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://seclists.org/fulldisclosure/2016/May/7
mailing-list
x_refsource_FULLDISC
https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
x_refsource_MISC
Hyperlink: http://seclists.org/fulldisclosure/2016/May/7
Resource:
mailing-list
x_refsource_FULLDISC
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
Resource:
x_refsource_MISC
▼Authorized Data Publishers (ADP)
CVE Program Container
Affected Products
Metrics
VersionBase scoreBase severityVector
Metrics Other Info
Impacts
CAPEC IDDescription
Solutions

Configurations

Workarounds

Exploits

Credits

Timeline
EventDate
Replaced By

Rejected Reason

References
HyperlinkResource
http://seclists.org/fulldisclosure/2016/May/7
mailing-list
x_refsource_FULLDISC
x_transferred
https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
x_refsource_MISC
x_transferred
Hyperlink: http://seclists.org/fulldisclosure/2016/May/7
Resource:
mailing-list
x_refsource_FULLDISC
x_transferred
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
Resource:
x_refsource_MISC
x_transferred
Information is not available yet
▼National Vulnerability Database (NVD)
nvd.nist.gov
Source:ics-cert@hq.dhs.gov
Published At:31 May, 2016 | 01:59
Updated At:12 Apr, 2025 | 10:46

Moxa MiiNePort_E1_4641 devices with firmware 1.1.10 Build 09120714, MiiNePort_E1_7080 devices with firmware 1.1.10 Build 09120714, MiiNePort_E2_1242 devices with firmware 1.1 Build 10080614, MiiNePort_E2_4561 devices with firmware 1.1 Build 10080614, and MiiNePort E3 devices with firmware 1.0 Build 11071409 have a blank default password, which allows remote attackers to obtain access via unspecified vectors.

CISA Catalog
Date AddedDue DateVulnerability NameRequired Action
N/A
Date Added: N/A
Due Date: N/A
Vulnerability Name: N/A
Required Action: N/A
Metrics
TypeVersionBase scoreBase severityVector
Primary3.07.5HIGH
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary2.05.0MEDIUM
AV:N/AC:L/Au:N/C:P/I:N/A:N
Type: Primary
Version: 3.0
Base score: 7.5
Base severity: HIGH
Vector:
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Type: Primary
Version: 2.0
Base score: 5.0
Base severity: MEDIUM
Vector:
AV:N/AC:L/Au:N/C:P/I:N/A:N
CPE Matches

Moxa Inc.
moxa
>>miineport_e2_1242>>-
cpe:2.3:h:moxa:miineport_e2_1242:-:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e2_1242_firmware>>1.1
cpe:2.3:o:moxa:miineport_e2_1242_firmware:1.1:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e1_7080>>-
cpe:2.3:h:moxa:miineport_e1_7080:-:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e1_7080_firmware>>1.1.10
cpe:2.3:o:moxa:miineport_e1_7080_firmware:1.1.10:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e2_4561>>-
cpe:2.3:h:moxa:miineport_e2_4561:-:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e2_4561_firmware>>1.1
cpe:2.3:o:moxa:miineport_e2_4561_firmware:1.1:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e3>>-
cpe:2.3:h:moxa:miineport_e3:-:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e3_firmware>>1.0
cpe:2.3:o:moxa:miineport_e3_firmware:1.0:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e1_4641>>-
cpe:2.3:h:moxa:miineport_e1_4641:-:*:*:*:*:*:*:*
Moxa Inc.
moxa
>>miineport_e1_4641_firmware>>1.1.10
cpe:2.3:o:moxa:miineport_e1_4641_firmware:1.1.10:*:*:*:*:*:*:*
Weaknesses
CWE IDTypeSource
CWE-287Primarynvd@nist.gov
CWE ID: CWE-287
Type: Primary
Source: nvd@nist.gov
Evaluator Description

Evaluator Impact

Evaluator Solution

Vendor Statements

References
HyperlinkSourceResource
http://seclists.org/fulldisclosure/2016/May/7ics-cert@hq.dhs.gov
N/A
https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01ics-cert@hq.dhs.gov
Third Party Advisory
US Government Resource
http://seclists.org/fulldisclosure/2016/May/7af854a3a-2127-422b-91ae-364da2661108
N/A
https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01af854a3a-2127-422b-91ae-364da2661108
Third Party Advisory
US Government Resource
Hyperlink: http://seclists.org/fulldisclosure/2016/May/7
Source: ics-cert@hq.dhs.gov
Resource: N/A
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
Source: ics-cert@hq.dhs.gov
Resource:
Third Party Advisory
US Government Resource
Hyperlink: http://seclists.org/fulldisclosure/2016/May/7
Source: af854a3a-2127-422b-91ae-364da2661108
Resource: N/A
Hyperlink: https://ics-cert.us-cert.gov/advisories/ICSA-16-145-01
Source: af854a3a-2127-422b-91ae-364da2661108
Resource:
Third Party Advisory
US Government Resource

