A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function um_red of the file /goform/RP_setBasicAuto. The manipulation of the argument hname leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Improper neutralization of special elements in the SonicWall SSL-VPN SMA100 series management interface allows a remote authenticated attacker to inject OS Commands which potentially leads to remote command execution vulnerability or denial of service (DoS) attack.
Command injection vulnerability in Document.php in Synology Office 2.2.0-1502 and 2.2.1-1506 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the crafted file name of RTF documents.
Vulnerabilities in the ClearPass Policy Manager web-based management interface allow remote authenticated users to run arbitrary commands on the underlying host. Successful exploits could allow an attacker to execute arbitrary commands as root on the underlying operating system leading to complete system compromise in Aruba ClearPass Policy Manager version(s): ClearPass Policy Manager 6.10.x: 6.10.7 and below and ClearPass Policy Manager 6.9.x: 6.9.12 and below.
IBM Security Guardium 11.4 could allow a remote authenticated attacker to execute arbitrary commands on the system by sending a specially crafted request. IBM X-Force ID: 240901.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This affects the function RP_setBasicAuto of the file /goform/RP_setBasicAuto. The manipulation of the argument staticIp/staticNetmask leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Improper Input Validation vulnerability in N-able N-central allows OS Command Injection.This issue affects N-central: before 2025.3.1.
A vulnerability in the web UI of Cisco Integrated Management Controller (IMC) could allow an authenticated, remote attacker to inject arbitrary code and execute arbitrary commands at the underlying operating system level. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted commands to the web-based management interface of the affected software. A successful exploit could allow the attacker to inject and execute arbitrary commands at the underlying operating system level.
Autolab is a course management service, initially developed by a team of students at Carnegie Mellon University, that enables instructors to offer autograded programming assignments to their students over the Web. A remote code execution vulnerability was discovered in Autolab's MOSS functionality, whereby an instructor with access to the feature might be able to execute code on the server hosting Autolab. This vulnerability has been patched in version 2.10.0. As a workaround, disable the MOSS feature if it is unneeded by replacing the body of `run_moss` in `app/controllers/courses_controller.rb` with `render(plain: "Feature disabled", status: :bad_request) && return`.
A vulnerability was found in DCN DCME-720 9.1.5.11. This affects an unknown function of the file /usr/local/www/function/audit/newstatistics/ip_block.php of the component Web Management Backend. Performing manipulation of the argument ip results in os command injection. It is possible to initiate the attack remotely. The exploit has been made public and could be used. Other products might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.
The restricted shell interface in UCOPIA Wireless Appliance before 5.1.8 allows remote authenticated users to gain 'admin' privileges via shell metacharacters in the less command.
Users with permission to create or configure agents in Jenkins 1.37 and earlier could configure an EC2 agent to run arbitrary shell commands on the master node whenever the agent was supposed to be launched. Configuration of these agents now requires the 'Run Scripts' permission typically only granted to administrators.
Belkin LINKSYS RE6500 devices before 1.0.11.001 allow remote authenticated users to execute arbitrary commands via goform/systemCommand?command= in conjunction with the goform/pingstart program.
OS Command Injection vulnerability in the db_optimize component of Device42 Asset Management Appliance allows an authenticated attacker to execute remote code on the device. This issue affects: Device42 CMDB version 18.01.00 and prior versions.
SEPPmail through 12.1.17 allows command injection within the Admin Portal. An authenticated attacker is able to execute arbitrary code in the context of the user root.
NVIDIA BMC contains a vulnerability in SPX REST API, where an authorized attacker can inject arbitrary shell commands, which may lead to code execution, denial of service, information disclosure and data tampering.
A vulnerability has been found in Tenda AC10U 15.03.06.49 and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257458 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
ROOT version 6.9.03 and below is vulnerable to an authenticated shell metacharacter injection in the rootd daemon resulting in remote code execution
Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.
NVIDIA BMC contains a vulnerability in SPX REST API, where an authorized attacker can inject arbitrary shell commands, which may lead to code execution, denial of service, information disclosure and data tampering.
A security vulnerability has been detected in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This vulnerability affects the function addStaticRoute of the file /goform/addStaticRoute. Such manipulation of the argument staticRoute_IP_setting/staticRoute_Netmask_setting/staticRoute_Gateway_setting/staticRoute_Metric_setting/staticRoute_destType_setting leads to os command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Unsanitized input when setting a locale file leads to shell injection in mIPC camera firmware 5.3.1.2003161406. This allows an attacker to gain remote code execution on cameras running the firmware when a victim logs into a specially crafted mobile app.
Command Injection in the diagnostics interface of the Bosch Network Synchronizer allows unauthorized users full access to the device.
A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
An OS command injection vulnerability has been identified in LoadMaster. An authenticated UI user with any permission settings may be able to inject commands into a UI component using a shell command resulting in OS command injection.
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP1). The affected application incorrectly neutralizes special elements when creating a report which could lead to command injection.
Command injection is possible in the puppetlabs-mysql module prior to version 13.0.0. A malicious actor is able to exploit this vulnerability only if they are able to provide unsanitized input to the module. This condition is rare in most deployments of Puppet and Puppet Enterprise.
