SOPlanning before 1.47 has Incorrect Access Control because certain secret key information, and the related authentication algorithm, is public. The key for admin is hardcoded in the installation code, and there is no key for publicsp (which is a guest account).
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
The management tool in MyLittleAdmin 3.8 allows remote attackers to execute arbitrary code because machineKey is hardcoded (the same for all customers' installations) in web.config, and can be used to send serialized ASP code.
Calibre-Web 0.6.6 allows authentication bypass because of the 'A0Zr98j/3yX R~XHH!jmN]LWX/,?RT' hardcoded secret key.
Improper Authorization vulnerability of Pepperl+Fuchs P+F Comtrol RocketLinx ES7510-XT, ES8509-XT, ES8510-XT, ES9528-XTv2, ES7506, ES7510, ES7528, ES8508, ES8508F, ES8510, ES8510-XTE, ES9528/ES9528-XT (all versions) use undocumented accounts.
Arbitrary code execution vlnerability in Operation bridge Manager, Application Performance Management and Operations Bridge (containerized) vulnerability in Micro Focus products products Operation Bridge Manager, Operation Bridge (containerized) and Application Performance Management. The vulneravility affects: 1.) Operation Bridge Manager versions 2020.05, 2019.11, 2019.05, 2018.11, 2018.05, 10.63,10.62, 10.61, 10.60, 10.12, 10.11, 10.10 and all earlier versions. 2.) Operations Bridge (containerized) 2020.05, 2019.08, 2019.05, 2018.11, 2018.08, 2018.05. 2018.02 and 2017.11. 3.) Application Performance Management versions 9,51, 9.50 and 9.40 with uCMDB 10.33 CUP 3. The vulnerability could allow Arbitrary code execution.
The Jitsi Meet (aka docker-jitsi-meet) stack on Docker before stable-4384-1 uses default passwords (such as passw0rd) for system accounts.
A vulnerability in TOTOLINK N200RE_v5 firmware V9.3.5u.6139 allows unauthenticated attackers to access the telnet service via a crafted POST request. Attackers are also able to leverage this vulnerability to login as root via hardcoded credentials.
OpsRamp Gateway before 7.0.0 has a backdoor account vadmin with the password 9vt@f3Vt that allows root SSH access to the server. This issue has been resolved in OpsRamp Gateway firmware version 7.0.0 where an administrator and a system user accounts are the only available user accounts for the gateway appliance.
ZPanel 10.0.1 has insufficient entropy for its password reset process.
Prolink router PRS1841 was discovered to contain hardcoded credentials for its Telnet and FTP services.
Devices ekorCCP and ekorRCI are vulnerable due to access to the FTP service using default credentials. Exploitation of this vulnerability can allow an attacker to modify critical files that could allow the creation of new users, delete or modify existing users, modify configuration files, install rootkits or backdoors.
Because of hard-coded SSH keys for the root user in Amino Communications AK45x series, AK5xx series, AK65x series, Aria6xx series, Aria7/AK7Xx series, Kami7B, an attacker may remotely log in through SSH.
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
A security issue was discovered in the Kubernetes Image Builder versions <= v0.1.37 where default credentials are enabled during the image build process. Virtual machine images built using the Proxmox provider do not disable these default credentials, and nodes using the resulting images may be accessible via these default credentials. The credentials can be used to gain root access. Kubernetes clusters are only affected if their nodes use VM images created via the Image Builder project with its Proxmox provider.
The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.
Merit LILIN AH55B04 & AH55B08 DVR firm has hard-coded administrator credentials. An unauthenticated remote attacker can use these credentials to log in administrator page, to manipulate system or disrupt service.
IBM XIV Storage System 2810-A14 and 2812-A14 devices before level 10.2.4.e-2 and 2810-114 and 2812-114 devices before level 11.1.1 have hardcoded passwords for unspecified accounts, which allows remote attackers to gain user access via unknown vectors. IBM X-Force ID: 75041.
Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
An issue was discovered in Polycom Web Management Interface G3/HDX 8000 HD with Durango 2.6.0 4740 software and embedded Polycom Linux Development Platform 2.14.g3. It has a blank administrative password by default, and can be successfully used without setting this password.
A vulnerability classified as critical has been found in Go-Tribe gotribe up to cd3ccd32cd77852c9ea73f986eaf8c301cfb6310. Affected is the function Sign of the file pkg/token/token.go. The manipulation of the argument config.key leads to hard-coded credentials. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The patch is identified as 4fb9b9e80a2beedd09d9fde4b9cf5bd510baf18f. It is recommended to apply a patch to fix this issue.
The Carlo Gavazzi EOS-Box stores hard-coded passwords in the PHP file of the device. By using the hard-coded passwords, attackers can log into the device with administrative privileges. This could allow the attacker to have unauthorized access.
A vulnerability was found in TOTOLINK CP450 4.1.0cu.747_B20191224. It has been classified as critical. This affects an unknown part of the file /web_cste/cgi-bin/product.ini of the component Telnet Service. The manipulation leads to use of hard-coded password. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273255. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Accellion File Transfer Appliance version FTA_8_0_540 suffers from an instance of CWE-798: Use of Hard-coded Credentials.