Change History

0
Information is not available yet

Similar CVEs

335Records found

CVE-2016-0876
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.42%
||
7 Day CHG~0.00%
Published-31 May, 2016 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Moxa Secure Router EDR-G903 devices before 3.4.12 allow remote attackers to discover cleartext passwords by reading a configuration file.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-edr-g903_firmwareedr-g903n/a
CWE ID-CWE-312
Cleartext Storage of Sensitive Information
CVE-2020-6997
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.15% / 35.93%
||
7 Day CHG~0.00%
Published-24 Mar, 2020 | 20:31
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Moxa EDS-G516E Series firmware, Version 5.2 or lower, sensitive information is transmitted over some web applications in cleartext.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-eds-g516e_firmwareeds-g516eeds-510e_firmwareeds-510eMoxa EDS-G516E Series firmware, Version 5.2 or lower
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2016-2283
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.42% / 61.01%
||
7 Day CHG~0.00%
Published-04 Mar, 2016 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt data, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-iologik_firmwareiologik_e2210-tiologik_e2212-tiologik_e2242-tiologik_e2260iologik_e2214iologik_e2262iologik_e2240-tioadmin_firmwareiologik_e2242iologik_e2262-tiologik_e2260-tiologik_e2214-tiologik_e2240iologik_e2212iologik_e2210n/a
CVE-2016-2295
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.75% / 72.12%
||
7 Day CHG~0.00%
Published-31 May, 2016 | 01:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Moxa MiiNePort_E1_4641 devices with firmware 1.1.10 Build 09120714, MiiNePort_E1_7080 devices with firmware 1.1.10 Build 09120714, MiiNePort_E2_1242 devices with firmware 1.1 Build 10080614, MiiNePort_E2_4561 devices with firmware 1.1 Build 10080614, and MiiNePort E3 devices with firmware 1.0 Build 11071409 allow remote attackers to obtain sensitive cleartext information by reading a configuration file.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-miineport_e1_4641_firmwaremiineport_e2_1242_firmwaremiineport_e3miineport_e1_7080miineport_e3_firmwaremiineport_e2_4561miineport_e1_7080_firmwaremiineport_e2_1242miineport_e2_4561_firmwaremiineport_e1_4641n/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2016-2282
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-5.3||MEDIUM
EPSS-0.57% / 67.58%
||
7 Day CHG~0.00%
Published-04 Mar, 2016 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Moxa ioLogik E2200 devices before 3.12 and ioAdmin Configuration Utility before 3.18 do not properly encrypt credentials, which makes it easier for remote attackers to obtain the associated cleartext via unspecified vectors.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-iologik_firmwareiologik_e2210-tiologik_e2212-tiologik_e2242-tiologik_e2260iologik_e2214iologik_e2262iologik_e2240-tioadmin_firmwareiologik_e2242iologik_e2262-tiologik_e2260-tiologik_e2214-tiologik_e2240iologik_e2212iologik_e2210n/a
CVE-2017-7455
Matching Score-8
Assigner-MITRE Corporation
ShareView Details
Matching Score-8
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-39.99% / 97.23%
||
7 Day CHG~0.00%
Published-14 Apr, 2017 | 14:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-mxviewn/a
CWE ID-CWE-200
Exposure of Sensitive Information to an Unauthorized Actor
CVE-2020-7003
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.15% / 35.93%
||
7 Day CHG~0.00%
Published-24 Mar, 2020 | 17:02
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is transmitted over some web applications in clear text.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-iologik_2512-wl1-eu-t_firmwareiologik_2542-wl1-jpiologik_2542-wl1-jp-t_firmwareiologik_2512iologik_2512-t_firmwareiologik_2512-tiologik_2542-wl1-jp_firmwareiologik_2512-wl1-jp-t_firmwareiologik_2512-wl1-jp-tiologik_2542_firmwareiologik_2542-wl1-usiologik_2512-wl1-usiologik_2512-hspa-tiologik_2512-wl1-jp_firmwareiologik_2542-wl1-eu_firmwareiologik_2542-hspa_firmwareiologik_2542-wl1-jp-tiologik_2512-wl1-eu-tiologik_2542-t_firmwareiologik_2542-wl1-eu-t_firmwareiologik_2542-wl1-us-tiologik_2512-hspa-t_firmwareiologik_2512_firmwareiologik_2512-wl1-us-t_firmwareiologik_2542-wl1-eu-tiologik_2542-wl1-euiologik_2512-wl1-us-tiologik_2542-wl1-us-t_firmwareiologik_2542-tiologik_2512-wl1-eu_firmwareiologik_2512-wl1-euiologik_2542-hspaiologik_2512-wl1-jpiologik_2512-wl1-us_firmwareiologik_2542-wl1-us_firmwareiologik_2542-hspa-t_firmwareiologik_2512-hspaiologik_2542iologik_2512-hspa_firmwareiologik_2542-hspa-tMoxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower
CWE ID-CWE-319
Cleartext Transmission of Sensitive Information
CVE-2020-7001
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-8
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-0.15% / 35.93%
||
7 Day CHG~0.00%
Published-24 Mar, 2020 | 20:15
Updated-04 Aug, 2024 | 09:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a weak cryptographic algorithm, which may allow confidential information to be disclosed.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-eds-g516e_firmwareeds-g516eeds-510e_firmwareeds-510eMoxa EDS-G516E Series firmware, Version 5.2 or lower
