Cobham Sailor 900 and 6000 satellite terminals with firmware 1.08 MFHF and 2.11 VHF have hardcoded credentials for the administrator account, which allows attackers to obtain administrative control by leveraging physical access or terminal access.
The web application portal of the Cobham EXPLORER 710, firmware version 1.07, allows unauthenticated access to port 5454. This could allow an unauthenticated, remote attacker to connect to this port via Telnet and execute 86 Attention (AT) commands, including some that provide unauthenticated, shell-like access to the device.
ZModo ZP-NE14-S and ZP-IBH-13W devices have a hardcoded root password, which makes it easier for remote attackers to obtain access via a TELNET session.
In processMessageImpl of ClientModeImpl.java, there is a possible credential disclosure in the TOFU flow due to a logic error in the code. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
Milesight IP security cameras through 2016-11-14 have a default root password in /etc/shadow that is the same across different customers' installations.
Use of Hard-coded Credentials in GitHub repository nuxtlabs/github-module prior to 1.6.2.
Linksys WAP54Gv3 firmware 3.04.03 and earlier uses a hard-coded username (Gemtek) and password (gemtekswd) for a debug interface for certain web pages, which allows remote attackers to execute arbitrary commands via the (1) data1, (2) data2, or (3) data3 parameters to (a) Debug_command_page.asp and (b) debug.cgi.
Milesight IP security cameras through 2016-11-14 have a default set of 10 privileged accounts with hardcoded credentials. They are accessible if the customer has not configured 10 actual user accounts.
An issue was discovered on MOBOTIX S14 MX-V4.2.1.61 devices. There is a default password of meinsm for the admin account.
Milesight IP security cameras through 2016-11-14 have a hardcoded SSL private key under the /etc/config directory.
A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled.
The Premium Age Verification / Restriction for WordPress plugin for WordPress is vulnerable to arbitrary file read and write due to the existence of an insufficiently protected remote support functionality in remote_tunnel.php in all versions up to, and including, 3.0.2. This makes it possible for unauthenticated attackers to read from or write to arbitrary files on the affected site's server which may make the exposure of sensitive information or remote code execution possible.
A vulnerability in Cisco Emergency Responder could allow an unauthenticated, remote attacker to log in to an affected device using the root account, which has default, static credentials that cannot be changed or deleted. This vulnerability is due to the presence of static user credentials for the root account that are typically reserved for use during development. An attacker could exploit this vulnerability by using the account to log in to an affected system. A successful exploit could allow the attacker to log in to the affected system and execute arbitrary commands as the root user.
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.
ExaGrid appliances with firmware before 4.8 P26 have a default password of (1) inflection for the root shell account and (2) support for the support account in the web interface, which allows remote attackers to obtain administrative access via an SSH or HTTP session.
A vulnerability in Brocade Network Advisor Version Before 14.3.1 could allow an unauthenticated, remote attacker to log in to the JBoss Administration interface of an affected system using an undocumented user credentials and install additional JEE applications.
An issue was discovered on VOBOT CLOCK before 0.99.30 devices. An SSH server exists with a hardcoded vobot account that has root access.
iBall iB-WRA150N 1.2.6 build 110401 Rel.47776n devices have a hardcoded password of admin for the admin account, a hardcoded password of support for the support account, and a hardcoded password of user for the user account.
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
your_spotify is an open source, self hosted Spotify tracking dashboard. YourSpotify versions < 1.8.0 use a hardcoded JSON Web Token (JWT) secret to sign authentication tokens. Attackers can use this well-known value to forge valid authentication tokens for arbitrary users. This vulnerability allows attackers to bypass authentication and authenticate as arbitrary YourSpotify users, including admin users. This issue has been addressed in version 1.8.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
Use of Hard-coded Credentials in GitHub repository alextselegidis/easyappointments prior to 1.5.0.
This vulnerability exists in GajShield Data Security Firewall firmware versions prior to v4.28 (except v4.21) due to insecure default credentials which allows remote attacker to login as superuser by using default username/password via web-based management interface and/or exposed SSH port thereby enabling remote attackers to execute arbitrary commands with administrative/superuser privileges on the targeted systems. The vulnerability has been addressed by forcing the user to change their default password to a new non-default password.
The Auto-Maskin DCU 210E firmware contains an undocumented Dropbear SSH server, v2015.55, configured to listen on Port 22 while the DCU is running. The Dropbear server is configured with a hard-coded user name and password combination of root / amroot. The server is configured to use password only authentication not cryptographic keys, however the firmware image contains an RSA host-key for the server. An attacker can exploit this vulnerability to gain root access to the Angstrom Linux operating system and modify any binaries or configuration files in the firmware. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7.
backupmgt/pre_connect_check.php in Seagate BlackArmor NAS contains a hard-coded password of '!~@##$$%FREDESWWSED' for a backdoor user.