A Command Injection vulnerability exists in FortiManager 5.2.1 and earlier and FortiManager 5.0.10 and earlier via unspecified vectors, which could let a malicious user run systems commands when executing a report.
A vulnerability, which was classified as critical, has been found in Totolink X6000R 9.4.0cu.852_20230719. This issue affects the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component shttpd. The manipulation of the argument ip leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-256313 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Softaculous Webuzo contains a command injection vulnerability in the FTP management functionality. A remote, authenticated attacker can exploit this vulnerability to gain code execution on the system.
Softaculous Webuzo contains a command injection in the password reset functionality. A remote, authenticated attacker can exploit this vulnerability to gain code execution on the system.
MiR software versions prior to version 3.0.0 are affected by a command injection vulnerability. A malicious HTTP request crafted by an authenticated user could allow the execution of arbitrary commands on the underlying operating system.
A vulnerability was identified in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function RP_setBasic of the file /goform/RP_setBasic. The manipulation of the argument bssid leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. This issue affects the function um_inspect_cross_band of the file /goform/RP_setBasicAuto. The manipulation of the argument staticGateway leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 up to 20250801. Affected by this vulnerability is the function setDeviceName of the file /goform/setDeviceName. The manipulation of the argument DeviceName leads to os command injection. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability, which was classified as critical, was found in SkyworkAI DeepResearchAgent up to 08eb7f8eb9505d0094d75bb97ff7dacc3fa3bbf2. Affected is the function from_code/from_dict/from_mcp of the file src/tools/tools.py. The manipulation leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability was found in csmock where a regular user of the OSH service (anyone with a valid Kerberos ticket) can use the vulnerability to disclose the confidential Snyk authentication token and to run arbitrary commands on OSH workers.
A vulnerability, which was classified as critical, has been found in D-Link DI-7300G+ 19.12.25A1. Affected by this issue is some unknown functionality of the file in proxy_client.asp. The manipulation of the argument proxy_srv/proxy_lanport/proxy_lanip/proxy_srvport leads to os command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
A improper neutralization of special elements used in an os command ('os command injection') in Fortinet FortiADC version 7.0.0 through 7.0.2, FortiADC version 6.2.0 through 6.2.3, FortiADC version version 6.1.0 through 6.1.6, FortiADC version 6.0.0 through 6.0.4, FortiADC version 5.4.0 through 5.4.5 may allow an attacker to execute unauthorized code or commands via specifically crafted HTTP requests.
A improper neutralization of special elements used in an os command ('os command injection') in Fortinet FortiWeb version 7.0.0 through 7.0.2, FortiWeb version 6.3.6 through 6.3.20, FortiWeb 6.4 all versions allows attacker to execute unauthorized code or commands via specifically crafted HTTP requests.
There is a command injection vulnerability in ZTE MF258 Pro product. Due to insufficient validation of Ping Diagnosis interface parameter, an authenticated attacker could use the vulnerability to execute arbitrary commands.
An OS command injection vulnerability has been reported to affect several QNAP operating system versions. If exploited, the vulnerability could allow authenticated users to execute commands via a network. We have already fixed the vulnerability in the following versions: QTS 5.1.6.2722 build 20240402 and later QuTS hero h5.1.6.2734 build 20240414 and later
A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Authenticated command injection vulnerabilities exist in the ArubaOS command line interface. Successful exploitation of these vulnerabilities results in the ability to execute arbitrary commands as a privileged user on the underlying operating system.
D-Link DIR-816 A2_v1.10CNB04.img is vulnerable to Command Injection via /goform/SystemCommand. After the user passes in the command parameter, it will be spliced into byte_4836B0 by snprintf, and finally doSystem(&byte_4836B0); will be executed, resulting in a command injection.
The optional ShellUserGroupProvider in Apache NiFi 1.10.0 to 1.16.2 and Apache NiFi Registry 0.6.0 to 1.16.2 does not neutralize arguments for group resolution commands, allowing injection of operating system commands on Linux and macOS platforms. The ShellUserGroupProvider is not included in the default configuration. Command injection requires ShellUserGroupProvider to be one of the enabled User Group Providers in the Authorizers configuration. Command injection also requires an authenticated user with elevated privileges. Apache NiFi requires an authenticated user with authorization to modify access policies in order to execute the command. Apache NiFi Registry requires an authenticated user with authorization to read user groups in order to execute the command. The resolution removes command formatting based on user-provided arguments.
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability through an url parameter of an authenticated enpoint in Enphase IQ Gateway (formerly known as Envoy) allows OS Command Injection.This issue affects Envoy: from 4.x to 8.x and < 8.2.4225.
The management portal component of JetNexus/EdgeNexus ADC 4.2.8 was discovered to contain a command injection vulnerability. This vulnerability allows authenticated attackers to execute arbitrary commands through a specially crafted payload. This vulnerability can also be exploited from an unauthenticated context via unspecified vectors
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). This vulnerability affects the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument domain leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Airspan AirVelocity 1500 software versions prior to 15.18.00.2511 have a root command injection vulnerability in the ActiveBank parameter of the recoverySubmit.cgi script running on the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.