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CVE-2016-9369
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-7.40% / 91.35%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Firmware can be updated over the network without authentication, which may allow remote code execution.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-nport_5450nport_5610nport_5100a_series_firmwarenport_5430nport_5232nport_5410nport_5250a1-m12-ctnport_5430inport_5450i-tnport_5200_series_firmwarenport_5150anport_6100_series_firmwarenport_5630nport_p5110anport_5150a1-m12-tnport_5250a1-m12-tnport_5450a1-m12-ctnport_5650i-8-dtlnport_5130nport_5150nport_5210nport_5650-8-dtlnport_5150a1-m12-ctnport_5250anport_5150a1-m12-ct-tnport_5200a_series_firmwarenport_5230anport_p5150a_series_firmwarenport_5450a1-m12-ct-tnport_5250a1-m12-ct-tnport_5232inport_5450a1-m12nport_6150-tnport_5110anport_5600-8-dtl_series_firmwarenport_5400_series_firmwarenport_5450inport_5610-8-dtlnport_5650nport_5130anport_5450a1-m12-tnport_5600_series_firmwarenport_5150a1-m12nport_5230nport_5210anport_5x50a1-m12_series_firmwarenport_5450-tnport_6150nport_5100_series_firmwarenport_5110nport_5250a1-m12Moxa NPort
CWE ID-CWE-287
Improper Authentication
CVE-2016-9361
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-50.81% / 97.77%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Administration passwords can be retried without authenticating.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-nport_5450nport_5610nport_5100a_series_firmwarenport_5430nport_5232nport_5410nport_5250a1-m12-ctnport_5430inport_5450i-tnport_5200_series_firmwarenport_5150anport_6100_series_firmwarenport_5630nport_p5110anport_5150a1-m12-tnport_5250a1-m12-tnport_5450a1-m12-ctnport_5650i-8-dtlnport_5130nport_5150nport_5210nport_5650-8-dtlnport_5150a1-m12-ctnport_5250anport_5150a1-m12-ct-tnport_5200a_series_firmwarenport_5230anport_p5150a_series_firmwarenport_5450a1-m12-ct-tnport_5250a1-m12-ct-tnport_5232inport_5450a1-m12nport_6150-tnport_5110anport_5600-8-dtl_series_firmwarenport_5400_series_firmwarenport_5450inport_5610-8-dtlnport_5650nport_5130anport_5450a1-m12-tnport_5600_series_firmwarenport_5150a1-m12nport_5230nport_5210anport_5x50a1-m12_series_firmwarenport_5450-tnport_6150nport_5100_series_firmwarenport_5110nport_5250a1-m12Moxa NPort
CWE ID-CWE-287
Improper Authentication
CVE-2016-8362
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-6.5||MEDIUM
EPSS-0.16% / 37.46%
||
7 Day CHG~0.00%
Published-13 Feb, 2017 | 21:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. Any user is able to download log files by accessing a specific URL.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-wac-2004awk-1131a_firmwareoncellg3470a-lte_firmwareawk-5232awk-5232-m12-rcc_firmwareawk-3131-m12-rccawk-3121-m12-rtg_firmwareawk-3121-m12-rtgawk-4131aawk-5232-m12-rccawk-3131aawk-3131-m12-rcc_firmwareawk-3191_firmwareawk-1127_firmwareawk-4131a_firmwareawk-6232_firmwareawk-1121_firmwareawk-1121wac-1001_v2awk-3191oncellg3470a-lteawk-1127wac-2004_firmwareawk-5232_firmwareawk-1131aawk-3131a_firmwarewac-1001_v2_firmwareawk-6232Moxa OnCell
CWE ID-CWE-287
Improper Authentication
CVE-2019-5165
Matching Score-6
Assigner-Talos
ShareView Details
Matching Score-6
Assigner-Talos
CVSS Score-8||HIGH
EPSS-0.15% / 35.58%
||
7 Day CHG~0.00%
Published-25 Feb, 2020 | 15:49
Updated-04 Aug, 2024 | 19:47
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An exploitable authentication bypass vulnerability exists in the hostname processing of the Moxa AWK-3131A firmware version 1.13. A specially configured device hostname can cause the device to interpret select remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-awk-3131aawk-3131a_firmwareMoxa
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-287
Improper Authentication
CVE-2018-5455
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.47% / 63.64%
||
7 Day CHG~0.00%
Published-05 Mar, 2018 | 17:00
Updated-05 Aug, 2024 | 05:33
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A Reliance on Cookies without Validation and Integrity Checking issue was discovered in Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. The application allows a cookie parameter to consist of only digits, allowing an attacker to perform a brute force attack bypassing authentication and gaining access to device functions.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-oncell_g3150-hspa_firmwareoncell_g3110-hspa-toncell_g3150-hspa-toncell_g3110-hspa-t_firmwareoncell_g3110-hspaoncell_g3150-hspa-t_firmwareoncell_g3150-hspaoncell_g3110-hspa_firmwareMoxa OnCell G3100-HSPA Series
CWE ID-CWE-565
Reliance on Cookies without Validation and Integrity Checking
CWE ID-CWE-287
Improper Authentication
CVE-2023-5627
Matching Score-6
Assigner-Moxa Inc.
ShareView Details
Matching Score-6
Assigner-Moxa Inc.
CVSS Score-7.5||HIGH
EPSS-0.08% / 23.52%
||
7 Day CHG~0.00%
Published-01 Nov, 2023 | 15:04
Updated-05 Sep, 2024 | 15:45
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Incorrect Implementation of Authentication Algorithm Vulnerability

A vulnerability has been identified in NPort 6000 Series, making the authentication mechanism vulnerable. This vulnerability arises from the incorrect implementation of sensitive information protection, potentially allowing malicious users to gain unauthorized access to the web service.