Use of Hard-coded Credentials vulnerability in TNB Mobile Solutions Cockpit Software allows Read Sensitive Strings Within an Executable.This issue affects Cockpit Software: before v2.13.
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version 20.0.2786 (VA/SaaS deployments) contain a default admin account and an installation‑time endpoint at `/admin/query/update_database.php` that can be accessed without authentication. An attacker who can reach the installation web interface can POST arbitrary `root_user` and `root_password` values, causing the script to replace the default admin credentials with attacker‑controlled ones. The script also contains hard‑coded SHA‑512 and SHA‑1 hashes of the default password, allowing the attacker to bypass password‑policy validation. As a result, an unauthenticated remote attacker can obtain full administrative control of the system during the initial setup. This vulnerability has been identified by the vendor as: V-2024-022 — Insecure Installation Credentials.
Book Store Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
Sanitization Management System v1.0 was discovered to contain hardcoded credentials which allows attackers to escalate privileges and access the admin panel.
PTZOptics and possibly other ValueHD-based pan-tilt-zoom cameras use hard-coded, default administrative credentials. The passwords can readily be cracked. Many cameras have SSH or telnet listening on all interfaces. The passwords cannot be changed by the user, nor can the SSH or telnet service be disabled by the user.
Hardcoded Credentials in multiple SPRECON-E CPU variants of Sprecher Automation allows an remote attacker to take over the device. These accounts should be deactivated according to Sprecher's hardening guidelines.
go-admin (aka GO Admin) 2.0.12 uses the string go-admin as a production JWT key.
The installation script in Katello 1.0 and earlier does not properly generate the Application.config.secret_token value, which causes each default installation to have the same secret token, and allows remote attackers to authenticate to the CloudForms System Engine web interface as an arbitrary user by creating a cookie using the default secret_token.
Sage 300 through 2022 uses a hard-coded 40-byte blowfish key to encrypt and decrypt user passwords and SQL connection strings stored in ISAM database files in the shared data directory. This issue could allow attackers to decrypt user passwords and SQL connection strings.
The optional Web Screens and Global Search features for Sage 300 through version 2022 use a hard-coded 40-byte blowfish key ("LandlordPassKey") to encrypt and decrypt secrets stored in configuration files and in database tables.
A specific file on the sERP server if Kyungrinara(ERP solution) has a fixed password with the SYSTEM authority. This vulnerability could allow attackers to leak or steal sensitive information or execute malicious commands.
Anevia Flamingo XL/XS 3.6.20 contains a critical vulnerability with weak default administrative credentials that can be easily guessed. Attackers can leverage these hard-coded credentials to gain full remote system control without complex authentication mechanisms.
The demo feature in Oracle GlassFish Open Source Edition 5.0 has TCP port 7676 open by default with a password of admin for the admin account. This allows remote attackers to obtain potentially sensitive information, perform database operations, or manipulate the demo via a JMX RMI session, aka a "jmx_rmi remote monitoring and control problem." NOTE: this is not an Oracle supported product.
In TOTOLINK A3002R TOTOLINK-A3002R-He-V1.1.1-B20200824.0128 in the shadow.sample file, root is hardcoded in the firmware.
Weintek EasyBuilder Pro contains a vulnerability that, even when the private key is immediately deleted after the crash report transmission is finished, the private key is exposed to the public, which could result in obtaining remote control of the crash report server.
A flaw in the Zyxel LTE3301-M209 firmware verisons prior to V1.00(ABLG.6)C0 could allow a remote attacker to access the device using an improper pre-configured password if the remote administration feature has been enabled by an authenticated administrator.
The affected products store both public and private key that are used to sign and protect Custom Parameter Set (CPS) file from modification. An attacker that manages to exploit this vulnerability will be able to change the CPS file, sign it so that it is trusted as the legitimate CPS file. This issue affects * FOXMAN-UN product: FOXMAN-UN R15B, FOXMAN-UN R15A, FOXMAN-UN R14B, FOXMAN-UN R14A, FOXMAN-UN R11B, FOXMAN-UN R11A, FOXMAN-UN R10C, FOXMAN-UN R9C; * UNEM product: UNEM R15B, UNEM R15A, UNEM R14B, UNEM R14A, UNEM R11B, UNEM R11A, UNEM R10C, UNEM R9C. List of CPEs: * cpe:2.3:a:hitachienergy:foxman-un:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:foxman-un:R9C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R15A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R14A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11B:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R11A:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R10C:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:unem:R9C:*:*:*:*:*:*:*
MegaRAC Default Credentials Vulnerability
Zohocorp ManageEngine DDI Central versions 4001 and prior were vulnerable to agent takeover vulnerability due to the hard-coded sensitive keys.
EXFO - BV-10 Performance Endpoint Unit Undocumented privileged user. Unit has an undocumented hard-coded privileged user.
Le-yan Personnel and Salary Management System has hard-coded database account and password within the website source code. An unauthenticated remote attacker can access, modify system data or disrupt service.
Use of hard-coded credentials for the telnet server of CentreCOM AR260S V2 firmware versions prior to Ver.3.3.7 allows a remote unauthenticated attacker to execute an arbitrary OS command.
Novel-Plus v3.6.2 was discovered to contain a hard-coded JWT key located in the project config file. This vulnerability allows attackers to create a custom user session.