Versions of DocuTrac QuicDoc and Office Therapy that ship with DTISQLInstaller.exe version 1.6.4.0 and prior contain three credentials with known passwords: QDMaster, OTMaster, and sa.
GenX_FX is an advance IA trading platform that will focus on forex trading. A vulnerability was identified in the GenX FX backend where API keys and authentication tokens may be exposed if environment variables are misconfigured. Unauthorized users could gain access to cloud resources (Google Cloud, Firebase, GitHub, etc.).
The web application for ProGauge MAGLINK LX4 CONSOLE contains an administrative-level user account with a password that cannot be changed.
RevelaCode is an AI-powered faith-tech project that decodes biblical verses, prophecies and global events into accessible language. In versions below 1.0.1, a valid MongoDB Atlas URI with embedded username and password was accidentally committed to the public repository. This could allow unauthorized access to production or staging databases, potentially leading to data exfiltration, modification, or deletion. This is fixed in version 1.0.1. Workarounds include: immediately rotating credentials for the exposed database user, using a secret manager (like Vault, Doppler, AWS Secrets Manager, etc.) instead of storing secrets directly in code, or auditing recent access logs for suspicious activity.
D-Link DIR-620 devices, with a certain Rostelekom variant of firmware 1.0.37, have a hardcoded rostel account, which makes it easier for remote attackers to obtain access via a TELNET session.
Use of Hard-coded Credentials vulnerability in Samsung Electronics MagicINFO 9 Server allows Authentication Bypass.This issue affects MagicINFO 9 Server: less than 21.1080.0.
MASTER IPCAMERA01 3.3.4.2103 devices have a hardcoded password of cat1029 for the root account.
H3C Magic B1ST v100R012 was discovered to contain a hardcoded password vulnerability in /etc/shadow, which allows attackers to log in as root.
An issue in PDQ Smart Deploy V.3.0.2040 allows an attacker to escalate privileges via the Credential encryption routines in SDCommon.dll
Siklu EtherHaul radios before 3.7.1 and 6.x before 6.9.0 have a built-in, hidden root account, with an unchangeable password that is the same across all devices. This account is accessible via both SSH and the device's web interface and grants access to the underlying embedded Linux OS on the device, allowing full control over it.
D-Link DIR-300 REVA FIRMWARE v1.06B05_WW contains hardcoded credentials in the Telnet service.
A remote, unauthenticated attacker can gain remote code execution on the the Tenda AC15 router with a specially crafted password parameter for the COOKIE header.
Trango Altum AC600 devices have a built-in, hidden root account, with a default password of abcd1234. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Austrian Archaeological Institute (AI) OpenAtlas v8.11.0 as discovered to contain a hardcoded Administrator password.
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue.
In D-Link DIR-860L REVA FIRMWARE PATCH 1.10..B04, the Telnet service contains hardcoded credentials, enabling attackers to log in remotely to the Telnet service and perform arbitrary commands.
An issue was discovered on the D-Link DWR-932B router. Undocumented TELNET and SSH services provide logins to admin with the password admin and root with the password 1234.
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
Use of hard-coded credentials vulnerability affecting Vonets industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication using hard-coded administrator credentials. These accounts cannot be disabled.
NETGEAR Arlo base stations with firmware 1.7.5_6178 and earlier, Arlo Q devices with firmware 1.8.0_5551 and earlier, and Arlo Q Plus devices with firmware 1.8.1_6094 and earlier have a default password of 12345678, which makes it easier for remote attackers to obtain access after a factory reset or in a factory configuration.
Trango Apex <= 2.1.1, ApexLynx < 2.0, ApexOrion < 2.0, ApexPlus <= 3.2.0, Giga <= 2.6.1, GigaLynx < 2.0, GigaOrion < 2.0, GigaPlus <= 3.2.3, GigaPro <= 1.4.1, StrataLink < 3.0, and StrataPro devices have a built-in, hidden root account, with a default password that was once stored in cleartext within a software update package on a Trango FTP server. This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
Shenzhen Guoxin Synthesis image system before 8.3.0 has a 123456Qw default password.
Trango ApexLynx 2.0, ApexOrion 2.0, GigaLynx 2.0, GigaOrion 2.0, and StrataLink 3.0 devices have a built-in, hidden root account, with a default password for which the MD5 hash value is public (but the cleartext value is perhaps not yet public). This account is accessible via SSH and/or TELNET, and grants access to the underlying embedded UNIX OS on the device, allowing full control over it.
A Hard-coded Credentials vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could enable an attacker to gain access to the device.
Use of hard-coded password to the patients' database allows an attacker to retrieve sensitive data stored in the database. The password is the same among all Simple Care software installations. This issue affects Estomed Sp. z o.o. Simple Care software in all versions. The software is no longer supported.