Action-Not Available
Vendor-Moxa Inc.
Product-nport_6610-32_firmwarenport_6650-32-hv-t_firmwarenport_6450_firmwarenport_6650-8_firmwarenport_6650-16-t_firmwarenport_6250-s-sc_firmwarenport_6150nport_6610-8-48vnport_6650-16-hv-tnport_6650-32-hv-tnport_6650-8-tnport_6250nport_6610-16_firmwarenport_6450-t_firmwarenport_6250_firmwarenport_6610-16-48vnport_6150_firmwarenport_6250-s-sc-tnport_6650-8-hv-tnport_6250-m-sc-t_firmwarenport_6650-16-tnport_6650-32-48v_firmwarenport_6650-32-48vnport_6450nport_6610-8_firmwarenport_6610-32-48v_firmwarenport_6650-16-hv-t_firmwarenport_6450-tnport_6150-t_firmwarenport_6250-tnport_6250-s-sc-t_firmwarenport_6250-s-scnport_6610-32-48vnport_6610-32nport_6250-t_firmwarenport_6650-8-48vnport_6650-8-hv-t_firmwarenport_6610-16-48v_firmwarenport_6650-16-48v_firmwarenport_6250-m-sc_firmwarenport_6610-8nport_6150-tnport_6650-16nport_6650-8nport_6650-16_firmwarenport_6610-16nport_6650-32_firmwarenport_6650-8-48v_firmwarenport_6650-8-t_firmwarenport_6650-16-48vnport_6650-32nport_6250-m-sc-tnport_6610-8-48v_firmwarenport_6250-m-scNPort 6000 Seriesnport_6000
CWE ID-CWE-303
Incorrect Implementation of Authentication Algorithm
CWE ID-CWE-257
Storing Passwords in a Recoverable Format
CWE ID-CWE-327
Use of a Broken or Risky Cryptographic Algorithm
CWE ID-CWE-287
Improper Authentication
CVE-2018-11426
Matching Score-6
Assigner-MITRE Corporation
ShareView Details
Matching Score-6
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.43% / 61.35%
||
7 Day CHG-0.02%
Published-03 Jul, 2019 | 14:50
Updated-05 Aug, 2024 | 08:10
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

A weak Cookie parameter is used in the web application of Moxa OnCell G3100-HSPA Series version 1.4 Build 16062919 and prior. An attacker can brute force parameters required to bypass authentication and access the web interface to use all its functions except for password change.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-oncell_g3150-hspa-t_firmwareoncell_g3150-hspaoncell_g3150-hspa_firmwareoncell_g3150-hspa-tn/a
CWE ID-CWE-287
Improper Authentication
CVE-2023-39981
Matching Score-6
Assigner-Moxa Inc.
ShareView Details
Matching Score-6
Assigner-Moxa Inc.
CVSS Score-7.5||HIGH
EPSS-0.22% / 45.10%
||
7 Day CHG~0.00%
Published-02 Sep, 2023 | 12:25
Updated-28 Oct, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
MXsecurity Device Information Disclosure

A vulnerability that allows for unauthorized access has been discovered in MXsecurity versions prior to v1.0.1. This vulnerability arises from inadequate authentication measures, potentially leading to the disclosure of device information by a remote attacker.

Action-Not Available
Vendor-Moxa Inc.
Product-mxsecurityMXsecurity Series
CWE ID-CWE-306
Missing Authentication for Critical Function
CWE ID-CWE-287
Improper Authentication
CVE-2023-33237
Matching Score-6
Assigner-Moxa Inc.
ShareView Details
Matching Score-6
Assigner-Moxa Inc.
CVSS Score-8.8||HIGH
EPSS-0.29% / 52.16%
||
7 Day CHG~0.00%
Published-17 Aug, 2023 | 01:50
Updated-28 Oct, 2024 | 06:15
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Authentication Bypass Without Administrator Privilege

TN-5900 Series firmware version v3.3 and prior is vulnerable to improper-authentication vulnerability. This vulnerability arises from inadequate authentication measures implemented in the web API handler, allowing low-privileged APIs to execute restricted actions that only high-privileged APIs are allowed This presents a potential risk of unauthorized exploitation by malicious actors.

Action-Not Available
Vendor-Moxa Inc.
Product-tn-5900_firmwaretn-5900TN-5900 Seriestn-5900
CWE ID-CWE-863
Incorrect Authorization
CWE ID-CWE-287
Improper Authentication
CVE-2015-6480
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-6
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-8.3||HIGH
EPSS-0.25% / 47.71%
||
7 Day CHG~0.00%
Published-21 Dec, 2015 | 11:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The MessageBrokerServlet servlet in Moxa OnCell Central Manager before 2.2 does not require authentication, which allows remote attackers to obtain administrative access via a command, as demonstrated by the addUserAndGroup action.

Action-Not Available
Vendor-n/aMoxa Inc.
Product-oncell_central_managern/a
CWE ID-CWE-287
Improper Authentication
CVE-2002-0563
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-34.45% / 96.85%
||
7 Day CHG+3.60%
Published-11 Jun, 2002 | 04:00
Updated-03 Apr, 2025 | 01:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The default configuration of Oracle 9i Application Server 1.0.2.x allows remote anonymous users to access sensitive services without authentication, including Dynamic Monitoring Services (1) dms0, (2) dms/DMSDump, (3) servlet/DMSDump, (4) servlet/Spy, (5) soap/servlet/Spy, and (6) dms/AggreSpy; and Oracle Java Process Manager (7) oprocmgr-status and (8) oprocmgr-service, which can be used to control Java processes.

Action-Not Available
Vendor-n/aOracle Corporation
Product-oracle8iapplication_serverapplication_server_web_cacheoracle9in/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-1596
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-21.88% / 95.55%
||
7 Day CHG~0.00%
Published-24 Jan, 2020 | 17:53
Updated-06 Aug, 2024 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Authentication Bypass Vulnerability exists in Vivotek PT7135 IP Camera 0300a and 0400a via specially crafted RTSP packets to TCP port 554.

Action-Not Available
Vendor-vivotekn/a
Product-pt7135_firmwarept7135n/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-7314
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-8.85% / 92.18%
||
7 Day CHG~0.00%
Published-07 Jun, 2017 | 13:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An issue was discovered in Personify360 e-Business 7.5.2 through 7.6.1. When going to the /TabId/275 URI, while creating a new role, a list of database tables and their columns is available.

Action-Not Available
Vendor-personifyn/a
Product-personify360_e-businessn/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-1600
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5.3||MEDIUM
EPSS-72.69% / 98.72%
||
7 Day CHG~0.00%
Published-28 Jan, 2020 | 20:19
Updated-06 Aug, 2024 | 15:04
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Authentication Bypass vulnerability exists in upnp/asf-mp4.asf when streaming live video in D-Link TESCO DCS-2121 1.05_TESCO, TESCO DCS-2102 1.05_TESCO, DCS-2121 1.06_FR, 1.06, and 1.05_RU, DCS-2102 1.06_FR. 1.06, and 1.05_RU, which could let a malicious user obtain sensitive information.

Action-Not Available
Vendor-n/aD-Link Corporation
Product-dcs-2121_firmwaredcs-2102_firmwaredcs-2121dcs-2102n/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-2056
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-5||MEDIUM
EPSS-0.38% / 58.45%
||
7 Day CHG~0.00%
Published-31 Jul, 2013 | 10:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Inter-Satellite Sync (ISS) operation in Red Hat Network (RHN) Satellite 5.3, 5.4, and 5.5 does not properly check client "authenticity," which allows remote attackers to obtain channel content by skipping the initial authentication call.

Action-Not Available
Vendor-n/aRed Hat, Inc.
Product-satelliten/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-24882
Matching Score-4
Assigner-GitHub, Inc.
ShareView Details
Matching Score-4
Assigner-GitHub, Inc.
CVSS Score-9.1||CRITICAL
EPSS-0.19% / 41.08%
||
7 Day CHG+0.03%
Published-26 Apr, 2022 | 00:00
Updated-22 Apr, 2025 | 18:14
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Server side NTLM does not properly check parameters in FreeRDP

FreeRDP is a free implementation of the Remote Desktop Protocol (RDP). In versions prior to 2.7.0, NT LAN Manager (NTLM) authentication does not properly abort when someone provides and empty password value. This issue affects FreeRDP based RDP Server implementations. RDP clients are not affected. The vulnerability is patched in FreeRDP 2.7.0. There are currently no known workarounds.

Action-Not Available
Vendor-FreeRDPFedora Project
Product-freerdpextra_packages_for_enterprise_linuxfedoraFreeRDP
CWE ID-CWE-287
Improper Authentication
CVE-2017-7920
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-7.5||HIGH
EPSS-1.40% / 79.67%
||
7 Day CHG~0.00%
Published-07 Aug, 2017 | 08:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.

Action-Not Available
Vendor-n/aABB
Product-vsn300_for_react_firmwarevsn300_for_reactvsn300vsn300_firmwareABB VSN300 WiFi Logger Card
CWE ID-CWE-287
Improper Authentication
CVE-2017-8223
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-18.04% / 94.91%
||
7 Day CHG~0.00%
Published-25 Apr, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

On Wireless IP Camera (P2P) WIFICAM devices, an attacker can use the RTSP server on port 10554/tcp to watch the streaming without authentication via tcp/av0_1 or tcp/av0_0.

Action-Not Available
Vendor-wificamn/a
Product-wireless_ip_camera_\(p2p\)wireless_ip_camera_\(p2p\)_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2013-10004
Matching Score-4
Assigner-VulDB
ShareView Details
Matching Score-4
Assigner-VulDB
CVSS Score-6.5||MEDIUM
EPSS-0.39% / 58.91%
||
7 Day CHG~0.00%
Published-24 May, 2022 | 15:30
Updated-15 Apr, 2025 | 14:38
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
Telecommunication Software SAMwin Contact Center Suite Password SAMwinLIBVB.dll passwordScramble improper authentication

A vulnerability classified as critical was found in Telecommunication Software SAMwin Contact Center Suite 5.1. This vulnerability affects the function passwordScramble in the library SAMwinLIBVB.dll of the component Password Handler. Incorrect implementation of a hashing function leads to predictable authentication possibilities. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.

Action-Not Available
Vendor-telecomsoftwareTelecommunication Software
Product-samwin_agentsamwin_contact_centerSAMwin Contact Center Suite
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-307
Improper Restriction of Excessive Authentication Attempts
CVE-2013-0282
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-5||MEDIUM
EPSS-0.47% / 63.46%
||
7 Day CHG~0.00%
Published-12 Apr, 2013 | 22:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

OpenStack Keystone Grizzly before 2013.1, Folsom 2012.1.3 and earlier, and Essex does not properly check if the (1) user, (2) tenant, or (3) domain is enabled when using EC2-style authentication, which allows context-dependent attackers to bypass access restrictions.

Action-Not Available
Vendor-n/aOpenStack
Product-keystonen/a
CWE ID-CWE-287
Improper Authentication
CVE-2012-6452
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.35% / 56.58%
||
7 Day CHG~0.00%
Published-27 May, 2014 | 15:00
Updated-12 Apr, 2025 | 10:46
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Axway Secure Messenger before 6.5 Updated Release 7, as used in Axway Email Firewall, provides different responses to authentication requests depending on whether the user exists, which allows remote attackers to enumerate users via a series of requests.

Action-Not Available
Vendor-axwayn/a
Product-secure_messengeremail_firewalln/a
CWE ID-CWE-287
Improper Authentication
CVE-2010-1221
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.31% / 53.42%
||
7 Day CHG~0.00%
Published-07 Apr, 2010 | 15:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CA XOsoft r12.0 and r12.5 does not properly perform authentication, which allows remote attackers to enumerate usernames via a SOAP request.

Action-Not Available
Vendor-n/aCA Technologies (Broadcom Inc.)
Product-xosoft_content_distributionxosoft_replicationxosoft_high_availabilityn/a
CWE ID-CWE-287
Improper Authentication
CVE-2010-1222
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.31% / 53.42%
||
7 Day CHG~0.00%
Published-07 Apr, 2010 | 15:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CA XOsoft r12.5 does not properly perform authentication, which allows remote attackers to obtain potentially sensitive information via a SOAP request.

Action-Not Available
Vendor-n/aCA Technologies (Broadcom Inc.)
Product-xosoft_content_distributionxosoft_replicationxosoft_high_availabilityn/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-6530
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.54% / 66.65%
||
7 Day CHG~0.00%
Published-20 Jul, 2017 | 13:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Televes COAXDATA GATEWAY 1Gbps devices doc-wifi-hgw_v1.02.0014 4.20 do not check password.shtml authorization, leading to Arbitrary password change.

Action-Not Available
Vendor-televesn/a
Product-coaxdata_gateway_1gbps_firmwarecoaxdata_gateway_1gbpsn/a
CWE ID-CWE-287
Improper Authentication
CVE-2011-0435
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.83% / 73.63%
||
7 Day CHG~0.00%
Published-07 Mar, 2011 | 20:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Domain Technologie Control (DTC) before 0.32.9 does not require authentication for (1) admin/bw_per_month.php and (2) client/bw_per_month.php, which allows remote attackers to obtain potentially sensitive bandwidth information via a direct request.

Action-Not Available
Vendor-gplhostn/a
Product-domain_technologie_controln/a
CWE ID-CWE-287
Improper Authentication
CVE-2010-4690
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.50% / 64.75%
||
7 Day CHG~0.00%
Published-07 Jan, 2011 | 22:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Mobile User Security (MUS) service on Cisco Adaptive Security Appliances (ASA) 5500 series devices with software before 8.3(2) does not properly authenticate HTTP requests from a Web Security appliance (WSA), which might allow remote attackers to obtain sensitive information via a HEAD request, aka Bug ID CSCte53635.

Action-Not Available
Vendor-n/aCisco Systems, Inc.
Product-adaptive_security_appliance_softwareasa_55005500_series_adaptive_security_appliancen/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-6047
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
ShareView Details
Matching Score-4
Assigner-Cybersecurity and Infrastructure Security Agency (CISA) Industrial Control Systems (ICS)
CVSS Score-9.8||CRITICAL
EPSS-0.26% / 49.22%
||
7 Day CHG~0.00%
Published-02 Apr, 2019 | 19:39
Updated-05 Aug, 2024 | 15:18
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Detcon Sitewatch Gateway, all versions without cellular, Passwords are presented in plaintext in a file that is accessible without authentication.

Action-Not Available
Vendor-3mDetcon
Product-detcon_sitewatch_gatewaySitewatch Gateway
CWE ID-CWE-287
Improper Authentication
CWE ID-CWE-255
Not Available
CVE-2022-23317
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.29% / 52.01%
||
7 Day CHG~0.00%
Published-15 Feb, 2022 | 12:53
Updated-03 Aug, 2024 | 03:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

CobaltStrike <=4.5 HTTP(S) listener does not determine whether the request URL begins with "/", and attackers can obtain relevant information by specifying the URL.

Action-Not Available
Vendor-helpsystemsn/a
Product-cobalt_striken/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-23320
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.30% / 52.93%
||
7 Day CHG~0.00%
Published-07 Feb, 2022 | 10:47
Updated-03 Aug, 2024 | 03:36
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

XMPie uStore 12.3.7244.0 allows for administrators to generate reports based on raw SQL queries. Since the application ships with default administrative credentials, an attacker may authenticate into the application and exfiltrate sensitive information from the database.

Action-Not Available
Vendor-n/aXerox Corporation
Product-xmpie_ustoren/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-23723
Matching Score-4
Assigner-Ping Identity Corporation
ShareView Details
Matching Score-4
Assigner-Ping Identity Corporation
CVSS Score-7.7||HIGH
EPSS-0.20% / 42.20%
||
7 Day CHG~0.00%
Published-02 May, 2022 | 22:05
Updated-03 Aug, 2024 | 03:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
PingFederate PingOneMFA Integration Kit MFA Bypass

An MFA bypass vulnerability exists in the PingFederate PingOne MFA Integration Kit when adapter HTML templates are used as part of an authentication flow.

Action-Not Available
Vendor-Ping Identity Corp.
Product-pingone_mfa_integration_kitPingFederate PingOne MFA Integration Kit
CWE ID-CWE-288
Authentication Bypass Using an Alternate Path or Channel
CWE ID-CWE-287
Improper Authentication
CVE-2010-4481
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.69% / 70.92%
||
7 Day CHG~0.00%
Published-17 Dec, 2010 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

phpMyAdmin before 3.4.0-beta1 allows remote attackers to bypass authentication and obtain sensitive information via a direct request to phpinfo.php, which calls the phpinfo function.

Action-Not Available
Vendor-n/aphpMyAdmin
Product-phpmyadminn/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-5635
Matching Score-4
Assigner-Apache Software Foundation
ShareView Details
Matching Score-4
Assigner-Apache Software Foundation
CVSS Score-7.5||HIGH
EPSS-1.13% / 77.44%
||
7 Day CHG~0.00%
Published-19 Oct, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

In Apache NiFi before 0.7.2 and 1.x before 1.1.2 in a cluster environment, if an anonymous user request is replicated to another node, the originating node identity is used rather than the "anonymous" user.

Action-Not Available
Vendor-The Apache Software Foundation
Product-nifiApache NiFi
CWE ID-CWE-287
Improper Authentication
CVE-2019-11733
Matching Score-4
Assigner-Mozilla Corporation
ShareView Details
Matching Score-4
Assigner-Mozilla Corporation
CVSS Score-9.8||CRITICAL
EPSS-0.39% / 59.28%
||
7 Day CHG~0.00%
Published-27 Sep, 2019 | 17:22
Updated-04 Aug, 2024 | 23:03
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

When a master password is set, it is required to be entered again before stored passwords can be accessed in the 'Saved Logins' dialog. It was found that locally stored passwords can be copied to the clipboard thorough the 'copy password' context menu item without re-entering the master password if the master password had been previously entered in the same session, allowing for potential theft of stored passwords. This vulnerability affects Firefox < 68.0.2 and Firefox ESR < 68.0.2.

Action-Not Available
Vendor-Mozilla Corporation
Product-firefoxfirefox_esrFirefoxFirefox ESR
CWE ID-CWE-287
Improper Authentication
CVE-2017-5189
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
ShareView Details
Matching Score-4
Assigner-OpenText (formerly Micro Focus)
CVSS Score-4.3||MEDIUM
EPSS-0.18% / 40.12%
||
7 Day CHG~0.00%
Published-02 Mar, 2018 | 20:00
Updated-17 Sep, 2024 | 03:59
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available
private SSL key embedded in JAR file in iManager

NetIQ iManager before 3.0.3 delivered a SSL private key in a Java application (JAR file) for authentication to Sentinel, allowing attackers to extract and establish their own connections to the Sentinel appliance.

Action-Not Available
Vendor-netiqNetIQ
Product-imanageriManager
CWE ID-CWE-522
Insufficiently Protected Credentials
CWE ID-CWE-287
Improper Authentication
CVE-2012-3884
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-5||MEDIUM
EPSS-0.31% / 53.95%
||
7 Day CHG~0.00%
Published-26 Jul, 2012 | 22:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

AirDroid 1.0.4 beta implements authentication through direct transmission of a password hash over HTTP, which makes it easier for remote attackers to obtain access by sniffing the local wireless network and then replaying the authentication data.

Action-Not Available
Vendor-airdroidn/a
Product-airdroidn/a
CWE ID-CWE-287
Improper Authentication
CVE-2020-28973
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-7.5||HIGH
EPSS-0.35% / 56.58%
||
7 Day CHG~0.00%
Published-21 Apr, 2021 | 18:58
Updated-04 Aug, 2024 | 16:48
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The ABUS Secvest wireless alarm system FUAA50000 (v3.01.17) fails to properly authenticate some requests to its built-in HTTPS interface. Someone can use this vulnerability to obtain sensitive information from the system, such as usernames and passwords. This information can then be used to reconfigure or disable the alarm system.

Action-Not Available
Vendor-abusn/a
Product-secvest_wireless_alarm_system_fuaa50000secvest_wireless_alarm_system_fuaa50000_firmwaren/a
CWE ID-CWE-287
Improper Authentication
CVE-2009-1384
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-5||MEDIUM
EPSS-1.52% / 80.48%
||
7 Day CHG~0.00%
Published-28 May, 2009 | 20:14
Updated-07 Aug, 2024 | 05:13
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

pam_krb5 2.2.14 through 2.3.4, as used in Red Hat Enterprise Linux (RHEL) 5, generates different password prompts depending on whether the user account exists, which allows remote attackers to enumerate valid usernames.

Action-Not Available
Vendor-eyrien/aRed Hat, Inc.
Product-pam-krb5enterprise_linuxn/a
CWE ID-CWE-287
Improper Authentication
CVE-2017-2659
Matching Score-4
Assigner-Red Hat, Inc.
ShareView Details
Matching Score-4
Assigner-Red Hat, Inc.
CVSS Score-5.3||MEDIUM
EPSS-0.27% / 50.59%
||
7 Day CHG~0.00%
Published-20 Mar, 2019 | 20:44
Updated-05 Aug, 2024 | 14:02
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

It was found that dropbear before version 2013.59 with GSSAPI leaks whether given username is valid or invalid. When an invalid username is given, the GSSAPI authentication failure was incorrectly counted towards the maximum allowed number of password attempts.

Action-Not Available
Vendor-dropbear_ssh_project[UNKNOWN]
Product-dropbear_sshdropbear
CWE ID-CWE-209
Generation of Error Message Containing Sensitive Information
CWE ID-CWE-287
Improper Authentication
CVE-2010-0521
Matching Score-4
Assigner-Apple Inc.
ShareView Details
Matching Score-4
Assigner-Apple Inc.
CVSS Score-5||MEDIUM
EPSS-0.27% / 49.89%
||
7 Day CHG~0.00%
Published-30 Mar, 2010 | 18:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Server Admin in Apple Mac OS X Server before 10.6.3 does not properly enforce authentication for directory binding, which allows remote attackers to obtain potentially sensitive information from Open Directory via unspecified LDAP requests.

Action-Not Available
Vendor-n/aApple Inc.
Product-mac_os_xmac_os_x_servern/a
CWE ID-CWE-287
Improper Authentication
CVE-2012-3315
Matching Score-4
Assigner-IBM Corporation
ShareView Details
Matching Score-4
Assigner-IBM Corporation
CVSS Score-5||MEDIUM
EPSS-0.40% / 60.17%
||
7 Day CHG~0.00%
Published-08 Nov, 2012 | 11:00
Updated-11 Apr, 2025 | 00:51
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

The Java servlets in the management console in IBM Tivoli Federated Identity Manager (TFIM) through 6.2.2 and Tivoli Federated Identity Manager Business Gateway (TFIMBG) before 6.2.2 do not require authentication for all resource downloads, which allows remote attackers to bypass intended J2EE security constraints, and obtain sensitive information related to (1) federation metadata or (2) a web plugin configuration template, via a crafted request.

Action-Not Available
Vendor-n/aIBM Corporation
Product-tivoli_federated_identity_manager_business_gatewaytivoli_federated_identity_managern/a
CWE ID-CWE-287
Improper Authentication
CVE-2022-22289
Matching Score-4
Assigner-Samsung Mobile
ShareView Details
Matching Score-4
Assigner-Samsung Mobile
CVSS Score-5.3||MEDIUM
EPSS-0.24% / 47.41%
||
7 Day CHG~0.00%
Published-07 Jan, 2022 | 22:39
Updated-03 Aug, 2024 | 03:07
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Improper access control vulnerability in S Assistant prior to version 7.5 allows attacker to remotely get senstive information.

Action-Not Available
Vendor-SamsungSamsung Electronics
Product-s_assistantS Assistant
CWE ID-CWE-287
Improper Authentication
CVE-2017-1000030
Matching Score-4
Assigner-MITRE Corporation
ShareView Details
Matching Score-4
Assigner-MITRE Corporation
CVSS Score-9.8||CRITICAL
EPSS-3.58% / 87.28%
||
7 Day CHG~0.00%
Published-13 Jul, 2017 | 20:00
Updated-20 Apr, 2025 | 01:37
Rejected-Not Available
Known To Be Used In Ransomware Campaigns?-Not Available
KEV Added-Not Available
KEV Action Due Date-Not Available

Oracle, GlassFish Server Open Source Edition 3.0.1 (build 22) is vulnerable to Java Key Store Password Disclosure vulnerability, that makes it possible to provide an unauthenticated attacker plain text password of administrative user and grant access to the web-based administration interface.

Action-Not Available
Vendor-n/aOracle Corporation
Product-glassfish_servern/a
CWE ID-CWE-287
Improper Authentication
  • Previous
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • Next
Details not found